983 resultados para IMMEDIATE IMPLANT
Resumo:
P>The aim of this study was to validate an original portable device to measure attachment retention of implant overdentures both in the lab and in clinical settings. The device was built with a digital force measurement gauge (Imada) secured to a vertical wheel stand associated with a customized support to hold and position the denture in adjustable angulations. Sixteen matrix and patrix cylindrical stud attachments (Locator (R)) were randomly assigned as in vitro test specimens. Attachment abutments were secured in an implant analogue hung to the digital force gauge or to the load cell of a traction machine used as the gold standard (Instron Universal Testing Machine). Matrices were secured in a denture duplicate attached to the customized support, permitting reproducibility of their position on both pulling devices. Attachment retention in the axial direction was evaluated by measuring maximum dislodging force or peak load during five consecutive linear dislodgments of each attachment on both devices. After a wear simulation, retention was measured again at several time periods. The peak load measurements with the customized Imada device were similar to those obtained with the gold standard Instron machine. These findings suggest that the proposed portable device can provide accurate information on the retentive properties of attachment systems for removable dental prostheses.
Resumo:
Objectives Bacterial penetration along the implant-abutment interface as a consequence of abutment screw loosening has been reported in a number of recent studies. The aim of this in vitro study was to investigate the influence of repeated tightening of the abutment screw on leakage of Streptococcus mutans along the interface between implants and pre-machined abutments. Materials and methods Twenty pre-machined abutments with a plastic sleeve were used. The abutment screws were tightened to 32 N cm in group 1 (n=10 - control) and to 32 N cm, loosened and re-tightened with the same torque twice in group 2 (n=10). The assemblies were completely immersed in 5 ml of Tryptic Soy Broth medium inoculated with S. mutans and incubated for 14 days. After this period, contamination of the implant internal threaded chamber was evaluated using the DNA Checkerboard method. Results Microorganisms were found on the internal surfaces of both groups evaluated. However, bacterial counts in group 2 were significantly higher than that in the control group (P < 0.05). Conclusion These results suggest that bacterial leakage between implants and abutments occurs even under unloaded conditions and at a higher intensity when the abutment screw is tightened and loosened repeatedly. To cite this article:do Nascimento C, Pedrazzi V, Kirsten Miani P, Daher Moreira L, de Albuquerque Junior RF. Influence of repeated screw tightening on bacterial leakage along the implant-abutment interface.Clin. Oral Impl. Res. 20, 2009; 1394-1397.doi: 10.1111/j.1600-0501.2009.01769.x.
Resumo:
No Abstract
Resumo:
Spheres of different types of material are used for the replacement of lost volume after removal of the eye bulb or its content to prevent contraction of the orbital cavity. The aim of this study was to evaluate the scope of polymethylmethacrylate (PMMA) used as intraocular implant in eviscerated rabbit eye. Twelve New Zealand rabbits underwent unilateral evisceration of the left eye, with subsequent implantation of PMMA sphere 12 mm in diameter. Clinical evaluation was performed daily during the first 15 days after surgery and every 15 days until the end of the study period (180 days). For the histopathological analysis, three animals per trial underwent enucleation at 15, 45, 90 and 180 days after evisceration. There was no wound dehiscence, signs of infection or implant extrusion in any animal throughout the study period. Histological examination revealed the formation of fibrovascular tissue around the implants. The PMMA behaved as inert and non-integrable.
Resumo:
Background: Several studies link the seamless fit of implant-supported prosthesis with the accuracy of the dental impression technique obtained during acquisition. In addition, factors such as implant angulation and coping shape contribute to implant misfit. Purpose: The aim of this study was to identify the most accurate impression technique and factors affecting the impression accuracy. Material and Methods: A systematic review of peer-reviewed literature was conducted analyzing articles published between 2009 and 2013. The following search terms were used: implant impression, impression accuracy, and implant misfit.A total of 417 articles were identified; 32 were selected for review. Results: All 32 selected studies refer to in vitro studies. Fourteen articles compare open and closed impression technique, 8 advocate the open technique, and 6 report similar results. Other 14 articles evaluate splinted and non-splinted techniques; all advocating the splinted technique. Polyether material usage was reported in nine; six studies tested vinyl polysiloxane and one study used irreversible hydrocolloid. Eight studies evaluated different copings designs. Intraoral optical devices were compared in four studies. Conclusions: The most accurate results were achieved with two configurations: (1) the optical intraoral system with powder and (2) the open technique with splinted squared transfer copings, using polyether as impression material.
Resumo:
The success of dental implant-supported prosthesis is directly linked to the accuracy obtained during implant’s pose estimation (position and orientation). Although traditional impression techniques and recent digital acquisition methods are acceptably accurate, a simultaneously fast, accurate and operator-independent methodology is still lacking. Hereto, an image-based framework is proposed to estimate the patient-specific implant’s pose using cone-beam computed tomography (CBCT) and prior knowledge of implanted model. The pose estimation is accomplished in a threestep approach: (1) a region-of-interest is extracted from the CBCT data using 2 operator-defined points at the implant’s main axis; (2) a simulated CBCT volume of the known implanted model is generated through Feldkamp-Davis-Kress reconstruction and coarsely aligned to the defined axis; and (3) a voxel-based rigid registration is performed to optimally align both patient and simulated CBCT data, extracting the implant’s pose from the optimal transformation. Three experiments were performed to evaluate the framework: (1) an in silico study using 48 implants distributed through 12 tridimensional synthetic mandibular models; (2) an in vitro study using an artificial mandible with 2 dental implants acquired with an i-CAT system; and (3) two clinical case studies. The results shown positional errors of 67±34μm and 108μm, and angular misfits of 0.15±0.08º and 1.4º, for experiment 1 and 2, respectively. Moreover, in experiment 3, visual assessment of clinical data results shown a coherent alignment of the reference implant. Overall, a novel image-based framework for implants’ pose estimation from CBCT data was proposed, showing accurate results in agreement with dental prosthesis modelling requirements.
Resumo:
DESIGN: A randomized controlled trial.OB JECTIVE: To investigate the immediate effects on pressure pain thresholds over latent trigger points (TrPs) in the masseter and temporalis muscles and active mouth opening following atlanto-occipital joint thrust manipulation or a soft tissue manual intervention targeted to the suboccipital muscles. BACKGROUND : Previous studies have described hypoalgesic effects of neck manipulative interventions over TrPs in the cervical musculature. There is a lack of studies analyzing these mechanisms over TrPs of muscles innervated by the trigeminal nerve. METHODS: One hundred twenty-two volunteers, 31 men and 91 women, between the ages of 18 and 30 years, with latent TrPs in the masseter muscle, were randomly divided into 3 groups: a manipulative group who received an atlanto-occipital joint thrust, a soft tissue group who received an inhibition technique over the suboccipital muscles, and a control group who did not receive an intervention. Pressure pain thresholds over latent TrPs in the masseter and temporalis muscles, and active mouth opening were assessed pretreatment and 2 minutes posttreatment by a blinded assessor. Mixed-model analyses of variance (ANOVA) were used to examine the effects of interventions on each outcome, with group as the between-subjects variable and time as the within-subjects variable. The primary analysis was the group-by-time interaction. RESULTS: The 2-by-3 mixed-model ANOVA revealed a significant group-by-time interaction for changes in pressure pain thresholds over masseter (P<.01) and temporalis (P =.003) muscle latent TrPs and also for active mouth opening (P<.001) in favor of the manipulative and soft tissue groups. Between-group effect sizes were small. CONCLUSIONS: The application of an atlanto-occipital thrust manipulation or soft tissue technique targeted to the suboccipital muscles led to an immediate increase in pressure pain thresholds over latent TrPs in the masseter and temporalis muscles and an increase in maximum active mouth opening. Nevertheless, the effects of both interventions were small and future studies are required to elucidate the clinical relevance of these changes. LEVEL OF EVIDENCE : Therapy, level 1b. J Orthop Sports Phys Ther 2010;40(5):310-317. doi:10.2519/jospt.2010.3257. KEYWORDSDS: cervical manipulation, muscle trigger points, neck, TMJ, upper cervical.
Resumo:
Background Mobilization with movement (MWM) has been shown to reduce pain, increase range of motion (ROM) and physical function in a range of different musculoskeletal disorders. Despite this evidence, there is a lack of studies evaluating the effects of MWM for hip osteoarthritis (OA). Objectives To determine the immediate effects of MWM on pain, ROM and functional performance in patients with hip OA. Design Randomized controlled trial with immediate follow-up. Method Forty consenting patients (mean age 78 ± 6 years; 54% female) satisfied the eligibility criteria. All participants completed the study. Two forms of MWM techniques (n = 20) or a simulated MWM (sham) (n = 20) were applied. Primary outcomes: pain recorded by numerical rating scale (NRS). Secondary outcomes: hip flexion and internal rotation ROM, and physical performance (timed up and go, sit to stand, and 40 m self placed walk test) were assessed before and after the intervention. Results For the MWM group, pain decreased by 2 points on the NRS, hip flexion increased by 12.2°, internal rotation by 4.4°, and functional tests were also improved with clinically relevant effects following the MWM. There were no significant changes in the sham group for any outcome variable. Conclusions Pain, hip flexion ROM and physical performance immediately improved after the application of MWM in elderly patients suffering hip OA. The observed immediate changes were of clinical relevance. Future studies are required to determine the long-term effects of this intervention.
Resumo:
BACKGROUND: Musicians are a prone group to suffer from working-related musculoskeletal disorder (WRMD). Conventional solutions to control musculoskeletal pain include pharmacological treatment and rehabilitation programs but their efficiency is sometimes disappointing. OBJECTIVE: The aim of this research is to study the immediate effects of Tuina techniques on WRMD of professional orchestra musicians from the north of Portugal. DESIGN, SETTING, PARTICIPANTS AND INTERVENTIONS: We performed a prospective, controlled, single-blinded, randomized study. Professional orchestra musicians with a diagnosis of WRMD were randomly distributed into the experimental group (n=39) and the control group (n=30). During an individual interview, Chinese diagnosis took place and treatment points were chosen. Real acupoints were treated by Tuina techniques into the experimental group and non-specific skin points were treated into the control group. Pain was measured by verbal numerical scale before and immediately after intervention. RESULTS: After one treatment session, pain was reduced in 91.8% of the cases for the experimental group and 7.9% for the control group. CONCLUSION: Although results showed that Tuina techniques are effectively reducing WRMD in professional orchestra musicians of the north of Portugal, further investigations with stronger measurements, double-blinding designs and bigger simple sizes are needed.
Resumo:
Diabetic macular oedema (DMO) is a leading cause of vision loss in the working-age population worldwide. Corticosteroid drugs have been demonstrated to inhibit the expression of both the vascular endothelial growth factor (VEGF) gene and other anti-inflammatory mediators, such as prostaglandins. Triamcinolone, fluocinolone and dexamethasone are the main steroids that have been studied for the treatment of macular oedema. Over the last few years, several studies have suggested an important role for dexamethasone in the management of DMO. The dexamethasone intravitreal implant (DEX implant) (Ozurdex®; Allergan, Inc., Irvine, CA) is a novel approach approved by the US Food and Drug Administration (FDA) and by the EU for the intravitreal treatment of macular oedema after branch or central retinal vein occlusion, and for the treatment of non-infectious uveitis affecting the posterior segment of the eye. We reviewed manuscripts that had investigated the pharmacokinetics, efficacy and safety of the DEX implant regarding DMO treatment.
Resumo:
Nexplanon (Schering-Plough Limited/Merck Sharp & Dohme Limited (MSD)) is a long active reversible contraceptive method that provides effective contraception for 3 years. It consists of a single, flexible, rod-shaped implant, containing 68 mg etonogestrel. It is 4 cm long, consists of an ethylene vinyl acetate copolymer, a non-absorbable material, and also contains 15 mg of barium sulfate, which makes it visible by X-ray. We describe a case of a 39-year-old woman who experienced a local reaction to the barium sulfate in Nexplanon. She was given medical treatment, but only the removal of the implant resolved the symptoms. After removal there was gradual improvement and 72 h later the patient was asymptomatic. Allergic reaction to barium sulfate is extremely rare: until now, there have only been two cases associated with Nexplanon described in the literature.
Resumo:
Background Several studies link the seamless fit of implant-supported prosthesis with the accuracy of the dental impression technique obtained during acquisition. In addition, factors such as implant angulation and coping shape contribute to implant misfit. Purpose To identify the most accurate impression technique and factors affecting the impression accuracy. Material and Methods A systematic review of peer-reviewed literature was conducted analyzing articles published between 2009 and 2013. The following search terms were used: implant impression, impression accuracy, and implant misfit. A total of 417 articles was identified, 32 were selected for review. Results All 32 selected studies refer to in vitro studies. Fourteen articles compare open and closed impression technique, 8 advocate the open technique and 6 report similar results. Other 14 articles evaluate splinted and non-splinted techniques; all advocating the splinted technique. Polyether material usage was reported in 9; 6 studies tested vinyl polysiloane and 1 study used irreversible hydrocolloid. Eight studies evaluated different copings designs. Intra-oral optical devices were compared in 4 studies. Conclusions The most accurate results were achieved with two configurations: (1) the optical intra-oral system with powder; and (2) the open technique with splinted squared transfer copings, using polyether as impression material.
Percutaneous mitral valvotomy in patients eighteen years old and younger. Immediate and late results
Resumo:
OBJECTIVE - To analyze immediate and late results of percutaneous mitral valvotomy (PMV) in patients <= 18 year. METHODS - Between August '87 and July '97, 48 procedures were performed on 40 patients. The mean age was 15.6 years; 68.7% were females four of whom were pregnant. RESULTS - Success was obtained in 91.7% of the procedures. Immediate complications were severe mitral regurgitation (6.3%) and cardiac tamponade (2.0%). Late follow-up was obtained in 88.8% of the patients (mean value=43.2±33.9 months). NYHA functional class (FC) I or II was observed in 96.2% of the patients and restenosis developed in five patients, at a mean follow-up of 29.7±11.9 months. Three patients presented with severe mitral insufficiency and underwent surgery. Two patients died. CONCLUSION - PMV represents a valid therapeutic option in young patients. In these patients, maybe because of subclinical rheumatic activity, restenosis may have a higher incidence and occur at an earlier stage than in others persons.
Resumo:
OBJECTIVE: The aim of this work was the follow-up and evaluation of valve replacement in children under 12 years of age. METHODS: Forty-four children less than 12 years old were underwent valve replacement at INCOR-HCFMUSP between January 1986 and December 1992. Forty (91%) were rheumatic, 39 (88.7%) were in functional classes II or IV, 19 (43.2%) were operated upon on an emergency basis, and 6 (13.6%) had atrial fibrillation. Biological prostheses (BP) were employed in 26 patients (59.1%), and mechanical prostheses (MP) in 18 (40.9%). Mitral valves were replaced in 30 (68.7%), aortic valves in 8 (18.2%), a tricuspid valve in 1 (2.3%), and double (aortic and mitral) valves in 5 (11.4) of the patients. RESULTS: Hospital mortality was of 4.5% (2 cases). The mean follow-up period was 5.8 years. Re-operations occurred in 63.3% of the patients with BP and in 12.5% of those with MP (p=0.002). Infectious endocarditis was present in 26.3% of the BP, but in none of the cases of MP (p=0.049). Thrombosis occurred in 2 (12.5%) and hemorrhage in one (6.5%) of the patients with a MP. Delayed mortality occurred in 5 (11.9%) of the patients over a mean period of 2.6 years; four had had BP and one had a MP (NS). Actuarial survival and re-operation-free curves after 10 years were respectively, 82.5±7.7 (SD)% and 20.6±15.9%. CONCLUSION: Patients with MP required fewer re-operation, had less infectious endocarditis and lower late mortality rates compared with patients with bioprostheses. The former, therefore, appear to be the best valve replacement for pediatric patients.