828 resultados para Carbon steel electrodes
Resumo:
For the first time, the electrochemistry of gold has been studied in detail in a 'second-generation', non-haloaluminate, ionic liquid. In particular, the electrochemical behaviour of Na[AuCl4] has been investigated in 1-butyl-3-methylimidazolium bis{(tifluoromethyl)sulfonyl} imide, [C(4)mim][NTf2], over gold, platinum and glassy carbon working electrodes. The reduction of [AuCl4](-) initially forms [AuCl2](-) before deposition on the electrode as Au(0). To enable stripping of deposited gold or electrodissolution of bulk gold, the presence of chloride, trichloride or chlorine is required. Specifically trichloride and chlorine have been identified as the active species which preferentially form Au(I) and Au(III), respectively.
Resumo:
The electrochemical reduction of oxygen is reported in four room temperature ionic liquids (RTILs) based on quaternary alkyl -onium cations and heavily fluorinated anions in which the central atom is either nitrogen or phosphorus. Data were collected using cyclic voltammetry and potential step chronoamperometry at gold, platinum, and glassy carbon disk electrodes of micrometer dimension under water-free conditions at a controlled temperature. Analysis via fitting, to appropriate theoretical equations was then carried out to obtain kinetic and thermodynamic information pertaining to the electrochemical processes observed. In the quaternary ammonium electrolytes, reduction of oxygen was found to occur reversibly to give stable superoxide, in an analogous manner to that seen in conventional aprotic solvents such as dimethyl sufoxide and acetonitrile. The most significant difference is in the relative rate of diffusion; the diffusion coefficients of oxygen in the RTILs are an order of magnitude lower than in common organic solvents, and for superoxide these values are reduced by a further factor of 10. In the quaternary phosphonium ionic liquids, however, more complex voltammetry is observed, akin to that expected for the reduction of oxygen in acidified organic media. This is shown to be consistent with the occurrence of a proton abstraction reaction between the electrogenerated superoxide and quaternary alkyl phosphonium cations following the initial electron transfer.
Resumo:
An electrochemical double layer capacitor test cell containing activated carbon xerogel electrodes and ionic liquid electrolyte was tested at 15, 25 and 40 OC to examine the effect of temperature on electrolyte resistance (RS) and equivalent series resistance (ESR) measured using impedance spectroscopy and capacitance using charge/discharge cycling. A commercial 10F capacitor was used as a comparison. Viscosity, ionic self-diffusion coefficients and differential scanning calorimetry measurements were used to provide an insight into the behaviour of the 1,2-dimethyl-3-propylimdazolium electrolyte. Both RS and ESR decreased with increasing temperature for both capacitors. Increasing the temperature also increased the capacitance for both the test cell and the commercial capacitor but proportionally more for the test cell. An increase in temperature decreased the ionic liquid electrolyte viscosity and increased the self diffusion coefficients of both the anion and the cation indicating an increase in dissociation and increase in ionic mobility.
Resumo:
O tratamento físico-químico de águas residuais, de origem industrial, mais comum é o tratamento baseado na adição de coagulante e floculante a um efluente. No entanto, o tratamento eletroquímico é um tipo de tratamento que tem vindo a ser explorado e estudado com mais ênfase ao longo dos últimos anos. O tratamento eletroquímico é uma tecnologia AOP (Processos de Oxidação Avançada) e divide-se em eletrólise direta (oxidação e redução) e indireta (eletrocoagulação-flotação e eletrooxidação). A eletrocoagulação e eletrooxidação divergem apenas pelo tipo de reações que ocorrem, devido ao material que constitui os elétrodos. São processos complexos com uma multiplicidade de mecanismos que operam sinergicamente para remover poluentes da água. Tendo em conta a sua complexidade e ainda dificuldade de compreensão, existem na literatura diferentes versões acerca de quais os mecanismos chave, assim como diversas configurações geométricas de reatores e elétrodos. Atualmente, este tipo de tratamento tem vindo a evoluir, tornando-se num método economicamente viável para o tratamento de uma grande variedade de águas residuais, nomeadamente, aquelas que possuem compostos recalcitrantes na sua composição. O presente trabalho foi realizado nas instalações da VentilAQUA S.A. e, tendo em conta a sua área de especialidade, o trabalho exposto focou-se no desenvolvimento de soluções técnicas de AOP, nomeadamente na área eletroquímica (eletrocoagulação e eletrooxidação),para estudo dos parâmetros operacionais numa nova configuração geométrica para os elétrodos. Tendo por base os contributos da revisão bibliográfica, o estudo incidiu num reator tubular, com elétrodos de inox dispostos de forma concêntrica, à mesma distância entre si. Com este reator foram executados variados testes, com diferentes efluentes, que permitiram obter resultados operacionais de otimização de funcionamento, tendo em vista a remoção de poluentes. O estudo financeiro associado permitiu concluir que a eletrooxidação é significativamente mais económica que o tratamento físico-químico, nas condições operacionais e para os efluentes tratados. Relativamente ao Acompanhamento e Gestão de ETAR’s (Capítulo 4) foi possível verificar que todos os casos em estudo apresentam uma boa eficiência de remoção de matéria orgânica, permitindo a descarga do seu efluente com uma carga poluente que cumpre com os requisitos legais de descarga em meio hídrico.
Resumo:
The present work reports studies on the new compounds obtained by the combination of polyoxoanions derived from the Keggin and Lindquist structures with several cations. The studies were first focused on the monolacunary Keggin polyoxoanions [PW11O39M(H2O)]n- (M = FeIII, MnIII and n = 4; M = CoII and n = 5) and its combination with the organic cation 1-butyl-3-methylimidazolium (Bmim+). The association of Bmim+ cation with the polyoxoanion [PW11O39Fe(H2O)]4- allowed to isolate for the first time both the monomeric and the dimeric [PW11O39Fe)2O]10- anions, with the same cation and using simple bench techniques by pH manipulation. Studies regarding the stability of these inorganic species in solution indicated that both species are present in solution in equilibrium. However, the inability to up until now isolate the dimeric unit through simple bench methods, lead to the hypothesis that the cation had a role to play in the selective precipitation of either the monomer or the dimer. Repetition of the same procedures with the polyoxoanions [SiW11O39Fe(H2O)]5- and [PW11O39M(H2O)]n- (M = FeIII, MnIII and n = 4; M = Co and n = 5), afforded only the corresponding monomeric compounds, (Bmim)5[SiW11O39FeIII(H2O)]· 4H2O (3), (Bmim)5[PW11O39CoII(H2O)]· 0.5 H2O, (4) and (Bmim)5[PW11O39MnIII(H2O)]· 0.5 H2O (5). Moreover, the combination of Bmim+ and the polyoxotungstate [PW11O39Co(H2O)]5- afforded two different crystal structures, depending on the synthetic conditions. Thus, a ratio Bmim+:POM of 5:1 and the presence of K+ cations (due to addition of KOH) led to a formula Na2K(Bmim)2[PW11.2O39Co0.8(H2O)]·7H2O (4a), whilst a ratio Bmim:POM of 7:1 led to the formation of a crystal with the chemical formula Na2(Bmim)8[PW11O39Co(H2O)]2·3H2O (4b). Electrochemical studies were performed with carbon paste electrodes modified with BmimCl to investigate the influence of the Bmim+ cation in the performance of the electrodes. The voltametric measurements obtained from solutions containing the anions [PW11O39]7- and [SiW11O39]8- are presented. Results pointed to an improvement of the acquired voltametric signal with a slight addition of BmimCl (up to 2.5% w/w), specially in the studies regarding pH variation. Additional synthesis were carried out with both the cations Omim+ and THTP+.
Resumo:
This work reports one possible way to develop new functional coatings used to increase the life time of metallic structures. The functionalities selected and attributed to model coatings in the frame of this work were corrosion protection, self-sensing and prevention of fouling (antifouling). The way used to confer those functionalities to coatings was based on the encapsulation of active compounds (corrosion inhibitors, pH indicators and biocides) in micro and nanocontainers followed by their incorporation into the coating matrices. To confer active corrosion protection, one corrosion inhibitor (2-mercaptobenzothiazole, MBT) was encapsulated in two different containers, firstly in silica nanocapsules (SiNC) and in polyurea microcapsules (PU-MC). The incorporation of both containers in different models coatings shows a significant improvement in the corrosion protection of aluminum alloy 2024 (AA2024). Following the same approach, SiNC and PU-MC were also used for the encapsulation of phenolphthalein (one well known pH indicator) to introduce sensing properties in polymeric coatings. SiNC and PU-MC containing phenolphthalein acted as corrosion sensor, showing a pink coloration due to the beginning of cathodic reaction, resulting in a pH increase identified by those capsules. Their sensing performance was proved in suspension and when integrated in coatings for aluminium alloy 2024 and magnesium alloy AZ31. In a similar way, the biocide activity (antifouling) was assigned to two polymeric matrices using SiNC for encapsulation of one biocide (Dichloro-2-octyl-2H-isothiazol-3-one, DCOIT) and also SiNC-MBT was tested as biocide. The antifouling activity of those two encapsulated compounds was assessed through inhibition and consequent decrease in the bioluminescence of modified E. coli. That effect was verified in suspension and when incorporated in coatings for AISI 1008 carbon steel. The developed micro and nanocontainers presented the desired performance, allowing the introduction of new functionalities to model coatings, showing potential to be used as functional additives in the next generation of multifunctional coatings.
Resumo:
Reactive oxygen species (ROS) are produced as a consequence of normal aerobic metabolism and are able to induce DNA oxidative damage. At the cellular level, the evaluation of the protective effect of antioxidants can be achieved by examining the integrity of the DNA nucleobases using electrochemical techniques. Herein, the use of an adenine-rich oligonucleotide (dA21) adsorbed on carbon paste electrodes for the assessment of the antioxidant capacity is proposed. The method was based on the partial damage of a DNA layer adsorbed on the electrode surface by OH• radicals generated by Fenton reaction and the subsequent electrochemical oxidation of the intact adenine bases to generate an oxidation product that was able to catalyze the oxidation of NADH. The presence of antioxidant compounds scavenged hydroxyl radicals leaving more adenines unoxidized, and thus, increasing the electrocatalytic current of NADHmeasured by differential pulse voltammetry (DPV). Using ascorbic acid (AA) as a model antioxidant species, the detection of as low as 50nMof AA in aqueous solution was possible. The protection efficiency was evaluated for several antioxidant compounds. The biosensor was applied to the determination of the total antioxidant capacity (TAC) in beverages.
Resumo:
The integrity of DNA purine bases was herein used to evaluate the antioxidant capacity. Unlike other DNA-based antioxidant sensors reported so far, the damaging agent chosen was the O 2 radical enzymatically generated by the xanthine/xanthine oxidase system. An adenine-rich oligonucleotide was adsorbed on carbon paste electrodes and subjected to radical damage in the presence/absence of several antioxidant compounds. As a result, partial damage on DNA was observed. A minor product of the radical oxidation was identified by cyclic voltammetry as a diimine adenine derivative also formed during the electrochemical oxidation of adenine/guanine bases. The protective efficiency of several antioxidant compounds was evaluated after electrochemical oxidation of the remaining unoxidized adenine bases, by measuring the electrocatalytic current of NADH mediated by the adsorbed catalyst species generated. A comparison between O 2 and OH radicals as a source of DNA lesions and the scavenging efficiency of various antioxidant compounds against both of them is discussed. Finally, the antioxidant capacity of beverages was evaluated and compared with the results obtained with an optical method.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
The fabrication and analytical applications of two types of potentiometric sensors for the determination of ketoconazole (KET) are described. The sensors are based on the use of KET-molybdophosphoric acid (MPA) ion pair as electroactive material. The fabricated sensors include both polymer membrane and carbon paste electrodes. Both sensors showed a linear, stable and near Nernstian slope of 57.8mV=decade and 55.2mV=decade for PVC membrane and carbon paste sensors respectively over a relatively wide range of KET concentration (1×10-2-5×10-5 and 1×10-2-1×10-6). The sensors showed a fast response time of <30 sec and <45 sec. A useful pH range of 3–6 was obtained for both types of sensors. A detection limit of 2.96 10 5M was obtained for PVC membrane sensor and 6.91 10 6M was obtained for carbon paste sensor. The proposed sensors proved to have a good selectivity for KET with respect to a large number of ions. The proposed sensors were successfully applied for the determination of KET in pharmaceutical formulations. The results obtained are in good agreement with the values obtained by the standard method.
Resumo:
La industria metalúrgica a nivel mundial es considerada como el segundo clúster más grande y emplea aproximadamente setenta millones de personas sumando los sectores que se mueven en esta industria no formalizados. Igualmente genera el segundo PIB más grande en el mundo después de la industria petrolera. Además, en el panorama nacional, es una industria con un alto desarrollo , crecimiento acelerado y de grandes aportes económicos al país, tanto en materia de empleo como en desarrollo infraestructural, siendo de los principales sectores con mayor contribución en el país aportando un 9% de PIB. De acuerdo a esto se realizó un estudio que permitirá conocer el desarrollo de esta industria en Colombia y evaluar su infraestructura logística, ya que se puede percibir un importante potencial en esta industria debido a la necesidad y alta demanda del acero como materia prima; así como su contribución al desarrollo económico en Colombia. En este documento se apreciara la estructura de la cadena de suministros del acero, se describirá el clúster, se interpretaran datos reales de producción, ventas y exportaciones. Igualmente se estudiarán las percepciones del gremio y sus propuestas de crecimiento, las influencias políticas y económicas que inciden en la operación de esta industria. De acuerdo a esto, el interés es que mediante este proyecto de investigación se realice un estudio de la situación actual de la industria del acero en Colombia, identificando sus competencias, elementos para implementar y la infraestructura necesaria para estar al nivel de los principales competidores a nivel mundial.
Resumo:
16S rRNA gene sequencing was used to identify a sulfate-reducing bacterium (SRB) from a Danish North Sea oilfield water injection system. This species was cultivated, purified and subsequently identified as being >97% similar to Desulfovibrio gracilis. Like some other Desulfovibrio species this SRB, strain OP102, could reduce nitrate as an electron acceptor and produce ammonia in the absence of sulfate. In addition, in the presence of sulfate, when nitrate was dosed at 100 mg/l it was again reduced by the bacterium, with some ammonium production. Therefore, this mechanism could be important in oilfield systems where nitrate is applied to prevent sulfide generation by SRB which leads to reservoir souring. In static tests the influence of this Desulfovibrio on corrosion was assessed using carbon steel coupons, in the presence of sulfate and in the presence of sulfate with 100 mg/l nitrate. Corrosion rates were less than 1.5 mpy when coupons were incubated in the same water, with sulfate and with nitrate. Furthermore, the occurrence of pitting corrosion was fairly low under all circumstances.
Resumo:
This study describes the development of amperometric sensors based on poly(allylamine hydrochloride) (PAH) and lutetium bisphthalocyanine (LuPc(2)) films assembled using the Layer-by-Layer (LbL) technique. The films have been used as modified electrodes for catechol quantification. Electrochemical measurements have been employed to investigate the catalytic properties of the LuPc(2) immobilized in the LbL films. By chronoamperometry, the sensors present excellent sensitivity (20 nA mu M(-1)) in a wide linear range (R(2) = 0.994) up to 900 mu M and limit of detection (s/n = 3) of 37.5 x 10(-8) M for catechol. The sensors have good reproducibility and can be used at least for ten times. The work potential is +0.3 V vs. saturated calomel electrode (SCE). In voltammetry measurements, the calibration curve shows a good linearity (R(2) = 0.992) in the range of catechol up to 500 mu M with a sensitivity of 90 nA mu M(-1) and LD of 8 mu M. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Electrodeposition of bismuth on gold microelectrodes for determination of Pb(II) by square wave anodic stripping voltammetry (SWASV) was accomplished by an in situ procedure in alkaline solution. A linear calibration plot for Pb(II) in the concentration range 40 to 6700 nmol L(-1) (r=0.998) was obtained, the detection limit was found to be 12.5 nmol L(-1) (S/N = 3) and the relative standard deviation in Solutions containing 1 mu mol L(-1) Pb(II) was 4% (n = 12). The analytical performance of the proposed sensor wits tested by measuring the Pb(II) concentration in a wine sample. The result Was in good agreement with the one obtained by GFAAS.
Resumo:
Composite electrodes were prepared using graphite powder and silicone rubber in different compositions. The use of such hydrophopic materials interned to diminish the swallowing observed in other cases when the electrodes are used in aqueous solutions for a long time. The composite was characterized for the response reproducibility, ohmic resistance, thermal behavior and active area. The voltammetric response in relation to analytes with known voltammetric behavior was also evaluated, always in comparison with the glassy carbon. The 70% (graphite, w/w) composite electrode was used in the quantitative determination of hydroquinone (HQ) in a DPV procedure in which a detection limit of 5.1 x 10(-8) mol L-1 was observed. HQ was determined in a photographic developer sample with errors lower then 1% in relation to the label value. (c) 2007 Elsevier B.V. All rights reserved.