995 resultados para Neonatal hearing screening


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report a novel homozygous missense mutation in the ubiquinol-cytochrome c reductase synthesis-like (BCS1L) gene in two consanguineous Turkish families associated with deafness, Fanconi syndrome (tubulopathy), microcephaly, mental and growth retardation. All three patients presented with transitory metabolic acidosis in the neonatal period and development of persistent renal de Toni-Debré-Fanconi-type tubulopathy, with subsequent rachitis, short stature, microcephaly, sensorineural hearing impairment, mild mental retardation and liver dysfunction. The novel missense mutation c.142A>G (p.M48V) in BCS1L is located at a highly conserved region associated with sorting to the mitochondria. Biochemical analysis revealed an isolated complex III deficiency in skeletal muscle not detected in fibroblasts. Native polyacrylamide gel electrophoresis (PAGE) revealed normal super complex formation, but a shift in mobility of complex III most likely caused by the absence of the BCS1L-mediated insertion of Rieske Fe/S protein into complex III. These findings expand the phenotypic spectrum of BCS1L mutations, highlight the importance of biochemical analysis of different primary affected tissue and underline that neonatal lactic acidosis with multi-organ involvement may resolve after the newborn period with a relatively spared neurological outcome and survival into adulthood. CONCLUSION Mutation screening for BCS1L should be considered in the differential diagnosis of severe (proximal) tubulopathy in the newborn period. What is Known: • Mutations in BCS1L cause mitochondrial complex III deficiencies. • Phenotypic presentations of defective BCS1L range from Bjornstad to neonatal GRACILE syndrome. What is New: • Description of a novel homozygous mutation in BCS1L with transient neonatal acidosis and persistent de Toni-Debré-Fanconi-type tubulopathy. • The long survival of patients with phenotypic presentation of severe complex III deficiency is uncommon.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The current hearing health situation in the United States does not provide adequate support to individuals with hearing loss. More research is needed to give more support to these individuals. By conducting a systematic review of relevant literature from 1990 to present, I identified many factors that influence an individual's use of hearing aids. There are two research questions in this study: 1. Does the provision of screening and access to hearing aids decrease the negative effects of hearing loss? 2. Why is it difficult for people with hearing loss to adapt to and use hearing aids? The population of interest was adults (>18 years old) with hearing loss. Factors that influenced use of hearing aids for this population included age, gender, socioeconomic status, education, perceived severity of hearing loss, cost of hearing aids, screening, perceived benefit, stigmatization, perceived control, cognitive capability, personality, and social support. Research suggests that more efficient screening of at-risk individuals and the provision of better access to these individuals would prevent many of the negative effects of hearing loss.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introdução: A Hiperplasia Adrenal Congênita por deficiência da 21-hidroxilase (HAC) é uma doença com mortalidade neonatal elevada sendo elegível para programas públicos de Triagem Neonatal (TN). A HAC é causada por mutações no gene CYP21A2, as quais acarretam diferentes comprometimentos da atividade enzimática e resultam em espectro amplo de manifestações clínicas. Apesar da eficiência da TN para diagnosticar os casos graves, a taxa elevada de resultados falso-positivos (RFP), principalmente relacionados à prematuridade, é um dos maiores problemas. Porém, resultados falso-negativos também podem ocorrer em coletas antes de 24 horas de vida. No Brasil, a coleta da amostra neonatal difere entre os municípios, podendo ser no terceiro dia de vida como após. Objetivo: Avaliar se os valores da 17OH-progesterona neonatal (N17OHP) das coletas no terceiro dia de vida diferem significativamente das coletas a partir do quarto dia. Determinar qual percentil (99,5 ou 99,8) pode ser utilizado como valor de corte para a N17OHP, de acordo com o peso ao nascimento e tempo de vida na coleta, a fim de que proporcione taxa menor de RFP. Métodos: Foi avaliada, retrospectivamente, a N17OHP de 271.810 recém-nascidos (Rns) de acordo com o tempo de vida na coleta (G1: 48 - = 72h) e peso ao nascimento (P1: <= 1.500g, P2: 1.501-2.000g, P3: 2.001-2.500g e P4: >= 2.500g), pelo método imunofluorimétrico. Testes com resultados alterados foram confirmados no soro por Espectrometria de Massas em Tandem - LC-MS/MS. Rns afetados e/ou assintomáticos e com valores persistentemente elevados de 17OHP sérica foram submetidos ao estudo molécular, sequenciamento do gene CYP21A2. Resultados: os valores da N17OHP no grupo G1 foram significativamente menores do que em G2 em todos os grupos de peso (p < 0.001). A taxa de RFP em G1 e G2 foi de 0,2% para o percentil 99,8 e de 0,5% para o percentil 99,5 em ambos os grupos. O percentil 99,8 da N17OHP foi o melhor valor de corte para distinguir os Rns não afetados dos afetados, cujos valores são: G1 (P1: 120; P2: 71; P3: 39 e P4: 20 ng /mL) e em G2 (P1: 173; P2: 90; P3: 66 e P4: 25 ng/mL). Vinte e seis Rns do grupo G1 apresentaram a forma perdedora de sal (PS) (13H e 13M), nestes a N17OHP variou de 31 a 524 ng/mL e vinte Rns no grupo G2 (8H e 12M), nestes a N17OHP variou de 53 a 736 ng/mL. Para ambos os grupos foram encontrados três Rns com a forma virilizante simples (1H e 2M) e os valores da N17OHP variaram de 36 a 51 ng/mL. Resultados falso-negativos não foram relatados. O valor preditivo positivo (VPP) no teste do papel filtro foi de 5,6% e 14,1% nos grupos G1 e G2, respectivamente, ao se utilizar o percentil 99,8, e de 2,3% e 7% nos grupos G1 e G2 ao se utilizar o percentil 99,5. Dentre os casos com TN alterada (RFP), 29 deles também apresentaram 17OHP sérica elevada quando dosada por LC-MS/MS. Os casos assintomáticos foram acompanhados até normalização da 17OHP sérica e/ou submetidos ao estudo molecular, que identificou dois Rns com genótipo que prediz a forma não clássica. Conclusão: a melhor estratégia para otimização do diagnóstico da HAC na triagem neonatal é se padronizar valores de corte da N17OHP em dois grupos de acordo com o tempo de vida na coleta (antes e depois de 72 horas), subdivididos em quatro grupos de peso. A utilização dos valores de corte do percentil 99,8 se mantém eficaz no diagnóstico da HAC-21OH na triagem neonatal, reduzindo de forma significativa a taxa de RFP, sem perda do diagnóstico da forma PS

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014

Relevância:

30.00% 30.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: Failure of transfer of passive immunity (FTPI) in foals is associated with a risk of infection and death. The current diagnostic gold standard is quantification of immunoglobulins using radial immunodiffusion (IgG-RID). Routine diagnosis is often performed using semi-quantitative tests. Concentrations of serum electrophoretic gamma globulins (EGG) and total globulins may be useful to assess FTPI, but few studies have investigated their use. OBJECTIVES: To assess agreement between IgG-RID and EGG, and evaluate the accuracy of total globulin concentration to diagnose FTPI based on both IgG-RID and EGG. STUDY DESIGN: Prospective study. METHODS: 360 serum samples were harvested at 6-24 hours post natum from 60 German Warmblood foals. Concentrations of EGG, IgG-RID and total globulin concentration (calculated from total proteins and albumin) were measured. Agreement between EGG and IgG-RID was assessed using Bland-Altman plots and Passing-Bablok regression. The accuracy of total globulin concentration was assessed using rank correlation and ROC curve analysis. RESULTS: Good agreement was found with slightly lower EGG than IgG-RID concentrations (Bland-Altman systemic bias, -1.9 g/L) which was more pronounced at higher concentrations (regression equation: IgG-RID = -0.78 +1.28xEGG). Correlations between total globulin concentration and EGG, and total globulin concentration and IgG-RID were 0.93 and 0.79, respectively. The area under the curve was 0.982 and 0.952 for EGG <4 g/L and <8 g/L, and 0.953 and 0.899 for IgG-RID <4 g/L and <8 g/L. Sensitivities and specificities of total globulin concentration in the diagnosis of FTPI were comparable to commonly used screening tests, but cut-offs could be selected to achieve sensitivities of >95% with 71.2% (IgG-RID) and 90.5% (EGG) specificity for <4 g/L, and >90% with 66.0% (IgG-RID) and 87.9% (EGG) specificity for <8 g/L. CONCLUSIONS: There is good agreement between EGG and IgG-RID, with slightly more conservative estimates of immunoglobulins obtained using EGG. Total globulins may be a useful and economic quantitative screening test with cut-offs achieving high sensitivities, but analyser-specific cut-offs may be necessary. This article is protected by copyright. All rights reserved. KEYWORDS: IgG; electrophoresis; foal; globulins; horse; radial immunodiffusion. This article is protected by copyright. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have examined the feasibility of a telemedicine-enabled screening service for children and adolescents with diabetes in Queensland. There are approximately 1400 young people with diabetes in Queensland and only about two-thirds of them are screened in accordance with international guidelines. A regional retinal screening service was established using a non-mydriatic digital retinal camera. Seven centres volunteered to participate in the study. During a five-month pilot trial, 83 of the young people with diabetes who attend these centres underwent digital retinal screening (3.7%). Retinal images were sent via email to a paediatric ophthalmologist for review and results were returned via email. A copy of each participant's results was forwarded by mail to the referring diabetes doctor and the participant and family. The majority of the image files (96%) were rated as excellent or good. Only one participant was identified as having an abnormal result. Participants and their families expressed satisfaction with the digital retinal screening process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present the clinical and ophthalmological findings in two infants with neonatal Marfan syndrome (nMFS) and primary trabeculodysgenesis (PT). Fibrillin 1 (FBN1) mutations were confirmed in both cases. Numerous eye anomalies have been recognized in infants with nMFS, but PT has not been reported previously. Our report expands the phenotype of nMFS, and highlights the importance of early and careful ophthalmological assessment of these infants. (C) 2004 Wiley-Liss, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: Polysomnography (PSG) is the current standard protocol for sleep disordered breathing (SDB) investigation in children. Presently, there are limited reliable screening tests for both central (CE) and obstructive (OE) respiratory events. This study compared three indices, derived from pulse oximetry and electrocardiogram ( ECG), with the PSG gold standard. These indices were heart rate (HR) variability, arterial blood oxygen de-saturation (SaO(2)) and pulse transit time (PTT). Methods: 15 children (12 male) from routine PSG studies were recruited (aged 3 - 14 years). The characteristics of the three indices were based on known criteria for respiratory events (RPE). Their estimation singly and in combination was evaluated with simultaneous scored PSG recordings. Results: 215 RPE and 215 tidal breathing events were analysed. For OE, the obtained sensitivity was HR (0.703), SaO(2) (0.047), PTT (0.750), considering all three indices (0) and either of the indices (0.828) while specificity was (0.891), (0.938), (0.922), (0.953) and (0.859) respectively. For CE, the sensitivity was HR (0.715), SaO(2) (0.278), PTT (0.662), considering all indices (0.040) and either of the indices (0.868) while specificity was (0.815), (0.954), (0.901), (0.960) and (0.762) accordingly. Conclusions: Preliminary findings herein suggest that the later combination of these non-invasive indices to be a promising screening method of SDB in children.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Screening measures of cognitive status are traditionally administered face to face. In survey research such screening mcasurcs, while desirable, must he administered by other means. As part of pilot survey research on a New Zealand war veteran population with some degree of hearing impairment, a face-to-face administration of the Mini-Mental State Examination (MMSE; Folstein, Folstein and McHugh, 1975) and a telephoneadministration of the Telephonc Interview for Cognitive Status (TICS; Brandt, Spencer and Folstein. 1988) were compared. Brandt ('/ u/. (1988) reported a very strong linear relationship between scores on the MMSE and the TICS (r=0.94, p < .0001) in an Alzheimer patient population with a mcan MMSE score of 12.06 (6.78). For a sample of 44 mildly to moderately hearing impaired veterans, with a mean MMSE score of 25.52 (2.16) and a mean TICS score of 32.52(5.43), the correlation between the instruments was .39. When veterans who wore hearing aids during the telephone interview ( N = 2 2 ) wcrc separated out from those who did not, the correlation rose to .54. Age was ncgatively correlated with the MMSE ( r = -0.41, / I < .01) and not significantly correlated with the TICS. Education level was unrelated to either measure. The data suggest that the wearing or non-wearing of hearing aids may contribute significantly to the reliability of the TICS. Furthermore, on non-demented populations with a less restricted range of scores. the correlation of the MMSE and TICS may he lower than previously reported.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Introducing neonatal screening procedures may not be readily accepted by parents and may increase anxiety. The acceptability of pulse oximetry screening to parents has not been previously reported. Objective: To assess maternal acceptability of pulse oximetry screening for congenital heart defects and to identify factors predictive of participation in screening. Design and setting: A questionnaire was completed by a cross-sectional sample of mothers whose babies were recruited into the PulseOx Study which investigated the test accuracy of pulse oximetry screening. Participants: A total of 119 mothers of babies with false-positive (FP) results, 15 with true-positive and 679 with true-negative results following screening. Main outcome measures: Questionnaires included measures of satisfaction with screening, anxiety, depression and perceptions of test results. Results: Participants were predominantly satisfied with screening. The anxiety of mothers given FP results was not significantly higher than that of mothers given true-negative results (median score 32.7 vs 30.0, p=0.09). White British/Irish mothers were more likely to participate in screening, with a decline rate of 5%; other ethnic groups were more likely to decline with the largest increase in declining being for Black African mothers (21%, OR 4.6, 95% CI 3.8 to 5.5). White British mothers were also less anxious (p<0.001) and more satisfied (p<0.001) than those of other ethnicities Conclusions: Pulse oximetry screening was acceptable to mothers and FP results were not found to increase anxiety. Factors leading to differences in participation and satisfaction across ethnic groups need to be identified so that staff can support parents appropriately.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To assess the accuracy and acceptability of polymerase chain reaction (PCR) and optical immunoassay (OIA) tests for the detection of maternal group B streptococcus (GBS) colonisation during labour, comparing their performance with the current UK policy of risk factor-based screening. Design Diagnostic test accuracy study. Setting and population Fourteen hundred women in labour at two large UK maternity units provided vaginal and rectal swabs for testing. Methods The PCR and OIA index tests were compared with the reference standard of selective enriched culture, assessed blind to index tests. Factors influencing neonatal GBS colonisation were assessed using multiple logistic regression, adjusting for antibiotic use. The acceptability of testing to participants was evaluated through a structured questionnaire administered after delivery. Main outcome measures The sensitivity and specificity of PCR, OIA and risk factor-based screening. Results Maternal GBS colonisation was 21% (19-24%) by combined vaginal and rectal swab enriched culture. PCR test of either vaginal or rectal swabs was more sensitive (84% [79-88%] versus 72% [65-77%]) and specific (87% [85-89%] versus 57% [53-60%]) than OIA (P <0.001), and far more sensitive (84 versus 30% [25-35%]) and specific (87 versus 80% [77-82%]) than risk factor-based screening (P <0.001). Maternal antibiotics (odds ratio, 0.22 [0.07-0.62]; P = 0.004) and a positive PCR test (odds ratio, 29.4 [15.8-54.8]; P <0.001) were strongly related to neonatal GBS colonisation, whereas risk factors were not (odds ratio, 1.44 [0.80-2.62]; P = 0.2). Conclusion Intrapartum PCR screening is a more accurate predictor of maternal and neonatal GBS colonisation than is OIA or risk factor-based screening, and is acceptable to women. © RCOG 2010 BJOG An International Journal of Obstetrics and Gynaecology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introducción: La hipotiroxinemia es una alteración transitoria frecuente en el prematuro que resuelve sin medicación, es importante conocer los factores que se asocian con esta alteración para disminuir el tratamiento inoportuno y el aumento de costos en atención en salud que puede implicar un diagnóstico errado de hipotiroidismo congénito. Por medio de este estudio se evaluó la asociación entre elevación transitoria de la TSH neonatal y algunas variables asociadas a parto pretérmino en pacientes atendidos en la Clínica Materno Infantil Colsubsidio nacidos entre Enero 2014 a Abril de 2015. Metodología: Se realizó un estudio de casos y controles, analítico, retrospectivo. Los casos fueron prematuros con elevación de TSH sin hipotiroidismo congénito, los controles fueron prematuros con TSH normal, seleccionados de manera aleatoria 70 casos, 140 controles con una relación 1:2. Se realizaron asociaciones mediante prueba de chi cuadrado y análisis multivariado para controlar factores de confusión. Resultados: La edad gestacional promedio para casos fue 34.6±1.8, para controles 34.2±2.4. Ambas poblaciones fueron comparables. Los factores con resultados estadísticamente significativos fueron: Pielonefritis (p 0.04), hipertensión inducida por el embarazo (p 0.00), presencia de anemia (p 0.02) y embarazo múltiple (p0.03). Los resultados de regresión logística establecieron que la pielonefritis, hipertensión y anemia son factores de riesgo con resultados estadísticamente significativos. Discusión: Los resultados permitieron documentar que existen factores de riesgo para prematurez, como la pielonefritis, anemia materna e hipertensión inducida por el embarazo, que influyen en los valores de TSH de cordón umbilical que no necesariamente conllevan al desarrollo de hipotiroidismo congénito