889 resultados para Impedance Measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have compared the use of bioelectrical impedance analysis (BIA) with anthropometry for the prediction of changes in total body potassium (TBK) in a group (n = 31) of children with cystic fibrosis. Linear regression analysis showed that TBK was highly correlated (r > 0.93) with height(2)/impedance, weight, height, and fat-free mass (FFM) estimated from skin-fold measurements. Changes in TBK were also correlated, but less well, with changes in height(2)/impedance, weight, height, and FFM (r = 0.69, 0.59, 0.44, and 0.40, respectively). The children were divided into two groups: those who had normal accretion of TBK (> 5%/y) and those who had suboptimal accretion of TBK (< 5%/y). Analysis of variance showed that the significant difference in the change in TBK between the groups was detectable by concomitant changes in impedance and weight but not by changes in height, FFM, or weight and height Z scores. The results of this study suggest that serial BIA measures may be useful as a predictor of progressive undernutrition and poor growth in children with cystic fibrosis. (C) Elsevier Science Inc. 1997.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to confirm that the radiation doses received by attendants who manually restrain infants during fluoroscopic procedures are low. Doses to the hands and neck of three radiologists and three nurses performing or assisting at all the fluoroscopic procedures in a children's hospital were measured for 1 month using thermoluminescent dosemeters. All fluoroscopy on children at this hospital is performed without an antiscatter grid. Total doses for the neck ranged from 20 to 50 mu Sv per week and for hands from 40 to 210 mu Sv per week. These doses were shared by the three radiologists and the three nurses. Individual doses received per staff member are very small when compared with the doses received by interventional radiology staff. Doses received by staff in this study were of the order of 5% of the limit advised by the National Health and Medical Research Council of Australia (NHMRC) for radiation workers. Nurses received larger doses than radiologists and steps will be taken to reduce this dose further.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analysis of a major multi-site epidemiologic study of heart disease has required estimation of the pairwise correlation of several measurements across sub-populations. Because the measurements from each sub-population were subject to sampling variability, the Pearson product moment estimator of these correlations produces biased estimates. This paper proposes a model that takes into account within and between sub-population variation, provides algorithms for obtaining maximum likelihood estimates of these correlations and discusses several approaches for obtaining interval estimates. (C) 1997 by John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background & aims: Severe obesity imposes physical limitations to body composition assessment. Our aim was to compare body fat (BF) estimations of severely obese patients obtained by bioelectrical impedance (BIA) and air displacement plethysmography (ADP) for development of new equations for BF prediction. Methods: Severely obese subjects (83 female/36 mate, mean age = 41.6 +/- 11.6 years) had BF estimated by BIA and ADP. The agreement of the data was evaluated using Bland-Altman`s graphic and concordance correlation coefficient (CCC). A multivariate regression analysis was performed to develop and validate new predictive equations. Results: BF estimations from BIA (64.8 +/- 15 kg) and ADP (65.6 +/- 16.4 kg) did not differ (p > 0.05, with good accuracy, precision, and CCC), but the Bland- Altman graphic showed a wide Limit of agreement (- 10.4; 8.8). The standard BIA equation overestimated BF in women (-1.3 kg) and underestimated BF in men (5.6 kg; p < 0.05). Two BF new predictive equations were generated after BIA measurement, which predicted BF with higher accuracy, precision, CCC, and limits of agreement than the standard BIA equation. Conclusions: Standard BIA equations were inadequate for estimating BF in severely obese patients. Equations developed especially for this population provide more accurate BF assessment. (C) 2008 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conclusion. The study shows that there are differences in the measurement of the action potentials with and without the stylet in the Nucleus Freedom Contour Advance that are higher in the apex than in the base of the cochlea. Objectives. To determine if there are differences in the intraoperative impedances and in the neural response telemetry threshold values in the Nucleus Freedom Contour Advance before and after stylet removal. Subjects and methods. This was a prospective clinical study. Intraoperative impedances and neural response telemetry in users of the Freedom Contour Advance Cochlear Implant were measured before and after stylet removal. Results. There was a significant reduction in the impedance values of an average 1.5 k Omega +/- 2.3 in common ground mode and 1.3 k Omega +/- 2.3 for all monopolar modes after the stylet removal (p < 0.001). When analyzing the apical, medium, and basal electrodes, there was a statistically significant reduction in the neural response thresholds after stylet removal only in the apical electrodes (p = 0.001).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To use 3-dimensional sonography (3DUS) to measure contralateral lung volume and evaluate the potential of this measurement to predict neonatal outcome in isolated congenital diaphragmatic hernia (CDH). Methods. Between January 2002 and December 2004, the contralateral lung volumes of 39 fetuses with isolated CDH were measured via 3DUS using rotational multiplanar imaging. The observed/expected contralateral fetal lung volume ratios (o/eContFLVR) were compared with the lung/head ratio (LHR), observed/expected total fetal lung volume ratio (o/e-TotFLVR), and postnatal outcome. Results. Contralateral lung volumes are less reduced than total lung volumes in CDH. The bias and precision of 3DUS in estimating contralateral lung volumes were 0.99 cm(3) and 1.11 cm(3), respectively, with absolute limits of agreement ranging from -1.19 cm(3) to + 3.17 cm(3). The o/e-ContFLVR was significantly lower in neonatal death cases (median, 0.49 cm(3); range, 0.22-0.99 cm(3)) than in survival cases (median, 0.58 cm(3); range, 0.42-0.92 cm(3) [p < 0.011). Overall accuracy of the o/e-ContFLVR, o/e-TotFLVR, and LHR in predicting neonatal death were 67.7% (21/31), 80.7% (25/31), and 77.4% (24/31), respectively. Conclusion. Although o/e-ContFLVR can be precisely measured with 3DUS and can be used to predict neonatal death in CDH, it is less accurate than LHR and o/e-TotFLVR for that purpose. (C) 2007 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The magnitude Of functional impairment that may indicate the threshold between MCI and incipient Alzheimer`s disease (AD) has not been clearly defined. The objective was to examine the pattern of functional impairment in the continuum MCI-AD. Eighty-nine older adults (32 cognitively unimpaired, 31 MCI, and 26 AD patients) were examined with the Brazilian version of the Direct Assessment of Functional Status (DAFS-BR) at a University-based memory clinic. MCI patients were sub-divided according to the progression to AD upon follow-up, and had baseline cognitive, functional and biological variables analyzed. MCI patients displayed mild deficits in functional abilities, with intermediate scores as compared to controls and AD. The DAFS-BR items that differentiated MCI from controls involved the ability to deal with finances and shopping skills. At baseline, scores obtained by MCI patients who converted to AD were not significantly different from scores of nonconverters. The magnitude of functional deficits was associated with AD-like pathological findings in the CSF. In conclusion, MCI patients present with early functional changes in complex, instrumental abilities that require the integrity of memory and executive functions. The objective measurement of the functional state may help identify older adults with increased risk of developing dementia in the MCI-AD continuum. (JINS, 2010, 16, 297-305.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Air pollution is associated with morbidity and mortality induced by respiratory diseases. However, the mechanisms therein involved are not yet fully clarified. Thus, we tested the hypothesis that a single acute exposure to low doses of fine particulate matter (PM2.5) may induce functional and histological lung changes and unchain inflammatory and oxidative stress processes. PM2.5 was collected from the urban area of Sao Paulo city during 24 h and underwent analysis for elements and polycyclic aromatic hydrocarbon contents. Forty-six male BALB/c mice received intranasal instillation of 30 mu L of saline (CTRL) or PM2.5 at 5 or 15 mu g in 30 mu L of saline (P5 and P15, respectively). Twenty-four hours later, lung mechanics were determined. Lungs were then prepared for histological and biochemical analysis. P15 group showed significantly increased lung impedance and alveolar collapse, as well as lung tissue inflammation, oxidative stress and damage. P5 presented values between CTRL and P15: higher mechanical impedance and inflammation than CTRL, but lower inflammation and oxidative stress than P15. In conclusion, acute exposure to low doses of fine PM induced lung inflammation, oxidative stress and worsened lung impedance and histology in a dose-dependent pattern in mice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The treatment of microcystin-LR (MCYST-LR)-induced lung inflammation has never been reported Hence. LASSBio 596, an anti-Inflammatory drug candidate, designed as symbiotic agent that modulates TNF-alpha levels and inhibits phosphodiesterase types 4 and 5, or dexamethasone were tested in this condition Swiss mice were intraperitoneally (i p) injected with 60 mu l of saline (CTRL) or a sub-lethal dose of MCYST-LR (40 mu g/kg). 6 h later they were treated (i p.) with saline (TOX), LASSB10 596 (10 mg/kg, L596), or dexamethasone (1 mg/kg, 0.1 mL, DEXA). 8 h after MCYST-LR injection, pulmonary mechanics were determined, and lungs and livers prepared for histopathology, biochemical analysis and quantification of MCYST-LR. TOX showed significantly higher lung impedance than CTRL and L596, which were similar. DEXA could only partially block the mechanical alterations. In both TOX and DEXA alveolar collapse and inflammatory cell influx were higher than in CTRL and L596, being LASSB10 596 more effective than dexamethasone. TOX showed oxidative stress that was not present in an and L596, while DEXA was partially efficient. MCYST-LR was detected in the livers of all mice receiving MCYST-LR and no recovery was apparent In conclusion, LASSBio 596 was more efficient than dexamethasone in reducing the pulmonary functional impairment induced by MCYST-LR. (C) 2010 Elsevier Ltd. All rights reserved

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Several attempts to determine the transit time of a high dose rate (HDR) brachytherapy unit have been reported in the literature with controversial results. The determination of the source speed is necessary to accurately calculate the transient dose in brachytherapy treatments. In these studies, only the average speed of the source was measured as a parameter for transit dose calculation, which does not account for the realistic movement of the source, and is therefore inaccurate for numerical simulations. The purpose of this work is to report the implementation and technical design of an optical fiber based detector to directly measure the instantaneous speed profile of a (192)Ir source in a Nucletron HDR brachytherapy unit. Methods: To accomplish this task, we have developed a setup that uses the Cerenkov light induced in optical fibers as a detection signal for the radiation source moving inside the HDR catheter. As the (192)Ir source travels between two optical fibers with known distance, the threshold of the induced signals are used to extract the transit time and thus the velocity. The high resolution of the detector enables the measurement of the transit time at short separation distance of the fibers, providing the instantaneous speed. Results: Accurate and high resolution speed profiles of the 192Ir radiation source traveling from the safe to the end of the catheter and between dwell positions are presented. The maximum and minimum velocities of the source were found to be 52.0 +/- 1.0 and 17.3 +/- 1:2 cm/s. The authors demonstrate that the radiation source follows a uniformly accelerated linear motion with acceleration of vertical bar a vertical bar = 113 cm/s(2). In addition, the authors compare the average speed measured using the optical fiber detector to those obtained in the literature, showing deviation up to 265%. Conclusions: To the best of the authors` knowledge, the authors directly measured for the first time the instantaneous speed profile of a radiation source in a HDR brachytherapy unit traveling from the unit safe to the end of the catheter and between interdwell distances. The method is feasible and accurate to implement on quality assurance tests and provides a unique database for efficient computational simulations of the transient dose. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3483780]

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.