218 resultados para SUPRATENTORIAL ANEURYSMS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Subarachnoid haemorrhage (SAH) due to spinal ependymoma is very rare. We report a 37 year old man who presented with typical clinical signs of SAH. Lumbar puncture confirmed SAH but cerebral angiography was negative, and further diagnostic work-up revealed an ependymoma of the conus medullaris as the source of the haemorrhage. A comprehensive review of the literature was conducted. Only 17 patients with spontaneous SAH due to a spinal ependymoma have been reported since 1958. However, in cases of SAH and negative diagnostic findings for cerebral aneurysms or malformations, this aetiology should be considered and work-up of the spinal axis completed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Several technical advances in thoracic aortic surgery, such as the use of antegrade cerebral perfusion, avoidance of cross-clamping and the application of glue, have beneficially influenced postoperative outcome. The aim of the present study was to analyse the impact of these developments on outcome of patients undergoing surgery of the thoracic aorta. METHODS AND RESULTS: Between January 1996 and December 2005, 835 patients (37.6%) out of 2215 aortic patients underwent surgery on the thoracic ascending aorta or the aortic arch at our institution. All in-hospital data were assessed. Two hundred and forty-one patients (28.8%) suffered from acute type A dissection (AADA). Overall aortic caseload increased from 41 patients in 1996 to 141 in 2005 (+339%). The increase was more pronounced for thoracic aortic aneurysms (TAA) (+367.9%), than for acute type A aortic dissections (+276.9%). Especially in TAA, combined procedures increased and the amount of patients with impaired left ventricular function (EF <50%) raised up from 14% in 1996 to 24% in 2005. Average age remained stable. Logistic regression curve revealed a significant decrease in mortality (AADA) and in the overall incidence of neurological deficits. CONCLUSIONS: Technical advances in the field of thoracic aortic surgery lead to a decrease of mortality and morbidity, especially in the incidence of adverse neurological events, in a large collective of patients. Long-term outcome and quality of life are better, since antegrade cerebral perfusion has been introduced.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: We have shown that selective antegrade cerebral perfusion improves mid-term quality of life in patients undergoing surgical repair for acute type A aortic dissection and aortic aneurysms. The aim of the study was to assess the impact of continuous cerebral perfusion through the right subclavian artery on immediate outcome and quality of life. METHODS: Perioperative data of 567 consecutive patients who underwent surgery of the aortic arch using deep hypothermic circulatory arrest have been analyzed. Patients were divided into three groups, according to the management of cerebral protection. Three hundred eighty-seven patients (68.3%) had deep hypothermic circulatory arrest with pharmacologic protection with pentothal only, 91 (16.0%) had selective antegrade cerebral perfusion and pentothal, and 89 (15.7%) had continuous cerebral perfusion through the right subclavian artery and pentothal. All in-hospital data were assessed, and quality of life was analyzed prospectively 2.4 +/- 1.2 years after surgery with the Short Form-36 Health Survey Questionnaire. RESULTS: Major perioperative cerebrovascular injuries were observed in 1.1% of the patients with continuous cerebral perfusion through the right subclavian artery, compared with 9.8% with selective antegrade cerebral perfusion (p < 0.001) and 6.5% in the group with no antegrade cerebral perfusion (p = 0.007). Average quality of life after an arrest time between 30 and 50 minutes with continuous cerebral perfusion through the right subclavian artery was significantly better than selective antegrade cerebral perfusion (90.2 +/- 12.1 versus 74.4 +/- 40.7; p = 0.015). CONCLUSIONS: Continuous cerebral perfusion through the right subclavian artery improves considerably perioperative brain protection during deep hypothermic circulatory arrest. Irreversible perioperative neurologic complications can be significantly reduced and duration of deep hypothermic circulatory arrest can be extended up to 50 minutes without impairment in quality of life.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Aim of this study was to analyse the relationship between popliteal artery aneurysm (PAA) and generalized arteriomegaly. PATIENTS AND METHODS: In this consecutive serie, thirty-three patients (1 woman, mean age 69.7 +/- 9.6 years) undergoing PAA repair between 1996 and 2000 agreed to participate in a duplex screening program to assess the diameters of the infrarenal abdominal aorta, common and external iliac, common and superficial femoral and contralateral popliteal arteries as well as common carotid and brachial arteries. RESULTS: The prevalence of arteriomegaly and aneurysmal disease, respectively, was as follows: abdominal aorta 15/33 (45.5%) and 8/33 (24.2%), common iliac artery 34/66 (51.5%) and 23/66 (34.8%), common femoral artery 55/66 (83.3%) and 7/66 (10.6%) as well as contralateral popliteal artery 7/33 (21.2%) 15/33 (45.5%). Significantly larger carotid artery diameters were found comparing PAA patients with age- and body surface adjusted healthy controls (p < 0.001). Furthermore, patients with multiple peripheral arterial aneurysms had significantly larger diameters of the brachial (p < 0.02) and external iliac (p < 0.005). CONCLUSIONS: Our findings support the hypothesis of a diathesis for a generalized arteriomegaly with a predilection for further aneurysms of the abdominal aorta, iliac arteries, femoral and contralateral popliteal arteries in patients with PAA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The objective of this study was to assess predictors of residual shunts after percutaneous patent foramen ovale (PFO) closure with Amplatzer PFO occluder (AGA Medical Corporation, Golden Valley, MN, USA). METHODS: All percutaneous PFO closures, using Amplatzer PFO occluder performed at a tertiary center between May 2002 and August 2006, were reviewed. Follow-up, including saline contrast transesophageal echocardiography, was performed in all patients 6 months after the intervention. PATIENTS: A total of 135 procedures were performed. Mean age of the patients was 51 years. The indication for PFO closure was an ischemic cerebrovascular event in 92%, paradoxical systemic embolism in 4%, and a diving accident in 4%. Recurrent events prior to PFO closure were noted in 34%. A concomitant atrial septal aneurysm was present in 61%. RESULTS: At 6 months follow-up, a residual shunt was detected in 26 patients (19%). Residual shunts were more common in patients with an atrial septal aneurysm (27 vs. 8%, P= .01) and in patients treated with a 35-mm compared with a 25-mm device (39 vs. 15%, P= .01). A concomitant atrial septal aneurysm remained independently associated with residual shunts when controlled for body mass index, gender, age, atrial dimensions, and presence of a Chiari network (odds ratio 4.1, 95% confidence intervals 1.1-15.0). CONCLUSION: The presence of atrial septal aneurysms in patients undergoing percutaneous PFO closure with an Amplatzer PFO occluder significantly increases the rate of residual shunts at 6 months follow-up, even if 35-mm devices are used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to establish and validate a three-dimensional imaging protocol for the assessment of Computed Tomography (CT) scans of abdominal aortic aneurysms in UK EVAR trials patients. Quality control and repeatability of anatomical measurements is important for the validity of any core laboratory. METHODS: Three different observers performed anatomical measurements on 50 preoperative CT scans of aortic aneurysms using the Vitrea 2 three-dimensional post-imaging software in a core laboratory setting. We assessed the accuracy of intra and inter observer repeatability of measurements, the time required for collection of measurements, 3 different levels of automation and 3 different automated criteria for measurement of neck length. RESULTS: None of the automated neck length measurements demonstrated sufficient accuracy and it was necessary to perform checking of the important automated landmarks. Good intra and limited inter observer agreement were achieved with three-dimensional assessment. Complete assessment of the aneurysm and iliacs took an average (SD) of 17.2 (4.1) minutes. CONCLUSIONS: Aortic aneurysm anatomy can be assessed reliably and quickly using three-dimensional assessment but for scans of limited quality, manual checking of important landmarks remains necessary. Using a set protocol, agreement between observers is satisfactory but not as good as within observers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The standard technique of two-dimensional intra-arterial digital subtraction angiography (2D-DSA) for the imaging of experimental rabbit aneurysms is invasive and has considerable surgical risks. Therefore, minimally invasive techniques ideally providing three-dimensional imaging for intervention planning and follow-up are needed. This study evaluates the feasibility and quality of three-dimensional 3-T magnetic resonance angiography (3D-3T-MRA) and compares 3D-3T-MRA with 2D-DSA in experimental aneurysms in the rabbit. METHOD: Three microsurgically created aneurysms in three rabbits were evaluated using 2D-DSA and 3D-3T-MRA. Imaging of the aneurysms was performed 2 weeks after creation using 2D-DSA and contrast-enhanced (CE) MRA. Measurements included aneurysm dome (length and width) and aneurysm neck. Aneurysm volumes were determined using CE-MRA. RESULTS: The measurements of the aneurysms' dimensions and the evaluation of vicinity vessels with both techniques showed a good correlation. The mean aneurysm length, aneurysm width and neck width measured with DSA (6.9, 4.1 and 2.8 mm, respectively) correlated with the measurements performed in 3D-3T-MRA (6.9, 4 and 2.5 mm, respectively). The mean aneurysm volumes measured with CE-MRA was 46.7 mm(3). CONCLUSION: 3D-3T CE-MRA is feasible and less invasive and is a safer imaging alternative to DSA for experimental aneurysm. Additionally, aneurysm technique this precise offers the possibility of repetitive 3D aneurysm volumetry for long-term follow-up studies after endovascular aneurysm occlusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abdominal aortic aneurysms (AAA) confer a substantial healthcare burden in the Western world. Surgical or endovascular therapy is indicated in patients with a maximum diameter exceeding 5.5 cm. Patients with smaller AAA must undergo a specific ultrasound surveillance program aimed at avoiding exposure to an increased risk of rupture once their AAA exceeds the threshold for active treatment. Based on improved understanding of the pathophysiology of AAA, recent years provided initial insight into potential medical treatment options. The presence of AAA is currently regarded a coronary artery disease risk equivalent. ACE inhibitors, statins and JNK-inhibitors were shown to have the potential to slow down progression. Since cigarette smoking is the main risk factor for both the development and progression of AAA, smoking cessation remains a key goal. Further prospective studies will assess the clinical efficacy of various promising drug treatment approaches aimed at slowing disease progression of small AAA and after endovascular therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Long term quality of life data of adult patients harboring intracranial ependymomas have not been reported. The role of adjuvant radiation therapy in Grade II ependymomas is unclear and differs from study to study. We therefore sought to retrospectively analyze outcome and quality of life of adult patients that were operated on intracranial ependymomas at four different surgical centers in two countries. All patients were attempted to be contacted via telephone to assess quality of life (QoL) at the time of the telephone interview. The standard EORTC QoL Questionnaire C30 (EORTC QLQ-C30) and the EORTC QLQ-Brain Cancer Module (QLQ-BN20) were used. 64 adult patients with intracranial ependymomas were included in the study. The only factor that was associated with increased survival was age <55 years (p < 0.001). Supratentorial location was correlated with shorter progression free survival than infratentorial location (PFS; p = 0.048). In WHO Grade II tumors local irradiation did not lead to increased PFS (p = 0.888) or overall survival (p = 0.801). Even for incompletely resected Grade II tumors local irradiation did not lead to a benefit in PFS (p = 0.911). In a multivariate analysis of QoL, irradiated patients had significantly worse scores in the item "fatigue" (p = 0.037) than non-irradiated patients. Here we present QoL data of adult patients with intracranial ependymomas. Our data show that local radiation therapy may have long-term effects on patients' QoL. Since in the incompletely resected Grade II tumors local irradiation did not lead to a benefit in PFS in this retrospective study, prospective randomized studies are necessary. In addition to age, supratentorial tumor location is associated with a worse prognosis in adult ependymoma patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION Vasospastic brain infarction is a devastating complication of aneurysmal subarachnoid hemorrhage (SAH). Using a probe for invasive monitoring of brain tissue oxygenation or blood flow is highly focal and may miss the site of cerebral vasospasm (CVS). Probe placement is based on the assumption that the spasm will occur either at the dependent vessel territory of the parent artery of the ruptured aneurysm or at the artery exposed to the focal thick blood clot. We investigated the likelihood of a focal monitoring sensor being placed in vasospasm or infarction territory on a hypothetical basis. METHODS From our database we retrospectively selected consecutive SAH patients with angiographically proven (day 7-14) severe CVS (narrowing of vessel lumen >50%). Depending on the aneurysm location we applied a standard protocol of probe placement to detect the most probable site of severe CVS or infarction. We analyzed whether the placement was congruent with existing CVS/infarction. RESULTS We analyzed 100 patients after SAH caused by aneurysms located in the following locations: MCA (n = 14), ICA (n = 30), A1CA (n = 4), AcoA or A2CA (n = 33), and VBA (n = 19). Sensor location corresponded with CVS territory in 93% of MCA, 87% of ICA, 76% of AcoA or A2CA, but only 50% of A1CA and 42% of VBA aneurysms. The focal probe was located inside the infarction territory in 95% of ICA, 89% of MCA, 78% of ACoA or A2CA, 50% of A1CA and 23% of VBA aneurysms. CONCLUSION The probability that a single focal probe will be situated in the territory of severe CVS and infarction varies. It seems to be reasonably accurate for MCA and ICA aneurysms, but not for ACA or VBA aneurysms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To analyse our results of using a double arterial perfusion strategy to avoid lower body hypothermic circulatory arrest after extensive thoracic aortic surgery. METHODS We analysed the intra- and perioperative courses of 10 patients (median age 58 years, median logistic EuroSCORE 14.6) who underwent extensive thoracic aortic surgery with a double arterial perfusion strategy. The main goal of double arterial perfusion is to separate myocardial and supra-aortic from systemic perfusion. Aortic repair starts at the most distal level of the descending aorta, followed by reinsertion of the supra-aortic vessels, and ends with completion of the proximal anastomosis or by any kind of root repair as needed. RESULTS Seven of 10 patients had prior surgery of the thoracic aorta. Indications for surgery were post-dissection aneurysm in 4 patients, true aneurysm in 3, anastomotic aneurysms in 2 and Type B aortic dissection with pseudo-coarctation in 1. Surgical access was performed through median sternotomy with left hemi-clamshell extension in all cases. There was no in-hospital mortality, but perioperative neurological symptoms occurred in 2 patients. These 2 patients developed delayed stroke (after awaking) after an initial uneventful clinical course, and in 1 of them, neurological symptoms resolved completely during follow-up. The median follow-up was 7 (±13) months. There was no death and no need for additional redo surgery during this observational period. CONCLUSIONS Extensive surgery of the thoracic aorta using a double arterial perfusion technique in order to avoid lower body hypothermic circulatory arrest is an attractive option. Further refinements of this technique may enable the safe and effective simultaneous multisegmental treatment of thoracic aortic pathology in patients who would otherwise have to undergo a two-step surgical approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES The purpose of this study was to assess the occurrence, predictors, and mechanisms of optical coherence tomography (OCT)-detected coronary evaginations following drug-eluting stent (DES) implantation. BACKGROUND Angiographic ectasias and aneurysms in stented segments have been associated with a risk of late stent thrombosis. Using OCT, some stented segments show coronary evaginations reminiscent of ectasias. METHODS Evaginations were defined as outward bulges in the luminal contour between struts. They were considered major evaginations (MEs) when extending ≥3 mm along the vessel length, with a depth ≥10% of the stent diameter. A total of 228 patients who had sirolimus (SES)-, paclitaxel-, biolimus-, everolimus (EES)-, or zotarolimus (ZES)-eluting stents implanted in 254 lesions, were analysed after 1, 2, or 5 years; and serial assessment using OCT and intravascular ultrasound (IVUS) was performed post-intervention and after 1 year in 42 patients. RESULTS Major evaginations occurred frequently at all time points in SES (∼26%) and were rarely seen in EES (3%) and ZES (2%, P = 0.003). Sirolimus-eluting stent implantation was the strongest independent predictor of ME [adjusted OR (95% CI) 9.1 (1.1-77.4), P = 0.008]. Malapposed and uncovered struts were more common in lesions with vs. without ME (77 vs. 25%, P < 0.001 and 95 vs. 20%, P < 0.001, respectively) as was thrombus [49 vs. 14%, OR 7.3 (95% CI: 1.7-31.2), P = 0.007]. Post-intervention intra-stent dissection and protrusion of the vessel wall into the lumen were associated with an increased risk of evagination at follow-up [OR (95% CI): 2.9 (1.8-4.9), P < 0.001 and 3.3 (1.6-6.9), P = 0.001, respectively]. In paired IVUS analyses, lesions with ME showed a larger increase in the external elastic membrane area (20% area change) compared with lesions without ME (5% area change, P < 0.001). CONCLUSION Optical coherence tomography-detected MEs are a specific morphological footprint of early-generation SES and are nearly absent in newer-generation ZES and EES. Evaginations appear to be related to vessel injury at baseline; are associated with positive vessel remodelling; and correlate with uncoverage, malapposition, and thrombus at follow-up.