913 resultados para Photoelastic stress analysis
Resumo:
"Subject no. 18550. Stress analysis."
Resumo:
The morphology and distribution of high-pressure metastable phases BC8 and R8, formed in monocrystalline silicon under microindentation, were identified and assessed using transmission electron microscopy nanodiffraction analysis. It was discovered that the crystal growth inside the transformation zone was stress-dependent with large crystals in its central region. The crystal size could also be increased using higher maximum indentation loads. The BC8 and R8 phases distributed unevenly across the transformation zone, with BC8 crystals mainly in the center of the zone and smaller R8 fragments in the peripheral regions. Such phase distribution was in agreement with the theoretical residual stress analysis.
Resumo:
Este estudo avaliou a colagem de braquetes linguais nas faces linguais de pré-molares superiores com diferentes espessuras de PADs, confeccionados com a resina fotopolimerizável Transbond XT nas espessuras de 1,0 mm e 2,0 mm e comparando-os com a menor espessura possível. Foi utilizado o adesivo Sondhi Rapid Set para a colagem indireta. Avaliou-se a força de resistência sob cisalhamento cinco minutos após a colagem em uma máquina de ensaios mecânicos Kratos, com velocidade de cruzeta de 1,0 mm/min. A força média da resistência da colagem sob cisalhamento para o Grupo I foi de 9,69 MPa (DP 4,02 MPa), para o Grupo II foi de 6,15 MPa (DP 2,69 MPa) e para o Grupo III foi de 5,73 MPa (DP 1,62 MPa). O Grupo I, com menor espessura do PAD, apresentou força de resistência da colagem sob cisalhamento significativamente maior do que os Grupos II e III (PADs com 1,0 e 2,0 mm respectivamente). Estes por sua vez, não apresentaram diferença estatisticamente significante ao nível de p<0,05. O índice 1 de Adesivo Remanescente predominou nos Grupos I e II, caracterizando um maior número de fraturas do tipo adesiva. No Grupo 3 predominou o Índice 2, com fraturas do tipo coesiva.(AU)
Resumo:
Inflammatory bowel diseases is composed by a set of chronic and inflammatory disorders, among them is ulcerative colitis (UC). UC treatment is based on anti-inflammatory administration; however, this group of drugs clearly leads to development of undesirable side effects, what stimulate the search for new therapies alternatives. The aim of this study was to evaluate the effect of hydroalcholic Turnera subulata extract on acetic acid-induced acute UC in rats. UC was induced by 1 mL injection of 4% acetic acid via rectal in Wistar mouse. 42 animals were distributed among 6 experimental groups: Control, UC, Sulfasalazine 500 mg/Kg/day (SSZ), T. subulata 50mg/Kg/day (TS 50), T. subulata 100mg/Kg/day (TS 100), T. subulata 200mg/Kg/day (TS 200). Throughout the experiment, body weight, food and water ingestion was daily evaluated. At the end of the experiment, the animals were euthanized and a colon fragment was observed by macroscopic analysis. Colon fragments were also collected for microscopic analysis and oxidative stress evaluation. The means from each group was compared by ANOVA test with a significance level of 5% (p<0.05) using GraphPad Prism Software. As results, we can clearly observe that SSZ group had the greater body weight decrease among the groups throughout the experiments, 14.78%, as well as, the lowest food intake, 6.23 g of food/day. The animals treated with T. subulata extracts showed no important body weight loss when compared to control. UC group showed the highest tissue damage macroscope score, 6.5, while TS 50 showed the lowest tissue damage score: 1. Microscope evaluation showed the presence of edema, haemorraghia and ulceration in all group of animals, except for Control. Nevertheless, TS 50 showed the lowest inflammatory damage among all groups. Oxidative stress analysis revealed that T. subulata treatment modulate catalase and superoxide dismutase activity, we also observed a decrease in protein and lipid peroxidation in response to extract administration. Taken together, these results shows that T. subulata extract exerts anti-inflammatory and anti-oxidant effects on experimental UC.
Resumo:
Inflammatory bowel diseases is composed by a set of chronic and inflammatory disorders, among them is ulcerative colitis (UC). UC treatment is based on anti-inflammatory administration; however, this group of drugs clearly leads to development of undesirable side effects, what stimulate the search for new therapies alternatives. The aim of this study was to evaluate the effect of hydroalcholic Turnera subulata extract on acetic acid-induced acute UC in rats. UC was induced by 1 mL injection of 4% acetic acid via rectal in Wistar mouse. 42 animals were distributed among 6 experimental groups: Control, UC, Sulfasalazine 500 mg/Kg/day (SSZ), T. subulata 50mg/Kg/day (TS 50), T. subulata 100mg/Kg/day (TS 100), T. subulata 200mg/Kg/day (TS 200). Throughout the experiment, body weight, food and water ingestion was daily evaluated. At the end of the experiment, the animals were euthanized and a colon fragment was observed by macroscopic analysis. Colon fragments were also collected for microscopic analysis and oxidative stress evaluation. The means from each group was compared by ANOVA test with a significance level of 5% (p<0.05) using GraphPad Prism Software. As results, we can clearly observe that SSZ group had the greater body weight decrease among the groups throughout the experiments, 14.78%, as well as, the lowest food intake, 6.23 g of food/day. The animals treated with T. subulata extracts showed no important body weight loss when compared to control. UC group showed the highest tissue damage macroscope score, 6.5, while TS 50 showed the lowest tissue damage score: 1. Microscope evaluation showed the presence of edema, haemorraghia and ulceration in all group of animals, except for Control. Nevertheless, TS 50 showed the lowest inflammatory damage among all groups. Oxidative stress analysis revealed that T. subulata treatment modulate catalase and superoxide dismutase activity, we also observed a decrease in protein and lipid peroxidation in response to extract administration. Taken together, these results shows that T. subulata extract exerts anti-inflammatory and anti-oxidant effects on experimental UC.
Resumo:
Durante el desarrollo de un niño pueden ocurrir diversas anomalías y distorsiones en el crecimiento de los huesos que resultan en distintos problemas. Independientemente de las razones por las que ocurren, si son detectadas y tratadas con tiempo sus secuelas pueden ser minimizadas o eliminadas. Este trabajo continúa el proyecto integrador de ingeniería mecánica del ingeniero Matías Korten. En ese trabajo se realizaron ensayos termomecánicos a alambres de NiTi para caracterizar las fuerzas desarrolladas y la influencia de diferentes parámetros geométricos y físicos en las mismas. El Dr. J. Groiso propone la fabricación de un dispositivo pseudoelástico y biocompatible de NiTi para corregir deformaciones angulares en huesos. En este trabajo, se buscó caracterizar nuevamente el material NiTi, validar los resultados obtenidos en ese trabajo y diseñar un dispositivo que permita la caracterización del material de forma más confiable. Se desarrolló un modelo computacional de un hueso en 3D que permite obtener el campo de tensiones sobre la placa de crecimiento al aplicar una fuerza superficial sobre los tornillos. Se analizaron los resultados con distintas formas de aplicación de la fuerza, la zona afectada por la prótesis al cambiar la posición de los tornillos y se hizo un análisis de sensibilidad en el rango (según bibliografía) del módulo de elasticidad de la placa de crecimiento. Se concluye que la aplicación de un dispositivo de NiTi puede generar las tensiones necesarias para impulsar el crecimiento del hueso en la dirección correcta.
Resumo:
Durante el desarrollo de un niño pueden ocurrir diversas anomalías y distorsiones en el crecimiento de los huesos que resultan en distintos problemas. Independientemente de las razones por las que ocurren, si son detectadas y tratadas con tiempo sus secuelas pueden ser minimizadas o eliminadas. Este trabajo continúa el proyecto integrador de ingeniería mecánica del ingeniero Matías Korten. En ese trabajo se realizaron ensayos termomecánicos a alambres de NiTi para caracterizar las fuerzas desarrolladas y la influencia de diferentes parámetros geométricos y físicos en las mismas. El Dr. J. Groiso propone la fabricación de un dispositivo pseudoelástico y biocompatible de NiTi para corregir deformaciones angulares en huesos. En este trabajo, se buscó caracterizar nuevamente el material NiTi, validar los resultados obtenidos en ese trabajo y diseñar un dispositivo que permita la caracterización del material de forma más confiable. Se desarrolló un modelo computacional de un hueso en 3D que permite obtener el campo de tensiones sobre la placa de crecimiento al aplicar una fuerza superficial sobre los tornillos. Se analizaron los resultados con distintas formas de aplicación de la fuerza, la zona afectada por la prótesis al cambiar la posición de los tornillos y se hizo un análisis de sensibilidad en el rango (según bibliografía) del módulo de elasticidad de la placa de crecimiento. Se concluye que la aplicación de un dispositivo de NiTi puede generar las tensiones necesarias para impulsar el crecimiento del hueso en la dirección correcta.
Resumo:
This dissertation focuses on design challenges caused by secondary impacts to printed wiring assemblies (PWAs) within hand-held electronics due to accidental drop or impact loading. The continuing increase of functionality, miniaturization and affordability has resulted in a decrease in the size and weight of handheld electronic products. As a result, PWAs have become thinner and the clearances between surrounding structures have decreased. The resulting increase in flexibility of the PWAs in combination with the reduced clearances requires new design rules to minimize and survive possible internal collisions impacts between PWAs and surrounding structures. Such collisions are being termed ‘secondary impact’ in this study. The effect of secondary impact on board-level drop reliability of printed wiring boards (PWBs) assembled with MEMS microphone components, is investigated using a combination of testing, response and stress analysis, and damage modeling. The response analysis is conducted using a combination of numerical finite element modeling and simplified analytic models for additional parametric sensitivity studies.
Resumo:
A utilização de adesivos hoje em dia encontra-se de tal forma disseminada que é transversal a diversos setores do mercado, como a indústria aeroespacial, aeronáutica, automóvel e do desporto. De facto, o uso de ligações adesivas em estruturas mecânicas tem vindo a crescer, na medida em que estes têm substituído os métodos de ligação convencionais, tais como brasagem, rebitagem, ligações aparafusadas e soldadura. No geral, as ligações adesivas apresentam diversas vantagens, desde a diminuição do peso, redução da concentração de tensões, facilidade de fabrico, bom comportamento a solicitações cíclicas e capacidade de unir materiais dissimilares. O crescente interesse da indústria nas ligações adesivas tem por base o aumento da confiabilidade nos métodos de previsão de resistência de estruturas adesivas. Neste contexto surgem os Modelos de Dano Coesivo, que permitem simular o crescimento do dano em estruturas, após introdução das leis coesivas previamente estimadas nos modelos numéricos. Uma das fases mais importantes neste método de previsão é a estimativa das leis coesivas em tração e corte, pelo que se torna de grande relevância a existência e validação de métodos precisos para a obtenção destas leis. Este trabalho visa a validação de leis coesivas em tração e corte, estimadas pela aplicação do método direto, na previsão da resistência de juntas com geometria de solicitação mista. Neste âmbito, ensaiaram-se JSS e JSD com diferentes comprimentos de sobreposição e com adesivos de diferente ductilidade. Foram considerados os adesivos Araldite® AV138, de elevada resistência e baixa ductilidade, o Araldite® 2015, de moderada ductilidade e resistência intermédia, e o SikaForce® 7752, de baixa resistência e elevada ductilidade. As leis coesivas em modo puro serviram de base para a criação de leis simplificadas triangulares, trapezoidais e linearesexponenciais, que foram testadas para cada um dos adesivos. A validação das mesmas consumou-se por comparação das previsões numéricas com os resultados experimentais. Procedeu-se também a uma análise de tensões de arrancamento e de corte no adesivo, de modo a compreender a influência das tensões na resistência das juntas. A utilização do método direto permitiu obter previsões de resistência bastante precisas, indicando as formas de leis coesivas mais adequadas para cada conjunto adesivo/geometria de junta. Para além disso, para as condições geométricas e materiais consideradas, este estudo permitiu concluir que não se cometem erros significativos na escolha de uma lei menos adequada.
Resumo:
FEA simulation of thermal metal cutting is central to interactive design and manufacturing. It is therefore relevant to assess the applicability of FEA open software to simulate 2D heat transfer in metal sheet laser cuts. Application of open source code (e.g. FreeFem++, FEniCS, MOOSE) makes possible additional scenarios (e.g. parallel, CUDA, etc.), with lower costs. However, a precise assessment is required on the scenarios in which open software can be a sound alternative to a commercial one. This article contributes in this regard, by presenting a comparison of the aforementioned freeware FEM software for the simulation of heat transfer in thin (i.e. 2D) sheets, subject to a gliding laser point source. We use the commercial ABAQUS software as the reference to compare such open software. A convective linear thin sheet heat transfer model, with and without material removal is used. This article does not intend a full design of computer experiments. Our partial assessment shows that the thin sheet approximation turns to be adequate in terms of the relative error for linear alumina sheets. Under mesh resolutions better than 10e−5 m , the open and reference software temperature differ in at most 1 % of the temperature prediction. Ongoing work includes adaptive re-meshing, nonlinearities, sheet stress analysis and Mach (also called ‘relativistic’) effects.
Resumo:
The behaviour of bone tissue during drilling has been subject of recent studies due to its great importance. Because of thermal nature of the bone drilling, high temperatures and thermal mechanical stresses are developed during drilling that affect the process quality. However, there is still a lack information with regard to the distribution of mechanical and thermal stresses during bone drilling. The present paper describes a sequentially coupled thermal-stress analysis to assess the mechanical and thermal stress distribution during bone drilling. A three-dimensional thermo-mechanical model was developed using the ANSYS/LSDYNA finite element code under different drilling conditions. The model incorporates the dynamic characteristics of drilling process, as well as the thermo-mechanical properties of the involved materials. Experimental tests with polyurethane foam materials were also carried out. It was concluded that the use of higher feed-rates lead to a decrease of normal stresses and strains in the foam materials. The experimental and numerical results were compared and showed good agreement. The proposed numerical model could be used to predict the better drilling parameters and minimize the bone injuries.
Resumo:
In questo elaborato vengono descritte le modalità ed i criteri di progettazione di un impianto di riutilizzo di vapore surriscaldato residuo, per un’applicazione industriale di riscaldamento di acqua desalinizzata. Il vapore, che si trova stanziato in linee di accumulo considerate preesistenti, verrà successivamente spillato e canalizzato verso uno scambiatore termico a fascio tubiero controcorrente. A valle di quest’ultimo, si sviluppa una linea di ritorno di condensa che si conclude con il collegamento della stessa ad una linea di accumulo di condensa, anch'essa considerata preesistente. L’obiettivo principale dell’elaborato è la progettazione delle linee piping necessarie per la corretta e completa realizzazione dell’impianto sopracitato, sia a livello operativo che di sicurezza. A tale scopo, quindi, viene descritto il layout generale d’impianto, vengono stabiliti gli approcci da seguire, come la supportazione delle linee stesse ed i metodi di smorzamento delle tensioni termiche accumulate, ed, una volta introdotte le normative e gli standard utilizzati in fase di progettazione, viene fatta una verifica mediante utilizzo di software di calcolo a elementi finiti (Caesar 2), i cui risultati andranno a giustificare le scelte progettuali ed a convalidare l’attuale installazione del progetto.
Resumo:
The aim of this study was to evaluate by photoelastic analysis stress distribution on short and long implants of two dental implant systems with 2-unit implant-supported fixed partial prostheses of 8 mm and 13 mm heights. Sixteen photoelastic models were divided into 4 groups: I: long implant (5 × 11 mm) (Neodent), II: long implant (5 × 11 mm) (Bicon), III: short implant (5 × 6 mm) (Neodent), and IV: short implants (5 × 6 mm) (Bicon). The models were positioned in a circular polariscope associated with a cell load and static axial (0.5 Kgf) and nonaxial load (15°, 0.5 Kgf) were applied to each group for both prosthetic crown heights. Three-way ANOVA was used to compare the factors implant length, crown height, and implant system (α = 0.05). The results showed that implant length was a statistically significant factor for both axial and nonaxial loading. The 13 mm prosthetic crown did not result in statistically significant differences in stress distribution between the implant systems and implant lengths studied, regardless of load type (P > 0.05). It can be concluded that short implants showed higher stress levels than long implants. Implant system and length was not relevant factors when prosthetic crown height were increased.