916 resultados para Carga e distribuição elétrica
Resumo:
To aureus α-HL channel, we used the cysteine-scanning mutagenesis technique. Twenty-four mutants were produced from the substitution of a single aminoacid of the primary structure of the α-HL pro this yzed after the incorporation of a mutant channel in planar lipid bilayer membranes. The modified proteins were studied in the absence and presence of watersoluble specific sulphydryl-specific reagents, in order to introduce a strong positive or negative harge at positions of substitution. The introduction of a negative charge in the stem region onverted the selectivity of the channel from weak anionic to more cationic. However, the troduction of a positive charge increased its selectivity to the anion. The degree of these alterations was inversely dependent on the channel radius at the position of the introduced harge (selectivity). As to the asymmetry of the conductance-voltage, the influence of the harge was more complex. The introduction of the negative charge in the stem region (the trans art of the pore) provoked a decrease. The intensity of these alterations depended on the radius, and on the type of free charge at the pore entrance. These results suggest that the free charge at surrounds the pore wall is responsible for the cation-anion selectivity of the channel. The istribution of the charges between the entrances is crucial for determining the asymmetry of e conductance-voltage curves. We hope that these results serve as a model for studies with other nanometric channels, in biological or planar lipid bilayer membranes or in iotechnological applications
Resumo:
Introduction: Chagas Disease is a serious public health problem, with 5 million infected individuals in Brazil. Of these, approximately 30% develop chronic Chagas cardiomyopathy (CCC), where the main symptoms are fatigue and dyspnea. Objective: To correlate maximal exercise capacity with pulmonary function, inspiratory muscle strength and quality of life in patients with CCC. Methodology: Twelve individuals suffering from CCC were evaluated (7 men), with a mean age of 54.91± 8.60 years and the following inclusion criteria: functional class II and III according to the New York Heart Association (NYHA); left ventricle ejection fraction below 45%; clinical stability (> 3 months); symptom duration > 1 year, body mass index (BMI) < 35Kg/m2 and non-smokers or ex-smokers with a history of smoking <10 packs/day. All subjects were submitted to spirometry, manometer testing, maximal cardiopulmonary exercise testing (CPX) and a quality of life questionnaire (Minnesota). Results: A negative correlation was observed between VO2máx and MLHFQ scores (r=-0.626; p=0.03) and a positive association with MIP (r=0.713; p=0.009). Positive correlations were also recorded between MIP and spirometric variables [FEV1(r=0.825;p=0.001 ), FVC(r=0.66;p=0.01 and FEF25-75%(r=0.639;p=0.02)]. Conclusion: The present study demonstrated that in patients with CCC: VO2MAX is directly related to inspiratory muscle strength and quality of life, while deteriorating lung function is directly associated with respiratory muscle weakness
Resumo:
Post dispatch analysis of signals obtained from digital disturbances registers provide important information to identify and classify disturbances in systems, looking for a more efficient management of the supply. In order to enhance the task of identifying and classifying the disturbances - providing an automatic assessment - techniques of digital signal processing can be helpful. The Wavelet Transform has become a very efficient tool for the analysis of voltage or current signals, obtained immediately after disturbance s occurrences in the network. This work presents a methodology based on the Discrete Wavelet Transform to implement this process. It uses a comparison between distribution curves of signals energy, with and without disturbance. This is done for different resolution levels of its decomposition in order to obtain descriptors that permit its classification, using artificial neural networks
Resumo:
In this work, we propose a solution to solve the scalability problem found in collaborative, virtual and mixed reality environments of large scale, that use the hierarchical client-server model. Basically, we use a hierarchy of servers. When the capacity of a server is reached, a new server is created as a sun of the first one, and the system load is distributed between them (father and sun). We propose efficient tools and techniques for solving problems inherent to client-server model, as the definition of clusters of users, distribution and redistribution of users through the servers, and some mixing and filtering operations, that are necessary to reduce flow between servers. The new model was tested, in simulation, emulation and in interactive applications that were implemented. The results of these experimentations show enhancements in the traditional, previous models indicating the usability of the proposed in problems of all-to-all communications. This is the case of interactive games and other applications devoted to Internet (including multi-user environments) and interactive applications of the Brazilian Digital Television System, to be developed by the research group. Keywords: large scale virtual environments, interactive digital tv, distributed
Resumo:
The objective of the present work is develop a model to simulate electrical energy networks in transient and stead states, using the software ATP (Alternative Transient Program), able to be a way to join two distinct themes, present in classical methodology planning networks: short circuit analysis and load flow theory. Beyond that, using a tool for relay simulation, this paper intend to use the new developed model to investigate the influence of transient phenomenon in operation of protection relays, and calibrate the enterprise's protections relays. For testing the model, some relays, actually, installed at COSERN were used
Resumo:
This work has as main objective to show all the particularities regarding the Three-phase Power Summation Method, used for load flow calculation, in what it says respect to the influence of the magnetic coupling among the phases, as well as to the losses presented in all the existent transformers in the feeder to be analyzed. Besides, its application is detailed in the study of the short-circuits, that happen in the presence of high impedance values, which possess a problem, that is its difficult detection and consequent elimination on the part of common devices of protection. That happens due to the characteristic presented by the current of short¬ circuit, in being generally of the same order of greatness that the load currents. Results of simulations accomplished in several situations will be shown, objectifying a complete analysis of the behavior of the proposed method in several types of short-circuits. Confront of the results obtained by the method with results of another works will be presented to verify its effectiveness
Resumo:
This works presents a proposal to make automatic the identification of energy thefts in the meter systems through Fuzzy Logic and supervisory like SCADA. The solution we find by to collect datas from meters at customers units: voltage, current, power demand, angles conditions of phasors diagrams of voltages and currents, and taking these datas by fuzzy logic with expert knowledge into a fuzzy system. The parameters collected are computed by fuzzy logic, in engineering alghorithm, and the output shows to user if the customer researched may be consuming electrical energy without to pay for it, and these feedbacks have its own membership grades. The value of this solution is a need for reduce the losses that already sets more than twenty per cent. In such a way that it is an expert system that looks for decision make with assertivity, and it looks forward to find which problems there are on site and then it wont happen problems of relationship among the utility and the customer unit. The database of an electrical company was utilized and the datas from it were worked by the fuzzy proposal and algorithm developed and the result was confirmed
Resumo:
This work develops a methodology for defining the maximum active power being injected into predefined nodes in the studied distribution networks, considering the possibility of multiple accesses of generating units. The definition of these maximum values is obtained from an optimization study, in which further losses should not exceed those of the base case, i.e., without the presence of distributed generation. The restrictions on the loading of the branches and voltages of the system are respected. To face the problem it is proposed an algorithm, which is based on the numerical method called particle swarm optimization, applied to the study of AC conventional load flow and optimal load flow for maximizing the penetration of distributed generation. Alternatively, the Newton-Raphson method was incorporated to resolution of the load flow. The computer program is performed with the SCILAB software. The proposed algorithm is tested with the data from the IEEE network with 14 nodes and from another network, this one from the Rio Grande do Norte State, at a high voltage (69 kV), with 25 nodes. The algorithm defines allowed values of nominal active power of distributed generation, in percentage terms relative to the demand of the network, from reference values
Resumo:
The opening of the Brazilian market of electricity and competitiveness between companies in the energy sector make the search for useful information and tools that will assist in decision making activities, increase by the concessionaires. An important source of knowledge for these utilities is the time series of energy demand. The identification of behavior patterns and description of events become important for the planning execution, seeking improvements in service quality and financial benefits. This dissertation presents a methodology based on mining and representation tools of time series, in order to extract knowledge that relate series of electricity demand in various substations connected of a electric utility. The method exploits the relationship of duration, coincidence and partial order of events in multi-dimensionals time series. To represent the knowledge is used the language proposed by Mörchen (2005) called Time Series Knowledge Representation (TSKR). We conducted a case study using time series of energy demand of 8 substations interconnected by a ring system, which feeds the metropolitan area of Goiânia-GO, provided by CELG (Companhia Energética de Goiás), responsible for the service of power distribution in the state of Goiás (Brazil). Using the proposed methodology were extracted three levels of knowledge that describe the behavior of the system studied, representing clearly the system dynamics, becoming a tool to assist planning activities
Resumo:
Com o objetivo de avaliar a deposição e distribuição de solução traçante em plantas de feijoeiro e capim-braquiária, foi conduzido experimento no NuPAM-FCA/ UNESP, campus de Botucatu-SP, utilizando um simulador de pulverização em ambiente controlado. Os tratamentos utilizados foram: bico jato plano XR Teejet (XR110.02VS) + surfactante Aterbane BR (0,5% v/v); bico jato cônico Conejet (TXVK-4) + surfactante Aterbane BR (0,5% v/v); bico jato plano XR Teejet (XR110.02VS); e bico jato cônico Conejet (TXVK-4). em todos os tratamentos foi aplicada uma solução de NaCl (0,5% p/v) + corante Poliglow laranja (0,5% p/v) + mancozeb (0,5% p/v). As unidades experimentais constituíram-se de vasos com duas plantas-alvo de capim-braquiária posicionadas sob uma planta-alvo de feijoeiro. A visualização da distribuição das gotas nas folhas de capim-braquiária foi efetuada com auxílio de luz negra, e o depósito da calda na superfície das plantas foi quantificado através da condutividade elétrica da solução aplicada e coletada por meio de lavagem de ambos os alvos. Os bicos de pulverização, jato plano (XR Teejet) e cônico (Conejet), não apresentaram diferença no depósito nos folíolos totais de feijoeiro quando submetidos a mesma condição de calda de pulverização. No entanto, o bico jato plano XR Teejet (XR110.02VS) e o bico jato cônico Conejet (TXVK-4) proporcionaram aumento de 67,1 e 61,5% na deposição da calda em relação a área foliar e 106,4 e 66,9% para matéria seca, respectivamente, em relação ao bico jato plano XR Teejet (XR110.02VS) + surfactante Aterbane BR (0,5% v/v) e ao bico jato cônico Conejet (TXVK-4) + surfactante Aterbane BR (0,5% v/v). Para o capim-braquiária, o bico cônico Conejet proporcionou deposição superior e distribuição mais uniforme em relação ao jato plano XR Teejet.
Resumo:
Este artigo apresenta os principais resultados e o detalhamento da metodologia e equações de controle de um retificador monofásico pré-regulador de 150kW para sistema trólebus. A estrutura proposta possibilita a Correção ativa do Fator de Potência (CFP) com baixos níveis de Distorção Harmônica Total (DHT) na corrente, em conformidade com a norma internacional IEC 61000-3-4. Fruto de um projeto de Pesquisa, Desenvolvimento e Inovação (P) junto à empresa AES Eletropaulo Metropolitana de São Paulo, em parceria com a empresa de transporte Himalaia S.A., o projeto possui como principais objetivos estimular o interesse para a expansão das linhas de trólebus a partir de uma plataforma de alimentação de menor custo de instalação e manutenção, sem a necessidade de subestações retificadoras, e, com vistas a promover a melhoria da qualidade de vida nos grandes centros urbanos. Nessa nova modalidade proposta para o sistema de alimentação, o trólebus pode ser alimentado tanto pelas redes convencionais em corrente contínua (CC) quanto pelas redes de distribuição em corrente alternada (CA), mantendo-se a disposição a dois fios dos sistemas CC, sendo as mudanças de rede de alimentação (CC ou CA) monitoradas e controladas digitalmente. Todo o sistema de gerenciamento e controle do conversor é realizado digitalmente por FPGA XC3S200. Na evolução do sistema proposto, os autores pretendem inclusive eliminar as linhas aéreas de alimentação, através da utilização de postos de alimentação em CA, especialmente desenvolvidos para os pontos de embarque/desembarque de passageiros para este veículo de transporte coletivo, eliminando-se os aspectos visuais negativos das redes de alimentação deste modal, e, reduzindo-se as falhas de operação do sistema.
Resumo:
This work presents results derived from a study related to impact on non-controllable costs in the determination of energy taxes. This is done analyzing tax review practiced by concessionaries responsible for the distribution of electrical energy located in the Northeastern Region of Brazil, between 2003 and 2004. This Region was chosen as a study area due to the researcher s expectation in congregating companies that deliver services to markets that have similar social-economical profiles. A brief explanation related to the restructuring of the electrical sector in Brazil is presented, pointing out that there was privatization of the great majority of these companies. The study also points out the definition of regulating rules in service delivery process. The components of taxes that are practiced by these companies aimed at final consumers, as well as the market as a whole and the revision process that is executed by Agência Nacional de Energia Elétrica ANEEL for the definition of these taxes are demonstrated in the research. A brief historical of the concessionaires that were focus of the research is presented, totaling five companies. Some data used by ANEEL in the tax review process was analyzed as well as data on components of approved taxes. It is concluded that as a media 47, 49% of the components of taxes in the researched companies correspond to the non-controllable costs. These is done considering previous classification by ANEEL in the tax review process. Although, if it is considered that these companies since 2006, by the means of participation in energy auctions are able to negotiate energy prices for their own needs, it is concluded that these concession contracts guarantee the delivery of the service to the costumer in the total tribute. The percentage of non-controllable costs is 16, 27% average of the tax. This means, amongst other information, that the government has a great deal of responsibility in the formation of price practiced by these companies and its target markets
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Resumo:
The main factors that influence the species distribution are related mainly with the dispersion capacity, behavior, presence of other species and to the factors physicist-chemistries. Had been evaluated ecological factors that affect the distribution of the genus Astyanax in Chapada dos Guimaraes headstreams, Cuiaba River basin, Mato Grosso, Brazil. Samples in 27 streams had been made in Chapada dos Guimaraes, and the fish had been collected through the method of electric fish, and the ambient data had been analyzed with one technique of called ordinance of Principal Components Analysis (PCA). 250 individuals had been collect, being 95 A. asuncionensis, 62 A. abramis, 36 A. lineatus and 57 individuals had been captured identified like A. scabripinnis (Jenyns, 1842) sensu Eigenmann, 1927. In relation the ambient characteristics, the variables gotten allowed two axes of the PCA, who explain 53,114 % of the variance of the seven variables analyzed. Axle 1, Main Component 1, explained 31,147 % and Axle 2, Main Component 2, explained 21,967 % of the variation of the ambient data. The formation of axle 1 was influenced positively by the depth and negative by the conductivity and pH. The formation of axle 2 was influenced positively by the Turbidity and negative to the Dissolved Oxygen. The ordinance of the species throughout for the axes corroborated for the understanding of the distribution of specimens.