1000 resultados para FÍSICA MÉDICA
Resumo:
The progress in radiology is related with the development of new systems of image formation with the lesser dose in the pacient. The improve of the dose in the pacient, without compromising the quality of the image, is one of the responsibilities of a medical physicist in a sector of diagnosis for image. This research has as objective to evaluate the conditions of use of an equipment of x-rays, from tests of quality control. The results gotten in this work have been part of data of an Effective Program of Quality Control (PECQ) of the sector of diagnosis for image of the Hospital das Clínicas da Faculdade de Medicina de Botucatu - UNESP (HCFMB-UNESP)
Resumo:
Paediatric diagnostic radiology can be considered as a separate specialty and with distinct characteristics of the radiology applied in adult patients. This in reason of the variability in the anatomical structures size and bigger sensitivity of tissues. The literature present in its majority methodologies for segmentation and tissue classification in adult patients, and works on tissue quantification are rare. This work had for objective the development of a biological tissue classifier and quantifier algorithm, from histograms, and that converts the quantified average thickness of these tissues for its respective simulator materials. The results will be used in the optimization process of paediatrics images, in future works, since these patients are frequently over exposed to the radiation in the repeated attempts of if getting considered good quality radiographic images. The developed algorithm was capable to read and store the name of all the archives, in the operational system, to filter artifacs, to count and quantify each biological tissues from the histogram of the examination, to obtain the biological tissues average thicknesses and to convert this value into its respective simulator material. The results show that it is possible to distinguish bone, soft, fat and pulmonary tissues from histograms of tomographic examinations of thorax. The quantification of the constituent materials of anthropomorphic phantom made by the algorithm, compared with the data of literature shows that the biggest difference was of 21,6% for bone. However, the literature shows that variations of up to 30% in bone thickness do not influence of significant form in the radiographic image quality. The average thicknesses of biological tissues, quantified for paediatrics patients, show that one phantom can simulate patients with distinct DAP ranges, since variations... (Complete abstract click electronic access below)
Resumo:
Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)
Resumo:
Cosmic radiation has been identi ed as one of the main hazard to crew, aircraft and sensitive equipments involved in long-term missions and even high-altitude commercial ights. Generally, shields are used in spatial units to avoid excessive exposure, by holding the incident radiation. Unfortunatelly, shielding in space is problematic, especially when high-energy cosmic particles are considered, due to the production of large number of secondary particles, mainly neutrons, protons and alpha particles, caused by spallation reactions and quasi-elastic processes of the corpuscular radiation with the shield. Good parameters for checking the secondary particle production at target material are diferential cross section and energy deposited in the shield. Addition experiments, some computer codes based on Monte Carlo method show themselves a suitable tool to calculate shield parameters, due to have evaluated nuclear data libraries implemented on the algorithm. In view of this, the aim of this work is determining the parameters evaluated in shielding materials, by using MCNPX code, who shows good agreement with experimental data from literature. Among the materials, Aluminium had lower emission and production of secondary particles
Resumo:
This study aimed to develop a computer program which systematizes the structural shielding design calculation in diagnostic radiology facilities. For this purpose methodology of the National Council of Radiation Protection and Measurements (NCRP 147[5]) was used. By comparative statistics studies, it was verified if reference parameters values suggested by the US publication correspond to the average national values. The World Wide Web was chosen because of its characteristics as a powerful mean of communication, especially in terms of the wide variety of useful resources and easy access. To compare the reference values of some parameters proposed by NCRP 147 to Brazilian average, studies about the normalized workload per patient, performance of X-ray tube and primary air kerma, unshielded, at one meter from the focal point of the X-ray tube were made. Through this research, relative differences were found. In workload values this differences reached up to 50% in mammography compared to those presented by the NCRP 147; in X-ray tube performance the percentage differences reached 69% in dental radiology, and air kerma results amounted 31% in fluoroscopy. This demonstrates the importance of validation of international protocols to local realities
Resumo:
Betatherapy is a special medical technique using a radioactive source of strontium-90 for the treatment of superficial lesions, especially in dermatology and ophthalmology. Strontium-90 sources emit β radiation, which possesses high ionization power, but a very short distance propagation into matter. This work presents a method of dosimetric analysis of betatherapy using strontium- 90-based instrumentation, commonly used against superficial diseases, such as keloid and pterygium, aiming the description of the dosimetry analysis procedures, which can be easily implemented on tradiotherapy services that offers the betatherapy treatment. IBF-MEDIX radiographic films (conventional films) were exposed to betatherapy applicators during different time intervals according to the activity of the source, and afterwards the optical densities (O. D.) of the radiographic images were measured using an optical densitometer MACBETH. Therefore, the parameters used to make the dosimetric analysis in betatherapy were standardized, as the exposure time depended on the geometry and size of the source, providing an efficient and fast method of dosimetric analysis of the betatherapy equipment of the services, the majority of which do not have the scientific structure to perform this study
Resumo:
The 131I (radioactive iodine) is one of the most used radionuclides in nuclear medicine for diagnosis and treatment. The present study evaluates the dosimetric aspects related to radioiodine therapy after thyroidectomy in patients with thyroid cancer. The samples were studied with 50 patients undergoing treatment, by assessing the exposures of workers (nursing assistants, staff hygiene, medical and physical), the general public (accompanying and family members) and on the environment. To evaluate the workers, was made a survey of the environmental conditions of the room radioiodine and routines adopted by them during the treatment period. Estimating the dose equivalent per month for each employee, we observed that the maximum levels obtained for nursing assistants, the team of hygiene, medical and physicians were considered low in relation to the extent permitted by law. In order to assess the public, some situations have been suggested for the calculation of equivalent doses in which it was possible to verify the fundamental importance of isolating the patient in the 2 days first. Regarding the environment, the radioactive waste generated by patient had volume of 1.0 m3 and activity estimated at 0.91 mCi, taking a decay time for eliminating them about 75 days to reach the allowable value of 2 μCi / kg system of collecting garbage. Therefore, all radioactive waste removed from the patient's room should be sent to the warehouse for temporary storage of radioactive waste, located away from normal work areas
Resumo:
In the recent years, the use of proton beams in radiotherapy has been an outstanding progress (SMITH, 2006). Up to now, computed tomography (CT) is a prerequisite for treatment planning in this kind of therapy because it provides the electron density distribution required for calculation of dose and the interval of doses. However, the use of CT images for proton treatment planning ignores fundamental differences in physical interaction processes between photons and protons and is, therefore, potentially inaccurate (SADROZINSKI, 2004). Proton CT (pCT) can in principle directly measure the density distribution needed in a patient for the dose distribution (SCHULTE, et al, 2004). One important problem that should be solved is the implementation of image reconstruction algorithms. In this sense, it is necessary to know how the presence of materials with different density and composition interfere in the energy deposition by ionization and coulomb excitation, during its trajectory. The study was conducted in two stages, was used in both the program SRIM (The Stopping and Range of Ions in Matter) to perform simulations of the interaction of proton beams with pencil beam type. In the first step we used the energies in the range of 100-250 MeV (ZIEGLER, 1999). The targets were set to 50 mm in length for the beam of 100 MeV, due to its interaction with the target, and short-range, and 70 mm for 150, 200 and 250 MeV The target was composed of liquid water and a layer of 6 mm cortical bone (ICRP). It were made 9 simulations varying the position of the heterogeneity of 5 mm. In the second step the energy of 250 MeV was taken out from the simulations, due to its greater energy and less interaction. The targets were diminished to 50 mm thick to standardize the simulations. The layer of bone was divided into two equal parts and both were put in the ends of the target... (Complete abstract click electronic access below)
Resumo:
The contribution of the total dose due to deposition of secondary energy particles caused by nuclear inelastic processes (n, 2H, 3H, 3He and ) in proton therapy is an opened problem and in discussion. In the calculations of plans implemented for routine treatment, the paid dose is calculated whereas that the proton loses energy by ionization and or coulomb excitement. The contribution of inelastic processes associated with nuclear reactions is not considered, mainly due to the difficulty of processing targets consisting of various materials. In this sense, there are only estimates for pure materials or simple composition (water, for example).This work presents the results of simulations by the Monte Carlo method employing the code MCNPX v2.50 (Monte Carlo N-Particle eXtended) of the contribution to the total dose of secondary particles. The study was implemented in a cylindrical phantom composed by compact bone, for monochromatic beams of protons between 100 and 200 MeV with pencil beam form
Resumo:
Radiotherapy in veterinary practice is already known and widely distributed in large specialized centers of developed countries. In early 2000, there were about 30 radiotherapy equipment specifically designed for the veterinary clinic in the United States. In Brazil, the veterinary radiotherapy is still confined to research in universities, where most of the procedures is radiation therapy performed with superficial x-ray machines, with a voltage between 50 and 150 kVp, focus-distance surface (DFS) between 20,0cm and 40,0cm. As that occurs in human medicine, new research strengthens the development and prospects for the use of radiotherapy as a safe option for treating cancer in animals. This paper presents a methodology for calculating the exposure time for superficial radiotherapy procedures in veterinary medicine for small animals (dogs and cats). The dosimetric parameters of X-rays are determined using a spreadsheet tool for Microsoft Office Excel, developed in this paper for a device Dermopan 2, Veterinary Hospital of UNESP in Araçatuba. Using the worksheet helps the veterinarian to determine the time of exposure to radiation determined for each clinical case, optimize the workflow for professionals in veterinary radiotherapy procedures, which often lack the medical physics in team and at the time of radiotherapy. The correct use of spreadsheet decreases the chances of errors in dose rates of radiation, providing a higher quality of care
Resumo:
The sources of betatherapy for clinical use in Brazil are, the vast majority of strontium-90, radioactive element that is not produced in the country, and therefore requires importation of international laboratories accredited by the International Atomic Energy Agency (IAEA).The use of these resources is always limited the crediting of characteristic values supplied by the manufacturer tables that provide the nominal value of activity and dose distribution to determine the irradiation time of the injury. The Institute of Nuclear Energy Research (IPEN / CNEN-SP) has recently researching the emission profile of these types of radiation sources, and some jobs are being developed with ionization chambers extrapolation for the purpose of standardizing a systematic calibration sources betatherapy. Other studies using parallel measures dosimeters (TLD's) and simulations with the Monte Carlo method. Radiological films have also been used in studies of applicators dosimetric analysis of strontium-90. This paper seeks to analyze the different methods for calibration of applicators betatherapy, already consolidated in studies by examining the advantages and disadvantages of each procedure
Resumo:
The teaching of hearing physiology requires an knowledge integration of Human Anatomy, Biophysics, more precisely Bioacoustics and Bioelectrogenesis, as well as Neurophysiology. Students present difficulty to build knowledge about functional mechanisms of sound conduction and sensory transduction, especially if the elements are not visible forms, as the middle and inner ear structures. To make the teaching about hearing physiology and sensory perception easier, was produced a set of didactical materials about the subject. At first, a resin model that faithfully describes the anatomical relationship of the ossicles with the tympanic membrane was developed. Subsequently, a second model that, besides illustrates the mechanism of acoustic impedance overcoming, also reveals how acoustic sensorial transduction occurs in inner ear, was designed and produced. In the third didactical model, are visualized, through students interaction, areas of the cerebral cortex that interpret the different sensory modalities. In addition, were created three educational videos about hearing problems and a site on Human Hearing Physiology, available on Institute of Biosciences website. The results of this course conclusion monograph are presented in the form of articles that were submitted to Journal Physics in the School and the Journal of the Nucleus of Teaching
Resumo:
After the discovery of ionizing radiation, its applications in various fields of science began to take significant proportions. In the case of medicine, there are the application areas in radiotherapy, diagnostic radiology and nuclear medicine. It was then necessary to create the field of radiological protection to establish the conditions necessary for the safe use of such ionizing radiation. Apply knowledge obtained during the graduation stage and in the practice of radiological protection in the areas of nuclear medicine and diagnostic radiology. In the area of nuclear medicine, tests were made in the Geiger-Muller counters (GM) and the dose calibrator (curiometer), the monitoring tests of radiation, waste management, clean of the Therapeutic room and testing the quality control of gamma-chambers. In the area of radiology, were performed tests of quality control equipment for conventional X-ray equipment and x-ray fluoroscopy, all following the rules of the National Health Surveillance Agency (ANVISA), and reporting of tests. The routine developed in the fields of nuclear medicine in hospitals has proved very useful, since the quality control of GM counters contribute to the values of possible contamination are more reliable. The control of dose calibrator enables the patient not to receive different doses of the recommended amounts, which prevents the repetition of tests and unnecessary exposure to radiation. The management of waste following the rules and laws established and required for its management. Tests for quality control of gamma chambers help to evaluate its medical performance through image. In part of diagnostic radiology, tests for quality control are performed in order to verify that the equipment is acceptable for usage or if repairs are needed. The knowledge acquired at the internship consolidated the learning of graduation course
Resumo:
Stem cells are defined as cells capable of self-renewal and differentiation into specialized cells when submited to external signalings in the enviroment. Among adult stem cells, mesenchymal cells occupy an important position because they can differentiate into mesodermal cells such as osteoblasts, adipocytes and chondrocytes. Cell therapy consists in the use of mesenchymal stem cells (MSC) in the treatment of degenerative diseases and harmed tissue reconstruction. Due to the longstanding and costly procedure for cultivation of MSC, it was proposed the use of low power light sources, such as light emitting diodes (LED), to optimize these factors. Recent works have shown a series of results from the influence of LED light on biological tissues such as increased rate of cell proliferation, increased RNA, DNA and ATP synthesis rate. The purpose of this study is to compare the biomodulator effect of LED light set at wavelengths 630nm ± 10nm and 805nm ± 10nm on the mesenchymal stem cells proliferation. For this, the mesenchymal stem cells culture adopted the procedure used in the Departament of Animal Reproduction and Veterinary Radiology of the Faculty of Veterinary Medicine and Animal Sciences of Botucatu. MSC were obtained from an adult horse bone marrow, and isolated by density gradient separation, with the FICOLL reagent and by centrifugation. The pellet containing the stem cells was removed and these were placed in low glucose DMEM culture medium, containing 10% fetal calf serum and antibiotics. The material was observed daily by inverted microscopy for monitoring the progression of the cells and subsequently the amount of cells were counted in a Neubauer counting chamber. The amount of MSC was obtained by cell culture seeded in 24 wells culture plate and segregated into three distinct groups: Group 1 was irradiated with wavelength set at 630nm ± 10 nm, Group... (Complete abstract click electronic access below)
Resumo:
This study aims to determine surface skin doses in dogs (with suspected pulmonary metastasis) submitted to chest X-rays using the technique of thermoluminescence dosimetry. Twenty seven exams from different dogs were performed at the Faculdade de Medicina Veterinária e Zootecnia da Universidade Estadual Paulista (FMVZ-UNESP/Botucatu). The doses were evaluated using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO4:Dy) produced by the Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN). The pulmonary metastasis exams are carried out in three projections, one dorsal-ventral and two lateral-lateral. During the procedures the projection thicknesses and source-skin surface distances were registered. To simulate the dog phantom the dosimeters were positioned in a cubic simulator (30x30x30 cm) of polymethylmethacrylate (PMMA) filled with water and irradiated according to the parameters of projections with the X-ray energies ranging from 45 to 70 kV. To estimate the surface skin dose the dose-response curves were obtained for X-ray energies of 50 and 70 kV using the diagnostic X-ray beam machine of the Instruments Calibration Laboratory of IPEN for doses of 1.5, 2.0, 2.5, 3.5 and 4.0 mGy. The main difficulty of this work was the dog immobilization that is reflected in poor-quality diagnostic imaging and, consequently, demands the repetition of the exams, which contributes to the increase of the doses received by the animals being studied and the clinical staff. The doses evaluated in this type of procedure are between 0.43 and 4.22 mGy. This research has shown to be extremely important for the assessment of doses involved in veterinary diagnostic radiology procedures, and as a parameter in the individual monitoring of pet’s owners who assist the animal positioning and occupationally exposed workers of the Department of Veterinary Radiology