328 resultados para EMI


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study was conducted to evaluate the liver tissue weight, body fat weight, the fatty somatic index and the liver somatic index of bullfrogs subjected to three photoperiod during the growing phase (initial 30 days) and finishing (60 days). The treatments were 16 h light and 8 h dark, 12 h of light and dark and 8 h light and 16 h dark. The experimental design was completely randomized design with three replications. We used 36 bullfrogs/m2 weighing from 22 to 28 g. The results were submitted to ANOVA and Tukey Test at 5% probability. Differences were found for the weight of body fat, liver tissue weight, liver somatic index and fatty somatic index the bullfrog to the treatments and the study periods and there is greater accumulation of energy to ninety days. The photoperiod did not influence body weight and fat weight of the liver tissue of bullfrog at the end of the fattening period and the difference fatty somatic index and liver somatic index were influenced by body weight of animals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work deals with the development of an experimental study on a power supply of high frequency that provides the toch plasmica to be implemented in PLASPETRO project, which consists of two static converters developed by using Insulated Gate Bipolar Transistor (IGBT). The drivers used to control these keys are triggered by Digital Signal Processor (DSP) through optical fibers to reduce problems with electromagnetic interference (EMI). The first stage consists of a pre-regulator in the form of an AC to DC converter with three-phase boost power factor correction which is the main theme of this work, while the second is the source of high frequency itself. A series-resonant inverter consists of four (4) cell inverters operating in a frequency around 115 kHz each one in soft switching mode, alternating itself to supply the load (plasma torch) an alternating current with a frequency of 450 kHz. The first stage has the function of providing the series-resonant inverter a DC voltage, with the value controlled from the power supply provided by the electrical system of the utility, and correct the power factor of the system as a whole. This level of DC bus voltage at the output of the first stage will be used to control the power transferred by the inverter to the load, and it may vary from 550 VDC to a maximum of 800 VDC. To control the voltage level of DC bus driver used a proportional integral (PI) controller and to achieve the unity power factor it was used two other proportional integral currents controllers. Computational simulations were performed to assist in sizing and forecasting performance. All the control and communications needed to stage supervisory were implemented on a DSP

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work was carried out in the city of Maringa, located in the Northwest region of Parana, with the aim of analyzing economically the yellow passion fruit crop (Passiflora edulis Sims. f. flavicarpa Deg.), comparing organic and conventional production systems. To estimate technical coefficients, planting and production costs, and profitability indicators of culture, the data were surveyed from technicians of the region and based in experimental work, carried out at the Experimental Farm of lguaterm from the Maringa State University, in the period of june/2002 to july/2004. The total production costs of the culture in two agricultural years reached a value 12.94% higher for the conventional system, and in this same period the medium index of profitability was 21.39% higher for the organic system. The organic production system was economically feasible and provided a larger index of profitability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a 2kW single-phase high power factor boost rectifier with four cells in interleave connection, operating in critical conduction mode, and employing a soft-switching technique, controlled by Field Programmable Gate Array (FPGA). The soft-switching technique Is based on zero-current-switching (ZCS) cells, providing ZC (zero-current) turn-on and ZCZV (zero-current-zero-voltage) turn-off for the active switches, and ZV (zero-voltage) turn-on and ZC (zero-current) turn-off for the boost diodes. The disadvantages related 'to reverse recovery effects of boost diodes operated in continuous conduction mode (additional losses, and electromagnetic interference (EMI) problems) are minimized, due to the operation in critical conduction mode. In addition, due to the Interleaving technique, the rectifer's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) In the input current, in compliance with the TEC61000-3-2 standards. The digital controller has been developed using a hardware description language (VHDL) and implemented using a XC2S200E-SpartanII-E/Xilinx FPGA device, performing a true critical conduction operation mode for four interleaved cells, and a closed-loop to provide the output voltage regulation, like as a pre-regulator rectifier. Experimental results are presented for a 2kW implemented prototype with four interleaved cells, 400V nominal output voltage and 220V(rms) nominal input voltage, in order to verify the feasibility and performance of the proposed digital control through the use of a FPGA device.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel single-phase voltage source rectifier capable to achieve High-Power-Factor (HPF) for variable speed refrigeration system application, is proposed in this paper. The proposed system is composed by a single-phase high-power-factor boost rectifier, with two cells in interleave connection, operating in critical conduction mode, and employing a soft-switching technique, controlled by a Field Programmable Gate Array (FPGA), associated with a conventional three-phase IGBT bridge inverter (VSI - Voltage Source Inverter), controlled by a Digital Signal Processor (DSP). The soft-switching technique for the input stage is based on zero-current-switching (ZCS) cells. The rectifier's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the EEC61000-3-2 standards. The digital controller for the output stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at a refrigerator prototype.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Discutir os aspectos das urgências odontológicas relacionadas aos traumatismos dentários, disponibilizando mais informações para médicos pediatras ou plantonistas de serviços de atendimento de urgências e emergências. FONTES DE DADOS: O levantamento dos dados foi realizado na base de dados Pubmed e Bireme, selecionando os artigos dos últimos 13 anos. As palavras-chave utilizadas foram: traumatismo dentário, dente decíduo e dente permanente. Os critérios de inclusão utilizados foram: artigos em inglês e português sobre incidência, prevalência e etiologia, guias de procedimentos e casos clínicos apenas de traumatismo dentário, sendo excluídos artigos de clareamento de dentes traumatizados, traumas faciais ósseos e casos clínicos de acompanhamento reduzido. SÍNTESE DOS DADOS: Os dados foram descritos de forma concisa para se tornar um guia de fácil leitura e rápido acesso em relação à conduta, necessidade de atendimento imediato e correta escolha de soluções para armazenagem dos dentes e fragmentos. CONCLUSÕES: O conhecimento sobre o assunto, a agilidade no tratamento de urgência e o correto encaminhamento do paciente proporcionam melhor prognóstico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)