Peri-prosthetic stress fractures after reversed shoulder arthroplasty


Autoria(s): Djahangiri A.; Rueff N.; Farron A.
Data(s)

2009

Resumo

Introduction: Reversed shoulder prostheses have a semi-congruent design. Furthermore, the center of rotation is inferiorly displaced and a significant tension in the deltoid is often necessary to ensure the joint stability. Consequently, stress transmitted to peri-prosthetic bone may be increased, and could lead to stress fractures. We review a series of patients after reversed shoulder arthroplasty (RSA) and look specifically at the occurrence of postoperative peri-prosthetic stress fractures. Methods: Between 2001 and 2006, 46 consecutive RSA were performed. There were 26 women and 20 men with a mean age of 74 years (53-86). All had preoperative MRI or CT-scan, which did not reveal any fracture. All had a delto-pectoral approach with standard rehabilitation. Review was performed at a mean follow up of 30 months (6-60), and consisted of clinical and radiological (plain X-rays) examinations. Every time a fracture was suspected or in case of recurrent unexpected pain, CT-scan evaluations were performed. The occurrence of peri-prosthetic fractures was looked for. Results: Three patients (7%) sustained a scapular fracture (1 spinal and 2 acromial) without any trauma, between 3 and 6 months after the RSA. Furthermore, one of these patients developed 3 months later a spontaneous clavicular fracture, leading to an overall stress fracture rate of 9%. The four fractures were treated conservatively. Three malunions and one acromial non-union occurred. The range of motion in abduction and flexion decreased significantly after the fracture and stayed limited in all cases. All the three patients reported a recurrence of pain. Conclusion: Peri-prosthetic stress fractures, especially in the acromion and in the spine of the scapula are not unusual after RSA. The etiology is not well known. The increase of stress in peri-prosthetic bone may be due to the semi-congruent design and to an overtension of the deltoid. The management of this complication stays difficult. The conservative treatment leads to mal- or non-union, with persistent pain and limited range of motion.

Identificador

http://serval.unil.ch/?id=serval:BIB_0FCA691C111A

isbn:1424-7860

http://www.smw.ch/docs/PdfContent/smw-12562.pdf

Idioma(s)

en

Fonte

Annual meeting of the Swiss Society of Orthopedy and Traumatology

Tipo

info:eu-repo/semantics/conferenceObject

inproceedings