899 resultados para artificial embolism
Resumo:
Although associated with adverse outcomes in other cardiopulmonary diseases, limited evidence exists on the prognostic value of anaemia in patients with acute pulmonary embolism (PE). We sought to examine the associations between anaemia and mortality and length of hospital stay in patients with PE. We evaluated 14,276 patients with a primary diagnosis of PE from 186 hospitals in Pennsylvania, USA. We used random-intercept logistic regression to assess the association between anaemia at the time of presentation and 30-day mortality and discrete-time logistic hazard models to assess the association between anaemia and time to hospital discharge, adjusting for patient (age, gender, race, insurance type, clinical and laboratory variables) and hospital (region, size, teaching status) factors. Anaemia was present in 38.7% of patients at admission. Patients with anaemia had a higher 30-day mortality (13.7% vs. 6.3%; p <0.001) and a longer length of stay (geometric mean, 6.9 vs. 6.6 days; p <0.001) compared to patients without anaemia. In multivariable analyses, anaemia remained associated with an increased odds of death (OR 1.82, 95% CI: 1.60-2.06) and a decreased odds of discharge (OR 0.85, 95% CI: 0.82-0.89). Anaemia is very common in patients presenting with PE and is independently associated with an increased short-term mortality and length of stay.
Resumo:
We would like to comment this study recently published in JFS. It is a short technical note proposing an artificial aging technique for the dating of ballpoint pen inks. This is a very difficult and controversial topic, and we are worried about the nature of this paper. The authors propose several ideas to differentiate fast aging and slow aging inks, but their experimental data is not validly represented and/or discussed. The data is insufficient to draw any conclusions about any potential of the method for ink dating purposes. This lack of information on the subject must be filled before proposing such methods for practical caseworks. These are preliminary and unconvincing results from development research performed in a laboratory on controlled samples without due warnings about potential shortcomings. They cannot be used or even compared to results obtained in real situations on uncontrolled specimens of limited size, unknown composition and undefined storage conditions. This can leave an undeserved feeling that these methods are ready for implementation when the task of ensuring their scientific validity is still far away.
Resumo:
An artificial feeding system was used where citrated bovine blood was offerred to male and female Amblyomma cajennense. Vestiges of blood, sweat, hair and exfoliated skin were used as phago-stimulants placed on the surface of the silicone membrane. The ticks were collected, as engorged nymphs, from naturally infested equines, with the ecdysis occurring in the laboratory. Four hundred ticks were used, 50% being female, at three to four weeks post-ecdysis. Vestiges of blood on the silicone membrane were the most efficient phago-stimulant and the association of vestiges of blood and sweat residue smears yielded better results compared to the other phago-stimulants used
Resumo:
Two direct methods for the diagnosis of trichinellosis were compared: trichinoscopy and artificial digestion. Muscles from 17 wistar rats, orally infected with 500 Trichinella spiralis encysted larvae were examined. From each of the following muscles: diaphragm, tongue, masseters, intercostals, triceps brachialis and cuadriceps femoralis, 648,440 larvae from 1 g samples were recovered. The linear correlation between trichinoscopy and artificial digestion was very high and significant (r=0.94, p< 0.0001), showing that both methods for the detection of muscular larvae did not differ significantly. In both methods, significant differences were found in the distribution of larvae per gramme of muscle
Resumo:
Ventricular assist devices (VADs) are used in treatment for terminal heart failure or as a bridge to transplantation. We created biVAD using the artificial muscles (AMs) that supports both ventricles at the same time. We developed the test bench (TB) as the in vitro evaluating system to enable the measurement of performance. The biVAD exerts different pressure between left and right ventricle like the heart physiologically does. The heart model based on child's heart was constructed in silicone. This model was fitted with the biVAD. Two pipettes containing water with an ultrasonic sensor placed on top of each and attached to ventricles reproduced the preload and the after load of each ventricle by the real-time measurement of the fluid height variation proportionally to the exerted pressure. The LabVIEW software extrapolated the displaced volume and the pressure generated by each side of our biVAD. The development of a standardized protocol permitted the validation of the TB for in vitro evaluation, measurement of the performances of the AM biVAD herein, and reproducibility of data.
Resumo:
This paper presents the Juste-Neige system for predicting the snow height on the ski runs of a resort using a multi-agent simulation software. Its aim is to facilitate snow cover management in order to i) reduce the production cost of artificial snow and to improve the profit margin for the companies managing the ski resorts; and ii) to reduce the water and energy consumption, and thus to reduce the environmental impact, by producing only the snow needed for a good skiing experience. The software provides maps with the predicted snow heights for up to 13 days. On these maps, the areas most exposed to snow erosion are highlighted. The software proceeds in three steps: i) interpolation of snow height measurements with a neural network; ii) local meteorological forecasts for every ski resort; iii) simulation of the impact caused by skiers using a multi-agent system. The software has been evaluated in the Swiss ski resort of Verbier and provides useful predictions.
Resumo:
BACKGROUND: The optimal length of stay (LOS) for patients with pulmonary embolism (PE) is unknown. Although reducing LOS is likely to save costs, the effects on patient safety are unclear. We sought to identify patient and hospital factors associated with LOS and assess whether LOS was associated with postdischarge mortality. METHODS: We evaluated patients discharged with a primary diagnosis of PE from 186 acute care hospitals in Pennsylvania (January 2000 through November 2002). We used discrete survival models to examine the association between (1) patient and hospital factors and the time to discharge and (2) LOS and postdischarge mortality within 30 days of presentation, adjusting for patient and hospital factors. RESULTS: Among 15 531 patient discharges with PE, the median LOS was 6 days, and postdischarge mortality rate was 3.3%. In multivariate analysis, patients from Philadelphia were less likely to be discharged on a given day (odds ratio [OR], 0.82; 95% confidence interval [CI], 0.73-0.93), as were black patients (OR, 0.88; 95% CI, 0.82-0.94).The odds of discharge decreased notably with greater patient severity of illness and in patients without private health insurance. Adjusted postdischarge mortality was significantly higher for patients with an LOS of 4 days or less (OR, 1.55; 95% CI, 1.21-2.00) relative to those with an LOS of 5 to 6 days. CONCLUSIONS: Several hospital and patient factors were independently associated with LOS. Patients with a very short LOS had greater postdischarge mortality relative to patients with a typical LOS, suggesting that physicians may inappropriately select patients with PE for early discharge who are at increased risk of complications
Resumo:
Objectives: The AMS 800TM is the current artificial urinary sphincter (AUS) for incontinence due to intrinsic sphincter deficiency. Despite good clinical results, technical failures inherent to the hydraulic mechanism or urethral ischemic injury contribute to revisions up to 60%. We are developing an electronic AUS, called ARTUS to overcome the rigors of AMS. The objective of this study was to evaluate the technical efficacy and tissue tolerance of the ARTUS system in an animal model.Methods: The ARTUS is composed by three parts: the contractile unit, a series of rings and an integrated microprocessor. The contractile unit is made of Nitinol fibers. The rings are placed around the urethra to control the flow of urine by squeezing the urethra. They work in a sequential alternative mode and are controlled by a microprocessor. In the first phase a three-rings device was used while in the second phase a two-rings ARTUS was used. The device was implanted in 14 sheep divided in two groups of six and eight animals for study purpose. The first group aimed at bladder leak point pressure (BLPP) measurement and validation of the animal model; the second group aimed at verifying mid-term tissue tolerance by explants at twelve weeks. General animal tolerance was also evaluated.Results: The ARTUS system implantation was uneventful. When the system was activated, the BLPP was measured at 1.038±0.044 bar (mean±SD). Urethral tissue analysis did not show significant morphological changes. No infection and no sign of discomfort were noted in animals at 12 weeks.Conclusions: The ARTUS proved to be effective in continence achievement in this study. Histological results support our idea that a sequential alternative mode can avoid urethral atrophy and ischemia. Further technical developments are needed to verify long-term outcome and permit human use.
Resumo:
A shift from large to small average sizes was observed in Triatoma infestans and Rhodnius domesticus between field and domestic (or laboratory) conditions of life. It was more pronounced in the female specimens, leading to a subsequent reduction of sexual size dimorphism. This feature is discussed in terms of genetic and populational changes occurring from natural to artificial habitats, in particular those related to population densities. Sexual size dimorphism is then recommended as a new character to be used in the study of species of Triatominae adapting to domestic ecotopes.
Resumo:
The females of the two species of the Lutzomyia intermedia complex can be easily distinguished, but the males of each species are quite similar. The ratios between the extra-genital and the genital structures of L. neivai are larger than those of L. intermedia s. s., according to ANOVA. An artificial neural network was trained with a set of 300 examples, randomly taken from a sample of 358 individuals. The input vectors consisted of several ratios between some structures of each insect. The model was tested on the remaining 58 insects, 56 of which (96.6%) were correctly identified. This ratio of success can be considered remarkable if one takes into account the difficulty of attaining comparable results using traditional statistical techniques.
Resumo:
WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: The AMS 800 urinary control system is the gold standard for the treatment of urinary incontinence due to sphincter insufficiency. Despite excellent functional outcome and latest technological improvements, the revision rate remains significant. To overcome the shortcomings of the current device, we developed a modern electromechanical artificial urinary sphincter. The results demonstrated that this new sphincter is effective and well tolerated up to 3 months. This preliminary study represents a first step in the clinical application of novel technologies and an alternative compression mechanism to the urethra. OBJECTIVES: To evaluate the effectiveness in continence achievement of a new electromechanical artificial urinary sphincter (emAUS) in an animal model. To assess urethral response and animal general response to short-term and mid-term activation of the emAUS. MATERIALS AND METHODS: The principle of the emAUS is electromechanical induction of alternating compression of successive segments of the urethra by a series of cuffs activated by artificial muscles. Between February 2009 and May 2010 the emAUS was implanted in 17 sheep divided into three groups. The first phase aimed to measure bladder leak point pressure during the activation of the device. The second and third phases aimed to assess tissue response to the presence of the device after 2-9 weeks and after 3 months respectively. Histopathological and immunohistochemistry evaluation of the urethra was performed. RESULTS: Bladder leak point pressure was measured at levels between 1091 ± 30.6 cmH2 O and 1244.1 ± 99 cmH2 O (mean ± standard deviation) depending on the number of cuffs used. At gross examination, the explanted urethra showed no sign of infection, atrophy or stricture. On microscopic examination no significant difference in structure was found between urethral structure surrounded by a cuff and control urethra. In the peripheral tissues, the implanted material elicited a chronic foreign body reaction. Apart from one case, specimens did not show significant presence of lymphocytes, polymorphonuclear leucocytes, necrosis or cell degeneration. Immunohistochemistry confirmed the absence of macrophages in the samples. CONCLUSIONS: This animal study shows that the emAUS can provide continence. This new electronic controlled sequential alternating compression mechanism can avoid damage to urethral vascularity, at least up to 3 months after implantation. After this positive proof of concept, long-term studies are needed before clinical application could be considered.
Resumo:
Pulmonary embolism (PE) is traditionally treated in hospital. Growing evidence from non randomized prospective studies suggests that a substantial proportion of patients with non-massive PE might be safely treated in the outpatient setting using low molecular weight heparins. Based on this evidence, professional societies started to recommend outpatient care for selected patients with non-massive PE. Despite these recommendations, outpatient treatment of non-massive PE appears to be uncommon in clinical practice. The major barriers to PE outpatient care are, firstly, the uncertainty as how to identify low risk patients with PE who are candidates for outpatient care and secondly the lack of high quality evidence from randomized trials demonstrating the safety of PE outpatient care compared to traditional inpatient management. Also, although clinical prognostic models, echocardiography and cardiac biomarkers accurately identify low risk patients with PE in prospective studies, the benefit of risk stratification strategies based on these instruments should be demonstrated in prospective management studies and clinical trials before they can be implemented as decision aids to guide PE outpatient treatment. Before high quality evidence documenting the safety of an outpatient treatment approach is published, outpatient management of non-massive PE cannot be generally recommended.
Resumo:
Creació d'un joc del tipus Arcade beat'em up en 2D utilitzant escenaris amb una certa profunditat de moviment i dotant als personatges no jugadors i altres objectes d'Intel·ligència Artificial de manera que el seu comportament no sigui sempre lineal i aprofitant-ho per afegir nivells de dificultat.