LC Evaluation of In Vitro Release of AZT from Microemulsions


Autoria(s): Carvalho, Flavia Chiva; Barbi, Mariana da Silva; Gremião, Maria Palmira Daflon
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

20/05/2014

20/05/2014

01/06/2009

Resumo

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

A reversed phase LC method was developed and validated to analyze the in vitro release of AZT from microemulsions. A mobile phase of acetonitrile:water (15:85) was used. The method validation showed good selectivity and linearity (r = 0.9993) for sample concentrations ranging from 0.6 to 100.0 mu g mL(-1). The RSD values (0.7-4.3%) and percentage recovery (88.1-109.8%) were within acceptable limits. The limit of detection (LOD) and limit of quantitation (LOQ) were found to be 0.012 and 0.041 mu g mL(-1). Quantitative analysis of the values obtained in the drug release assay indicates that the microemulsions used promote sustained release of AZT, which follows a Fickian diffusion mechanism.

Formato

207-211

Identificador

http://dx.doi.org/10.1365/s10337-009-1015-1

Chromatographia. Wiesbaden: Vieweg, v. 69, p. 207-211, 2009.

0009-5893

http://hdl.handle.net/11449/7849

10.1365/s10337-009-1015-1

WOS:000267330400016

Idioma(s)

eng

Publicador

Vieweg

Relação

Chromatographia

Direitos

closedAccess

Palavras-Chave #Column liquid chromatography #In vitro drug release #Drug delivery system #Zidovudine
Tipo

info:eu-repo/semantics/article