399 resultados para LOD
Resumo:
This article proposes a simple and sensitive HPLC method with photo-diode array detection for the analysis of organic acids, monomeric polyphenols and furanic compounds in wine samples by direct injection. The chromatographic separation of 8 organic acids, 2 furans and 22 phenolic compounds was carried out with a buffered solution (pH 2.70) and acetonitrile as mobile phases and a difunctionally bonded C18 stationary phase, Atlantis dC18 (250 4.6 mm, 5mm) column. The elution was performed in 12 min for the organic acids and in 60 min for the phenolic compounds, including phenolic acids, stilbenes and flavonoids. Target compounds were detected at 210 nm (organic acids, flavan-3-ols and benzoic acids), 254 nm (ellagic acid), 280 nm (furans and cinnamic acid), 315 nm (hydroxycinnamic acids and trans-resveratrol) and 360 nm (flavonoids). The RSD for the repeatability test (n55) of peak area and retention times were below 3.1 and 0.3%, respectively, for phenolics and below 1.0 and 0.2% for organic acids. The RSDs expressing the reproducibility of the method were higher than for the repeatability results but all below 9.0%. Method accuracy was evaluated by the recovery results, with averaged values between 80 and 104% for polyphenols and 97–105% for organic acids. The calibration curves, obtained by triplicate injection of standard solutions, showed good linearity with regression coefficients higher than 0.9982 for polyphenols and 0.9997 for organic acids. The LOD was in the range of 0.07–0.49 mg/L for polyphenols (cinnamic and gallic acids, respectively) and 0.001–0.046 g/L for organic acids (oxalic and lactic acids, respectively). The method was successfully used to measure and assess the polyphenolic fingerprint and organic acids profile of red, white, rose ´ and fortified wines.
Resumo:
A novel analytical approach, based on a miniaturized extraction technique, the microextraction by packed sorbent (MEPS), followed by ultrahigh pressure liquid chromatography (UHPLC) separation combined with a photodiode array (PDA) detection, has been developed and validated for the quantitative determination of sixteen biologically active phenolic constituents of wine. In addition to performing routine experiments to establish the validity of the assay to internationally accepted criteria (linearity, sensitivity, selectivity, precision, accuracy), experiments are included to assess the effect of the important experimental parameters on the MEPS performance such as the type of sorbent material (C2, C8, C18, SIL, and M1), number of extraction cycles (extract-discard), elution volume, sample volume, and ethanol content, were studied. The optimal conditions of MEPS extraction were obtained using C8 sorbent and small sample volumes (250 μL) in five extraction cycle and in a short time period (about 5 min for the entire sample preparation step). The wine bioactive phenolics were eluted by 250 μL of the mixture containing 95% methanol and 5% water, and the separation was carried out on a HSS T3 analytical column (100 mm × 2.1 mm, 1.8 μm particle size) using a binary mobile phase composed of aqueous 0.1% formic acid (eluent A) and methanol (eluent B) in the gradient elution mode (10 min of total analysis). The method gave satisfactory results in terms of linearity with r2-values > 0.9986 within the established concentration range. The LOD varied from 85 ng mL−1 (ferulic acid) to 0.32 μg mL−1 ((+)-catechin), whereas the LOQ values from 0.028 μg mL−1 (ferulic acid) to 1.08 μg mL−1 ((+)-catechin). Typical recoveries ranged between 81.1 and 99.6% for red wines and between 77.1 and 99.3% for white wines, with relative standard deviations (RSD) no larger than 10%. The extraction yields of the MEPSC8/UHPLC–PDA methodology were found between 78.1 (syringic acid) and 99.6% (o-coumaric acid) for red wines and between 76.2 and 99.1% for white wines. The inter-day precision, expressed as the relative standard deviation (RSD%), varied between 0.2% (p-coumaric and o-coumaric acids) and 7.5% (gentisic acid) while the intra-day precision between 0.2% (o-coumaric and cinnamic acids) and 4.7% (gallic acid and (−)-epicatechin). On the basis of analytical validation, it is shown that the MEPSC8/UHPLC–PDA methodology proves to be an improved, reliable, and ultra-fast approach for wine bioactive phenolics analysis, because of its capability for determining simultaneously in a single chromatographic run several bioactive metabolites with high sensitivity, selectivity and resolving power within only 10 min. Preliminary studies have been carried out on 34 real whole wine samples, in order to assess the performance of the described procedure. The new approach offers decreased sample preparation and analysis time, and moreover is cheaper, more environmentally friendly and easier to perform as compared to traditional methodologies.
Resumo:
This paper reports on the development and optimization of a modified Quick, Easy, Cheap Effective, Rugged and Safe (QuEChERS) based extraction technique coupled with a clean-up dispersive-solid phase extraction (dSPE) as a new, reliable and powerful strategy to enhance the extraction efficiency of free low molecular-weight polyphenols in selected species of dietary vegetables. The process involves two simple steps. First, the homogenized samples are extracted and partitioned using an organic solvent and salt solution. Then, the supernatant is further extracted and cleaned using a dSPE technique. Final clear extracts of vegetables were concentrated under vacuum to near dryness and taken up into initial mobile phase (0.1% formic acid and 20% methanol). The separation and quantification of free low molecular weight polyphenols from the vegetable extracts was achieved by ultrahigh pressure liquid chromatography (UHPLC) equipped with a phodiode array (PDA) detection system and a Trifunctional High Strength Silica capillary analytical column (HSS T3), specially designed for polar compounds. The performance of the method was assessed by studying the selectivity, linear dynamic range, the limit of detection (LOD) and limit of quantification (LOQ), precision, trueness, and matrix effects. The validation parameters of the method showed satisfactory figures of merit. Good linearity (View the MathML sourceRvalues2>0.954; (+)-catechin in carrot samples) was achieved at the studied concentration range. Reproducibility was better than 3%. Consistent recoveries of polyphenols ranging from 78.4 to 99.9% were observed when all target vegetable samples were spiked at two concentration levels, with relative standard deviations (RSDs, n = 5) lower than 2.9%. The LODs and the LOQs ranged from 0.005 μg mL−1 (trans-resveratrol, carrot) to 0.62 μg mL−1 (syringic acid, garlic) and from 0.016 μg mL−1 (trans-resveratrol, carrot) to 0.87 μg mL−1 ((+)-catechin, carrot) depending on the compound. The method was applied for studying the occurrence of free low molecular weight polyphenols in eight selected dietary vegetables (broccoli, tomato, carrot, garlic, onion, red pepper, green pepper and beetroot), providing a valuable and promising tool for food quality evaluation.
Resumo:
This study provides a versatile validated method to determine the total vitamin C content, as the sum of the contents of L-ascorbic acid (L-AA) and dehydroascorbic acid (DHAA), in several fruits and vegetables and its degradability with storage time. Seven horticultural crops from two different origins were analyzed using an ultrahigh-performance liquid chromatographic–photodiode array (UHPLC-PDA) system, equipped with a new trifunctional high strength silica (100% silica particle) analytical column (100 mm×2.1 mm, 1.7 μm particle size) using 0.1% (v/v) formic acid as mobile phase, in isocratic mode. This new stationary phase, specially designed for polar compounds, overcomes the problems normally encountered in HPLC and is suitable for the analysis of large batches of samples without L-AA degradation. In addition, it proves to be an excellent alternative to conventional C18 columns for the determination of L-AA in fruits and vegetables. The method was fully validated in terms of linearity, detection (LOD) and quantification (LOQ) limits, accuracy, and inter/intraday precision. Validation experiments revealed very good recovery rate of 96.6±4.4% for L-AA and 103.1±4.8 % for total vitamin C, good linearity with r2-values >0.999 within the established concentration range, excellent repeatability (0.5%), and reproducibility (1.6%) values. The LOD of the method was 22 ng/mL whereas the LOQ was 67 ng/mL. It was possible to demonstrate that L-AA and DHAA concentrations in the different horticulture products varied oppositely with time of storage not always affecting the total amount of vitamin C during shelf-life. Locally produced fruits have higher concentrations of vitamin C, compared with imported ones, but vegetables showed the opposite trend. Moreover, this UHPLC-PDA methodology proves to be an improved, simple, and fast approach for determining the total content of vitamin C in various food commodities, with high sensitivity, selectivity, and resolving power within 3 min of run analysis.
Resumo:
This manuscript describes the development and validation of an ultra-fast, efficient, and high throughput analytical method based on ultra-high performance liquid chromatography (UHPLC) equipped with a photodiode array (PDA) detection system, for the simultaneous analysis of fifteen bioactive metabolites: gallic acid, protocatechuic acid, (−)-catechin, gentisic acid, (−)-epicatechin, syringic acid, p-coumaric acid, ferulic acid, m-coumaric acid, rutin, trans-resveratrol, myricetin, quercetin, cinnamic acid and kaempferol, in wines. A 50-mm column packed with 1.7-μm particles operating at elevated pressure (UHPLC strategy) was selected to attain ultra-fast analysis and highly efficient separations. In order to reduce the complexity of wine extract and improve the recovery efficiency, a reverse-phase solid-phase extraction (SPE) procedure using as sorbent a new macroporous copolymer made from a balanced ratio of two monomers, the lipophilic divinylbenzene and the hydrophilic N-vinylpyrrolidone (Oasis™ HLB), was performed prior to UHPLC–PDA analysis. The calibration curves of bioactive metabolites showed good linearity within the established range. Limits of detection (LOD) and quantification (LOQ) ranged from 0.006 μg mL−1 to 0.58 μg mL−1, and from 0.019 μg mL−1 to 1.94 μg mL−1, for gallic and gentisic acids, respectively. The average recoveries ± SD for the three levels of concentration tested (n = 9) in red and white wines were, respectively, 89 ± 3% and 90 ± 2%. The repeatability expressed as relative standard deviation (RSD) was below 10% for all the metabolites assayed. The validated method was then applied to red and white wines from different geographical origins (Azores, Canary and Madeira Islands). The most abundant component in the analysed red wines was (−)-epicatechin followed by (−)-catechin and rutin, whereas in white wines syringic and p-coumaric acids were found the major phenolic metabolites. The method was completely validated, providing a sensitive analysis for bioactive phenolic metabolites detection and showing satisfactory data for all the parameters tested. Moreover, was revealed as an ultra-fast approach allowing the separation of the fifteen bioactive metabolites investigated with high resolution power within 5 min.
Resumo:
A large number of evidences correlate elevated levels of homocysteine (Hcys) with a higher cardiovascular diseases (CVDs) risk, especially, atherosclerosis. Similarly, abnormal low levels of the vitamins B6, B9 and B12 are associated to an instability in the methionine cycle with an over production of Hcys. Thus, biomedical sciences are looking forward for a cheaper, faster, precise and accurate analytical methodology to quantify these compounds in a suitable format for the clinical environment. Therefore the objective of this study was the development of a simple, inexpensive and appropriate methodology to use at the clinical level. To achieve this goal, a procedure integrating a digitally controlled (eVol®) microextraction by packed sorbent (MEPS) and an ultra performance liquid chromatography (UPLC) coupled to a photodiode array detector (PDA) was developed to identify and quantify Hcys vitamins B6, B9 and B12. Although different conditions were assayed, we were not able to combine Hcys with the vitamins in the same analytical procedure, and so we proceeded to the optimization of two methods differing only in the composition of the gradient of the mobile phase and the injected volume. It was found that MEPS did not bring any benefit to the quantification of the Hcys in the plasma. Therefore, we developed and validate an alternative method that uses the direct injection of treated plasma (reduced and precipitated). This same method was evaluated in terms of selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), matrix effect and precision (intra-and inter-day) and applied to the determination of Hcys in a group composed by patients presenting augmented CVD risk. Good results in terms of selectivity and linearity (R2> 0.9968) were obtained, being the values of LOD and LOQ 0.007 and 0.21 mol / L, respectively. The intra-day precision (1.23-3.32%), inter-day precision (5.43-6.99%) and the recovery rate (82.5 to 93.1%) of this method were satisfactory. The matrix effect (>120%) was, however, higher than we were waiting for. Using this methodology it was possible to determine the amount of Hcys in real plasma samples from individuals presenting augmented CVD risk. Regarding the methodology developed for vitamins, despite the optimization of the extraction technique and the chromatographic conditions, it was found that the levels usually present in plasma are far below the sensitivity we obtained. Therefore, further optimizations of the methodology developed are needed. As conclusion, part of the objectives of this study was achieved with the development of a quick, simple and cheaper method for the quantification of Hcys.
Resumo:
Tuberculosis is a serious disease, but curable in practically 100% of new cases, since complied the principles of modern chemotherapy. Isoniazid (ISN), Rifampicin (RIF), Pyrazinamide (PYR) and Chloride Ethambutol (ETA) are considered first line drugs in the treatment of tuberculosis, by combining the highest level of efficiency with acceptable degree of toxicity. Concerning USP 33 - NF28 (2010) the chromatography analysis to 3 of 4 drugs (ISN, PYR and RIF) last in average 15 minutes and 10 minutes more to obtain the 4th drug (ETA) using a column and mobile phase mixture different, becoming its industrial application unfavorable. Thus, many studies have being carried out to minimize this problem. An alternative would use the UFLC, which is based with the same principles of HPLC, however it uses stationary phases with particles smaller than 2 μm. Therefore, this study goals to develop and validate new analytical methods to determine simultaneously the drugs by HPLC/DAD and UFLC/DAD. For this, a analytical screening was carried out, which verified that is necessary a gradient of mobile phase system A (acetate buffer:methanol 94:6 v/v) and B (acetate buffer:acetonitrile 55:45 v/v). Furthermore, to the development and optimization of the method in HPLC and UFLC, with achievement of the values of system suitability into the criteria limits required for both techniques, the validations have began. Standard solutions and tablets test solutions were prepared and injected into HPLC and UFLC, containing 0.008 mg/mL ISN, 0.043 mg/mL PYR, 0.030 mg.mL-1 ETA and 0.016 mg/mL RIF. The validation of analytical methods for HPLC and UFLC was carried out with the determination of specificity/selectivity, analytical curve, linearity, precision, limits of detection and quantification, accuracy and robustness. The methods were adequate for determination of 4 drugs separately without interfered with the others. Precise, due to the fact of the methods demonstrated since with the days variation, besides the repeatability, the values were into the level required by the regular agency. Linear (R> 0,99), once the methods were capable to demonstrate results directly proportional to the concentration of the analyte sample, within of specified range. Accurate, once the methods were capable to present values of variation coefficient and recovery percentage into the required limits (98 to 102%). The methods showed LOD and LOQ very low showing the high sensitivity of the methods for the four drugs. The robustness of the methods were evaluate, facing the temperature and flow changes, where they showed robustness just with the preview conditions established of temperature and flow, abrupt changes may influence with the results of methods
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
BackgroundDetection and quantification of hepatitis C virus (HCV) RNA is integral to diagnostic and therapeutic regimens. All molecular assays target the viral 5'-noncoding region (59-NCR), and all show genotype-dependent variation of sensitivities and viral load results. Non-western HCV genotypes have been under-represented in evaluation studies. An alternative diagnostic target region within the HCV genome could facilitate a new generation of assays.Methods and FindingsIn this study we determined by de novo sequencing that the 3'-X-tail element, characterized significantly later than the rest of the genome, is highly conserved across genotypes. To prove its clinical utility as a molecular diagnostic target, a prototype qualitative and quantitative test was developed and evaluated multicentrically on a large and complete panel of 725 clinical plasma samples, covering HCV genotypes 1-6, from four continents (Germany, UK, Brazil, South Africa, Singapore). To our knowledge, this is the most diversified and comprehensive panel of clinical and genotype specimens used in HCV nucleic acid testing (NAT) validation to date. The lower limit of detection (LOD) was 18.4 IU/ml (95% confidence interval, 15.3-24.1 IU/ml), suggesting applicability in donor blood screening. The upper LOD exceeded 10(-9) IU/ml, facilitating viral load monitoring within a wide dynamic range. In 598 genotyped samples, quantified by Bayer VERSANT 3.0 branched DNA (bDNA), X-tail-based viral loads were highly concordant with bDNA for all genotypes. Correlation coefficients between bDNA and X-tail NAT, for genotypes 1-6, were: 0.92, 0.85, 0.95, 0.91, 0.95, and 0.96, respectively; X-tail-based viral loads deviated by more than 0.5 log10 from 5'-NCR-based viral loads in only 12% of samples (maximum deviation, 0.85 log10). The successful introduction of X-tail NAT in a Brazilian laboratory confirmed the practical stability and robustness of the X-tail-based protocol. The assay was implemented at low reaction costs (US$8.70 per sample), short turnover times (2.5 h for up to 96 samples), and without technical difficulties.ConclusionThis study indicates a way to fundamentally improve HCV viral load monitoring and infection screening. Our prototype assay can serve as a template for a new generation of viral load assays. Additionally, to our knowledge this study provides the first open protocol to permit industry-grade HCV detection and quantification in resource-limited settings.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The pharmacokinetics of enrofloxacin (ENRO), a fluoroquinolone antimicrobial agent, was studied in male broiler chickens (Cobb) after single oral administration of 10 mg of ENRO/kg b.w. A high-performance liquid chromatography-photodiode array detector (DAD) (HPLC-DAD) method was developed and validated and used for quantitation of ENRO and its major metabolite ciprofloxacin in plasma. The HPLC analyses were carried out using a cationic-octadecyl mixed column and 0.05 mol/L phosphate buffer (pH 2.5)/acetonitrile as mobile phase. The sample preparation of plasma consisted of the precipitation of proteins followed by solid phase extraction on cationic-octadecyl mixed cartridges. The method was validated considering linear range, linearity, selectivity, sensitivity, limit of detection (LOD), limit of quantitation (LOQ), intra- and inter-day precisions and accuracy. The LOD and LOQ for both fluoroquinolones were 60 and 200 ng/mL for plasma. The plasma concentration vs. time graph was characteristic of a two-compartment open model. The maximal plasma concentration of 1.5 +/- 0.2 mg/mL was achieved at 9 +/- 2 h. The elimination half-life and the mean residence time of ENRO were 1.5 +/- 0.2 and 15.64 h, respectively. The area under the concentration-time curve was calculated as 35 +/- 4 mg(.)h/mL.
Resumo:
This paper presents a simple, fast and sensitive method to determine selenium in samples of feces and of fish feed by graphite furnace atomic absorption spectrometry (GFAAS) through the direct introduction of slurries of the samples into the spectrometer's graphite tube. The limits of detection (LOD) and quantification (LOQ calculated for 20 readings of the blank of the standard slurries (0.50% m/v of feces or feed devoid of selenium) were 0.31 mu g 1(-1) and 1.03 mu g 1(-1), respectively, for the standard feces slurries and 0.35 mu g 1(-1) and 1.16 mu g 1(-1), respectively, for the standard feed slurries. The proposed method was applied in studies of bioavailability of selenium in different fish feeds and the results proved consistent with that obtained from samples mineralized by acid digestion using the microwave oven. (C) 2007 Elsevier Ltd. All rights reserved.