903 resultados para FEMORAL-SHAFT FRACTURES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2012

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Maximal-length binary sequences have been known for a long time. They have many interesting properties, one of them is that when taken in blocks of n consecutive positions they form 2ⁿ-1 different codes in a closed circular sequence. This property can be used for measuring absolute angular positions as the circle can be divided in as many parts as different codes can be retrieved. This paper describes how can a closed binary sequence with arbitrary length be effectively designed with the minimal possible block-length, using linear feedback shift registers (LFSR). Such sequences can be used for measuring a specified exact number of angular positions, using the minimal possible number of sensors that linear methods allow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and aim of the study: Patients with anterior cruciate ligament (ACL) reconstruction and femoral catheter analgesia may develop quadriceps amyotrophy. We aimed to determine whether this amyotrophy might be related to a femoral neuropathy. Material and method: After Ethical Committee approval and patients' written informed consent, 17 patients ASA I and II scheduled to undergo ACL reconstruction were recruited. An electromyography (EMG) was performed before the operation in order to exclude a femoral neuropathy. A femoral nerve catheter was inserted before the surgery with the aid of a nerve stimulator, and 20 ml of 0.5% ropivacaine was injected. The operation was done under spinal or general anaesthesia. Postoperative analgesia was provided with 0.2% ropivacaine for 72 hours, in association with oxycodone, paracetamol and ibuprofen. A second EMG was performed 4 weeks after the ACL repair. A femoral neuropathy was defined as a reduction of the surface of the motor response of more than 20%, compared to the first EMG. A third EMG was performed at 6 months if a neuropathy was present. Results: Mean age of this group of patients was 27 years old (range 18-38 y.). Among the 17 patients, 4 developed a transient femoral neuropathy (incidence of 24%) without clinical complain. Conclusion: In this study, the incidence of subclinical femoral neuropathy after ACL reconstruction is high. This lesion may be caused by the femoral catheter (mechanical damage, toxicity of local anaesthesia) or by the Tourniquet. Further studies are needed to investigate the incidence of subclinical neuropathy, according to the type of analgesia (epidural analgesia, PCA) and surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound detection of sub-clinical atherosclerosis (ATS) may help identify individuals at high cardiovascular risk. Most studies evaluated intima-media thickness (IMT) at carotid level. We compared the relationships between main cardiovascular risk factors (CVRF) and five indicators of ATS (IMT, mean and maximal plaque thickness, mean and maximal plaque area) at both carotid and femoral levels. Ultrasound was performed on 496 participants aged 45-64 years randomly selected from the general population of the Republic of Seychelles. 73.4 % participants had ≥ 1 plaque (IMT thickening ≥ 1.2 mm) at carotid level and 67.5 % at femoral level. Variance (adjusted R2) contributed by age, sex and CVRF (smoking, LDL-cholesterol, HDL-cholesterol, blood pressure, diabetes) in predicting any of the ATS markers was larger at femoral than carotid level. At both carotid and femoral levels, the association between CVRF and ATS was stronger based on plaque-based markers than IMT. Our findings show that the associations between CVRF and ATS markers were stronger at femoral than carotid level, and with plaque-based markers rather than IMT. Pending comparison of these markers using harder cardiovascular endpoints, our findings suggest that markers based on plaque morphology assessed at femoral artery level might be useful cardiovascular risk predictors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La radiologie post-­‐mortem a suivi les développements de la radiologie conventionnelle depuis ses débuts. De nos jours, ce sont les dernières techniques de radiologie qui prennent de plus en plus de place en médecine légale, avec les nouveaux outils que sont le scanner et l'imagerie par résonance magnétique. Le centre universitaire romand de médecine légal (CURML) à Lausanne réalise ainsi de façon systématique un examen tomodensitométrique (TDM) complet de chaque corps avant l'autopsie depuis 2008. Cette étude cherche à éprouver l'utilité de la nouvelle méthode de l'imagerie tomodensitométrique dans la détection des fractures de la face par rapport à l'autopsie, méthode traditionnelle. Pour ce faire, les constatations des rapports d'autopsie ont été comparées à celles des rapports de radiologie tomodensitométrique si ces derniers existaient. Ces rapports d'autopsie ont d'abord été sélectionnés s'ils présentaient une forte suspicion de traumatisme facial. Les causes de décès non traumatiques pour la face ont d'abord été exclues (noyade, strangulation volontaire, intoxication, etc.). Les causes les plus traumatiques (accidents de la voie publique, arme à feu, hétéro-­‐agression, etc.) ont été retenues dans un premier temps. Par la suite, les dossiers n'ont pas été retenus si l'autopsie faisait état de lésions traumatiques ne concernant pas la face ou de lésions bénignes de la face. Les constatations des rapports d'autopsie ont finalement été comparées avec ces rapports de radiologie tomodensitométriques s'ils existaient, soit 69 dossiers. Dans un deuxième temps, une seconde lecture des images radiologiques a été effectuée par un radiologue formé. Sur les 146 fractures répertoriées parmi les 69 dossiers restant, 62 (42,4%) ont été décrites à l'autopsie et à la radiologie. 42 (28,8%) ont été décrites dans le rapport d'autopsie uniquement et 42 (28,8%) par la radiologie uniquement. Parmi toutes les fractures de la face détectées uniquement à l'autopsie, toutes sauf une seule ont été retrouvées sur les images d'archive par un radiologue formé. La contribution dans le processus diagnostique de chacune de ces fractures, notée sur une échelle de 1 à 6 par deux médecins-­‐légistes expérimentés, est légère (notes de 1 à 2 dans 98% des cas) concernant la cause du décès. En revanche, concernant les circonstances du décès, on observe une différence entre les deux examinateurs avec des notes de 5 à 6 dans 77% des cas chez l'un, et 19% chez l'autre examinateur. Les deux examinateurs ne sont pas d'accord au sujet de l'importance des fractures dans les cas de traumatismes à haute énergie, l'un jugeant qu'elles sont alors évidentes et l'autre qu'elles permettent d'en savoir plus sur la force exacte de l'impact considéré. Cependant, bien que les fractures de la face ne contribuent que modestement au processus judiciaire suivant un décès, notre étude permet de démontrer la performance de la méthode de l'imagerie tomodensitométrique dans la détection desdites fractures par rapport à l'autopsie avec un taux de détection supérieur.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a case of acute fracture of both sesamoids of the great toe in an athlete. The fractures healed uneventfully after non-surgical treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the feasibility, determine the optimal b-value, and assess the utility of 3-T diffusion-weighted MR imaging (DWI) of the spine in differentiating benign from pathologic vertebral compression fractures.Methods and Materials: Twenty patients with 38 vertebral compression fractures (24 benign, 14 pathologic) and 20 controls (total: 23 men, 17 women, mean age 56.2years) were included from December 2010 to May 2011 in this IRB-approved prospective study. MR imaging of the spine was performed on a 3-T unit with T1-w, fat-suppressed T2-w, gadolinium-enhanced fat-suppressed T1-w and zoomed-EPI (2D RF excitation pulse combined with reduced field-of-view single-shot echo-planar readout) diffusion-w (b-values: 0, 300, 500 and 700s/mm2) sequences. Two radiologists independently assessed zoomed-EPI image quality in random order using a 4-point scale: 1=excellent to 4=poor. They subsequently measured apparent diffusion coefficients (ADCs) in normal vertebral bodies and compression fractures, in consensus.Results: Lower b-values correlated with better image quality scores, with significant differences between b=300 (mean±SD=2.6±0.8), b=500 (3.0±0.7) and b=700 (3.6±0.6) (all p<0.001). Mean ADCs of normal vertebral bodies (n=162) were 0.23, 0.17 and 0.11×10-3mm2/s with b=300, 500 and 700s/mm2, respectively. In contrast, mean ADCs were 0.89, 0.70 and 0.59×10-3mm2/s for benign vertebral compression fractures and 0.79, 0.66 and 0.51×10-3mm2/s for pathologic fractures with b=300, 500 and 700s/mm2, respectively. No significant difference was found between ADCs of benign and pathologic fractures.Conclusion: 3-T DWI of the spine is feasible and lower b-values (300s/mm2) are recommended. However, our preliminary results show no advantage of DWI in differentiating benign from pathologic vertebral compression fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Reversed shoulder prostheses have a semi-congruent design. Furthermore, the center of rotation is inferiorly displaced and a significant tension in the deltoid is often necessary to ensure the joint stability. Consequently, stress transmitted to peri-prosthetic bone may be increased, and could lead to stress fractures. We review a series of patients after reversed shoulder arthroplasty (RSA) and look specifically at the occurrence of postoperative peri-prosthetic stress fractures. Methods: Between 2001 and 2006, 46 consecutive RSA were performed. There were 26 women and 20 men with a mean age of 74 years (53-86). All had preoperative MRI or CT-scan, which did not reveal any fracture. All had a delto-pectoral approach with standard rehabilitation. Review was performed at a mean follow up of 30 months (6-60), and consisted of clinical and radiological (plain X-rays) examinations. Every time a fracture was suspected or in case of recurrent unexpected pain, CT-scan evaluations were performed. The occurrence of peri-prosthetic fractures was looked for. Results: Three patients (7%) sustained a scapular fracture (1 spinal and 2 acromial) without any trauma, between 3 and 6 months after the RSA. Furthermore, one of these patients developed 3 months later a spontaneous clavicular fracture, leading to an overall stress fracture rate of 9%. The four fractures were treated conservatively. Three malunions and one acromial non-union occurred. The range of motion in abduction and flexion decreased significantly after the fracture and stayed limited in all cases. All the three patients reported a recurrence of pain. Conclusion: Peri-prosthetic stress fractures, especially in the acromion and in the spine of the scapula are not unusual after RSA. The etiology is not well known. The increase of stress in peri-prosthetic bone may be due to the semi-congruent design and to an overtension of the deltoid. The management of this complication stays difficult. The conservative treatment leads to mal- or non-union, with persistent pain and limited range of motion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 35-year-old drug addict was found dead in a public toilet with a ruptured groin, which was later diagnosed to be a leaking pseudo-aneurysm. Investigation at the scene revealed impressive external hemorrhage related to a groin wound. Post-mortem computed tomography angiography demonstrated an aneurysm of the right femoral artery with leak of contrast liquid. Signs of blood loss were evident at autopsy, and histological examination revealed necrosis and rupture of the pseudo-aneurysm. Toxicological analyses were positive for methadone, cocaine, citalopram, and benzodiazepines. This is the first case report in the literature of a ruptured femoral pseudo-aneurysm with a post-mortem radiological diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The presence of intravascular foreign bodies is underreported in the literature and is more commonly encountered in clinical practice. We report on a case where an attempt to position a carotid stent resulted in misdeployment of the stent in the femoral artery and its surgical removal. METHODS: A 63-year-old patient admitted to hospital for cerebral stroke underwent thrombolysis for occlusive dissection of right carotid artery and was transferred to our hospital for additional thrombo-aspiration and carotid stenting. RESULTS: The carotid stent was misdeployed incompletely in the femoral artery and had to be removed surgically. CONCLUSIONS: Appropriate knowledge of intravascular migration and deployment failure management should be considered as important as the optimal device deployment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

5 to 10% of all fractures present with a delayed union, whereas 1 to 5% progress to a nonunion, which can be defined as a fracture older than 6 months and lacks any potential to heal without any further intervention. Different fracture and patient related risk factors exist, and the management of a nonunion needs a thorough clinical, radiological and biological workup to classify them in one of the two main categories, the viable nonunions that need essentially more stability, usually by a more rigid fixation, and the non-viable nonunions that need essentially a biological stimulation by decortication and bone grafting. This treatment still remains the first choice with bony healing obtained in 85 to 95% of cases, but it also comes along with certain risks, and some valuable alternatives exist if chosen on the basis of rigid criteria.