975 resultados para Biodegradable Medical Devices


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Biofilms are multicellular bacterial structures that adhere to surfaces and often endow the bacterial population with tolerance to antibiotics and other environmental insults. Biofilms frequently colonize the tubing of medical devices through mechanisms that are poorly understood. Here we studied the helicoidal spread of Pseudomonas putida biofilms through cylindrical conduits of varied diameters in slow laminar flow regimes. Numerical simulations of such flows reveal vortical motion at stenoses and junctions, which enhances bacterial adhesion and fosters formation of filamentous structures. Formation of long, downstream-flowing bacterial threads that stem from narrowings and connections was detected experimentally, as predicted by our model. Accumulation of bacterial biomass makes the resulting filaments undergo a helical instability. These incipient helices then coarsened until constrained by the tubing walls, and spread along the whole tube length without obstructing the flow. A three-dimensional discrete filament model supports this coarsening mechanism and yields simulations of helix dynamics in accordance with our experimental observations. These findings describe an unanticipated mechanism for bacterial spreading in tubing networks which might be involved in some hospital-acquired infections and bacterial contamination of catheters.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Biofilms are the primary cause of clinical bacterial infections and are impervious to typical amounts of antibiotics, necessitating very high doses for treatment. Therefore, it is highly desirable to develop new alternate methods of treatment that can complement or replace existing approaches using significantly lower doses of antibiotics. Current standards for studying biofilms are based on end-point studies that are invasive and destroy the biofilm during characterization. This dissertation presents the development of a novel real-time sensing and treatment technology to aid in the non-invasive characterization, monitoring and treatment of bacterial biofilms. The technology is demonstrated through the use of a high-throughput bifurcation based microfluidic reactor that enables simulation of flow conditions similar to indwelling medical devices. The integrated microsystem developed in this work incorporates the advantages of previous in vitro platforms while attempting to overcome some of their limitations. Biofilm formation is extremely sensitive to various growth parameters that cause large variability in biofilms between repeated experiments. In this work we investigate the use of microfluidic bifurcations for the reduction in biofilm growth variance. The microfluidic flow cell designed here spatially sections a single biofilm into multiple channels using microfluidic flow bifurcation. Biofilms grown in the bifurcated device were evaluated and verified for reduced biofilm growth variance using standard techniques like confocal microscopy. This uniformity in biofilm growth allows for reliable comparison and evaluation of new treatments with integrated controls on a single device. Biofilm partitioning was demonstrated using the bifurcation device by exposing three of the four channels to various treatments. We studied a novel bacterial biofilm treatment independent of traditional antibiotics using only small molecule inhibitors of bacterial quorum sensing (analogs) in combination with low electric fields. Studies using the bifurcation-based microfluidic flow cell integrated with real-time transduction methods and macro-scale end-point testing of the combination treatment showed a significant decrease in biomass compared to the untreated controls and well-known treatments such as antibiotics. To understand the possible mechanism of action of electric field-based treatments, fundamental treatment efficacy studies focusing on the effect of the energy of the applied electrical signal were performed. It was shown that the total energy and not the type of the applied electrical signal affects the effectiveness of the treatment. The linear dependence of the treatment efficacy on the applied electrical energy was also demonstrated. The integrated bifurcation-based microfluidic platform is the first microsystem that enables biofilm growth with reduced variance, as well as continuous real-time threshold-activated feedback monitoring and treatment using low electric fields. The sensors detect biofilm growth by monitoring the change in impedance across the interdigitated electrodes. Using the measured impedance change and user inputs provided through a convenient and simple graphical interface, a custom-built MATLAB control module intelligently switches the system into and out of treatment mode. Using this self-governing microsystem, in situ biofilm treatment based on the principles of the bioelectric effect was demonstrated by exposing two of the channels of the integrated bifurcation device to low doses of antibiotics.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To study the prevalence of resistant strains of Staphylococcus aureus isolated from surfaces, beds and various equipment of an Iranian hospital emergency ward. Methods: Two hundred swab samples were collected from the surfaces, beds, trolleys, surgical equipment and diagnostic medical devices in emergency ward. Samples were cultured and those that were S. aureus-positive were confirmed using polymerase chain reaction (PCR). Antimicrobial resistance pattern was analyzed using disk diffusion method. Results: Nine of 200 samples (4.5 %) collected were positive for S. aureus. Surfaces (8.8 %), beds (5 %) and trolleys (5 %) were the most commonly contaminated. S. aureus isolates exhibited varying levels of resistance against antibiotics with the following being the highest: tetracycline (88.8 %), penicillin (88.8 %) and ampicillin (77.7 %). The prevalence of resistance against methicillin, oxacillin and azithromycin were 44.4, 33.3 and 33.3 %, respectively. There was no pattern of resistance against imipenem. Conclusion: Efficient disinfection of surfaces, beds, trolleys and surgical instruments should be performed periodically to reduce colonization of resistant strains of S. aureus in various areas of emergency health care centers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This dissertation investigates de role of the new additive manufacturing techniques in the treatment of pathologies with a patient-specific approach. Throughout this work the development methodology of these said products is explained in order to understand the different stages required to achieve a tailor made solution. The goal is to demonstrate the importance of the manufacturing technique and its capabilities to tailor-fit devices to patients and the adaptability of the process to tackle the most diverse situations. Three real cases are documented in order to prove the viability of the method and to showcase its advantages. Whenever possible patient-specific solutions are compared to their “off-the-shelf” counterparts in order to establish the pros and cons of each one of them. The dissertation is an insight into a possible future for the medical devices industry, where customization is expected to be the standard approach in the treatment of patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this research study is to discuss privacy and data protection-related regulatory and compliance challenges posed by digital transformation in healthcare in the wake of the COVID-19 pandemic. The public health crisis accelerated the development of patient-centred remote/hybrid healthcare delivery models that make increased use of telehealth services and related digital solutions. The large-scale uptake of IoT-enabled medical devices and wellness applications, and the offering of healthcare services via healthcare platforms (online doctor marketplaces) have catalysed these developments. However, the use of new enabling technologies (IoT, AI) and the platformisation of healthcare pose complex challenges to the protection of patient’s privacy and personal data. This happens at a time when the EU is drawing up a new regulatory landscape for the use of data and digital technologies. Against this background, the study presents an interdisciplinary (normative and technology-oriented) critical assessment on how the new regulatory framework may affect privacy and data protection requirements regarding the deployment and use of Internet of Health Things (hardware) devices and interconnected software (AI systems). The study also assesses key privacy and data protection challenges that affect healthcare platforms (online doctor marketplaces) in their offering of video API-enabled teleconsultation services and their (anticipated) integration into the European Health Data Space. The overall conclusion of the study is that regulatory deficiencies may create integrity risks for the protection of privacy and personal data in telehealth due to uncertainties about the proper interplay, legal effects and effectiveness of (existing and proposed) EU legislation. The proliferation of normative measures may increase compliance costs, hinder innovation and ultimately, deprive European patients from state-of-the-art digital health technologies, which is paradoxically, the opposite of what the EU plans to achieve.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We introduce biomimetic in silico devices, and means for validation along with methods for testing and refining them. The devices are constructed from adaptable software components designed to map logically to biological components at multiple levels of resolution. In this report we focus on the liver; the goal is to validate components that mimic features of the lobule (the hepatic primary functional unit) and dynamic aspects of liver behavior, structure, and function. An assembly of lobule-mimetic devices represents an in silico liver. We validate against outflow profiles for sucrose administered as a bolus to isolated, perfused rat livers. Acceptable in silico profiles are experimentally indistinguishable from those of the in situ referent. This new technology is intended to provide powerful Dew tools for challenging our understanding of how biological functional units function in vivo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: We tested two novel drug-eluting stents (DES), covered with a biodegradable-polymer carrier and releasing paclitaxel or sirolimus, which were compared against a bare metal stent (primary objective). The DES differed by the drug, but were identical otherwise, allowing to compare the anti-restenosis effects of sirolimus versus paclitaxel (secondary objective). Background: The efficacy of novel DES with biodegradable polymers should be tested in the context of randomized trials, even when using drugs known to be effective, such as sirolimus and paclitaxel. Methods: Overall, 274 patients with de novo coronary lesions in native vessels scheduled for stent implantation were randomly assigned (2:21 ratio) for the paclitaxel (n = 111), sirolimus (n = 106), or bare metal stent (n = 57) groups. Angiographic follow-up was obtained at 9 months and major cardiac adverse events up to 12 months. Results: Both paclitaxel and sirolimus stents reduced the 9-month in-stent late loss (0.54-0.44 mm, 0.32-0.43 mm, vs. 0.90-0.45 mm respectively), and 1-year risk of target vessel revascularization and combined major adverse cardiac events (P < 0.05 for both, in all comparisons), compared with controls. Sirolimus stents had lower late loss than paclitaxel stents (P < 0.01), but similar 1-year clinical outcomes. There were no differences in the risk of death, infarction, or stent thrombosis among the study groups. Conclusion: Both novel DES were effective in reducing neointimal hyperplasia and 1-year re-intervention, compared to bare metal stents. Our findings also suggest that sirolimus is more effective than paclitaxel in reducing angiographic neointima, although this effect was not associated with better clinical outcomes. (C) 2009 Wiley-Liss, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A biofilm is a complex community of surface-associated cells enclosed in a polymer matrix. They attach to solid surfaces and their formation can be affected by growth conditions and co-infection with other pathogens. The presence of biofilm may protect the microorganisms from host defenses, as well as significantly reduce their susceptibility to antifungal agents. Pathogenic microbes can form biofilms on the inert surfaces of implanted devices such as catheters, prosthetic cardiac valves and intrauterine devices (IUDs). The present study was carried out to analyze the presence of biofilm on the surface of intrauterine devices in patients with recurrent vulvovaginal candidiasis, and to determine the susceptibility profile of the isolated yeasts to amphotericin B and fluconazole. Candida albicans was recovered from the IUDs and it was found to be susceptible to the antifungal agents when tested under planktonic growing conditions. These findings indicate the presence of the biofilm on the surface of the IUD as an important risk factor for recurrent vulvovaginal candidiasis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We compared the effects of levonorgestrel-releasing intrauterine devices (LNG-IUD) and a gonadotropin-releasing hormone agonist (GnRHa) on uterine volume, uterine arteries pulsatility index (PI) and endometrial thickness before and after six months of endometriosis treatment. Sixty women aged 18-40 y were allocated randomly to one of two groups: LNG-IUDs were inserted in 30 women, and GnRHa monthly injections were performed on the other 30. All 60 women were submitted to transvaginal 2-D ultrasound scans on the day that the treatment started and then six months later. Measurements of uterine arteries PI, uterine volume and endometrial thickness were performed at both evaluations. The use of LNG-IUDs significantly decreased endometrial thickness (pre = 6.08 +/- 3.00 mm, post = 2.7 +/- 0.98 mm; mean +/- SD), as did the use of GnRHa (pre = 6.96 +/- 3.82 mm, post = 3.23 +/- 2.32 mm). The uterine volume decreased in the GnRHa group (pre = 86.67 +/- 28.38 cm(3), Post = 55.27 +/- 25.52 cm(3)), but not in the LNG-IUD group (pre = 75.77 +/- 20.88 cm(3), post = 75.97 +/- 26.62 cm(3)). Uterine arteries PI increased for both groups; however, the increase was higher in the GnRHa group (0.99 +/- 0.84 vs. 0.38 +/- 0.84, p = 0.007; PI increase in GnRHa and in LNG-IUD groups, respectively). In conclusion, levonorgestrel released directly onto the endometrium by the LNG-IUD induced smaller uterine changes than did the hypoestrogenism induced by GnRHa. Nevertheless, both promoted similar effects on endometrial thickness. (E-mail: wpmartins@gmail.com) (C) 2008 World Federation for Ultrasound in Medicine & Biology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Poly(L-lactic acid) (PLA) is a polymer of great technological interest, whose excellent mechanical properties, thermal plasticity and bioresorbability render it potentially useful for environmental applications, as a biodegradable plastic and as a biocompatible material in biomedicine. The interactions between an implant material surface and host cells play central roles in the integration, biological performance and clinical success of implanted biomedical devices. Osteoblasts from human alveolar bone were chosen to investigate the cell behaviour when in contact with PLA discs. Cell morphology and adhesion through osteopontin (OPN) and fibronectin (FN) expression were evaluated in the initial osteogenesis, as well as cell proliferation, alkaline phosphatase activity and bone nodule formation. It was shown that the polymer favoured cell attachment. Cell proliferation increased until 21 days but in a smaller rate when compared to the control group. On the other hand, ALP activity and bone mineralization were not enhanced by the polymer. It is suggested that this polymer favours cell adhesion in the early osteogenesis in vitro, but it does not enhance differentiation and mineralization. (C) Koninklijke Brill NV, Leiden, 2009

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although the 12-lead electrocardiogram has become an essential medical and research tool, many current and envisaged applications would benefit from simpler devices, using 3-lead ECG configuration. This is particularly true for Ambient Assisted Living (in a broad perspective). However, the chest anatomy of female patients, namely during pregnancy, can hamper the adequate placement of a 3-lead ECG device and, very often, electrodes are placed below the chest rather than at the precise thoracic landmarks. Thus, the aim of this study was to compare the effect of electrode positioning on the ECG signal of pregnant women and provide guidelines for device development. The effect of breast tissue on the ECG signal was investigated by relating breast size with the signal-to-noise ratio, root mean square and R-wave amplitude. Results show that the 3-lead ECG should be placed on the breast rather than under the breast and indicate positive correlation between breast size and signal-to-noise ratio.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação apresentada para a obtenção do grau de Doutor em Engenharia Química, especialidade Engenharia da Reacção Química, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia