958 resultados para SPINAL ACCESSORY NERVE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Previous studies have associated neurohumoral excitation, as estimated by plasma norepinephrine levels, with increased mortality in heart failure. However, the prognostic value of neurovascular interplay in heart failure (HF) is unknown. We tested the hypothesis that the muscle sympathetic nerve activity (MSNA) and forearm blood flow would predict mortality in chronic heart failure patients. Methods: One hundred and twenty two heart failure patients, NYHA II-IV, age 50 +/- 1 ys, LVEF 33 +/- 1%, and LVDD 7.1 +/- 0.2 mm, were followed up for one year. MSNA was directly measured from the peroneal nerve by microneurography. Forearm blood flow was obtained by venous occlusion plethysmography. The variables were analyzed by using univariate, stepwise multivariate Cox proportional hazards analysis, and Kaplan-Meier analysis. Results: After one year, 34 pts died from cardiac death. The univariate analysis showed that MSNA, forearm blood flow, LVDD, LVEF, and heart rate were significant predictors of mortality. The multivariate analysis showed that only MSNA (P = 0.001) and forearm blood flow (P = 0.003) were significant independent predictors of mortality. On the basis of median levels of MSNA, survival rate was significantly lower in pts with >49 bursts/min. Similarly, survival rate was significantly lower in pts with forearm blood flow <1.87 ml/min/100 ml (P = 0.002). Conclusion: MSNA and forearm blood flow predict mortality rate in patients with heart failure. It remains unknown whether therapies that specifically target these abnormalities will improve survival in heart failure. (C) 2008 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The world's deep oceans are home to a number of teleosts with asymmetrical or tubular eyes. These immobile eyes possess large spherical lenses and subtend a large binocular visual field directed either dorsally or rostrally. Derived from a lateral non-tubular eye, the tubular eye is comprised of a thick main retina, subserving the rostrally or dorsally directed binocular visual field, and a thin accessory retina subserving, the lateral, monocular visual field. The main retina is thought to receive a focussed image, while the accessory retina is too close to the lens for a focussed image to be received. Several species also possess retinal diverticula, which are small evaginations of differentiated retina located in the rostrolateral wall of the eye and thought to increase the visual field. In order to investigate the spatial resolving power of these retinae (main, accessory and diverticulum), the distribution of cells within the ganglion cell layer was analysed from retinal wholemounts and sectioned material in ten species representing four genera. In all species, the main retina possesses a marked increase in cell density towards a specialised retinal region (area centralis), with a centro-peripheral gradient range between 7.1 and 60:1 and a peak density range of between 30 and 55 x 10(3) cells per mm(2). The accessory retinae and the transitional zone between the main and accessory retinae possess relatively low cell densities (between 1 and 10 x 10(3) cells per mm(2)) and lack an area centralis. Retinal diverticula examined in four species possess mean ganglion cell densities of between 7.2 and 109.4 x 10(3) cells per mm(2). Analyses of soma areas show that the ganglion cell layer of most species possesses cells with areas in a range of 8.0 to 15.4 mu m(2) in the main retina and between 15.1 and 17.4 mu m(2) in the accessory retina. The peak spatial resolving power of the main retina of the ten species varies from 4.1 to 9.1 cycles per degree. The positions of the retinal areae centrales relative to each species' binocular visual field are discussed in relation to what is known of feeding behaviour of these fishes in the deep-sea.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is known that physical activity triggers changes in the central nervous system Adult rats, trained on treadmills for 4 weeks, and a group of sedentary rats was submitted to contuse moderate spinal cord injury A group of sedentary rats was submitted to a sham operation The trained group continued running on treadmill after lesion for 4 weeks Motor behavior evaluated by BBB score was smaller in the sedentary group compared to the trained rats by 7 days after lesion Computerized activity monitor showed clear-cut differences in spontaneous motor parameters in trained rats only before lesion After surgery, sedentary rats showed changes in motor parameters but not in later periods of analysis Animals were euthanized by 28 days after surgery, and their spinal cords were processed for Nissl staining and immunohistochemistry The number of the remaining neurons and the lesion areal and lesion volume fractions were obtained by stereological method The number of the remaining neurons did not change after training Lesion volume and lesion areal fraction per section were smaller in the trained group Lesion index was more pronounced in the sedentary group Microdensitometric image analysis demonstrated a microglial reaction, astroglial activation, and glial FGF-2 production more pronounced in the spinal cord of sedentary animals GAP-43 was higher in caudal levels of contusion in the sedentary group In conclusion, treadmill running may favor a better functional recovery in the acute period after spinal cord lesion and wound repair processes leading to neuroprotection (C) 2010 Elsevier B V All rights reserved

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neuron-glia interaction is involved in physiological function of neurons, however, recent evidences have suggested glial cells as participants in neurotoxic and neurotrophic mechanisms of neurodegenerative/neuroregenerative processes. Laser microdissection offers a unique opportunity to study molecular regulation in specific immunolabeled cell types. However, an adequate protocol to allow morphological and molecular analysis of rodent spinal cord astrocyte, microglia and motoneurons remains a big challenge. In this paper we present a quick method to immunolabel those cells in flash frozen sections to be used in molecular biology analyses after laser microdissection and pressure catapulting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amyotrophic lateral sclerosis (ALS) is a progressive degenerative disorder affecting motoneurons and the SOD1(G93A) transgenic mice are widely employed to study disease physiopathology and therapeutic strategies. Despite the cellular and biochemical evidences of an early motor system dysfunction, the conventional behavioral tests do not detect early motor impairments in SOD1 mouse model. We evaluated early changes in motor behavior of ALS mice by doing the analyses of tail elevation, footprint, automatic recording of motor activities by means of an infrared motion sensor activity system and electrophysiological measurements in male and female wild-type (WT) and SOD1(G93A) mice from postnatal day (P) 20 up to endpoint. The classical evaluations of mortality, weight loss, tremor, rotometer, hanging wire and inclined plane were also employed. There was a late onset (after P90) of the impairments of classical parameters and the outcome varied between genders of ALS mice, being tremor, cumulative survival, weight loss and neurological score about 10 days earlier in male than female ALS mice and also about 20 days earlier in ALS males regarding rotarod and hanging wire performances. While diminution of hindpaw base was 10 days earlier in ALS males (P110) compared to females, the steep length decreased 40 days earlier in ALS females (P60) than ALS males. The automatic analysis of motor impairments showed substantial late changes (after P90) of motility and locomotion in the ALS females, but not in the ALS males. It was surprising that the scores of tail elevation were already decreased in ALS males and females by P40, reaching the minimal values at the endpoint. The electrophysiological analyses showed early changes of measures in the ALS mouse sciatic nerve, i.e., decreased values of amplitude (P40) and nerve conduction velocity (P20), and also an increased latency (P20) reaching maximal level of impairments at the late disease phase. The early changes were not accompanied by reductions of neuronal protein markers of neurofilament 200 and ChAT in the ventral part of the lumbar spinal cord of P20 and P60 ALS mice by means of Western blot technique, despite remarkable decreases of those protein levels in P120 ALS mice. In conclusion, early changes of motor behavior and electrophysiological parameters in ALS mouse model must be taken into attention in the analyses of disease mechanisms and therapeutic effects. (C) 2011 Published by Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To establish the occurrence of Periodic Leg Movements (PLM) and Restless Legs Syndrome (RLS) in Spinal Cord Injury (SCI) subjects. Methods: In this study, twenty four patients were submitted to a full night polysomnography and were assessed with Epworth Sleepiness Scale and an adapted form of International Restless Legs Syndrome Scale Rating Scale (IRLS Rating Scale). Control Group (CG) was composed of 16 subjects, 50% of each sex, age: 24.38 +/- 4 years old. Spinal Cord Injury Group (SCIG) was composed of 8 subjects (29 +/- 5 years old) with a complete SCI (ASIA A) of about three and a half years of duration, 100% males. Results: 100% of SCIG had RLS compared to 17% in CG ( p < 0.0001). SCIG had 18.11 +/- 20.07 of PLM index while CG had 5.96 +/- 11.93 (p = 0.01). Arousals related to PLM were recorded in CG and SCIG. There was a positive moderate correlation between RLS and age (r = 0.5; p = 0.01), RLS and PLM (r = 0.49; p = 0.01), adapted IRLS Rating Scale and PLM index (r = 0.64; p = 0.03) and also a negative moderate correlation between Epworth Sleepiness Scale and PLM index (r = -0.4; p = 0.04) in both groups. Conclusion: RLS and PLM are common findings in SCI patients with a complete injury. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Restoration of nerve continuity and effective maintenance of coaptation are considered fundamental principles of end-to-end peripheral nerve repair. OBJECTIVE: To evaluate the influence of the number of stitches on axonal regeneration and collagen production after neurorrhaphy. METHODS: Thirty male Wistar rats were equally divided into 3 groups and were all operated on with the right sciatic nerve exposed. In 2 groups, the nerve was sectioned and repaired by means of 3 (group B) or 6 (group C) epineurium sutures with 100 monofilament nylon. One group (group A) was used as a control. Each animal from groups B and C underwent electrophysiological evaluation with motor action potential recordings before nerve section and again at an 8-week interval after neurorrhaphy. Nerve biopsy specimens were used for histomorphometric assessment of axonal regeneration and quantification of collagen at the repair site. RESULTS: Animals from group C had significantly lower motor action potential conduction velocities compared with control animals (P = .02), and no significant difference was seen between groups B and C. Parameters obtained from morphometric evaluation were not significantly different between these 2 groups. Type I collagen and III collagen in the epineurium were significantly higher in group C than in either the control group (P = .001 and P = .003) or group B (P = .01 and P = .02). No differences were identified for collagen I and III in the endoneurium. CONCLUSION: Using 6 sutures for nerve repair is associated with worse electrophysiological outcomes and higher amounts of type I and III collagen in the epineurium compared with control. Neurorraphy with 6 stitches is also related to a significant increase in epineurium collagen I and III compared with 3-stitch neurorraphy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three patients with progressive visual loss, chronic alcoholism and tabagism were submitted to a complete neuro-ophthalmic examination and to retinal nerve fiber layer (RNFL) measurements using optical coherence tomography (OCT) scanning. Two patients showed marked RNFL loss in the temporal sector of the optic disc. However, a third patient presented RNFL measurements within or above normal limits, based on the Stratus-OCT normative database. Such findings may be due to possible RNFL edema similar to the one that may occur in the acute phase of toxic optic neuropathies. Stratus-OCT was able to detect RNFL loss in the papillomacular bundle of patients with tobacco-alcohol-induced toxic optic neuropathy. However, interpretation must be careful when OCT does not show abnormality in order to prevent diagnostic confusion, since overestimation of RNFL thickness measurements is possible in such cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare the ability of Subjective assessment of optic nerve head (ONH) and retinal nerve fiber layer (RNFL) by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec Inc), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg. Germany), and scanning laser polarimetry (GDx enhanced corneal compensation; Carl Zeiss Meditec Inc, Dublin, CA) in discriminating glaucomatous and normal eyes. Methods: Sixty-one glaucomatous and 57 normal eyes or 118 subjects Were included in the study. Three independent general ophthalmologists and I glaucoma expert evaluated ONH stereo-photographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons or areas under these curves (aROCs) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Results: Best parameter from each technique showed larger aROC (Stratus OCT RNFL 0.92; Stratus OCT ONH vertical integrated area = 0.86; Stratus OCT macular thickness = 0.82; GDx enhanced corneal compensation = 0.91, HRT3 global cup-to-disc ratio = 0.83; HRT3 glaucoma probability score numeric area score 0.83) compared with stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared with stereophoto grading by general ophthalmologists, The combination Of Subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with Subjective assessment of the optic disc by a glaucoma expert (29.5% vs. 19.7%, respectively). Conclusions: Diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by It glaucoma expert, Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare the ability of Fourier-domain (FD) optical coherence tomography (3D OCT-1000; Top, con, Tokyo, Japan) and time domain (TD) OCT (Stratus; Carl Zeiss Meditec Inc, Dublin, California, USA) to detect axonal loss in eyes with band atrophy (BA) of the optic nerve. DESIGN: Cross-sectional study. METHODS: Thirty-six eyes from 36 patients with BA and temporal visual field (VF) defect from chiasmal compression and 36 normal eyes were studied. Subjects were submitted to standard automated perimetry and macular and retinal nerve fiber layer (RNFL) measurements were taken using 3D OCT-1000 and Stratus OCT. Receiver operating characteristic (ROC) curves were calculated for each parameter. Spearman correlation coefficients were obtained to evaluate the relationship between RNFL and macular thickness parameters and severity of VF loss. Measurements from the two devices were compared. RESULTS: Regardless of OCT device, all RNFL and macular thickness parameters were significantly lower in eyes with BA compared with normal eyes, but no statistically significant difference was found with regard to the area under the ROC curve. Structure-function relationships were also similar for the two devices. In both groups, RNFL and macular thickness measurements were generally and in some cases significantly smaller with 3D OCT-1000 than with Stratus OCT. CONCLUSIONS: The introduction of FD technology did not lead to better discrimination ability for detecting BA of the optic nerve compared with TD technology when using the software currently provided by the manufacturer. 3D OCT-1000 FD OCT RNFL and macular measurements were generally smaller than TD Stratus OCT measurements. Investigators should be aware of this fact when comparing measurements obtained with these two devices. (Am J Oplathalmol 2009;147: 56-63. (c) 2009 by Elsevier Inc. All rights reserved.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: In cases of partial lesions of the intratemporal segment of the facial nerve, should the surgeon perform an intraoperative partial reconstruction, or partially remove the injured segment and place a graft? We present results from partial lesion reconstruction on the intratemporal segment of the facial nerve. Methods: A retrospective study on 42 patients who presented partial lesions on the intratemporal segment of the facial nerve was performed between 1988 and 2005. The patients were divided into 3 groups based on the procedure used: interposition of the partial graft on the injured area of the nerve (group 1; 12 patients); keeping the preserved part and performing tubulization (group 2; 8 patients); and dividing the parts of the injured nerve (proximal and distal) and placing a total graft of the sural nerve (group 3; 22 patients). Results: Fracture of the temporal bone was the most frequent cause of the lesion in all groups, followed by iatrogenic causes (p < 0.005). Those who obtained results lower than or equal to III on the House-Brackmann scale were 1 (8.3%) of the patients in group 1, none (0.0%) of the patients in group 2, and 15 (68.2%) of the patients in group 3 (p < 0.001). Conclusions: The best surgical technique for therapy of a partial lesion of the facial nerve is still questionable. Among these 42 patients, the best results were those from the total graft of the facial nerve.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim To compare the ability of scanning laser polarimeter (SLP) with variable corneal compensation (GDx VCC) and optical coherence tomograph (Stratus OCT) to discriminate between eyes with band atrophy (BA) of the optic nerve and healthy eyes. Methods The study included 37 eyes with BA and temporal visual field (VF) defects from chiasmal compression, and 29 normal eyes. Subjects underwent standard automated perimetry (SAP) and retinal nerve fibre layer (RNFL) scans using GDx VCC and Stratus OCT. The severity of the VF defects was evaluated by the temporal mean defect (TMD), calculated as the average of 22 values of the temporal total deviation plot on SAP. Receiver operating characteristic (ROC) curves were calculated. Pearson`s correlation coefficients were used to evaluate the relationship between RNFL thickness parameters and the TMD. Results No significant difference was found between the ROC curves areas (AUCs) for the GDx VCC and Stratus OCT with regard to average RNFL thickness (0.98 and 0.99, respectively) and the superior (0.94; 0.95), inferior (0.96; 0.97), and nasal (0.92; 0.96) quadrants. However, the AUC in the temporal quadrant (0.77) was significantly smaller (P < 0.001) with GDx VCC than with Stratus OCT (0.98). Lower TMD values were associated with smaller RNFL thickness in most parameters from both equipments. Conclusion Adding VCC resulted in improved performance in SLP when evaluating eyes with BA, and both technologies are sensitive in detecting average, superior, inferior, and nasal quadrant RNFL loss. However, GDx VCC still poorly discriminates RNFL loss in the temporal quadrant when compared with Stratus OCT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To describe the anatomy of the sphenopalatine foramen (SPF) region and possible anatomical variations. Study Design: Prospective study accomplished from September, 2006, to January, 2007. Methods: The sphenopalatine foramen (SPF) of 61 cadavers were carefully dissected. Presence of the ethmoidal crest, location of sphenopalatine and accessory foramens, and the number of arterial branches emerging through foramens were observed. Data were analyzed in relation to gender, racial group, and symmetry of the cadaver. Prediction of the presence of accessory foramen was evaluated. Results: Mixed race cadavers prevailed in 122 nasal fossae dissected (75% males). Ethmoidal crest was present in 100% of the cadavers, being anterior to the SPF in 98.4% of the cases. The most frequent SPF location was the transition of the middle and superior meatus (86.9%). Mean distance from the SPF and accessory foramen to anterior nasal spine was 6.6 cm and 6.7 cm, respectively. Accessory foramen was present in 9.83% of the cases. A single arterial stem emerged through the SPF in 67.2% of the cases, and 100% through accessory foramens. The prevalence analyses showed no differences that were statistically significant (P > 0.05) between gender and racial group. The symmetry analyses showed a strong conformity (P < 0.01) between nasal fossae in relation to the SPF location. There was no statistically significant conformity between nasal fossae and accessory foramen (P = 0.53). None of the variables of interest presents any statistically significant (P > 0.05) association with the presence of the accessory foramen. Conclusions: There are anatomical variations in the lateral nose wall that should be considered for successful endoscopic surgical treatment of severe epistaxis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To study increases in electromyographic (EMG) response from the right and left rectus femoris muscles of individuals with long-term cervical spinal cord injuries after EMG biofeedback treatment. Design Repeated measure trials compared EMG responses before and after biofeedback treatment in patients with spinal cord injuries. Main outcome measures The Neuroeducator was used to analyse and provide feedback of the EMG signal and to measure EMG response. Setting Department of Traumatic Orthopaedics, School of Medicine, University of Sao Paulo, Brazil. Participants Twenty subjects (three men and 17 women), between 21 and 49 years of age, with incomplete spinal cord injury at level C6 or higher (range C2 to C6). Of these subjects, 10 received their spinal cord injuries from motor vehicle accidents, one from a gunshot, five from diving, three from falls and one from spinal disc herniation. Results Significant differences were found in the EMG response of the right rectus femoris muscle between pre-initial (T1), post-initial (T2) and additional (T3) biofeedback treatment with the subjects in a sitting position [mean (standard deviation) T1: 26 mu V (29); T2: 67 mu V (50); T3: 77 mu V (62)]. The mean differences and 95% confidence intervals for these comparisons were as follows: T1 to T2, -40.7 (-53.1 to -29.4); T2 to T3, -9.6 (-26.1 to 2.3). Similar differences were found for the left leg in a sitting position and for both legs in the sit-to-stand condition. Conclusions The EMG responses obtained in this study showed that treatment involving EMG biofeedback significantly increased voluntary EMG responses from right and left rectus femoris muscles in individuals with spinal cord injuries. (C) 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To standardize an experimental model of spinal cord injury in Wistar rats, computerized weight fall impact equipment were used and the parameters were used determined by the multicenter animal spinal cord injury study - MASCIS. Methods: Thirty rats were used, with age varying between 20 and 25 weeks, and weight ranging from 200 to 300g for females, and from 232 to 430g for males. The impacts were done with weights of 10g starting from 12.5, 25 and 50 mm of height, and the impact speed and compression coefficient were obtained. The impact occurred on the surface of the spinal cord at the level of the tenth thoracic vertebra after laminectomy. Vital signs were monitored and gas analysis was made before and after the spinal cord injury. The lesion volume was evaluated by the quantitative analysis of sodium and potassium ions. Results: Statistically significant correlations were verified among the lesion volume and the mechanical parameters. The lesion volume caused by the fall from 50mm height was superior to that of the 12.5 and 25mm, which didn`t differ from each other. Conclusion: The model demonstrated itself to be effective and capable of generating standard spinal cord injuries on Wistar rats.