822 resultados para chemiluminescence immunoassay
Resumo:
Therapeutic drug monitoring of cyclosporin (CsA) has been established as part of the routine clinical treatment of patients following organ transplantation for more than 20 years, and based on contemporary knowledge, many consensus guidelines have been published to assist clinics and laboratories attain optimal strategies for patient care. This article addresses the newer directions in CsA monitoring, with particular reference to the Australasian situation that has evolved since the 1993 Australasian guideline (1). These changes have included the introduction of alternative assay methodologies, changed CsA formulation from Sandimmun to Neoral throughout Australasia, and alternatives to trough concentration (C0) monitoring, especially 2-hour concentration (C2) monitoring and associated validated dilution protocols to accurately quantitate the higher whole blood CsA concentrations. The revision was prepared following a recent survey of all Australasian CsA-monitoring laboratories (2) where discordant practices were evident.
Resumo:
This study compared an enzyme-linked immunosorbent assay (ELISA) to a liquid chromatography-tandem mass spectrometry (LC/MS/MS) technique for measurement of tacrolimus concentrations in adult kidney and liver transplant recipients, and investigated how assay choice influenced pharmacokinetic parameter estimates and drug dosage decisions. Tacrolimus concentrations measured by both ELISA and LC/MS/MS from 29 kidney (n = 98 samples) and 27 liver (n = 97 samples) transplant recipients were used to evaluate the performance of these methods in the clinical setting. Tacrolimus concentrations measured by the two techniques were compared via regression analysis. Population pharmacokinetic models were developed independently using ELISA and LC/MS/MS data from 76 kidney recipients. Derived kinetic parameters were used to formulate typical dosing regimens for concentration targeting. Dosage recommendations for the two assays were compared. The relation between LC/MS/MS and ELISA measurements was best described by the regression equation ELISA = 1.02 . (LC/MS/MS) + 0.14 in kidney recipients, and ELISA = 1.12 . (LC/MS/MS) - 0.87 in liver recipients. ELISA displayed less accuracy than LC/MS/MS at lower tacrolimus concentrations. Population pharmacokinetic models based on ELISA and LC/MS/MS data were similar with residual random errors of 4.1 ng/mL and 3.7 ng/mL, respectively. Assay choice gave rise to dosage prediction differences ranging from 0% to 30%. ELISA measurements of tacrolimus are not automatically interchangeable with LC/MS/MS values. Assay differences were greatest in adult liver recipients, probably reflecting periods of liver dysfunction and impaired biliary secretion of metabolites. While the majority of data collected in this study suggested assay differences in adult kidney recipients were minimal, findings of ELISA dosage underpredictions of up to 25% in the long term must be investigated further.
Resumo:
OBJECTIVE Because there is discordance between different immunoassay values for serum hGH, and because clinical state may not correlate with immunoreactive hGH, we have developed an assay to accurately measure serum hGH somatogenic bioactivity. The results of this assay were compared with the Elegance two-site ELISA assay across 135 patient samples in a variety of clinical states. DESIGN The somatogenic assay was based on stable expression of hGH receptor in the murine BaF line, allowing these cells to proliferate in response to hGH. To eliminate interference by other growth factors in serum, we created a specific antagonist of the hGH receptor (similar to Trovert or Pegvisomant) which allowed us to obtain a true measure of hGH somatogenic activity by subtraction of the activity in the presence of the antagonist. The assay was carried out in microtiter plates over 24 h, with oxidation of a chromogenic tetrazolium salt (MTT) as the endpoint. PATIENTS These encompassed a number of different clinical conditions related to short stature, including idiopathic short stature, neurosecretory dysfunction and renal failure, as well as obese patients on dietary restriction and normal volunteers. MEASUREMENTS In addition to the colourimetric (MTT) response to hGH, we measured free hGH by stripping out GHBP-bound hGH using beads coupled to a monoclonal antibody to the GHBP (GH binding protein). All samples were measured in both bioassay and ELISA assay. RESULTS This bioassay was sensitive (5 mU/l or 2 mug/l) and precise, and not subject to interference by the GHBP. There was a good correlation (r = 0.95) between bioactivity and immunoactivity across clinical states. There was, however, an increased bioactivity during secretory peaks (over 25 mU/l), which has been reported previously for the Nb2 bioassay. Free hGH did not correlate with clinical state. CONCLUSIONS Because the results of the Elegance ELISA and the bioassay correlate well, even though there is greater bioactivity at higher hormone concentrations, it is evident that an appropriate immunoassay is able to act as a reliable indicator for clinical assessment. In those rare cases where bio-inactive GH exists, our bioassay should provide an appropriate means to demonstrate this.
Resumo:
Objectives. Long-term, low-dose macrolide therapy is effective in the treatment of chronic rhinosinusitis. The mechanism of its anti-inflammatory effect and how this differs from corticosteroids remains unclear. The effect of clarithromycin and prednisolone on interleukin-5, interleukin-8, and granulocyte-macrophage colony-stimulating factor production by cultured chronic sinusitis nasal mucosa was examined in the study. Study Design and Methods. Nasal mucosa was obtained from 11 patients with chronic sinusitis. This tissue was cultured for 24 hours in the presence of clarithromycin or prednisolone at a variety of concentrations. Cytokine levels were determined by enzyme-linked immunoassay. Results. Clarithromycin and prednisolone each produced significant reductions in interleukin-5, interleukin-8, and granulocyte-macrophage colony-stimulating factor production. There was no significant difference between the effects of clarithromycin and prednisolone. Conclusion: Macrolide antibiotics are capable of inhibiting pro-inflammatory cytokine production in vitro and are as potent as prednisolone. This mechanism is likely to be at least partly responsible for the clinical efficacy of macrolide antibiotics in chronic rhinosinusitis. Key Words. Macrolide, prednisolone, sinusitis, enzyme-linked immunosorbent assay, cytokine.
Resumo:
A hidatidose, vulgarmente conhecida por quisto hidático, é causada pelos estados larvares do parasita Echinococcus granulosus. O seu diagnóstico baseia-se na clínica, na epidemiologia e nas técnicas imagiológicas, sendo suportado por testes serológicos. O tratamento mais comum é o cirúrgico, sendo importante o diagnóstico definitivo da doença antes da cirurgia, para se prevenir a disseminação dos quistos que pode ocorrer durante a mesma. Neste trabalho comparam-se dois métodos imunoserológicos para o diagnóstico da hidatidose: Enzyme-linked Immunosorbent Assay (ELISA) para pesquisa de Imunoglobulina G; e Fluoro-enzyme Immunoassay (FEIA) para pesquisa de Imunoglobulina E. Dos 55 indivíduos incluídos no estudo, todos em fase pré-operatória, 31% possuíam quisto hidático calcificado, 54,5% quisto hidático não calcificado e 14,5% não possuíam hidatidose, mas quistos simples. Os testes apresentaram a mesma especificidade (87,5%), sendo a sensibilidade do ELISA IgG mais baixa (63,8%) do que a do FEIA IgE (76,6%). Foi demonstrada uma boa correlação entre os dois métodos (r = 0,726, p < 0,05).
Resumo:
OBJECTIVE: Many business organizations in Brazil have adopted drug testing programs in the workplace since 1992. Rehabilitation, rather than layoff and disciplinary measures, has been offered as part of the Brazilian employee assistance programs. The purpose study is to profile drug abuse among company workers of different Brazilian geographical regions. METHODS: Urine samples of 12,700 workers from five geographical regions were tested for the most common illicit drugs of abuse in the country: marijuana, cocaine, and amphetamine. Enzyme multiplied immunoassay technique (EMIT) and gas chromatography coupled with mass spectrometry (GC/MS) were the techniques utilized for urine testing. The distribution of collected urine samples according to geographical regions was: 72.0% southeast, 13.8% northeast, 7.9% south, 5.7% central west and 0.6% north. RESULTS: Of all samples analyzed, 1.8% was found to be positive for drugs: 0.5% from the south region, 1.1% from northeast, 1.2% from central west, 1.3% from north, and 2.2% from southeast. Of these, 59.9% was marijuana, 17.7% cocaine, 14.6% amphetamine, and 7.7% associated drugs. CONCLUSIONS: The distribution of drugs found in the samples shows a regional variation. Marijuana, however, was found in all regions. Cocaine was seen only in central west and southeast regions. Amphetamine was found in northeast, central west, and southeast regions.
Resumo:
OBJECTIVE: To assess the relationship of blood lead and hemoglobin, zinc protoporphyrin, and ferritin concentrations in children. METHODS: A cross-sectional study was carried out in 136 anemic and non-anemic children from two rural villages near a lead smelter in Adrianópolis, Southern Brazil, from July to September 2001. Hemoglobin electrophoresis was performed to exclude children with hemoglobin variants and thalassemia syndromes associated with anemia. Lead was determined by atomic absorption spectrophotometry; hemoglobin by automated cell counting; zinc protoporphyrin by hematofluorometry; ferritin by chemiluminescence. Student's t-test, Mann-Whitney test, and the c² test were used to assess the significance of the differences between the variables investigated in anemic and non-anemic children. Stepwise multivariate linear regression analysis was performed using two models for anemic and non-anemic children respectively. RESULTS: Lead was negatively associated to hemoglobin (p<0.017) in the first model, and in the second model lead was positively associated to zinc protoporphyrin (p<0.004) after controlling for ferritin, age, sex, and per capita income. There was an inverse association between hemoglobin and blood lead in anemic children. It was not possible to confirm if anemic children had iron deficiency anemia or subclinical infection, considering that the majority (90.4%) had normal ferritin. CONCLUSIONS: The study detected a relationship between anemia and elevated blood lead concentrations. Further epidemiological studies are necessary to investigate the impact of iron nutritional interventions as an attempt to decrease blood lead in children.
Resumo:
There is an imminent need for rapid methods to detect and determine pathogenic bacteria in food products as alternatives to the laborious and time-consuming culture procedures. In this work, an electrochemical immunoassay using iron/gold core/shell nanoparticles (Fe@Au) conjugated with anti-Salmonella antibodies was developed. The chemical synthesis and functionalization of magnetic and gold-coated magnetic nanoparticles is reported. Fe@Au nanoparticles were functionalized with different self-assembled monolayers and characterized using ultraviolet-visible spectrometry, transmission electron microscopy, and voltammetric techniques. The determination of Salmonella typhimurium, on screen-printed carbon electrodes, was performed by square-wave anodic stripping voltammetry through the use of CdS nanocrystals. The calibration curve was established between 1×101 and 1×106 cells/mL and the limit of detection was 13 cells/mL. The developed method showed that it is possible to determine the bacteria in milk at low concentrations and is suitable for the rapid (less than 1 h) and sensitive detection of S. typhimurium in real samples. Therefore, the developed methodology could contribute to the improvement of the quality control of food samples.
Resumo:
Mucin-16 (MUC16) is the established ovarian cancer marker used to follow the disease during or after treatment for epithelial ovarian cancer. The emerging science of cancer markers also demands for the new sensitive detection methods. In this work, we have developed an electrochemical immunosensor for antigen MUC16 using gold nanoelectrode ensemble (GNEE) and ferrocene carboxylic acid encapsulated liposomes tethered with monoclonal anti-Mucin-16 antibodies ( MUC16). GNEEs were fabricated by electroless deposition of the gold within the pores of polycarbonate track-etched membranes. Afterwards, MUC16 were immobilized on preformed self-assembled monolayer of cysteamine on the GNEE via cross-linking with EDC-Sulfo-NHS. A sandwich immunoassay was performed on MUC16 functionalized GNEE with MUC16 and immunoliposomes. The differential pulse voltammetry was employed to quantify the faradic redox response of ferrocene carboxylic acid released from immunoliposomes. The dose–response curve for MUC16 concentration was found between the range of 0.001–300 U mL−1. The lowest detection limit was found to be 5 × 10−4 U mL−1 (S/N = 3). We evaluated the performance of this developed immunosensor with commercial ELISA assay by comparing results obtained from spiked serum samples and real blood serum samples from volunteers.
Resumo:
Bacterial food poisoning is an ever-present threat that can be prevented with proper care and handling of food products. A disposable electrochemical immunosensor for the simultaneous measurements of common food pathogenic bacteria namely Escherichia coli O157:H7 (E. coli), campylobacter and salmonella were developed. The immunosensor was fabricated by immobilizing the mixture of anti-E. coli, anticampylobacter and anti-salmonella antibodies with a ratio of 1:1:1 on the surface of the multiwall carbon nanotube-polyallylamine modified screen printed electrode (MWCNT-PAH/SPE). Bacteria suspension became attached to the immobilized antibodies when the immunosensor was incubated in liquid samples. The sandwich immunoassay was performed with three antibodies conjugated with specific nanocrystal ( -E. coli-CdS, -campylobacter-PbS and -salmonella-CuS) which has releasable metal ions for electrochemical measurements. The square wave anodic stripping voltammetry (SWASV) was employed to measure released metal ions from bound antibody nanocrystal conjugates. The calibration curves for three selected bacteria were found in the range of 1 × 103 – 5 × 105 cells mL−1 with the limit of detection (LOD) 400 cells mL−1 for salmonella, 400 cells mL−1 for campylobacter and 800 cells mL−1 for E. coli. The precision and sensitivity of this method show the feasibility of multiplexed determination of bacteria in milk samples.
Resumo:
Silica based nanostructured composite materials doped with luminol and cobalt(II) ion were synthesized and characterized, resulting in a highly chemiluminescent material in the presence of hydrogen peroxide. A detection system with the CL light guided from the reaction tube to the photomultiplier tube using a one millimeter glass optical fiber was developed and assessed. A linear response was observed using a semi-logarithm calibration between 50–2000 µM hydrogen peroxide with 1 µM as the limit of detection.
Resumo:
Anti-HAV was detected by enzyme - immunoassay in sera collected from 6 (18,75%) of 32 Didelphis marsupialis trapped in the Amazon region. No anti-HAV were found in the sera from 136 other wild animals, including small rodents, reptiles and other marsupials.
Resumo:
Hepatitis B markers were determined in 397 individuals from Niterói and 680 from Nova Iguaçu and prevalences of 9.1% (1.0% of HBsAg and 8.1% of anti HBs) and 11.1% (1.8% of HBsAg and 9.3% of antiHBs) were found, respectively. The comparative prevalence of both markers in relation to age showed a higher prevalence of HBsAg in the group 21-50 years old. Considering the antiHBs antibody, it was demostrated a gradual increase with age, reaching 14.9% in Niterói and 29.1% in Nova Iguaçu in individuals over 51 years old. For hepatitis A, in 259 samples from Niterói, equally distributed by age groups, an overall prevalence of 74.5% of anti-HAV antibodies was found. This prevalence increases gradually reaching 90.0% at age over thirty. In 254 samples from Nova Iguaçu analysed, a prevalence of 90.5% of antibodies was encountered when the same criteria of distribution of samples were used. This level of prevalence reached 90.0% already in the age over ten years old. The tests were performed by enzyme immunoassay with reagents prepared in our laboratory.
Resumo:
Sera from 299 fishermen 16 to 80 years old, residents in Cananeia and Iguape counties, southern cost of São Paulo State, Brazil, were studied in order to identify a possible association between the prevalence of specific antibodies to the hepatitis B virus (HBV) and exposure to haematophagus mosquitoes evaluated by the prevalence of arbovirus antibodies. This professional group presented the highest prevalence of arbovirus antibodies (54.1%) in past investigations carried out in this heavily forested region. Detection of antibody to hepatitis B core antigen (anti-HBc) in the sera was done by enzyme immunoassay (Roche). Prevalence of anti-HBc antibodies in this group was 31.4% (94/299) which is very high compared with 7.2% to 15.0% for different groups of healthy adults in State of São Paulo. No significant difference is observed between the prevalences of HBV antibodies in Iguape and Cananeia. Prevalence of anti-HBc and anti-arbovirus antibodies increases with age. There is a concordance in the distribution according to age groups of the frequency of anti-HBc and anti-arbovirus positive sera. Ag HBs was detected in 4% of the studied sera. These results support the hypothesis that the transmission of the hepatitis B virus and the arboviruses may be due to the same factor, one of the possibilities would be by anthropophilic mosquitoes.
Resumo:
Human epidermal growth factor receptor 2 (HER2) is a breast cancer biomarker that plays a major role in promoting breast cancer cell proliferation and malignant growth. The extracellular domain (ECD) of HER2 can be shed into the blood stream and its concentration is measurable in the serum fraction of blood. In this work an electrochemical immunosensor for the analysis of HER2 ECD in human serum samples was developed. To achieve this goal a screen-printed carbon electrode, modified with gold nanoparticles, was used as transducer surface. A sandwich immunoassay, using two monoclonal antibodies, was employed and the detection of the antibody–antigen interaction was performed through the analysis of an enzymatic reaction product by linear sweep voltammetry. Using the optimized experimental conditions the calibration curve (ip vs. log[HER2 ECD]) was established between 15 and 100 ng/mL and a limit of detection (LOD) of 4.4 ng/mL was achieved. These results indicate that the developed immunosensor could be a promising tool in breast cancer diagnostics, patient follow-up and monitoring of metastatic breast cancer since it allows quantification in a useful concentration range and has an LOD below the established cut-off value (15 ng/mL).