917 resultados para Corneal biomechanics
Resumo:
Objective: To investigate the effect of socioeconomic deprivation on cornea graft survival in the United Kingdom.
Design: Retrospective cohort study.
Participants: All the recipients (n = 13?644) undergoing their first penetrating keratoplasty (PK) registered on the United Kingdom Transplant Registry between April 1999 and March 2011 were included.
Methods: Data of patients' demographic details, indications, graft size, corneal vascularization, surgical complication, rejection episodes, and postoperative medication were collected at the time of surgery and 1, 2, and 5 years postoperatively. Patients with endophthalmitis were excluded from the study. Patients' home postcodes were used to determine the socioeconomic status using a well-validated deprivation index in the United Kingdom: A Classification of Residential Neighborhoods (ACORN). Kaplan–Meier survival and Cox proportional hazards regression were used to evaluate the influence of ACORN categories on 5-year graft survival, and the Bonferroni method was used to adjust for multiple comparisons.
Main Outcome Measures: Patients' socioeconomic deprivation status and corneal graft failure.
Results: A total of 13?644 patients received their first PK during the study periods. A total of 1685 patients (13.36%) were lost to follow-up, leaving 11?821 patients (86.64%) for analysis. A total of 138 of the 11?821 patients (1.17%) developed endophthalmitis. The risk of graft failure within 5 years for the patients classified as hard-pressed was 1.3 times that of the least deprived (hazard ratio, 1.3; 95% confidence interval, 1.1–1.5; P = 0.003) after adjusting for confounding factors and indications. There were no statistically significant differences between the causes of graft failure and the level of deprivation (P = 0.14).
Conclusions: Patients classified as hard-pressed had an increased risk of graft failure within 5 years compared with the least deprived patients.
Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article
Resumo:
Corneal endothelial cells from normal and traumatized human, primate, cat and rabbit eyes were studied by specular microscopy. Morphometric analysis was performed on micrographs of corneal endothelium using a semi-automated image analysis system. The results showed that under normal conditions the corneal endothelium of all four species exhibit major morphological similarities (mean cell areas: human 317 +/- 32 microns 2, primate 246 +/- 22 microns2, cat 357 +/- 25 microns 2, rabbit 308 +/- 35 microns 2). The normal corneal endothelium in man was found to be more polymegethous than that of the other species. Trauma to cat, primate and human corneas resulted in a long-term reduction in endothelial cell density and enhanced polymegethism. In contrast, the reparative response of the rabbit ensured the reformation of an essentially normal monolayer following injury. Endothelial giant cells were a normal inclusion in the rabbit corneal endothelium but were only significant in cat, primate and man following trauma. The presence of corneal endothelial giant cells in amitotic corneas may therefore represent a compensatory response in the absence of mitotic potential.
Resumo:
Vertebroplasty is a minimally invasive surgical procedure, which requires efficacious percutaneous cement delivery via a cannulated needle to restore the strength and stiffness in osteoporotic vertebral bodies. Cement viscosity is understood to influence the injectability, cohesion and cement retention within the vertebral body. Altering the liquid to powder ratio modifies the viscosity of bone cement; however, the cement viscosity-response association between cement fill and augmentation of strength and stiffness is unknown. The aim of this study was to determine the relationship between viscosity, cement fill and the potential augmentation of strength and stiffness in an open pore foam structure that was representative of osteoporotic cancellous bone using an in vitro prophylactic vertebroplasty model. The results showed a strong linear correlation between compressive strength and stiffness augmentation with percentage cement fill, the extent of which was strongly dependent on the cement viscosity. Significant forces were required to ensure maximum delivery of the high viscosity cement using a proprietary screw-driven cement delivery technology. These forces could potentially exceed the normal human physical limit. Similar trends were observed when comparing the results from this study and previously reported cadaveric and animal based in vitro models.
Resumo:
Purpose: To assess the demographics and distribution of corneal astigmatism before cataract surgery in Chinese patients. Setting: State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China. Design: Clinic-based cross-sectional study. Methods: From July 2009 to May 2011, preoperative bilateral partial coherence interferometry (IOLMaster) was performed in consecutive patients having cataract surgery. Patient demographics and keratometric data were recorded. Results: The mean age of the 2849 patients (4831 eyes) was 70.56 years ± 9.55 (SD); there was a predominance of women patients (64.0%). The mean axial length was 23.58 ± 1.13 mm. The mean corneal astigmatism in this cohort was 1.01 D (range 0.05 to 6.59 D). Corneal astigmatism was between 0.25 D and 1.25 D in 67.7% of eyes, 1.25 D or higher in 27.5% eyes, and less than 0.25 D in 4.8% of eyes. Astigmatism was with the rule in 25.1% of eyes, against the rule (ATR) in 58.2% of eyes, and oblique in 16.7% of eyes. The mean steep keratometry measurement was 44.76 ± 1.56 D. Against-the-rule astigmatism increased significantly with older age. Conclusions: Corneal astigmatism largely fell between 0.25 D and 1.25 D in these predominantly elderly female Chinese patients, and ATR astigmatism increased with age. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. © 2012 ASCRS and ESCRS.
Corneal complications associated with topical ophthalmic use of nonsteroidal antiinflammatory drugs.
Resumo:
PURPOSE:
To explore the potential association between adverse corneal events and the use of topical nonsteroidal antiinflammatory drugs (NSAIDs).
SETTING:
Practice-based reports.
METHODS:
A detailed case-reporting form and request for medical records were sent to all practices reporting cases of corneal or conjunctival pathology in association with the use of topical NSAIDs to the American Society of Cataract and Refractive Surgery. Cases were classified as "mild," "moderate," or "severe" according to predetermined clinical criteria.
RESULTS:
Records of 140 eyes (129 patients) were reviewed; 51 cases (36.4%) were mild, 55 (39.3%) moderate, and 34 (24.3%) severe. An association with a specific topical NSAID was confirmed in 117 cases (81.8%). Most confirmed cases (53.8%) involved generic diclofenac (Falcon). Cases associated with brand diclofenac (Voltaren, CIBA Vision) and ketorolac (Acular, Allergan) were more likely to have ocular comorbidity and to have received significantly higher total doses of NSAIDs. Neither "off-label" use nor use of any specific agent was associated with severe compared to mild or moderate disease. However, patients with more severe adverse events were more likely to have a history of diabetes, previous surgery in the affected eye, and surgery other than cataract. Cases not occurring in the perioperative period had significantly worse outcomes, had significantly more ocular comorbidities, and received nearly 3 times the dose of NSAIDs.
CONCLUSIONS:
While topical NSAIDs as a class may be associated with severe adverse events, such events appeared to require potentiation in the form of high total doses, ocular comorbidities, or both with Acular and Voltaren. Severe adverse events might have been more likely to occur at lower doses and in routine postoperative settings with generic diclofenac.
Resumo:
PURPOSE:
We sought to measure the impact of central corneal thickness (CCT), a possible risk factor for glaucoma damage, and corneal hysteresis, a proposed measure of corneal resistance to deformation, on various indicators of glaucoma damage.
DESIGN:
Observational study.
METHODS:
Adult patients of the Wilmer Glaucoma Service underwent measurement of hysteresis on the Reichert Ocular Response Analyzer and measurement of CCT by ultrasonic pachymetry. Two glaucoma specialists (H.A.Q., N.G.C.) reviewed the chart to determine highest known intraocular pressure (IOP), target IOP, diagnosis, years with glaucoma, cup-to-disk ratio (CDR), mean defect (MD), pattern standard deviation (PSD), glaucoma hemifield test (GHT), and presence or absence of visual field progression.
RESULTS:
Among 230 subjects, the mean age was 65 +/- 14 years, 127 (55%) were female, 161 (70%) were white, and 194 (85%) had a diagnosis of primary open-angle glaucoma (POAG) or suspected POAG. In multivariate generalized estimating equation models, lower corneal hysteresis value (P = .03), but not CCT, was associated with visual field progression. When axial length was included in the model, hysteresis was not a significant risk factor (P = .09). A thinner CCT (P = .02), but not hysteresis, was associated with a higher CDR at the most recent examination. Neither CCT nor hysteresis was associated with MD, PSD, or GHT "outside normal limits."
CONCLUSIONS:
Thinner CCT was associated with the state of glaucoma damage as indicated by CDR. Axial length and corneal hysteresis were associated with progressive field worsening.
Resumo:
PURPOSE: To estimate the relationships between ocular parameters and tonometrically measured intraocular pressure (IOP), to determine the influence of ocular parameters on different instrument measurements of IOP, and to evaluate the association of ocular parameters with a parameter called hysteresis. METHODS: Patients presenting at a glaucoma clinic were recruited for this study. Subjects underwent IOP measurement with the Goldmann applanation tonometer (GAT), the TonoPen, and the Reichert Ocular Response Analyzer (ORA), and also measurements of central corneal thickness (CCT), axial length, corneal curvature, corneal astigmatism, central visual acuity, and refractive error. Chart information was reviewed to determine glaucoma treatment history. The ORA instrument provided a measurement called corneal hysteresis. The association between measured IOP and the other ocular characteristics was estimated using generalized estimating equations. RESULTS: Among 230 patients, IOP measurements from the TonoPen read lowest, and ORA read highest, and GAT measurements were closest to the mean IOP of the 3 instruments. In a multiple regression model adjusting for age, sex, race, and other ocular characteristics, a 10 microm increase in CCT was associated with an increase of 0.79 mm Hg measured IOP in untreated eyes (P<0.0001). Of the 3 tonometers, GAT was the least affected by CCT (0.66 mm Hg/10 mum, P<0.0001). Hysteresis was significantly correlated with CCT with a modest correlation coefficient (r=0.20, P<0.0007). CONCLUSIONS: Among parameters related to measured IOP, features in addition to CCT, such as hysteresis and corneal curvature, may also be important. Tonometric instruments seem to be affected differently by various physiologic characteristics.
Resumo:
PURPOSE: To evaluate the association between corneal hysteresis and axial length/refractive error among rural Chinese secondary school children. DESIGN: Cross-sectional cohort study. METHODS: Refractive error (cycloplegic auto-refraction with subjective refinement), central corneal thickness (CCT) and axial length (ultrasonic measurement), intraocular pressure (IOP), and corneal hysteresis (Reichert Ocular Response Analyzer) were measured on a rural school-based cohort of children. RESULTS: Among 1,233 examined children, the mean age was 14.7 +/- 0.8 years and 699 (56.7%) were girls. The mean spherical equivalent (n = 1,232) was -2.2 +/- 1.6 diopters (D), axial length (n = 643) was 23.7 +/- 1.1 mm, corneal hysteresis (n = 1,153) was 10.7 +/- 1.6 mm Hg, IOP (n = 1,153) was 17.0 +/- 3.4 mm Hg, and CCT (n = 1,226) was 553 +/- 33 microns. In linear regression models, longer axial length was significantly (P < .001 for both) associated with lower corneal hysteresis and higher IOP. Hysteresis in this population was significantly (P < .001) lower than has previously been reported for normal White children (n = 42, 12.3 +/- 1.3 mm Hg), when adjusting for age and gender. This difference did not appear to depend on differences in axial length between the populations, as it persists when only Chinese children with normal uncorrected vision are included. CONCLUSIONS: Prospective studies will be needed to determine if low hysteresis places eyes at risk for axial elongation secondary or if primary elongation results in lower hysteresis.
Resumo:
PURPOSE: Recent studies report that increased corneal edema because of contact lens wear under closed lids is associated with elevated Goldmann intraocular pressure (GAT IOP). We sought to assess whether the impact of postoperative corneal edema on GAT IOP would be similar and to determine the differential effect of different amounts of edema. METHODS: The setting is a tertiary level cataract clinic in Shantou, China. Pre- and postoperative (day 1) GAT IOP, central corneal thickness (CCT), corneal hysteresis, corneal resistance factor, and radius of corneal curvature were measured for consecutive patients undergoing phacoemulsification surgery by 2 experienced surgeons. Corneal edema was calculated as the percentage increase in CCT. RESULTS: Among 136 subjects (mean age, 62.5 ± 15.4 years; 53.7% women), the mean increase in CCT was 10.3% postoperatively. Greater corneal edema was associated with lower GAT IOP in unadjusted analyses (P < 0.03) and in linear regression models (P < 0.01). In the model, higher corneal resistance factor (P < 0.001), lower corneal hysteresis (P < 0.001), and steeper radius of corneal curvature (P < 0.001) were associated with higher GAT IOP. Among subjects with edema < the median, edema was associated with lower GAT IOP (P = 0.004), whereas among those with edema ≥ the median, edema was not associated with GAT IOP. An increase in CCT of 7% was associated with an 8 mm Hg underestimation of GAT IOP in our models. CONCLUSIONS: The effect of postoperative edema on GAT IOP seems to be the opposite of contact lens-induced edema. The magnitude of the effect is potentially relevant to patient management.
Resumo:
PURPOSE: To describe the distribution of central corneal thickness (CCT), intraocular pressure (IOP), and their determinants and association with glaucoma in Chinese adults.DESIGN: Population-based cross-sectional study.METHODS: Chinese adults aged 50 years and older were identified using cluster random sampling in Liwan District, Guangzhou. CCT (both optical [OCCT] and ultrasound [UCCT]), intraocular pressure (by Tonopen, IOP), refractive error (by autorefractor, RE), radius of corneal curvature (RCC), axial length (AL), and body mass index (BMI) were measured, and history of hypertension and diabetes (DM) was collected by questionnaire. Right eye data were analyzed.RESULTS: The mean values of OCCT, UCCT, and IOP were 512 ± 29.0 μm, 542 ± 31.4 μm, and 15.2 ± 3.1 mm Hg, respectively. In multiple regression models, CCT declined with age (P < .001) and increased with greater RCC (P < .001) and DM (P = .037). IOP was positively associated with greater CCT (P < .001), BMI (P < .001), and hypertension (P < .001). All 25 persons with open-angle glaucoma had IOP <21 mm Hg. CCT did not differ significantly between persons with and without open- or closed-angle glaucoma. Among 65 persons with ocular hypertension (IOP >97.5th percentile), CCT (555 ± 29 μm) was significantly (P = .01) higher than for normal persons.CONCLUSIONS: The distributions of CCT and IOP in this study are similar to that for other Chinese populations, though IOP was lower than for European populations, possibly due to lower BMI and blood pressure. Glaucoma with IOP <21 mm Hg is common in this population. We found no association between glaucoma and CCT, though power (0.3) for this analysis was low.
Resumo:
BACKGROUND: We sought to determine whether corneal biomechanical parameters are predictive of reduction in axial length after anti-metabolite trabeculectomy. METHODS: Chinese subjects undergoing trabeculectomy with mitomycin C by a single experienced surgeon underwent the following measurements: Corneal hysteresis (CH, Ocular Response Analyzer, Reichert Ophthalmic Instruments), Goldmann intra-ocular pressure (IOP), central corneal thickness (CCT) and axial length (AL, IOLMaster, Carl Zeiss Meditec, Dublin, CA) were measured pre-operatively, and AL, CH and IOP were measured 1 day and 1 week post-operatively. RESULTS: Mean age of 31 subjects was 52.0 ± 15.2 years, and 15 (48.4%) were female. The mean pre-operative IOP of 21.4 ± 9.3 mmHg was reduced to 8.2 ± 4.6 mmHg 1 day and 11.0 ± 4.4 mmHg 1 week post-operatively (p < 0.001). AL declined from 22.99 ± 0.90 to 22.76 ± 0.87 mm at 1 day and 22.74 ± 0.9 mm at 1 week; 30/31 (%) eyes had a decline in AL (p < 0.001, sign test). In multivariate linear regression models including post-operative data from 1 day and 1 week, greater decline in Goldmann IOP (p < 0.0001, greater pre-op axial length (p < 0.001) and lower pre-operative CH (p = 0.03), were all associated with greater decline in post-operative axial length. CONCLUSIONS: Eyes with lesser ability of the ocular coat to absorb energy (lower CH) had significantly greater decrease in axial length after trabeculectomy-induced IOP-lowering.
Regenerative potential of corneal endothelium from patients with fuchs endothelial corneal dystrophy
Resumo:
La dystrophie cornéenne endothéliale de Fuchs (FECD, pour l’abréviation du terme anglais « Fuchs endothelial corneal dystrophy ») est une maladie de l'endothélium cornéen. Sa pathogenèse est mal connue. Aucun traitement médical n’est efficace. Le seul traitement existant est chirurgical et consiste dans le remplacement de l’endothélium pathologique par un endothélium sain provenant de cornées de la Banque des yeux. Le traitement chirurgical, en revanche, comporte 10% de rejet immunologique. Des modèles expérimentaux sont donc nécessaires afin de mieux comprendre cette maladie ainsi que pour le développement de traitements alternatifs. Le but général de cette thèse est de développer un modèle expérimental de la FECD en utilisant le génie tissulaire. Ceci a été réalisé en trois étapes. 1) Tout d'abord, l'endothélium cornéen a été reconstruit par génie tissulaire en utilisant des cellules endothéliales en culture, provenant de patients atteints de FECD. Ce modèle a ensuite été caractérisé in vitro. Brièvement, les cellules endothéliales cornéennes FECD ont été isolées à partir de membranes de Descemet prélevées lors de greffes de cornée. Les cellules au deuxième ou troisième passages ont ensuite été ensemencées sur une cornée humaine préalablement décellularisée. Suivant 2 semaines de culture, les endothélia cornéens reconstruits FECD (n = 6) ont été évalués à l'aide d'histologie, de microscopie électronique à transmission et d’immunomarquages de différentes protéines. Les endothélia cornéens reconstruits FECD ont formé une monocouche de cellules polygonales bien adhérées à la membrane de Descemet. Les immunomarquages ont démontré la présence des protéines importantes pour la fonctionnalité de l’endothélium cornéen telles que Na+-K+/ATPase α1 et Na+/HCO3-, ainsi qu’une expression faible et uniforme de la protéine clusterine. 2) Deux techniques chirurgicales (DSAEK ; pour « Descemet stripping automated endothelial keratoplasty » et la kératoplastie pénétrante) ont été comparées pour la transplantation cornéenne dans le modèle animal félin. Les paramètres comparés incluaient les défis chirurgicaux et les résultats cliniques. La technique « DSAEK » a été difficile à effectuer dans le modèle félin. Une formation rapide de fibrine a été observée dans tous les cas DSAEK (n = 5). 3) Finalement, la fonctionnalité in vivo des endothélia cornéens reconstruits FECD a été évaluée (n = 7). Les évaluations in vivo comprenaient la transparence, la pachymétrie et la tomographie par cohérence optique. Les évaluations post-mortem incluaient la morphométrie des cellules endothéliales, la microscopie électronique à transmission et des immunomarquage de protéines liées à la fonctionnalité. Après la transplantation, la pachymétrie a progressivement diminué et la transparence a progressivement augmenté. Sept jours après la transplantation, 6 des 7 greffes étaient claires. La microscopie électronique à transmission a montré la présence de matériel fibrillaire sous-endothélial dans toutes les greffes d’endothelia reconstruits FECD. Les endothélia reconstruits exprimaient aussi des protéines Na+-K+/ATPase et Na+/HCO3-. En résumé, cette thèse démontre que les cellules endothéliales de la cornée à un stade avancé FECD peuvent être utilisées pour reconstruire un endothélium cornéen par génie tissulaire. La kératoplastie pénétrante a été démontrée comme étant la procédure la plus appropriée pour transplanter ces tissus reconstruits dans l’œil du modèle animal félin. La restauration de l'épaisseur cornéenne et de la transparence démontrent que les greffons reconstruits FECD sont fonctionnels in vivo. Ces nouveaux modèles FECD démontrent une réhabilitation des cellules FECD, permettant d’utiliser le génie tissulaire pour reconstruire des endothelia fonctionnels à partir de cellules dystrophiques. Les applications potentielles sont nombreuses, y compris des études physiopathologiques et pharmacologiques.