777 resultados para corneal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Corneal collagen cross-linking (CXL) has been described as a promising therapy for keratoconus. According to standard CXL protocol, epithelium should be debrided before treatment to allow penetration of riboflavin into the corneal stroma. However, removal of the epithelium can increase procedure risks. In this study we aim to evaluate stromal penetration of a biocompatible riboflavin-based nanoemulsion system (riboflavin-5-phosphate and riboflavin-base) in rabbit corneas with intact epithelium. Two riboflavin nanoemulsions were developed. Transmittance and absorption coefficient were measured on corneas with intact epithelia after 30, 60, 120, 180, and 240 minutes following exposure to either the nanoemulsions or standard 0.1% or 1% riboflavin-dextran solutions. For the nanoemulsions, the epithelium was removed after measurements to assure that the riboflavin had passed through the hydrophobic epithelium and retained within the stroma. Results were compared to de-epithelialized corneas exposed to 0.1% riboflavin solution and to the same riboflavin nanoemulsions for 30 minutes (standard protocol). Mean transmittance and absorption measured in epithelialized corneas receiving the standard 0.1% riboflavin solution did not reach the levels found on the debrided corneas using the standard technique. Neither increasing the time of exposure nor the concentration of the riboflavin solution from 0.1% to 1% improved riboflavin penetration through the epithelium. When using riboflavin-5-phosphate nanoemulsion for 240 minutes, we found no difference between the mean absorption coefficients to the standard cross-linking protocol (p = 0.54). Riboflavin nanoemulsion was able to penetrate the corneal epithelium, achieving, after 240 minutes, greater stromal concentration when compared to debrided corneas with the standard protocol (p = 0.002). The riboflavin-5-phosphate nanoemulsion diffused better into the stroma than the riboflavin-base nanoemulsion. © 2013 Bottos et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The repair process induced corneal ulcer in rabbits using platelet-rich plasma in the form of eyedrop or clot was clinically evaluated and compared. Sixty rabbits were divided into four groups of 15 animals, denominated platelet group (PG), clot group (CLG), control group (CG), and amniotic control group (AG). Experimental groups were then subdivided into three groups (M4, M7, M30), corresponding to the end of the evaluation period. There were no differences between treatments regarding ocular sensitivity, chemosis and ocular secretion. The groups treated with PRP either as eyedrop or a clot showed less opacity than the animals treated only with amniotic membrane at the moment of the final evaluation. The presence of corneal ulcers in the groups treated with PRP showed lower intensity than the other groups. Histomorphometric examination showed that corneal epithelization in the initial phase of the lesion was greater when using PRP. The use of amniotic membrane promoted corneal epithelial and stromal thickness, as well as synergism when associated to PRP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Bases Gerais da Cirurgia - FMB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Ciência Animal - FMVA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hemangiosarcoma is a malignant neoplasm and its corneal presentation is uncommon in the dog. The present work reports a case of primary corneal hemangiosarcoma on a mongrel female dog, 20kg, nine years old with a 2 month history of a mass with progressive growth in the right eye. The ophthalmic examination of the right eye showed blepharospasm, moderated conjunctival hyperemia and the presence of a reddish irregular nodule on the dorsal region of the cornea, occupying approximately 60% of the cornea. The ocular ultrasound revealed that the neoplasm affected only the cornea and the cytological examination diagnosed a malignant mesenchymal neoplasm. The patient was submitted to keratectomy followed by a third eyelid flap. The excised material was sent for histopathological analysis that diagnosed hemangiosarcoma. Fifteen days after surgery the third eyelid flap was removed and the ophthalmic examination revealed recurrence of the tumor, with the mass occupying the entire cornea and part of the bulbar conjunctiva. The patient was submitted to enucleation. No alterations were observed on the abdominal ultrasound and thoracic radiography, showing the primary characteristics of the disease. Two years after surgery the patient is clinically healthy, without any signs of recurrence or metastasis. Despite the surgical excision of the tumor with free margins, in cases of hemangiosarcoma with aggressive behavior, the enucleation should be considered as a viable option for a successfull therapeutic protocol and better prognosis of the patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate endothelial cell sample size and statistical error in corneal specular microscopy (CSM) examinations. Methods: One hundred twenty examinations were conducted with 4 types of corneal specular microscopes: 30 with each BioOptics, CSO, Konan, and Topcon corneal specular microscopes. All endothelial image data were analyzed by respective instrument software and also by the Cells Analyzer software with a method developed in our lab(US Patent). A reliability degree (RD) of 95% and a relative error (RE) of 0.05 were used as cut-off values to analyze images of the counted endothelial cells called samples. The sample size mean was the number of cells evaluated on the images obtained with each device. Only examinations with RE<0.05 were considered statistically correct and suitable for comparisons with future examinations. The Cells Analyzer software was used to calculate the RE and customized sample size for all examinations. Results: Bio-Optics: sample size, 97 +/- 22 cells; RE, 6.52 +/- 0.86; only 10% of the examinations had sufficient endothelial cell quantity (RE<0.05); customized sample size, 162 +/- 34 cells. CSO: sample size, 110 +/- 20 cells; RE, 5.98 +/- 0.98; only 16.6% of the examinations had sufficient endothelial cell quantity (RE<0.05); customized sample size, 157 +/- 45 cells. Konan: sample size, 80 +/- 27 cells; RE, 10.6 +/- 3.67; none of the examinations had sufficient endothelial cell quantity (RE>0.05); customized sample size, 336 +/- 131 cells. Topcon: sample size, 87 +/- 17 cells; RE, 10.1 +/- 2.52; none of the examinations had sufficient endothelial cell quantity (RE>0.05); customized sample size, 382 +/- 159 cells. Conclusions: A very high number of CSM examinations had sample errors based on Cells Analyzer software. The endothelial sample size (examinations) needs to include more cells to be reliable and reproducible. The Cells Analyzer tutorial routine will be useful for CSM examination reliability and reproducibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The methodology currently used for interpretation of the cornea and anterior segment tomography for the diagnosis of corneal ectasia and its susceptibility. Methods: Description of the methodology and clinical interpretation of corneal and anterior segment tomography indexes; report of three cases demonstrating the importance of this new diagnostic tool (Pentacam HR (R)) in ophthalmological practice. Conclusion: The use of corneal and anterior segment tomography seems to be an effective method to increase the sensitivity and specificity for the diagnosis and early detection of corneal ectasia.