998 resultados para Score Tests


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Speech understanding disorders in the elderly may be due to peripheral or central auditory dysfunctions. Asymmetry of results in dichotic testing increases with age, and may reflect on a lack of inter-hemisphere transmission and cognitive decline. Aim: To investigate auditory processing of aged people with no hearing complaints. Study design: clinical prospective. Materials and Methods: Twenty-two voluntary individuals, aged between 55 and 75 years, were evaluated. They reported no hearing complaints and had maximal auditory thresholds of 40 dB HL until 4 KHz, 80% of minimal speech recognition scores and peripheral symmetry between the ears. We used two kinds of tests: speech in noise and dichotic alternated dissyllables (SSW). Results were compared between males and females, right and left ears and between age groups. Results: There were no significant differences between genders, in both tests. Their Left ears showed worse results, in the competitive condition of SSW. Individuals aged 65 or older had poorer performances than those aged 55 to 64. Conclusion: Central auditory tests showed worse performance with aging. The employment of a dichotic test in the auditory evaluation setting in the elderly may help in the early identification of degenerative processes, which are common among these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to determine the relationship among body weight (BW), body condition score (BCS) and rump fat thickness (RFAT) measured by ultrasonography, and validate the relationship between BCS and RFAT over the time. Two hundred sixty and six Nelore cows had their BW, BCS and RFAT evaluated at five different moments during the production cycle: M1) weaning: M2) parturition, M3) 42 days post-partum; M4) 82 days postpartum and M5) 112 days post-partum. A BCS value was attributed for each cow following a I to 5 points scale. Ultrasonographic images for RFAT measurement were obtained using a 3.5 MHz linear transducer. Images were immediately analyzed as soon as they were formed and frozen. Body condition scores and ultrasound measurements were collected on the same day by a single trained technician. The relationship between BCS and RFAT values was investigated by regression models. The analysis of similarity among the five obtained models was performed using the proc MIXED from SAS and the correlations among variables were analyzed with proc CORR from SAS. The BCS was able to predict RFAT in Nelore cows in all different moments evaluated. Also, it was shown that BCS presented high correlation (r=0.82 to 0.93) and relationship (R(2) = 0.73 to 0.92) with RFAT. However, both BCS and RFAT showed low correlation (r=0.37 to 0.50) and relationship (R(2) = 0.13 to 0.25) with BW. The BCS classification by visual method using a 1 to 5 point scale, was able to predict the RFAT in Nelore cows over the time. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The objective of this in vitro study was to compare the degree of microleakage of composite restorations performed by lasers and conventional drills associated with two adhesive systems. Materials and Methods: Sixty bovine teeth were divided into 6 groups (n = 10). The preparations were performed in groups 1 and 2 with a high-speed drill (HID), in groups 3 and 5 with Er:YAG laser, and in groups 4 and 6 with Er,Cr:YSGG laser. The specimens were restored with resin composite associated with an etch-and-rinse two-step adhesive system (Single Bond 2 [SB]) (groups 1, 3, 4) and a self-etching adhesive (One-Up Bond F [OB]) (groups 2, 5, 6). After storage, the specimens were polished, thermocycled, immersed in 50% silver nitrate tracer solution, and then sectioned longitudinally. The specimens were placed under a stereomicroscope (25X) and digital images were obtained. These were evaluated by three blinded evaluators who assigned a microleakage score (0 to 3). The original data were submitted to Kruskal-Wallis and Mann-Whitney statistical tests. Results: The occlusal/enamel margins demonstrated no differences in microleakage for all treatments (p > 0.05). The gingival/dentin margins presented similar microleakage in cavities prepared with Er:YAG, Er,Cr:YSGG, and HD using the etch-and-rinse two-step adhesive system (SB) (p > 0.05); otherwise, both Er:YAG and Er,Cr:YSGG lasers demonstrated lower microleakage scores with OB than SB adhesive (p < 0.05). Conclusion: The microleakage score at gingival margins is dependent on the interaction of the hard tissue removal tool and the adhesive system used. The self-etching adhesive system had a lower microleakage score at dentin margins for cavities prepared with Er:YAG and Er,Cr:YSGG than the etch-and-rinse two-step adhesive system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The literature shows contradictory results regarding the role of composite shrinkage and elastic modulus as determinants of polymerization stress. The present study aimed at a better understanding of the test mechanics that could explain such divergences among studies. The hypothesis was that the effects of composite shrinkage and elastic modulus on stress depend upon the compliance of the testing system. A commonly used test apparatus was simulated by finite element analysis, with different compliance levels defined by the bonding substrate (steel, glass, composite, or acrylic). Composites with moduli between 1 and 12 GPa and shrinkage values between 0.5% and 6% were modeled. Shrinkage was simulated by thermal analogy. The hypothesis was confirmed. When shrinkage and modulus increased simultaneously, stress increased regardless of the substrate. However, if shrinkage and modulus were inversely related, their magnitudes and interaction with rod material determined the stress response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The aim of this study was to evaluate the ability of bond strength tests to accurately measure the bond strength of fiber posts luted into root canals Materials and Methods The test methods studied were hourglass microtensile (HM), push-out (PS), modified push out (MP) and pull out (PL) The evaluated parameters were bond strength values, reliability (using Weibull analysis), failure mode (using confocal microscopy), and stress distribution (using finite element analysis) Forty human intact single rooted and endodontically treated teeth were divided into four groups Each group was assigned one of the test methods The samples in the HM and PS groups were 1 0 +/- 0 1 mm thick, the HM samples were hourglass shaped and the PS samples were disk shaped For the PL and MP groups, each 1 mm dentin slice was luted with a fiber post piece Three dimensional models of each group were made and stress was analyzed based on Von Mises criteria Results PL provided the highest values of bond strength followed by MP both of which also had greater amounts of adhesive failures PS showed the highest frequency of cohesive failures MP showed a more homogeneous stress distribution and a higher Weibull modulus Conclusion The specimen design directly influences the biomechanical behavior of bond strength tests

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To evaluate the biaxial and short-beam uniaxial strength tests applied to resin composites based upon their Weibull parameters, fractographic features and stress distribution. Methods. Disk- (15 mm x 1 mm) and beam-shaped specimens (10 mm x 2 mm x 1 mm) of three commercial composites (Concept/Vigodent, CA; Heliomolar/Ivoclar-Vivadent, HE; Z250/3M ESPE, FZ) were prepared. After 48h dry storage at 37 degrees C, disks and beams were submitted to piston-on-three-balls (BI) and three-point bending (UNI) tests, respectively. Data were analyzed by Weibull statistics. Fractured surfaces were observed under stereomicroscope and scanning electron microscope. Maximum principal stress (sigma(1)) distribution was determined by finite element analysis (FEA). Maximum sigma(1-BI) and sigma(1-UNI) were compared to FZ strengths calculated by applying the average failure loads to the analytical equations (sigma(a-BI) and sigma(a-UNI)). Results. For BI, characteristic strengths were: 169.9a (FZ), 122.4b (CA) and 104.8c (HE), and for UNI were: 160.3a (FZ), 98.2b (CA) and 91.6b (HE). Weibull moduli ( m) were similar within the same test. CA and HE presented statistically higher m for BI. Surface pores ( BI) and edge flaws ( UNI) were the most frequent fracture origins. sigma(1-BI) was 14% lower than sigma(a-BI.) sigma(1-UNI) was 43% higher than sigma(a-UNI). Significance. Compared to the short-beam uniaxial test, the biaxial test detected more differences among composites and displayed less data scattering for two of the tested materials. Also, biaxial strength was closer to the material`s strength estimated by FEA. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stress distributions in torsion and wire-loop shear tests were compared using three-dimensional (3-D) linear-elastic finite element method, in an attempt to predict the ideal conditions for testing adhesive strength of dental resin composites to dentin. The torsion test presented lower variability in stress concentration at the adhesive interface with changes in the proportion adhesive thickness/resin composite diameter, as well as lower variability with changes in the resin composite elastic modulus. Moreover, the torsion test eliminated variability from changes in loading distance, and reduced the cohesive fracture tendency in the dentin. The torsion test seems to be more appropriate than wire-loop shear test for testing the resin composite-tooth interface strength. (c) Koninklijke Brill NV, Leiden, 2009

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To compare the response of human dental pulp capped with a mineral trioxide aggregate (MTA) and Ca(OH)(2) powder. Methods and Material: Pulp exposures were performed on the occlusal floor of 40 permanent premolars. The pulp was then capped with either Ca(OH)(2) powder (CH) or MTA and restored with resin composite. After 30 days (groups CH30 and MTA30) and 60 days (groups CH60 and MTA60), the teeth were extracted and processed for HE and categorized in a histological score system. The data were subjected to Kruskal-Wallis and Conover tests (alpha=0.05). Results: In regard to dentin bridge formation, CH30 showed a tendency towards superior performance compared to MTA30 (p>0.05), although the products showed comparable results at day 60. In the item ""Inflammation"" and ""General State of the Pulp"" (p>0.05), CH showed a tendency towards presenting a higher inflammatory response. In the item ""Other Pulpal Findings,"" MTA and Ca(OH)(2) showed equal and excellent performance after 30 and 60 days (p>0.05). Conclusion: After 30 days, Ca(OH)(2) powder covered with calcium hydroxide cement showed faster hard tissue bridge formation compared to MTA. After 60 days, Ca(OH)(2) powder or NITA materials showed a similar and excellent histological response with the formation of a hard tissue bridge in almost all cases with low inflammatory infiltrate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An important feature of some conceptual modelling grammars is the features they provide to allow database designers to show real-world things may or may not possess a particular attribute or relationship. In the entity-relationship model, for example, the fact that a thing may not possess an attribute can be represented by using a special symbol to indicate that the attribute is optional. Similarly, the fact that a thing may or may not be involved in a relationship can be represented by showing the minimum cardinality of the relationship as zero. Whether these practices should be followed, however, is a contentious issue. An alternative approach is to eliminate optional attributes and relationships from conceptual schema diagrams by using subtypes that have only mandatory attributes and relationships. In this paper, we first present a theory that led us to predict that optional attributes and relationships should be used in conceptual schema diagrams only when users of the diagrams require a surface-level understanding of the domain being represented by the diagrams. When users require a deep-level understanding, however, optional attributes and relationships should not be used because they undermine users' abilities to grasp important domain semantics. We describe three experiments which we then undertook to test our predictions. The results of the experiments support our predictions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Research has suggested that packable resin-based composites inserted with a placement technique similar to amalgam condensation can reduce the sensitivity associated with posterior restorations. The authors evaluated the clinical performance, including associated sensitivity, of two packable composites in a randomized five-year clinical trial. Methods. A single operator randomly placed two restorations in each of 33 patients: one restoration consisting of Alert (Jeneric/Pentron, Wallingford, Conn.) and the other consisting of SureFil (Dentsply/Caulk, Milford, Del.). There were 30 Class I and 36 Class II restorations. Two independent evaluators evaluated the restorations by using modified U.S.; Public Health Service criteria. The authors analyzed data by means of the Fisher, chi(2) and McNemar tests at P < .05. Results. Of 60 restorations evaluated at five years, two Class II restorations (one SureFil, one Alert) failed. All other restorations received the highest score possible for sensitivity and vitality. The only difference between the composites at the five-year recall was the significantly better surface texture of SureFil. The authors observed significantly different scores between the baseline and at five years for marginal discoloration (Alert and SureFil), surface texture (Alert and SureFil) and color (SureFil). Conclusions. Both packable resin-based composites showed excellent durability during the five-year follow-up. Clinical Implications. The investigated resin-based composites are suitable for posterior restorations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The diagnostic value of tests for antimyeloperoxidase antibodies (anti-MPO) for systemic vasculitis is less established than that for cytoplasmic antineutrophil cytoplasmic antibody (cANCA)/antiproteinase 3 antibodies (anti-PR3). Controversy exists regarding the optimal utilization of indirect immunofluorescence (IIF) ANCA testing versus antigen-specific ANCA testing. To summarize the pertinent data, we conducted a metaanalysis examining the diagnostic value of ANCA testing systems that include assays for anti-MPO. Methods. We performed a structured Medline search and reference list review. Target articles in the search strategy were those reporting the diagnostic value of immunoassays for anti-MPO for the spectrum of systemic necrotizing vasculitides that includes Wegener's granulomatosis, microscopic polyangiitis, the Churg-Strauss syndrome, and isolated pauci-immune necrotizing or crescentic glomerulonephritis, regardless of other types of ANCA tests. Inclusion criteria required specification of a consecutive or random patient selection method and the use of acceptable criteria for the diagnosis of vasculitis exclusive of ANCA test results. Weighted pooled summary estimates of sensitivity and specificity were calculated for anti-MPO alone, anti-MPO + perinuclear ANCA (pANCA), and anti-MPO/pANCA + anti-PR3/cANCA. Results. Of 457 articles reviewed, only 7 met the selection criteria. Summary estimates of sensitivity and specificity (against disease controls only) of assays for anti-MPO for the diagnosis of systemic necrotizing vasculitides were 37.1% (confidence interval 26.6% to 47.6%) and 96.3% (CI 94.1% to 98.5%), respectively. When the pANCA pattern by IIF was combined with anti-MPO testing, the specificity improved to 99.4%, with a lower sensitivity, 31.5%. The combined ANCA testing system (anti-PR3/cANCA + anti-MPO/pANCA) increased the sensitivity to 85.5% with a specificity of 98.6%. Conclusion. These results suggest that while anti-MPO is relatively specific for the diagnosis of systemic vasculitis, the combination system of immunoassays for anti-MPO and IIF for pANCA is highly specific and both tests should be used together given the high diagnostic precision required for these conditions. Because patients with ANCA associated vasculitis have either anti-MPO with pANCA or anti-PR3 with cANCA, and rarely both, a combined ANCA testing system including anti-PR3/cANCA and anti-MPO/pANCA is recommended to optimize the diagnostic performance of ANCA testing. (J Rheumatol 2001;28:1584-90)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To support student learning in a large Metabolism and Nutrition class, we have introduced a web-based package, using a commercially available program, WebCT. The package was developed at a minimal cost and with limited resources. In addition to downloadable (PDF) versions of lecture Powerpoint presentations, tutorial outlines and a practical class exercise, web-based self-directed learning exercises were included to reinforce and extend lecture material in an active learning environment. The web-site also contained a variety of formative and summative assessment tasks that examined both factual recall and higher order thinking Detailed course information, timetables and a bulletin board were also readily accessible. Student usage of the site was generally high, but varied widely between individual students. Students who achieved a high overall score for the course completed on average three times as many formative assessment items and achieved a higher score for all tests than students who did poorly. Student feedback about the site was very positive with the majority of students reporting that the course material and assessment items that were available were useful to their learning. Administration of the course was also facilitated. (C) 2001 IUBMB. Published by Elsevier Science Ltd. All rights reserved.