876 resultados para Load voltage maximization


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of fiber reinforced plastics has increased in the last decades due to their unique properties. Advantages of their use are related with low weight, high strength and stiffness. Drilling of composite plates can be carried out in conventional machinery with some adaptations. However, the presence of typical defects like delamination can affect mechanical properties of produced parts. In this paper delamination influence in bearing stress of drilled hybrid carbon+glass/epoxy quasi-isotropic plates is studied by using image processing and analysis techniques. Results from bearing test show that damage minimization is an important mean to improve mechanical properties of the joint area of the plate. The appropriateness of the image processing and analysis techniques used in the measurement of the damaged area is demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The operation of generalized Marx-type solid-state bipolar modulators is discussed and compared with simplified Marx-derived circuits, to evaluate their capability to deal with various load conditions. A comparative analysis on the number of switches per cell, fiber optic trigger count, losses, and switch hold-off voltages has been made. A circuit topology is obtained as a compromise in terms of operating performance, trigger simplicity, and switching losses. A five-stage laboratory prototype of this circuit has been assembled using 1200 V insulated gate bipolar transistors (IGBTs) and diodes, operating with 1000 V dc input voltage and 1 kHz frequency, giving 5 kV bipolar pulses, with 2.5 mu s pulse width and 5 mu s relaxation time into resistive, capacitive, and inductive loads.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper models an n-stage stacked Blumlein generator for bipolar pulses for various load conditions. Calculation of the voltage amplitudes in time domain at the load and between stages is described for an n-stage generator. For this, the reflection and transmission coefficients are mathematically modeled where impedance discontinuity occurs (i.e., at the junctions between two transmission lines). The mathematical model developed is assessed by comparing simulation results to experimental data from a two-stage Blumlein solid-state prototype.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IEEE International Symposium on Circuits and Systems, MAY 25-28, 2003, Bangkok, Thailand. (ISI Web of Science)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hoje em dia as fontes de alimentação possuem correção do fator de potência, devido às diversas normas regulamentares existentes, que introduziram grandes restrições no que respeita à distorção harmónica (THD) e fator de potência (FP). Este trabalho trata da análise, desenvolvimento e implementação de um Pré-Regulador de fator de potência com controlo digital. O controlo digital de conversores com recurso a processamento digital de sinal tem vindo a ser ao longo dos últimos anos, objeto de investigação e desenvolvimento, estando constantemente a surgirem modificações nas topologias existentes. Esta dissertação tem como objetivo estudar e implementar um Pré-Regulador Retificador Boost e o respetivo controlo digital. O controlo do conversor é feito através da técnica dos valores médios instantâneos da corrente de entrada, desenvolvido através da linguagem de descrição de hardware VHDL (VHSIC HDL – Very High Speed Integrated Circuit Hardware Description Language) e implementado num dispositivo FPGA (Field Programmable Gate Array) Spartan-3E. Neste trabalho são apresentadas análises matemáticas, para a obtenção das funções de transferência pertinentes ao projeto dos controladores. Para efetuar este controlo é necessário adquirir os sinais da corrente de entrada, tensão de entrada e tensão de saída. O sinal resultante do módulo de controlo é um sinal de PWM com valor de fator de ciclo variável ao longo do tempo. O projeto é simulado e validado através da plataforma MatLab/Simulink e PSIM, onde são apresentados resultados para o regime permanente e para transitórios da carga e da tensão de alimentação. Finalmente, o Pré-Regulador Retificador Boost controlado de forma digital é implementado em laboratório. Os resultados experimentais são apresentados para validar a metodologia e o projeto desenvolvidos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dificuldade de controlo de um motor de indução, bem como o armazenamento de energia CC e posterior utilização como energia alternada promoveram o desenvolvimento de variadores de frequência e inversores. Assim, como projeto de tese de mestrado em Automação e Sistemas surge o desenvolvimento de um variador de frequência. Para elaboração do variador de frequência efetuou-se um estudo sobre as técnicas de modulação utilizadas nos inversores. A técnica escolhida e utilizada é a Sinusoidal Pulse Width Modulation (SPWM). Esta técnica baseia-se na modelação por largura de impulso (PWM), o qual é formado por comparação de um sinal de referência com um sinal de portadora de elevada frequência. Por sua vez, a topologia escolhida para o inversor corresponde a um Voltage Source Inverter (VSI) de ponte trifásica completa a três terminais. O desenvolvimento da técnica de modulação SPWM levou ao desenvolvimento de um modelo de simulação em SIMULINK, o qual permitiu retirar conclusões sobre os resultados obtidos. Na fase de implementação, foram desenvolvidas placas para o funcionamento do variador de frequência. Assim, numa fase inicial foi desenvolvida a placa de controlo, a qual contém a unidade de processamento e que é responsável pela atuação de Insulated Gate Bipolar Transistors (IGBTs). Para além disso, foi desenvolvida uma placa para proteção dos IGBTs (evitando condução simultânea no mesmo terminal) e uma placa de fontes isoladas para alimentação dos circuitos e para atuação dos IGBTs. Ainda, foi desenvolvida a técnica de SPWM em software para a unidade de controlo e finalmente foi desenvolvida uma interface gráfica para interação com o utilizador. A validação do projeto foi conseguida através da variação da velocidade do motor de indução trifásico. Para isso, este foi colocado a funcionar a diversas frequências de funcionamento e a diferentes amplitudes. Para além disso, o seu funcionamento foi também validado utilizando uma carga trifásica equilibrada de 3 lâmpadas de forma a ser visualizada a variação de frequência e variação de amplitude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IEEE International Symposium on Circuits and Systems, pp. 2713 – 2716, Seattle, EUA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a model for the simulation of an offshore wind system having a rectifier input voltage malfunction at one phase. The offshore wind system model comprises a variable-speed wind turbine supported on a floating platform, equipped with a permanent magnet synchronous generator using full-power four-level neutral point clamped converter. The link from the offshore floating platform to the onshore electrical grid is done through a light high voltage direct current submarine cable. The drive train is modeled by a three-mass model. Considerations about the smart grid context are offered for the use of the model in such a context. The rectifier voltage malfunction domino effect is presented as a case study to show capabilities of the model. (C) 2015 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In future power systems, in the smart grid and microgrids operation paradigms, consumers can be seen as an energy resource with decentralized and autonomous decisions in the energy management. It is expected that each consumer will manage not only the loads, but also small generation units, heating systems, storage systems, and electric vehicles. Each consumer can participate in different demand response events promoted by system operators or aggregation entities. This paper proposes an innovative method to manage the appliances on a house during a demand response event. The main contribution of this work is to include time constraints in resources management, and the context evaluation in order to ensure the required comfort levels. The dynamic resources management methodology allows a better resources’ management in a demand response event, mainly the ones of long duration, by changing the priorities of loads during the event. A case study with two scenarios is presented considering a demand response with 30 min duration, and another with 240 min (4 h). In both simulations, the demand response event proposes the power consumption reduction during the event. A total of 18 loads are used, including real and virtual ones, controlled by the presented house management system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo Energia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sustentabilidade energética do planeta é uma preocupação corrente e, neste sentido, a eficiência energética afigura-se como sendo essencial para a redução do consumo em todos os setores de atividade. No que diz respeito ao setor residencial, o indevido comportamento dos utilizadores aliado ao desconhecimento do consumo dos diversos aparelhos, são factores impeditivos para a redução do consumo energético. Uma ferramenta importante, neste sentido, é a monitorização de consumos nomeadamente a monitorização não intrusiva, que apresenta vantagens económicas relativamente à monitorização intrusiva, embora levante alguns desafios na desagregação de cargas. Abordou-se então, neste documento, a temática da monitorização não intrusiva onde se desenvolveu uma ferramenta de desagregação de cargas residenciais, sobretudo de aparelhos que apresentavam elevados consumos. Para isso, monitorizaram-se os consumos agregados de energia elétrica, água e gás de seis habitações do município de Vila Nova de Gaia. Através da incorporação dos vetores de água e gás, a acrescentar ao da energia elétrica, provou-se que a performance do algoritmo de desagregação de aparelhos poderá aumentar, no caso de aparelhos que utilizem simultaneamente energia elétrica e água ou energia elétrica e gás. A eficiência energética é também parte constituinte deste trabalho e, para tal, implementaram-se medidas de eficiência energética para uma das habitações em estudo, de forma a concluir as que exibiam maior potencial de poupança, assim como rápidos períodos de retorno de investimento. De um modo geral, os objetivos propostos foram alcançados e espera-se que num futuro próximo, a monitorização de consumos não intrusiva se apresente como uma solução de referência no que respeita à sustentabilidade energética do setor residencial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent data suggest that the clinical course of reactional states in leprosy is closely related to the cytokine profile released locally or systemically by the patients. In the present study, patients with erythema nodosum leprosum (ENL) were grouped according to the intensity of their clinical symptoms. Clinical and immunological aspects of ENL and the impact of these parameters on bacterial load were assessed in conjunction with patients' in vitro immune response to mycobacterial antigens. In 10 out of the 17 patients tested, BI (bacterial index) was reduced by at least 1 log from leprosy diagnosis to the onset of their first reactional episode (ENL), as compared to an expected 0.3 log reduction in the unreactional group for the same MDT (multidrug therapy) period. However, no difference in the rate of BI reduction was noted at the end of MDT among ENL and unreactional lepromatous patients. Accordingly, although TNF-alpha (tumor necrosis factor) levels were enhanced in the sera of 70.6% of the ENL patients tested, no relationship was noted between circulating TNF-alpha levels and the decrease in BI detected at the onset of the reactional episode. Evaluation of bacterial viability of M. leprae isolated from the reactional lesions showed no growth in the mouse footpads. Only 20% of the patients demonstrated specific immune response to M. leprae during ENL. Moreover, high levels of soluble IL-2R (interleukin-2 receptor) were present in 78% of the patients. Circulating anti-neural (anti-ceramide and anti-galactocerebroside antibodies) and anti-mycobacterial antibodies were detected in ENL patients' sera as well, which were not related to the clinical course of disease. Our data suggest that bacterial killing is enhanced during reactions. Emergence of specific immune response to M. leprae and the effective role of TNF-alpha in mediating fragmentation of bacteria still need to be clarified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The deregulation of electricity markets has diversified the range of financial transaction modes between independent system operator (ISO), generation companies (GENCO) and load-serving entities (LSE) as the main interacting players of a day-ahead market (DAM). LSEs sell electricity to end-users and retail customers. The LSE that owns distributed generation (DG) or energy storage units can supply part of its serving loads when the nodal price of electricity rises. This opportunity stimulates them to have storage or generation facilities at the buses with higher locational marginal prices (LMP). The short-term advantage of this model is reducing the risk of financial losses for LSEs in DAMs and its long-term benefit for the LSEs and the whole system is market power mitigation by virtually increasing the price elasticity of demand. This model also enables the LSEs to manage the financial risks with a stochastic programming framework.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of demand response programs enables the adequate use of resources of small and medium players, bringing high benefits to the smart grid, and increasing its efficiency. One of the difficulties to proceed with this paradigm is the lack of intelligence in the management of small and medium size players. In order to make demand response programs a feasible solution, it is essential that small and medium players have an efficient energy management and a fair optimization mechanism to decrease the consumption without heavy loss of comfort, making it acceptable for the users. This paper addresses the application of real-time pricing in a house that uses an intelligent optimization module involving artificial neural networks.