943 resultados para Monte-Carlo simulation, Rod-coil block copolymer, Tetrapod polymer mixture


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A detailed characterization of a X-ray Si(Li) detector was performed to obtain the energy dependence of efficiency in the photon energy range of 6.4 - 59.5 keV. which was measured and reproduced by Monte Carlo (MC) simulations. Significant discrepancies between MC and experimental values were found when lhe manufacturer parameters of lhe detector were used in lhe simulation. A complete Computerized Tomagraphy (CT) detector scan allowed to find the correct crystal dimensions and position inside the capsule. The computed efficiencies with the resulting detector model differed with the measured values no more than 10% in most of the energy range.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Monte Carlo (MC) simulation techniques are becoming very common in the Medical Physicists community. MC can be used for modeling Single Photon Emission Computed Tomography (SPECT) and for dosimetry calculations. 188Re, is a promising candidate for radiotherapeutic production and understanding the mechanisms of the radioresponse of tumor cells "in vitro" is of crucial importance as a first step before "in vivo" studies. The dosimetry of 188Re, used to target different lines of cancer cells, has been evaluated by the MC code GEANT4. The simulations estimate the average energy deposition/per event in the biological samples. The development of prototypes for medical imaging, based on LaBr3:Ce scintillation crystals coupled with a position sensitive photomultiplier, have been studied using GEANT4 simulations. Having tested, in the simulation, surface treatments different from the one applied to the crystal used in our experimental measurements, we found out that the Energy Resolution (ER) and the Spatial Resolution (SR) could be improved, in principle, by machining in a different way the lateral surfaces of the crystal. We have then studied a system able to acquire both echographic and scintigraphic images to let the medical operator obtain the complete anatomic and functional information for tumor diagnosis. The scintigraphic part of the detector is simulated by GEANT4 and first attempts to reconstruct tomographic images have been made using as method of reconstruction a back-projection standard algorithm. The proposed camera is based on slant collimators and LaBr3:Ce crystals. Within the Field of View (FOV) of the camera, it possible to distinguish point sources located in air at a distance of about 2 cm from each other. In particular conditions of uptake, tumor depth and dimension, the preliminary results show that the Signal to Noise Ratio (SNR) values obtained are higher than the standard detection limit.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Monte Carlo-Simulationen zum kritischen Verhalten dünnerIsing-Filme Dünne Ising-Filme können als vereinfachtes Modell zurBeschreibung von binären Mischungen oder von Flüssigkeitenin schlitzartigen Kapillaren dienen. Infolge dereingeschränkten Geometrie unterscheidet sich das kritischeVerhalten dieser Systeme signifikant von dem einesBulk-Systems, es kommt zu einem Crossover von zwei- zudreidimensionalem kritischen Verhalten. Zusätzlichverschiebt sich der Phasenübergang in den ungesättigtenBereich, ein Effekt, der als 'capillary condensation'bezeichnet wird. In der vorliegenden Arbeit wurden die kritischenEigenschaften von Ising-Filmen im Rahmen einer MonteCarlo-Simulation untersucht. Zur Verbesserung der Effizienzwurde ein Cluster-Algorithmus verwendet, der um einenGhost-Spin-Term zur Behandlung der Magnetfelder erweitertwar. Bei der Datenanalyse kamen moderneMulti-Histogramm-Techniken zur Anwendung. Für alle untersuchten Schichtdicken konnten kritischeTemperatur und Magnetfeld sehr präzise bestimmt werden. DieSkalenhypothese von Fisher und Nakanishi, die dieVerschiebung des kritischen Punktes gegenüber seinesBulk-Wertes beschreibt, wurde sowohl für Systeme mit freienOberflächen als auch für Systeme mit schwachemOberflächenfeld bestätigt. Der Wert des Gap-Exponenten derOberfläche wurde mit $Delta_1$=0.459(13) in Übereinstimmungmit den Literaturwerten abgeschätzt. Die Observablen Magnetisierung und magnetischeSuszeptibilität sowie deren auf die Oberfläche bezogenenEntsprechungen zeigen kein reines zweidimensionaleskritisches Verhalten. Zu ihrer Beschreibung in der Nähe deskritischen Punktes wurden effektive Exponenten für dieeinzelnen Schichtdicken bestimmt.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oberflächengebundene flüssigkristalline Polymere innematischer Lösung - eine Monte Carlo-Untersuchung In der vorliegenden Arbeit wurde ein System vonoberflächengebundenen flüssigkristallinen Polymeren innematischer Lösung mittels Monte Carlo-Simulationen imNpT-Ensemble untersucht. Dabei wurden die Lösungsmittelteilchen und Polymerteilchen durchweiche abstoßende Ellipsoide des Durchmessers sigma_s undder Länge sigma_l modelliert. Darüber hinaus wirktenzwischen Teilchen innerhalb einer Kette zusätzliche Bondlängen- und Bondwinkelpotentiale. Die Kopfenden der Ketten waren mit ihren Mittelpunkten auf einen kubischen Gitter in der Oberfläche fixiert und wechselwirkten nicht mit den übrigen Teilchen. Für die Simulation kam ein neuartiger 'Configurationalbiased Monte Carlo'-Algorithmus zum Einsatz, mit dem esmöglich war, die Simulation stark zu beschleunigen. Dieswurde erreicht, indem die Bindungen einer Polymerkette entfernt und die ehemaligen Kettenteilchen somit zu Lösungsmittelteilchen werden. Aus den Lösungsmittelteilchen wurde dann durch das Ziehen neuer Bindungen eine neue Kette generiert, über deren Annahme dann eine Metropolisabfrage entschied. In den Simulationen sollte untersucht werden, inwieweit esmöglich ist durch Variation der Pfropfdichte einer auf eineglatte Wand aufgebrachten Polymerbürste die Richtung derOrientierung des sie quellenden Lösungsmittels zu einflussen. Neben Systemen ohne Ketten wurden Systeme mit Pfropfdichtenbis zu sigma = 0.84/sigma_s^2 über mehrere Millionen MonteCarlo-Schritte simuliert. Mit den durchgeführten Simulationen konnte gezeigt werden,daß ein Phasenübergang zwischen einer Phase mit flachentlang den Wänden ausgerichteten Teilchen und einer Phasemit Teilchen, deren Orientierung nicht parallel zur Wand ist, existiert.Dieser Phasenübergang tritt im hier betrachteten System beieiner Pfropfdichte von sigma = 0.13/sigma_s^2 auf. Weiterhin konnte bei hohen Pfropfdichten (sigma >=0.8/sigma_s^2) eine Phase mit einer Ausrichtung derLösungsmittelteilchen senkrecht zur Grundfläche gefundenwerden, obwohl die Ketten auch bei diesen Pfropfdichten nicht senkrecht stehen und die Bürste und das Lösungsmittel entkoppeln.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die vorliegende Arbeit beschäftigt sich mit demAdsorptionsverhalten von Homo- und Blockopolymeren anglatten Wänden im guten Lösungsmittel. Zur Modellierung wirddabei ein vergröbertes Kugel-Feder-Modell benutzt, das diePolymere als Kette von effektiven Monomeren auffasst.Benachbarte Monomere einer Kette werden durch einBindungspotential aneinander gekoppelt; zusätzlich wird eineVolumenausschlusswechselwirkung zwischen allen Monomeren derLösung berücksichtigt. Das Lösungsmittel wird dabei implizitdurch diese effektiven Potentiale berücksichtigt, wobei dieLösungsmittelqualität über die Temperatur geregelt wird.Während das System in z-Richtung durch zwei ebene Wändebegrenzt wird, von denen eine attraktiv mit den Monomerenwechselwirkt, werden in x- und y-Richtung periodischeRandbedingungen vorgegeben. Die Bewegung der Polymereerfolgt durch Monte Carlo-Simulationen im räumlichenKontinuum, welche auf (großkanonischen) Configurational BiasMonte Carlo-Algorithmen sowie lokalen Monomerverschiebungenund Reptationsbewegungen basieren.Über verschiedene Auswertemethoden werden anhand vonEinzelkettensimulationen die (modellabhängige)Adsorptionsschwelle - welche durch Simualtionen derAdsorption aus der Lösung bestätigt wird - sowie der(universelle) Crossoverexponent - dessen gefundener Wertsehr gut mit den neusten analytischen Berechnungenübereinstimmt - bestimmt. Bei der Simulation derBlockcopolymere bilden sich bei niedrigerOberflächenbelegungsdichte pilzartige Konformationen('mushroom'-Bereich), bei hoher OberflächenbelegungsdichtePolymerbürsten ('brush'-Bereich). Die theoretischenVorhersagen für den jeweiligen Bereich werden von denSimulationen im Wesentlichen gut wiedergegeben.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Das Phasenverhalten und die Grenzflächeneigenschaften vonPolymeren in superkritischer Lösung werden anhand einesvergröberten Kugel-Feder-Modells für das ReferenzsystemHexadekan-CO2 untersucht. Zur Bestimmung der Parameter imPotential setzt man die kritischen Punkte von Simulation undExperiment gleich. Wechselwirkungen zwischen beidenKomponenten werden durch eine modifizierteLorentz-Berthelot-Regel modelliert. Die Übereinstimmung mitden Experimenten ist sehr gut - insbesondere kann dasPhasendiagramm des Mischsystems inklusive kritischer Linienreproduziert werden. Ein Vergleich mit numerischenStörungsrechnungen (TPT1) liefert eine qualitativeÜbereinstimmung und Hinweise zur Verbesserung derverwendeten Zustandsgleichung. Aufbauend auf diesen Betrachtungen werden die Frühstadiender Keimbildung untersucht. Für das Lennard-Jones-Systemwird zum ersten Mal der Übergang vom homogenen Gas zu einemeinzelnen Tropfen im endlichen Volumen direkt nachgewiesenund quantifiziert. Die freie Energie von kleinen Clusternwird mit einem einfachen, klassischen Nukleationsmodellbestimmt und nach oben abgeschätzt. Die vorgestellten Untersuchungen wurden durch eineWeiterentwicklung des Umbrella-Sampling-Algorithmusermöglicht. Hierbei wird die Simulation in mehrereSimulationsfenster unterteilt, die nacheinander abgearbeitetwerden. Die Methode erlaubt eine Bestimmung derFreien-Energie-Landschaft an einer beliebigen Stelle desPhasendiagramms. Der Fehler ist kontrollierbar undunabhängig von der Art der Unterteilung.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Supernovae are among the most energetic events occurring in the universe and are so far the only verified extrasolar source of neutrinos. As the explosion mechanism is still not well understood, recording a burst of neutrinos from such a stellar explosion would be an important benchmark for particle physics as well as for the core collapse models. The neutrino telescope IceCube is located at the Geographic South Pole and monitors the antarctic glacier for Cherenkov photons. Even though it was conceived for the detection of high energy neutrinos, it is capable of identifying a burst of low energy neutrinos ejected from a supernova in the Milky Way by exploiting the low photomultiplier noise in the antarctic ice and extracting a collective rate increase. A signal Monte Carlo specifically developed for water Cherenkov telescopes is presented. With its help, we will investigate how well IceCube can distinguish between core collapse models and oscillation scenarios. In the second part, nine years of data taken with the IceCube precursor AMANDA will be analyzed. Intensive data cleaning methods will be presented along with a background simulation. From the result, an upper limit on the expected occurrence of supernovae within the Milky Way will be determined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Little is known about the learning of the skills needed to perform ultrasound- or nerve stimulator-guided peripheral nerve blocks. The aim of this study was to compare the learning curves of residents trained in ultrasound guidance versus residents trained in nerve stimulation for axillary brachial plexus block. Ten residents with no previous experience with using ultrasound received ultrasound training and another ten residents with no previous experience with using nerve stimulation received nerve stimulation training. The novices' learning curves were generated by retrospective data analysis out of our electronic anaesthesia database. Individual success rates were pooled, and the institutional learning curve was calculated using a bootstrapping technique in combination with a Monte Carlo simulation procedure. The skills required to perform successful ultrasound-guided axillary brachial plexus block can be learnt faster and lead to a higher final success rate compared to nerve stimulator-guided axillary brachial plexus block.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Monte Carlo (MC) based dose calculations can compute dose distributions with an accuracy surpassing that of conventional algorithms used in radiotherapy, especially in regions of tissue inhomogeneities and surface discontinuities. The Swiss Monte Carlo Plan (SMCP) is a GUI-based framework for photon MC treatment planning (MCTP) interfaced to the Eclipse treatment planning system (TPS). As for any dose calculation algorithm, also the MCTP needs to be commissioned and validated before using the algorithm for clinical cases. Aim of this study is the investigation of a 6 MV beam for clinical situations within the framework of the SMCP. In this respect, all parts i.e. open fields and all the clinically available beam modifiers have to be configured so that the calculated dose distributions match the corresponding measurements. Dose distributions for the 6 MV beam were simulated in a water phantom using a phase space source above the beam modifiers. The VMC++ code was used for the radiation transport through the beam modifiers (jaws, wedges, block and multileaf collimator (MLC)) as well as for the calculation of the dose distributions within the phantom. The voxel size of the dose distributions was 2mm in all directions. The statistical uncertainty of the calculated dose distributions was below 0.4%. Simulated depth dose curves and dose profiles in terms of [Gy/MU] for static and dynamic fields were compared with the corresponding measurements using dose difference and γ analysis. For the dose difference criterion of ±1% of D(max) and the distance to agreement criterion of ±1 mm, the γ analysis showed an excellent agreement between measurements and simulations for all static open and MLC fields. The tuning of the density and the thickness for all hard wedges lead to an agreement with the corresponding measurements within 1% or 1mm. Similar results have been achieved for the block. For the validation of the tuned hard wedges, a very good agreement between calculated and measured dose distributions was achieved using a 1%/1mm criteria for the γ analysis. The calculated dose distributions of the enhanced dynamic wedges (10°, 15°, 20°, 25°, 30°, 45° and 60°) met the criteria of 1%/1mm when compared with the measurements for all situations considered. For the IMRT fields all compared measured dose values agreed with the calculated dose values within a 2% dose difference or within 1 mm distance. The SMCP has been successfully validated for a static and dynamic 6 MV photon beam, thus resulting in accurate dose calculations suitable for applications in clinical cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although the Monte Carlo (MC) method allows accurate dose calculation for proton radiotherapy, its usage is limited due to long computing time. In order to gain efficiency, a new macro MC (MMC) technique for proton dose calculations has been developed. The basic principle of the MMC transport is a local to global MC approach. The local simulations using GEANT4 consist of mono-energetic proton pencil beams impinging perpendicularly on slabs of different thicknesses and different materials (water, air, lung, adipose, muscle, spongiosa, cortical bone). During the local simulation multiple scattering, ionization as well as elastic and inelastic interactions have been taken into account and the physical characteristics such as lateral displacement, direction distributions and energy loss have been scored for primary and secondary particles. The scored data from appropriate slabs is then used for the stepwise transport of the protons in the MMC simulation while calculating the energy loss along the path between entrance and exit position. Additionally, based on local simulations the radiation transport of neutrons and the generated ions are included into the MMC simulations for the dose calculations. In order to validate the MMC transport, calculated dose distributions using the MMC transport and GEANT4 have been compared for different mono-energetic proton pencil beams impinging on different phantoms including homogeneous and inhomogeneous situations as well as on a patient CT scan. The agreement of calculated integral depth dose curves is better than 1% or 1 mm for all pencil beams and phantoms considered. For the dose profiles the agreement is within 1% or 1 mm in all phantoms for all energies and depths. The comparison of the dose distribution calculated using either GEANT4 or MMC in the patient also shows an agreement of within 1% or 1 mm. The efficiency of MMC is up to 200 times higher than for GEANT4. The very good level of agreement in the dose comparisons demonstrate that the newly developed MMC transport results in very accurate and efficient dose calculations for proton beams.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Markov chain Monte Carlo is a method of producing a correlated sample in order to estimate features of a complicated target distribution via simple ergodic averages. A fundamental question in MCMC applications is when should the sampling stop? That is, when are the ergodic averages good estimates of the desired quantities? We consider a method that stops the MCMC sampling the first time the width of a confidence interval based on the ergodic averages is less than a user-specified value. Hence calculating Monte Carlo standard errors is a critical step in assessing the output of the simulation. In particular, we consider the regenerative simulation and batch means methods of estimating the variance of the asymptotic normal distribution. We describe sufficient conditions for the strong consistency and asymptotic normality of both methods and investigate their finite sample properties in a variety of examples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Currently photon Monte Carlo treatment planning (MCTP) for a patient stored in the patient database of a treatment planning system (TPS) can usually only be performed using a cumbersome multi-step procedure where many user interactions are needed. This means automation is needed for usage in clinical routine. In addition, because of the long computing time in MCTP, optimization of the MC calculations is essential. For these purposes a new graphical user interface (GUI)-based photon MC environment has been developed resulting in a very flexible framework. By this means appropriate MC transport methods are assigned to different geometric regions by still benefiting from the features included in the TPS. In order to provide a flexible MC environment, the MC particle transport has been divided into different parts: the source, beam modifiers and the patient. The source part includes the phase-space source, source models and full MC transport through the treatment head. The beam modifier part consists of one module for each beam modifier. To simulate the radiation transport through each individual beam modifier, one out of three full MC transport codes can be selected independently. Additionally, for each beam modifier a simple or an exact geometry can be chosen. Thereby, different complexity levels of radiation transport are applied during the simulation. For the patient dose calculation, two different MC codes are available. A special plug-in in Eclipse providing all necessary information by means of Dicom streams was used to start the developed MC GUI. The implementation of this framework separates the MC transport from the geometry and the modules pass the particles in memory; hence, no files are used as the interface. The implementation is realized for 6 and 15 MV beams of a Varian Clinac 2300 C/D. Several applications demonstrate the usefulness of the framework. Apart from applications dealing with the beam modifiers, two patient cases are shown. Thereby, comparisons are performed between MC calculated dose distributions and those calculated by a pencil beam or the AAA algorithm. Interfacing this flexible and efficient MC environment with Eclipse allows a widespread use for all kinds of investigations from timing and benchmarking studies to clinical patient studies. Additionally, it is possible to add modules keeping the system highly flexible and efficient.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article proposes computing sensitivities of upper tail probabilities of random sums by the saddlepoint approximation. The considered sensitivity is the derivative of the upper tail probability with respect to the parameter of the summation index distribution. Random sums with Poisson or Geometric distributed summation indices and Gamma or Weibull distributed summands are considered. The score method with importance sampling is considered as an alternative approximation. Numerical studies show that the saddlepoint approximation and the method of score with importance sampling are very accurate. But the saddlepoint approximation is substantially faster than the score method with importance sampling. Thus, the suggested saddlepoint approximation can be conveniently used in various scientific problems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this second part of our comparative study inspecting the (dis)similarities between “Stokes” and “Jones,” we present simulation results yielded by two independent Monte Carlo programs: (i) one developed in Bern with the Jones formalism and (ii) the other implemented in Ulm with the Stokes notation. The simulated polarimetric experiments involve suspensions of polystyrene spheres with varying size. Reflection and refraction at the sample/air interfaces are also considered. Both programs yield identical results when propagating pure polarization states, yet, with unpolarized illumination, second order statistical differences appear, thereby highlighting the pre-averaged nature of the Stokes parameters. This study serves as a validation for both programs and clarifies the misleading belief according to which “Jones cannot treat depolarizing effects.”

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Kinetic Monte Carlo (KMC) is a widely used technique to simulate the evolution of radiation damage inside solids. Despite de fact that this technique was developed several decades ago, there is not an established and easy to access simulating tool for researchers interested in this field, unlike in the case of molecular dynamics or density functional theory calculations. In fact, scientists must develop their own tools or use unmaintained ones in order to perform these types of simulations. To fulfil this need, we have developed MMonCa, the Modular Monte Carlo simulator. MMonCa has been developed using professional C++ programming techniques and has been built on top of an interpreted language to allow having a powerful yet flexible, robust but customizable and easy to access modern simulator. Both non lattice and Lattice KMC modules have been developed. We will present in this conference, for the first time, the MMonCa simulator. Along with other (more detailed) contributions in this meeting, the versatility of MMonCa to study a number of problems in different materials (particularly, Fe and W) subject to a wide range of conditions will be shown. Regarding KMC simulations, we have studied neutron-generated cascade evolution in Fe (as a model material). Starting with a Frenkel pair distribution we have followed the defect evolution up to 450 K. Comparison with previous simulations and experiments shows excellent agreement. Furthermore, we have studied a more complex system (He-irradiated W:C) using a previous parametrization [1]. He-irradiation at 4 K followed by isochronal annealing steps up to 500 K has been simulated with MMonCa. The He energy was 400 eV or 3 keV. In the first case, no damage is associated to the He implantation, whereas in the second one, a significant Frenkel pair concentration (evolving into complex clusters) is associated to the He ions. We have been able to explain He desorption both in the absence and in the presence of Frenkel pairs and we have also applied MMonCa to high He doses and fluxes at elevated temperatures. He migration and trapping dominate the kinetics of He desorption. These processes will be discussed and compared to experimental results. [1] C.S. Becquart et al. J. Nucl. Mater. 403 (2010) 75