916 resultados para Kinematic


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the accuracy and reliability of observational kinematic gait assessments performed via a low-bandwidth Internet link (118 kbit/s) and a higher-speed Internet link (128 kbit/s). Twenty-four subjects were randomized to either bandwidth group. Gait was assessed with the Gait Assessment Rating Scale (GARS) in the traditional manner, which is from video-recordings, and with repeated measurements via the online method. Online assessment was found to provide as accurate a measure of gait performance as the traditional assessment (limits of agreement

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Primary objective: To investigate jaw movements in children following traumatic brain injury (TBI) during speech using electromagnetic articulography (EMA). Methods and procedures: Jaw movements of two non-dysarthric children ( aged 12.75 and 13.08 years) who had sustained a TBI were recorded using the AG-100 EMA system (Carstens Medizineletronik) during word-initial consonant productions. Mean quantitative kinematic parameters and coefficient of variation ( variability) values were calculated and individually compared to the mean values obtained by a group of six control children ( mean age 12.57 years, SD 1.52). Main outcomes and results: The two children with TBI exhibited word-initial consonant jaw movement durations that were comparable to the control children, with sub-clinical reductions in speed being offset by reduced distances. Differences were observed between the two children in jaw kinematic variability, with one child exhibiting increased variability, while the other child demonstrated reduced or comparable variability compared to the control group. Conclusions: Possible sub-clinical impairments of jaw movement for speech were exhibited by two children who had sustained a TBI, providing insight into the consequences of TBI on speech motor control development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acknowledgments This work was carried out with support from CNPq (Conselho Nacional de Desenvolvimento Científico e Tecnológico) – Brazil, BG-Brazil and the University of Aberdeen. We would like to thank the following geologists for their support, camaraderie and countless hours of fieldwork: Claus Fallgatter, Victoria Valdez, Carla Puigdomenech, Guilherme Bozetti, Roberto Noll Filho and Arthur Giovannini, and we thank Lorena Moscardelli and an anonymous reviewer, whose constructive comments helped to improve the manuscript.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability to capture human motion allows researchers to evaluate an individual’s gait. Gait can be measured in different ways, from camera-based systems to Magnetic and Inertial Measurement Units (MIMU). The former uses cameras to track positional information of photo-reflective markers, while the latter uses accelerometers, gyroscopes, and magnetometers to measure segment orientation. Both systems can be used to measure joint kinematics, but the results vary because of their differences in anatomical calibrations. The objective of this thesis was to study potential solutions for reducing joint angle discrepancies between MIMU and camera-based systems. The first study worked to correct the anatomical frame differences between MIMU and camera-based systems via the joint angles of both systems. This study looked at full lower body correction versus correcting a single joint. Single joint correction showed slightly better alignment of both systems, but does not take into account that body segments are generally affected by more than one joint. The second study explores the possibility of anatomical landmarking using a single camera and a pointer apparatus. Results showed anatomical landmark position could be determined using a single camera, as the anatomical landmarks found from this study and a camera-based system showed similar results. This thesis worked on providing a novel way for obtaining anatomical landmarks with a single point-and-shoot camera, as well aligning anatomical frames between MIMUs and camera-based systems using joint angles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinical optical motion capture allows us to obtain kinematic and kinetic outcome measures that aid clinicians in diagnosing and treating different pathologies affecting healthy gait. The long term aim for gait centres is for subject-specific analyses that can predict, prevent, or reverse the effects of pathologies through gait retraining. To track the body, anatomical segment coordinate systems are commonly created by applying markers to the surface of the skin over specific, bony anatomy that is manually palpated. The location and placement of these markers is subjective and precision errors of up to 25mm have been reported [1]. Additionally, the selection of which anatomical landmarks to use in segment models can result in large angular differences; for example angular differences in the trunk can range up to 53o for the same motion depending on marker placement [2]. These errors can result in erroneous kinematic outcomes that either diminish or increase the apparent effects of a treatment or pathology compared to healthy data. Our goal was to improve the accuracy and precision of optical motion capture outcome measures. This thesis describes two separate studies. In the first study we aimed to establish an approach that would allow us to independently quantify the error among trunk models. Using this approach we determined if there was a best model to accurately track trunk motion. In the second study we designed a device to improve precision for test, re-test protocols that would also reduce the set-up time for motion capture experiments. Our method to compare a kinematically derived centre of mass velocity to one that was derived kinetically was successful in quantifying error among trunk models. Our findings indicate that models that use lateral shoulder markers as well as limit the translational degrees of freedom of the trunk through shared pelvic markers result in the least amount of error for the tasks we studied. We also successfully reduced intra- and inter-operator anatomical marker placement errors using a marker alignment device. The improved accuracy and precision resulting from the methods established in this thesis may lead to increased sensitivity to changes in kinematics, and ultimately result in more consistent treatment outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of the Design by Analysis (DBA) route is a modern trend in pressure vessel and piping international codes in mechanical engineering. However, to apply the DBA to structures under variable mechanical and thermal loads, it is necessary to assure that the plastic collapse modes, alternate plasticity and incremental collapse (with instantaneous plastic collapse as a particular case), be precluded. The tool available to achieve this target is the shakedown theory. Unfortunately, the practical numerical applications of the shakedown theory result in very large nonlinear optimization problems with nonlinear constraints. Precise, robust and efficient algorithms and finite elements to solve this problem in finite dimension has been a more recent achievements. However, to solve real problems in an industrial level, it is necessary also to consider more realistic material properties as well as to accomplish 3D analysis. Limited kinematic hardening, is a typical property of the usual steels and it should be considered in realistic applications. In this paper, a new finite element with internal thermodynamical variables to model kinematic hardening materials is developed and tested. This element is a mixed ten nodes tetrahedron and through an appropriate change of variables is possible to embed it in a shakedown analysis software developed by Zouain and co-workers for elastic ideally-plastic materials, and then use it to perform 3D shakedown analysis in cases with limited kinematic hardening materials

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of the Design by Analysis concept is a trend in modern pressure vessel and piping calculations. DBA flexibility allow us to deal with unexpected configurations detected at in-service inspections. It is also important, in life extension calculations, when deviations of the original standard hypotesis adopted initially in Design by Formula, can happen. To apply the DBA to structures under variable mechanic and thermal loads, it is necessary that, alternate plasticity and incremental collapse (with instantaneous plastic collapse as a particular case), be precluded. These are two basic failure modes considered by ASME or European Standards in DBA. The shakedown theory is the tool available to achieve this goal. In order to apply it, is necessary only the range of the variable loads and the material properties. Precise, robust and efficient algorithms to solve the very large nonlinear optimization problems generated in numerical applications of the shakedown theory is a recent achievement. Zouain and co-workers developed one of these algorithms for elastic ideally-plastic materials. But, it is necessary to consider more realistic material properties in real practical applications. This paper shows an enhancement of this algorithm to dealing with limited kinematic hardening, a typical property of the usual steels. This is done using internal thermodynamic variables. A discrete algorithm is obtained using a plane stress, mixed finite element, with internal variable. An example, a beam encased in an end, under constant axial force and variable moment is presented to show the importance of considering the limited kinematic hardening in a shakedown analysis.