917 resultados para Impulsive Loading


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of different air-particle abrasion protocols on the biaxial flexural strength and structural stability of zirconia ceramics. Zirconia ceramic specimens (ISO 6872) (Lava, 3M ESPE) were obtained (N=336). The specimens (N=118, n=20 per group) were randomly assigned to one of the air-abrasion protocols: Gr1: Control (as-sintered); Gr2: 50 μm Al2O3 (2.5 bar); Gr3: 50 μm Al2O3 (3.5 bar); Gr4: 110 μm Al2O3(2.5 bar); Gr5: 110 μm Al2O3 (3.5 bar); Gr6: 30 μm SiO2 (2.5 bar) (CoJet); Gr7: 30 μm SiO2(3.5 bar); Gr8: 110 μm SiO2 (2.5 bar) (Rocatec Plus); and Gr9: 110 μm SiO2 (3.5 bar) (duration: 20 s, distance: 10 mm). While half of the specimens were tested immediately, the other half was subjected to cyclic loading in water (100,000 cycles; 50 N, 4 Hz, 37 °°C) prior to biaxial flexural strength test (ISO 6872). Phase transformation (t→m), relative amount of transformed monoclinic zirconia (FM), transformed zone depth (TZD) and surface roughness were measured. Particle type (p=0.2746), pressure (p=0.5084) and cyclic loading (p=0.1610) did not influence the flexural strength. Except for the air-abraded group with 110 μm Al2O3 at 3.5 bar, all air-abrasion protocols increased the biaxial flexural strength (MPa) (Controlnon-aged: 1030±153, Controlaged: 1138±138; Experimentalnon-aged: 1307±184-1554±124; Experimentalaged: 1308±118-1451±135) in both non-aged and aged conditions, respectively. Surface roughness (Ra) was the highest with 110 μm Al2O3(0.84 μm. FM values ranged from 0% to 27.21%, higher value for the Rocatec Plus (110 μm SiO2) and 110 μm Al2O3 groups at 3.5 bar pressure. TZD ranged between 0 and 1.43 μm, with the highest values for Rocatec Plus and 110 μm Al2O3 groups at 3.5 bar pressure. © 2013 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho descreve detalhadamente o efeito da quantidade de cério na estrutura e morfologia da zeólita NH4USY. Ce-USY (2-25% m/m de CeO2) foi obtido por impregnação úmida de CeCl3 seguida de calcinação a 550ºC por 8 h. Em quantidades baixas (2-10%), foi observado que as espécies de cério encontram-se nas posições de troca iônica na rede, enquanto em maiores teores (15-25%) pequenos agregados formaram-se na superfície da HUSY. Difratometria de raios X (XRD) mostrou apenas reflexões relacionadas à HUSY, confirmando a alta dispersão das espécies de cério, porém as análises por espectroscopia Raman com transformada de Fourier (FT-Raman) detectaram CeOx para os materiais acima de 10%. A reação do CeCl3 com NH4USY produziu NH4Cl, o qual se decompõe em HCl, ocasionando a desaluminização da rede. Os materiais apresentaram um aumento da razão Lewis/Brønsted com o aumento da quantidade de cério, devido a interação do excesso de cério com os grupos OH da USY e consequente formação de espécies CeOx.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXTO:A melhor dose para o início do tratamento anticoagulante com varfarina vem sendo debatida nos últimos dez anos. Em nosso meio, não observamos nenhum estudo comparativo quanto a estas características.OBJETIVO:Comparar segurança e eficácia de dois esquemas de dosagem inicial de varfarina para tratamento anticoagulante.MÉTODOS:Foram estudados prospectivamente 110 pacientes de ambos os sexos, consecutivos, com indicação de anticoagulação por tromboembolismo venoso ou arterial. Durante os três primeiros dias de tratamento, estes pacientes receberam doses adequadas de heparina (RT - razão dos tempos - alvo entre 1,5 e 2,5) e 5 mg de varfarina, cuja dose foi reajustada a partir do quarto dia pelo Razão Normatizada Internacional - RNI (alvo entre 2 e 3). Esse grupo foi comparado com série histórica de 110 pacientes que receberam 10 mg nos dois primeiros dias, 5 mg a partir do terceiro dia, com ajuste posterior de dose baseado no RNI. Os desfechos foram: recorrência do tromboembolismo, sangramentos e tempo para alcançar níveis terapêuticos.RESULTADOS:A eficácia, a segurança e o tempo de internação foram similares entre os grupos. O grupo que recebeu 10 mg atingiu níveis terapêuticos mais precocemente (média de 4,5 dias × 5,8 dias), sendo as doses na alta menores e os níveis terapêuticos mais adequados na primeira visita de retorno.CONCLUSÃO:O esquema de dosagem de 10 mg proporcionou menor tempo para alcançar nível terapêutico, com menores doses de varfarina na alta e RNI mais adequado no retorno.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Moderate and controlled loading environments support or enhance osteogenesis, and, consequently, a high degree of bone-to-implant contact can be acquired. This is because when osteoprogenitor cells are exposed to limited physical deformation, their differentiation into osteoblasts is enhanced. Then, some range of microstrain is considered advantageous for bone ingrowth and osseointegration. The primary stability has been considered one of the main clinical means of controlling micromotion between the implant and the forming interfacial tissue, which helps to establish the proper mechanical environment for osteogenesis. Based on the biological aspects of immediate loading (IL), the objective of this study is to present a clinical case of maxillary arch rehabilitation using immediate loading with implant-supported fixed restoration after bone graft. Ten dental implants were placed in the maxilla 6 months after the autogenous bone graft, removed from the mandible (bilateral oblique line and chin), followed by the installation of an immediate-load fixed cross-arch implant-supported restoration because primary stability was reached for 8 implants. In addition, instructions about masticatory function and how it is related to interfacial micromotion were addressed and emphasized to the patient. The reasons for the IL were further avoidance of an interim healing phase, a potential reduction in the number of clinical interventions for the patient, and aesthetic reasons. After monitoring the rehabilitation for 8 years, the authors can conclude that maxillary IL can be performed followed by a well-established treatment planning based on computed tomography, providing immediate esthetics and function to the patient even when autogenous bone graft was previously performed in the maxilla.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current study used strain gauge analysis to perform an in vitro evaluation of the effect of axial and non-axial loading on implant-supported fixed partial prostheses, varying the implant placement configurations and the loading points. Three internal hexagon implants were embedded in the center of each polyurethane block with in-line and offset placements. Microunit abutments were connected to the implants using a torque of 20 N.cm, and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 10). Four strain gauges (SGs) were bonded onto the surfaces of the blocks, tangentially to the implants: SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments using a 10-N.cm torque, and axial and non-axial loads of 30 kg were applied at 5 predetermined points. The data obtained from the strain gauge analyses were analyzed statistically through the repeated measures analysis of variance and the Tukey test, with a conventional level of significance of P < 0.05. The results showed a statistically significant difference for the loading point (P = 0.0001), with point E (nonaxial) generating the highest microstrain (327.67 mu epsilon) and point A (axial) generating the smallest microstrain (208.93 mu epsilon). No statistically significant difference was found for implant placement configuration (P = 0.856). It was concluded that the offset implant placement did not reduce the magnitude of microstrain around the implants under axial and non-axial loading conditions, although loading location did influence this magnitude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The article investigates complex impulsive systems in which the so-called controlling systems jumps effect emerges. In particular, this research includes the correctness of the solution to the impulsive control system and approximation lemmas. A 3D model example is provided which illustrates the relevance of the considered approach to the study of complex impulsive systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the influence of different insertion torques on healing of implants loaded immediately or left unloaded.Material and methods: In six Labrador dogs, all mandibular premolars and molars were extracted. After 4 months of healing, flaps were elevated, and two implant sites were prepared at each side of the mandible. The distal sites were prepared conventionally while the mesial sites were underprepared by 0.3 mm. As a consequence, different final insertion torques of about 30 Ncm at the distal and >70 Ncm at the mesial sites were recorded. Healing abutments were applied to the left and transmucosal abutments to the right side. Flaps were sutured, crown preparation of the upper right second and third premolars was performed, and impressions were taken. Within 24 h, crowns were cemented both to implants and teeth in the right side of the mouth. After 4 months, the animals were sacrificed and ground sections obtained for histological evaluation.Results: A higher buccal bony crestal resorption and a more apical position of the coronal level of osseointegration were found at the loaded compared with the unloaded sites. MBIC% and percentages of peri-implant mineralized tissue (MB%) were higher at the loaded compared with the unloaded sites. Moreover, a higher MBIC% was found at the lower compared with the higher final insertion torque.Conclusions: Immediate loading does not seem to have a negative effect on osseointegration. High torque values for the immediate loading procedures were not necessary. Probably, low torque values, were sufficient to obtain primary stability and hence may provide better osseointegration than high torque value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this paper is to present the application of a three-phase harmonic propagation analysis time-domain tool, using the Norton model to approach the modeling of non-linear loads, making the harmonics currents flow more appropriate to the operation analysis and to the influence of mitigation elements analysis. This software makes it possible to obtain results closer to the real distribution network, considering voltages unbalances, currents imbalances and the application of mitigation elements for harmonic distortions. In this scenario, a real case study with network data and equipments connected to the network will be presented, as well as the modeling of non-linear loads based on real data obtained from some PCCs (Points of Common Coupling) of interests for a distribution company.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)