883 resultados para Computer aided design


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Estudi i disseny de la implantació d'un ERP (Enterprise Resource Planning) en una fàbrica de fruits secs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Disseny d'un programari de gestió de magatzems on quedin reflectides les seves entrades, sortides i altres operacions pròpies dels magatzems. El programari ha de ser escalable i perdurar en el temps a més a més de permetre operacions d¿actualització, esborrat, addicció de dades i les operacionsfonamentals de consulta.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A pioneer team of students of the University of Girona decided to design and develop an autonomous underwater vehicle (AUV) called ICTINEU-AUV to face the Student Autonomous Underwater Challenge-Europe (SAUC-E). The prototype has evolved from the initial computer aided design (CAD) model to become an operative AUV in the short period of seven months. The open frame and modular design principles together with the compatibility with other robots previously developed at the lab have provided the main design philosophy. Hence, at the robot's core, two networked computers give access to a wide set of sensors and actuators. The Gentoo/Linux distribution was chosen as the onboard operating system. A software architecture based on a set of distributed objects with soft real time capabilities was developed and a hybrid control architecture including mission control, a behavioural layer and a robust map-based localization algorithm made ICTINEU-AUV the winning entry

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trans-apical aortic valve replacement (AVR) is a new and rapidly growing therapy. However, there are only few training opportunities. The objective of our work is to build an appropriate artificial model of the heart that can replace the use of animals for surgical training in trans-apical AVR procedures. To reduce the necessity for fluoroscopy, we pursued the goal of building a translucent model of the heart that has nature-like dimensions. A simplified 3D model of a human heart with its aortic root was created in silico using the SolidWorks Computer-Aided Design (CAD) program. This heart model was printed using a rapid prototyping system developed by the Fab@Home project and dip-coated two times with dispersion silicone. The translucency of the heart model allows the perception of the deployment area of the valved-stent without using heavy imaging support. The final model was then placed in a human manikin for surgical training on trans-apical AVR procedure. Trans-apical AVR with all the necessary steps (puncture, wiring, catheterization, ballooning etc.) can be realized repeatedly in this setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this investigation, high-resolution, 1x1x1-mm(3) functional magnetic resonance imaging (fMRI) at 7 T is performed using a multichannel array head coil and a surface coil approach. Scan geometry was optimized for each coil separately to exploit the strengths of both coils. Acquisitions with the surface coil focused on partial brain coverage, while whole-brain coverage fMRI experiments were performed with the array head coil. BOLD sensitivity in the occipital lobe was found to be higher with the surface coil than with the head array, suggesting that restriction of signal detection to the area of interest may be beneficial for localized activation studies. Performing independent component analysis (ICA) decomposition of the fMRI data, we consistently detected BOLD signal changes and resting state networks. In the surface coil data, a small negative BOLD response could be detected in these resting state network areas. Also in the data acquired with the surface coil, two distinct components of the positive BOLD signal were consistently observed. These two components were tentatively assigned to tissue and venous signal changes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Helical tomotherapy is a relatively new intensity-modulated radiation therapy (IMRT) treatment for which room shielding has to be reassessed for the following reasons. The beam-on-time needed to deliver a given target dose is increased and leads to a weekly workload of typically one order of magnitude higher than that for conventional radiation therapy. The special configuration of tomotherapy units does not allow the use of standard shielding calculation methods. A conventional linear accelerator must be shielded for primary, leakage and scatter photon radiations. For tomotherapy, primary radiation is no longer the main shielding issue since a beam stop is mounted on the gantry directly opposite the source. On the other hand, due to the longer irradiation time, the accelerator head leakage becomes a major concern. An analytical model based on geometric considerations has been developed to determine leakage radiation levels throughout the room for continuous gantry rotation. Compared to leakage radiation, scatter radiation is a minor contribution. Since tomotherapy units operate at a nominal energy of 6 MV, neutron production is negligible. This work proposes a synthetic and conservative model for calculating shielding requirements for the Hi-Art II TomoTherapy unit. Finally, the required concrete shielding thickness is given for different positions of interest.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Voltage fluctuations caused by parasitic impedances in the power supply rails of modern ICs are a major concern in nowadays ICs. The voltage fluctuations are spread out to the diverse nodes of the internal sections causing two effects: a degradation of performances mainly impacting gate delays anda noisy contamination of the quiescent levels of the logic that drives the node. Both effects are presented together, in thispaper, showing than both are a cause of errors in modern and future digital circuits. The paper groups both error mechanismsand shows how the global error rate is related with the voltage deviation and the period of the clock of the digital system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aquest text és un recull de procediments per inserir els blocs d'AutoCAD de forma més eficient, en la resolució de problemes prèviament tipificats: la PRIMERA PART descriu protocols d'actuació que l'usuari haurà d'aplicar manualment, mentre que la SEGONA PART ofereix rutines programades en AutoLISP i VisualLISP que l'eximiran d'aquesta obligació.Si ho deixéssim aquí, però, podria semblar que els mateixos mètodes manuals presentats en primer lloc són després els que AutoLISP automatitza; per això convé aclarir que la problemàtica de la PRIMERA PART, tot i que pròxima a la de la SEGONA, és diferent i reprodueix el contingut d'una monografia (BLOCS I GEOMETRIA: 5 EXERCICIS COMENTATS) que forma part del material de suport a l'assignatura ELEMENTS DE CAD, impartida per l'autor en l'ETS d'Enginyeria de Telecomunicació de Barcelona i que té per objecte cobrir el buit bibliogràfic que es detectava en el vessant geomètric de la inserció de blocs, a diferència del que s'ocupa de l'estructura de dades més adient en cada context (incrustació de dibuixos amb INSERT versus vinculació mitjançant REFX), més profusament tractat, proposant una sistematització tipològica dels casos on l'escala és funció lineal d'una distància.La SEGONA PART va més enllà i amplia el repertori d'AutoCAD amb les ordres GINSERT, RATREDIT, INSERTOK, INS2D, INS3D, BLOQUEOK, DESCOMPOK, DEF-TRANSF, APL-TRANSF-V i APL-TRANSF-N, de les quals INS2D i INS3D (INSERTOK és una versió simplificada de INS2D, per a blocs sense atributs) són l'aportació més innovadora i que més lluny porta les potencialitats de la inserció de blocs: resumint-ho en una frase, es tracta d’aconseguir que la inserció d’un bloc (que pot ser l’original, un bloc constituït per una inserció de l’original o un de constituït per la inserció del precedent) s’encabeixi en un marc prèviament establert, a semblança de les ordres ESCALA o GIRA, que mitjançant l'opció Referencia apliquen als objectes seleccionats la transformació d'escalat o de rotació necessària per tal que un element de referència assoleixi una determinada grandària o posició. Tot i que, per identificar amb encert el nucli del problema, serà inevitable introduir una reflexió: quan s’ha tingut la precaució de referir un bloc 2D a un quadrat unitari ortogonal, inserir-lo de manera que s’adapti a qualsevol marc rectangular establert en el dibuix és immediat, però ja no ho és tant concatenar insercions de manera que, a més d’una combinació simple de escalat, gir i translació, l’operació dugui implícita una transformació de cisallament. Perquè és clar que si inserim el bloc girat i convertim la inserció en un bloc que al seu torn tornem a inserir, ara però amb escalat no uniforme, el transformat del quadrat de referència primitiu serà un paral·lelogram, però el problema és: dibuixat un marc romboïdal concret, ¿quin gir caldrà donar a la primera inserció, i quin gir i factors d’escala caldrà aplicar a la segona perquè el quadrat de referència s’adapti al marc? El problema es complica si, a més, volem aprofitar el resultat de la primera inserció per a d’altres paral·lelograms, organitzant un sistema no redundant de insercions intermèdies. Doncs bé: INS2D i INS3D donen satisfacció a aquestes qüestions (la segona ja no contempla l'encaix en un paral·lelogram, sinó en un paral·lelepípede) i són aplicables a blocs proveïts d’atributs, no només de tipus convencional (els continguts en el pla de base del bloc, únics de funcionament garantit amb l’ordre INSERT), sinó també dels situats i orientats lliurement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Printed electronics is an emerging concept in electronics manufacturing and it is in very early development stage. The technology is not stable, design kits are not developed, and flows and Computer Aided Design (CAD) tools are not fixed yet. The European project TDK4PE addresses all this issues and this PFC has been realized on this context. The goal is to develop an XML-based information system for the collection and management of information from the technology and cell libraries developed in TDK4PE. This system will ease the treatment of that information for a later generation of specific Design Kits (DK) and the corresponding documentation. This work proposes a web application to generate technology files and design kits in a formatted way; it also proposes a structure for them and a database implementation for storing the needed information. The application will allow its users to redefine the structure of those files, as well as export and import XML files, between other formats.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Työn tavoitteena oli tehdä monikappalesysteemin esikäsittelijä, joka toimii CAD-ohjelmiston yhteydessä. CAD-ohjelmistoksi valittiin SolidWorks-ohjelmisto. Esikäsittelijästä tehtiin yhteensopiva monikappaledynamiikan simulointi ohjelmiston kanssa, joka on kehitetty Lappeenrannan teknillisessä yliopistossa. Aikaansaadun esikäsittelijän avulla pystytään tuottamaan monikappaledynamiikan simuloinnissa tarvittavat lähtötiedot. Lähtötiedot esikäsittelijä laskee käyttäjän tekemästä kokoonpanokuvasta ja käyttäjän antamista tiedoista. Esikäsittelijän toiminta verifioitiin kaupallisin simulointiohjelmisto ADAMS:n avulla. Esikäsittelijän todettiin toimivan luotettavasti ja täyttävän sille asetetut vaatimukset. Lisäksi esikäsittelijän todettiin nopeuttavan huomattavasti simulointimallien tekoa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Parametriset NURBS-käyrät ja -pinnat ovat yleisiä työkaluja graafisessa mallinnuksessa, tietokoneavusteisessa suunnittelussa ja muissa sovelluksissa. NURBS-mallinnus on pääosin melko intuitiivista, mutta siinä on joitakin vaikeammin ymmärrettäviä osia. Ihminen oppii parhaiten tekemällä, minkä takia päätettiin tehdä interaktiivinen NURBS-opetussovelma, joka tutustuttaa käyttäjän NURBSien toimintaan. Sovelma toimii www-selaimessa Java-liitännäisen avulla ja hyödyntää Java OpenGL -grafiikkarajapintaa kolmiulotteisen grafiikan piirtämiseen. Sovelma on helppokäyttöinen ja opastaa käyttäjää NURBS-mallinnuksen eri osa-alueissa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this thesis is to utilize the technology developed at LUT and to provide an easy tool for high-speed solid-rotor induction machine preliminary design. Computer aided design tool MathCAD has been chosen as the environment for realizing the calculation program. Four versions of the design program have been made depending on the motor rotor type. The first rotor type is an axially slitted solid-rotor with steel end rings. The next one is an axially slitted solid-rotor with copper end rings. The third machine type is a solid rotor with deep, rectangular copper bars and end rings (squirrel cage). And the last one is a solid-rotor with round copper bars and end rings (squirrel cage). Each type of rotor has its own specialties but a general thread of design is common. This paper follows the structure of the calculating program and explains some features and formulas. The attention is concentrated on the difference between laminated and solid-rotor machine design principles. There is no deep analysis of the calculation ways are presented. References for all solution methods appearing during the design procedure are given for more detailed studying. This thesis pays respect to the latest innovations in solid-rotor machines theory. Rotor ends’ analytical calculation follows the latest knowledge in this field. Correction factor for adjusting the rotor impedance is implemented. The purpose of the created design program is to calculate the preliminary dimensions of the machine according to initial data. Obtained results are not recommended for exact machine development. Further more detailed design should be done in a finite element method application. Hence, this thesis is a practical tool for the prior evaluating of the high-speed machine with different solid-rotor types parameters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This Master’s Thesis is dedicated to the simulation of new p-type pixel strip detector with enhanced multiplication effect. It is done for high-energy physics experiments upgrade such as Super Large Hadron Collider especially for Compact Muon Solenoid particle track silicon detectors. These detectors are used in very harsh radiation environment and should have good radiation hardness. The device engineering technology for developing more radiation hard particle detectors is used for minimizing the radiation degradation. New detector structure with enhanced multiplication effect is proposed in this work. There are studies of electric field and electric charge distribution of conventional and new p-type detector under reverse voltage bias and irradiation. Finally, the dependence of the anode current from the applied cathode reverse voltage bias under irradiation is obtained in this Thesis. For simulation Silvaco Technology Computer Aided Design software was used. Athena was used for creation of doping profiles and device structures and Atlas was used for getting electrical characteristics of the studied devices. The program codes for this software are represented in Appendixes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Dudding group is interested in the application of Density Functional Theory (DFT) in developing asymmetric methodologies, and thus the focus of this dissertation will be on the integration of these approaches. Several interrelated subsets of computer aided design and implementation in catalysis have been addressed during the course of these studies. The first of the aims rested upon the advancement of methodologies for the synthesis of biological active C(1)-chiral 3-methylene-indan-1-ols, which in practice lead to the use of a sequential asymmetric Yamamoto-Sakurai-Hosomi allylation/Mizoroki Heck reaction sequence. An important aspect of this work was the utilization of ortho-substituted arylaldehyde reagents which are known to be a problematic class of substrates for existing asymmetric allylation approaches. The second phase of my research program lead to the further development of asymmetric allylation methods using o-arylaldehyde substrates for synthesis of chiral C(3)-substituted phthalides. Apart from the de novo design of these chemistries in silico, which notably utilized water-tolerant, inexpensive, and relatively environmental benign indium metal, this work represented the first computational study of a stereoselective indium-mediated process. Following from these discoveries was the advent of a related, yet catalytic, Ag(I)-catalyzed approach for preparing C(3)-substituted phthalides that from a practical standpoint was complementary in many ways. Not only did this new methodology build upon my earlier work with the integrated (experimental/computational) use of the Ag(I)-catalyzed asymmetric methods in synthesis, it provided fundamental insight arrived at through DFT calculations, regarding the Yamamoto-Sakurai-Hosomi allylation. The development of ligands for unprecedented asymmetric Lewis base catalysis, especially asymmetric allylations using silver and indium metals, followed as a natural extension from these earlier discoveries. To this end, forthcoming as well was the advancement of a family of disubstituted (N-cyclopropenium guanidine/N-imidazoliumyl substituted cyclopropenylimine) nitrogen adducts that has provided fundamental insight into chemical bonding and offered an unprecedented class of phase transfer catalysts (PTC) having far-reaching potential. Salient features of these disubstituted nitrogen species is unprecedented finding of a cyclopropenium based C-H•••πaryl interaction, as well, the presence of a highly dissociated anion projected them to serve as a catalyst promoting fluorination reactions. Attracted by the timely development of these disubstituted nitrogen adducts my last studies as a PhD scholar has addressed the utility of one of the synthesized disubstituted nitrogen adducts as a valuable catalyst for benzylation of the Schiff base N-diphenyl methylene glycine ethyl ester. Additionally, the catalyst was applied for benzylic fluorination, emerging from this exploration was successful fluorination of benzyl bromide and its derivatives in high yields. A notable feature of this protocol is column-free purification of the product and recovery of the catalyst to use in a further reaction sequence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La maladie des artères périphériques (MAP) se manifeste par une réduction (sténose) de la lumière de l’artère des membres inférieurs. Elle est causée par l’athérosclérose, une accumulation de cellules spumeuses, de graisse, de calcium et de débris cellulaires dans la paroi artérielle, généralement dans les bifurcations et les ramifications. Par ailleurs, la MAP peut être causée par d`autres facteurs associés comme l’inflammation, une malformation anatomique et dans de rares cas, au niveau des artères iliaques et fémorales, par la dysplasie fibromusculaire. L’imagerie ultrasonore est le premier moyen de diagnostic de la MAP. La littérature clinique rapporte qu’au niveau de l’artère fémorale, l’écho-Doppler montre une sensibilité de 80 à 98 % et une spécificité de 89 à 99 % à détecter une sténose supérieure à 50 %. Cependant, l’écho-Doppler ne permet pas une cartographie de l’ensemble des artères des membres inférieurs. D’autre part, la reconstruction 3D à partir des images échographiques 2D des artères atteintes de la MAP est fortement opérateur dépendant à cause de la grande variabilité des mesures pendant l’examen par les cliniciens. Pour planifier une intervention chirurgicale, les cliniciens utilisent la tomodensitométrie (CTA), l’angiographie par résonance magnétique (MRA) et l’angiographie par soustraction numérique (DSA). Il est vrai que ces modalités sont très performantes. La CTA montre une grande précision dans la détection et l’évaluation des sténoses supérieures à 50 % avec une sensibilité de 92 à 97 % et une spécificité entre 93 et 97 %. Par contre, elle est ionisante (rayon x) et invasive à cause du produit de contraste, qui peut causer des néphropathies. La MRA avec injection de contraste (CE MRA) est maintenant la plus utilisée. Elle offre une sensibilité de 92 à 99.5 % et une spécificité entre 64 et 99 %. Cependant, elle sous-estime les sténoses et peut aussi causer une néphropathie dans de rares cas. De plus les patients avec stents, implants métalliques ou bien claustrophobes sont exclus de ce type d`examen. La DSA est très performante mais s`avère invasive et ionisante. Aujourd’hui, l’imagerie ultrasonore (3D US) s’est généralisée surtout en obstétrique et échocardiographie. En angiographie il est possible de calculer le volume de la plaque grâce à l’imagerie ultrasonore 3D, ce qui permet un suivi de l’évolution de la plaque athéromateuse au niveau des vaisseaux. L’imagerie intravasculaire ultrasonore (IVUS) est une technique qui mesure ce volume. Cependant, elle est invasive, dispendieuse et risquée. Des études in vivo ont montré qu’avec l’imagerie 3D-US on est capable de quantifier la plaque au niveau de la carotide et de caractériser la géométrie 3D de l'anastomose dans les artères périphériques. Par contre, ces systèmes ne fonctionnent que sur de courtes distances. Par conséquent, ils ne sont pas adaptés pour l’examen de l’artère fémorale, à cause de sa longueur et de sa forme tortueuse. L’intérêt pour la robotique médicale date des années 70. Depuis, plusieurs robots médicaux ont été proposés pour la chirurgie, la thérapie et le diagnostic. Dans le cas du diagnostic artériel, seuls deux prototypes sont proposés, mais non commercialisés. Hippocrate est le premier robot de type maitre/esclave conçu pour des examens des petits segments d’artères (carotide). Il est composé d’un bras à 6 degrés de liberté (ddl) suspendu au-dessus du patient sur un socle rigide. À partir de ce prototype, un contrôleur automatisant les déplacements du robot par rétroaction des images échographiques a été conçu et testé sur des fantômes. Le deuxième est le robot de la Colombie Britannique conçu pour les examens à distance de la carotide. Le mouvement de la sonde est asservi par rétroaction des images US. Les travaux publiés avec les deux robots se limitent à la carotide. Afin d’examiner un long segment d’artère, un système robotique US a été conçu dans notre laboratoire. Le système possède deux modes de fonctionnement, le mode teach/replay (voir annexe 3) et le mode commande libre par l’utilisateur. Dans ce dernier mode, l’utilisateur peut implémenter des programmes personnalisés comme ceux utilisés dans ce projet afin de contrôler les mouvements du robot. Le but de ce projet est de démontrer les performances de ce système robotique dans des conditions proches au contexte clinique avec le mode commande libre par l’utilisateur. Deux objectifs étaient visés: (1) évaluer in vitro le suivi automatique et la reconstruction 3D en temps réel d’une artère en utilisant trois fantômes ayant des géométries réalistes. (2) évaluer in vivo la capacité de ce système d'imagerie robotique pour la cartographie 3D en temps réel d'une artère fémorale normale. Pour le premier objectif, la reconstruction 3D US a été comparée avec les fichiers CAD (computer-aided-design) des fantômes. De plus, pour le troisième fantôme, la reconstruction 3D US a été comparée avec sa reconstruction CTA, considéré comme examen de référence pour évaluer la MAP. Cinq chapitres composent ce mémoire. Dans le premier chapitre, la MAP sera expliquée, puis dans les deuxième et troisième chapitres, l’imagerie 3D ultrasonore et la robotique médicale seront développées. Le quatrième chapitre sera consacré à la présentation d’un article intitulé " A robotic ultrasound scanner for automatic vessel tracking and three-dimensional reconstruction of B-mode images" qui résume les résultats obtenus dans ce projet de maîtrise. Une discussion générale conclura ce mémoire. L’article intitulé " A 3D ultrasound imaging robotic system to detect and quantify lower limb arterial stenoses: in vivo feasibility " de Marie-Ange Janvier et al dans l’annexe 3, permettra également au lecteur de mieux comprendre notre système robotisé. Ma contribution dans cet article était l’acquisition des images mode B, la reconstruction 3D et l’analyse des résultats pour le patient sain.