Sizing PZT Transducers in Impedance-Based Structural Health Monitoring


Autoria(s): Baptista, Fabricio G.; Vieira Filho, Jozué; Inman, Daniel J.
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

20/05/2014

20/05/2014

01/06/2011

Resumo

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

A theoretical and experimental analysis regarding the correct size of PZT (Lead Zirconate Titanate) transducers used in structural health monitoring (SHM) systems based on the electromechanical impedance (EMI) technique is presented. Tests were carried out on aluminum structures using 5A and 5H PZT patches of various sizes. The results show that the sensitivity of SHM systems for damage detection can be optimized if the transducers are correctly sized according to the proposed procedure.

Formato

1405-1414

Identificador

http://dx.doi.org/10.1109/JSEN.2010.2098865

IEEE Sensors Journal. Piscataway: IEEE-Inst Electrical Electronics Engineers Inc, v. 11, n. 6, p. 1405-1414, 2011.

1530-437X

http://hdl.handle.net/11449/9795

10.1109/JSEN.2010.2098865

WOS:000289805300016

Idioma(s)

eng

Publicador

Institute of Electrical and Electronics Engineers (IEEE)

Relação

IEEE Sensors Journal

Direitos

closedAccess

Palavras-Chave #Electromechanical impedance #PZT ceramics #structural engineering #structural health monitoring (SHM)