848 resultados para Signal spectrum


Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the past 15 years, emergence and dissemination of third-generation cephalosporins resistance in nosocomial Enterobacteriaceae became a serious problem worldwide, due to the production of extended-spectrum-β-lactamases (ESBLs). The aim of this study was to investigate among the presence of ESBL-producing enterobacteria among Portuguese clinical isolates nearby Spain, to investigate the antimicrobial susceptibility patterns and to compare the two countries. The β-lactamases genes, blaTEM, blaSHV and blaCTX-M were detected by molecular methods. Among the ESBL-producing isolates it was found extraordinary levels (98.9%) of resistance to the fourth-generation cephalosporin Cefepime. These findings point to the need of reevaluate the definition of ESBL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Myocardial perfusion-gated-SPECT (MP-gated-SPECT) imaging often shows radiotracer uptake in abdominal organs. This accumulation interferes frequently with qualitative and quantitative assessment of the infero-septal region of myocardium. The objective of this study is to evaluate the effect of ingestion of different fat content on the reduction of extra-myocardial uptake and to improve MP-gated-SPECT image quality. In this study, 150 patients (65 ^ 18 years) who were referred for MP-gated-SPECT underwent a 1-day-protocol including imaging after stress (physical or pharmacological) and resting conditions. All patients gave written informed consent. Patients were subdivided into five groups: GI, GII, GIII, GIV and GV. In the first four groups, patients ate two chocolate bars with different fat content. Patients in GV – control group (CG) – had just water. Uptake indices (UI) of myocardium (M)/liver(L) and M/stomach–proximal bowel(S) revealed lower UI of M/S at rest in all groups. Both stress and rest studies using different food intake indicate that patients who ate chocolate with different fat content showed better UI of M/L than the CG. The UI of M/L and M/S of groups obtained under physical stress are clearly superior to that of groups obtained under pharmacological stress. These differences are only significant in patients who ate high-fat chocolate or drank water. The analysis of all stress studies together (GI, GII, GIII and GIV) in comparison with CG shows higher mean ranks of UI of M/L for those who ate high-fat chocolate. After pharmacological stress, the mean ranks of UI of M/L were higher for patients who ate high- and low-fat chocolate. In conclusion, eating food with fat content after radiotracer injection increases, respectively, the UI of M/L after stress and rest in MP-gated-SPECT studies. It is, therefore, recommended that patients eat a chocolate bar after radiotracer injection and before image acquisition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glucose sensing is an issue with great interest in medical and biological applications. One possible approach to glucose detection takes advantage of measuring changes in fluorescence resonance energy transfer (FRET) between a fluorescent donor and an acceptor within a protein which undergoes glucose-induced changes in conformation. This demands the detection of fluorescent signals in the visible spectrum. In this paper we analyzed the emission spectrum obtained from fluorescent labels attached to a protein which changes its conformation in the presence of glucose using a commercial spectrofluorometer. Different glucose nanosensors were used to measure the output spectra with fluorescent signals located at the cyan and yellow bands of the spectrum. A new device is presented based on multilayered a-SiC:H heterostructures to detect identical transient visible signals. The transducer consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n heterostructure optimized for the detection of the fluorescence resonance energy transfer between fluorophores with excitation in the violet (400 nm) and emissions in the cyan (470 nm) and yellow (588 nm) range of the spectrum. Results show that the device photocurrent signal measured under reverse bias and using appropriate steady state optical bias, allows the separate detection of the cyan and yellow fluorescence signals presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The transducer consists of a semiconductor device based on two stacked -i-n heterostructures that were designed to detect the emissions of the fluorescence resonance energy transfer between fluorophores in the cyan (470 nm) and yellow (588 nm) range of the spectrum. This research represents a preliminary study on the use of such wavelength-sensitive devices as photodetectors for this kind of application. The device was characterized through optoelectronic measurements concerning spectral response measurements under different electrical and optical biasing conditions. To simulate the fluorescence resonance energy transfer (FRET) pairs, a chromatic time-dependent combination of cyan and yellow wavelengths was applied to the device. The generated photocurrent was measured under reverse and forward bias to read out the output photocurrent signal. A different wavelength-biasing light was also superimposed. Results show that under reverse bias, the photocurrent signal presents four separate levels, each one assigned to the different wavelength combinations of the FRET pairs. If a blue background is superimposed, the yellow channel is enhanced and the cyan suppressed, while under red irradiation, the opposite behavior occurs. So, under suitable biasing light, the transducer is able to detect separately the cyan and yellow fluorescence pairs. An electrical model, supported by a numerical simulation, supports the transduction mechanism of the device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glucose sensing is an issue with great interest in medical and biological applications. One possible approach to glucose detection takes advantage of measuring changes in fluorescence resonance energy transfer (FRET) between a fluorescent donor and an acceptor within a protein which undergoes glucose-induced changes in conformation. This demands the detection of fluorescent signals in the visible spectrum. In this paper we analyzed the emission spectrum obtained from fluorescent labels attached to a protein which changes its conformation in the presence of glucose using a commercial spectrofluorometer. Different glucose nanosensors were used to measure the output spectra with fluorescent signals located at the cyan and yellow bands of the spectrum. A new device is presented based on multilayered a-SiC:H heterostructures to detect identical transient visible signals. The transducer consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n heterostructure optimized for the detection of the fluorescence resonance energy transfer between fluorophores with excitation in the violet (400 nm) and emissions in the cyan (470 nm) and yellow (588 nm) range of the spectrum. Results show that the device photocurrent signal measured under reverse bias and using appropriate steady state optical bias, allows the separate detection of the cyan and yellow fluorescence signals. (C) 2013 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An Electrocardiogram (ECG) monitoring system deals with several challenges related with noise sources. The main goal of this text was the study of Adaptive Signal Processing Algorithms for ECG noise reduction when applied to real signals. This document presents an adaptive ltering technique based on Least Mean Square (LMS) algorithm to remove the artefacts caused by electromyography (EMG) and power line noise into ECG signal. For this experiments it was used real noise signals, mainly to observe the di erence between real noise and simulated noise sources. It was obtained very good results due to the ability of noise removing that can be reached with this technique. A recolha de sinais electrocardiogr a cos (ECG) sofre de diversos problemas relacionados com ru dos. O objectivo deste trabalho foi o estudo de algoritmos adaptativos para processamento digital de sinal, para redu c~ao de ru do em sinais ECG reais. Este texto apresenta uma t ecnica de redu c~ao de ru do baseada no algoritmo Least Mean Square (LMS) para remo c~ao de ru dos causados quer pela actividade muscular (EMG) quer por ru dos causados pela rede de energia el ectrica. Para as experiencias foram utilizados ru dos reais, principalmente para aferir a diferen ca de performance do algoritmo entre os sinais reais e os simulados. Foram conseguidos bons resultados, essencialmente devido as excelentes caracter sticas que esta t ecnica tem para remover ru dos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A eletromiografia é, hoje em dia, uma das técnicas mais utilizadas no estudo dos músculos, estando presente em áreas como a medicina, a biomecânica e a fisiologia, possibilitando o desenvolvimento científico e contribuindo para proporcionar melhorias na qualidade da vida humana. Sendo assim, este trabalho apresenta um protótipo de um aparelho de aquisição de sinais eletromiográficos, explicando também toda a teoria, técnicas, componentes utilizadas e softwares que estiveram presentes na sua implementação. De uma forma sucinta, para a aquisição do sinal eletromiográfico usou-se uma placa de aquisição NI-USB 6009 e para a visualização do mesmo recorreu-se ao software LabVIEW. Para validar o sinal adquirido com o equipamento desenvolvido, utilizou-se um outro equipamento, o Biopac MP36 Student Lab System, fazendo-se assim recolhas de sinais eletromiográficos com ambos os equipamentos. Os sinais recolhidos pelos dois equipamentos foram analisados no software Acknowledge 3.9.0 (Biopac Systems, Inc.), podendo observar-se os espetros de frequência correspondentes a cada sinal e retirar valores para posterior análise estatística. Feita essa análise, concluiu-se que não foram detetadas diferenças significativas entre os sinais eletromiográficos recolhidos com ambos os equipamentos, validando-se assim, o equipamento desenvolvido.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Independent component analysis (ICA) has recently been proposed as a tool to unmix hyperspectral data. ICA is founded on two assumptions: 1) the observed spectrum vector is a linear mixture of the constituent spectra (endmember spectra) weighted by the correspondent abundance fractions (sources); 2)sources are statistically independent. Independent factor analysis (IFA) extends ICA to linear mixtures of independent sources immersed in noise. Concerning hyperspectral data, the first assumption is valid whenever the multiple scattering among the distinct constituent substances (endmembers) is negligible, and the surface is partitioned according to the fractional abundances. The second assumption, however, is violated, since the sum of abundance fractions associated to each pixel is constant due to physical constraints in the data acquisition process. Thus, sources cannot be statistically independent, this compromising the performance of ICA/IFA algorithms in hyperspectral unmixing. This paper studies the impact of hyperspectral source statistical dependence on ICA and IFA performances. We conclude that the accuracy of these methods tends to improve with the increase of the signature variability, of the number of endmembers, and of the signal-to-noise ratio. In any case, there are always endmembers incorrectly unmixed. We arrive to this conclusion by minimizing the mutual information of simulated and real hyperspectral mixtures. The computation of mutual information is based on fitting mixtures of Gaussians to the observed data. A method to sort ICA and IFA estimates in terms of the likelihood of being correctly unmixed is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chpater in Book Proceedings with Peer Review Second Iberian Conference, IbPRIA 2005, Estoril, Portugal, June 7-9, 2005, Proceedings, Part II

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O diagnóstico de máquinas elétricas pela análise de vibração é utilizado num plano de manutenção, onde é dado a conhecer a “real condição do equipamento”, e surgiu da necessidade de detetar vibrações indesejáveis nas máquinas elétricas, de uma forma simples e com custos acessíveis. Numa fase inicial é obtido um sinal correspondente á vibração da máquina, recorrendo a um acelerômetro, que dependendo da aceleração da máquina, constrói uma forma de onda correspondente. A forma de onda fica guardada em formato de áudio *.wav. Posteriormente, em software Matlab o ficheiro *.wav irá ser carregado, e comparado com o ficheiro *.wav original da máquina. Ao comparar os ficheiros o software analisa o espectro original da máquina através da transformada de Fourier, com o espectro atual. Se este espectro sair do intervalo de segurança, o software deteta nesse espectro a origem da vibração, pois cada vibração tem uma frequência associada. Percorridos os passos descritos, o software disponibiliza ao utilizador as respetivas formas de onda e todo o restante diagnóstico de forma a uma possível intervenção antecipada da avaria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Applications involving biosignals, such as Electrocardiography (ECG), are becoming more pervasive with the extension towards non-intrusive scenarios helping targeting ambulatory healthcare monitoring, emotion assessment, among many others. In this study we introduce a new type of silver/silver chloride (Ag/AgCl) electrodes based on a paper substrate and produced using an inkjet printing technique. This type of electrodes can increase the potential applications of biosignal acquisition technologies for everyday life use, given that there are several advantages, such as cost reduction and easier recycling, resultant from the approach explored in our work. We performed a comparison study to assess the quality of this new electrode type, in which ECG data was collected with three types of Ag/AgCl electrodes: i) gelled; ii) dry iii) paper-based inkjet printed. We also compared the performance of each electrode when acquired using a professional-grade gold standard device, and a low cost platform. Experimental results showed that data acquired using our proposed inkjet printed electrode is highly correlated with data obtained through conventional electrodes. Moreover, the electrodes are robust to high-end and low-end data acquisition devices. Copyright © 2014 SCITEPRESS - Science and Technology Publications. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper the viability of an integrated wavelength optical filter and photodetector for visible light communication (VLC) is discussed. The proposed application uses indoor warm light lamps lighting accomplished by ultra-bright light-emitting diodes (LEDs) pulsed at frequencies higher than the ones perceived by the human eye. The system was analyzed at two different wavelengths in the visible spectrum (430 nm and 626 nm) with variable optical intensities. The signals were transmitted into free space and measured using a multilayered photodetector based on a-SiC:H/a-Si:H. The detector works as an optical filter with controlled wavelength sensitivity through the use of optical bias. The output photocurrent was measured for different optical intensities of the transmitted optical signal and the extent of each signal was tested. The influence of environmental fluorescent lighting was also analysed in order to test the strength of the system. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.