970 resultados para Automobile electronic equipment


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to develop a laboratory method for time response evaluation on electronically controlled spray equipment using Programmable Logic Controllers (PLCs). For that purpose, a PLC controlled digital drive inverter was set up to drive an asynchronous electric motor linked to a centrifugal pump on a experimental sprayer equipped with electronic flow control. The PLC was operated via RS232 serial communication from a PC computer. A user program was written to control de motor by adjusting the following system variables, all related to the motor speed: time stopped; ramp up and ramp down times, time running at a given constant speed and ramp down time to stop the motor. This set up was used in conjunction with a data acquisition system to perform laboratory tests with an electronically controlled sprayer. Time response for pressure stabilization was measured while changing the pump speed by +/-20%. The results showed that for a 0.2 s ramp time increasing the motor speed, as an example, an AgLogix Flow Control system (Midwest Technologies Inc.) took 22 s in average to readjust the pressure. When decreasing the motor speed, this time response was down to 8 s. General results also showed that this kind of methodology could make easier the definition of standards for tests on electronically controlled application equipment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The advantages offered by the electronic component LED (Light Emitting Diode) have caused a quick and wide application of this device in replacement of incandescent lights. However, in its combined application, the relationship between the design variables and the desired effect or result is very complex and it becomes difficult to model by conventional techniques. This work consists of the development of a technique, through artificial neural networks, to make possible to obtain the luminous intensity values of brake lights using LEDs from design data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The implementation of vibration analysis techniques based on virtual instrumentation has spread increasingly in the academic and industrial branch, since the use of any software for this type of analysis brings good results at low cost. Among the existing software for programming and creation of virtual instruments, the LabVIEW was chosen for this project. This software has good interface with the method of graphical programming. In this project, it was developed a system of rotating machine condition monitoring. This monitoring system is applied in a test stand, simulating large scale applications, such as in hydroelectric, nuclear and oil exploration companies. It was initially used a test stand, where an instrumentation for data acquisition was inserted, composed of accelerometers and inductive proximity sensors. The data collection system was structured on the basis of an NI 6008 A/D converter of National Instruments. An electronic circuit command was developed through the A/D converter for a remote firing of the test stand. The equipment monitoring is performed through the data collected from the sensors. The vibration signals collected by accelerometers are processed in the time domain and frequency. Also, proximity probes were used for the axis orbit evaluation and an inductive sensor for the rotation and trigger measurement. © (2013) Trans Tech Publications, Switzerland.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate, ex vivo, the precision of five electronic root canal length measurement devices (ERCLMDs) with different operating systems: the Root ZX, Mini Apex Locator, Propex II, iPex, and RomiApex A-15, and the possible influence of the positioning of the instrument tips short of the apical foramen. Material and Methods: Forty-two mandibular bicuspids had their real canal lengths (RL) previously determined. Electronic measurements were performed 1.0 mm short of the apical foramen (-1.0), followed by measurements at the apical foramen (0.0). The data resulting from the comparison of the ERCLMD measurements and the RL were evaluated by the Wilcoxon and Friedman tests at a significance level of 5%. Results: Considering the measurements performed at 0.0 and -1.0, the precision rates for the ERCLMDs were: 73.5% and 47.1% (Root ZX), 73.5% and 55.9% (Mini Apex Locator), 67.6% and 41.1% (Propex II), 61.7% and 44.1% (iPex), and 79.4% and 44.1% (RomiApex A-15), respectively, considering ±0.5 mm of tolerance. Regarding the mean discrepancies, no differences were observed at 0.0; however, in the measurements at -1.0, the iPex, a multi-frequency ERCLMD, had significantly more discrepant readings short of the apical foramen than the other devices, except for the Propex II, which had intermediate results. When the ERCLMDs measurements at -1.0 were compared with those at 0.0, the Propex II, iPex and RomiApex A-15 presented significantly higher discrepancies in their readings. Conclusions: Under the conditions of the present study, all the ERCLMDs provided acceptable measurements at the 0.0 position. However, at the -1.0 position, the ERCLMDs had a lower precision, with statistically significant differences for the Propex II, iPex, and RomiApex A-15.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND A rapid review, guided by a protocol, was conducted to inform development of the World Health Organization's guideline on personal protective equipment in the context of the ongoing (2013-present) Western African filovirus disease outbreak, with a focus on health care workers directly caring for patients with Ebola or Marburg virus diseases. METHODS Electronic databases and grey literature sources were searched. Eligibility criteria initially included comparative studies on Ebola and Marburg virus diseases reported in English or French, but criteria were expanded to studies on other viral hemorrhagic fevers and non-comparative designs due to the paucity of studies. After title and abstract screening (two people to exclude), full-text reports of potentially relevant articles were assessed in duplicate. Fifty-seven percent of extraction information was verified. The Grading of Recommendations Assessment, Development and Evaluation framework was used to inform the quality of evidence assessments. RESULTS Thirty non-comparative studies (8 related to Ebola virus disease) were located, and 27 provided data on viral transmission. Reporting of personal protective equipment components and infection prevention and control protocols was generally poor. CONCLUSIONS Insufficient evidence exists to draw conclusions regarding the comparative effectiveness of various types of personal protective equipment. Additional research is urgently needed to determine optimal PPE for health care workers caring for patients with filovirus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study analyzes the patterns of agglomeration of some modern manufacturing sectors in India, and in particular the Indian automobile sector. It also examines and contrasts the factors that have led to different patterns of cluster development in two leading auto clusters in India-Chennai and the National Capital Region (NCR). Moreover, the study analyzes whether firms in clusters perform better than those that are excluded and whether the relative importance of variables that determine the behavior of firms differs among clusters. Our analyses, which employ a combination of quantitative and qualitative methods, show that Indian industrial clusters are largely concentrated in the three clustered regions: NCR, Mumbai-Pune, and Chennai-Bangalore, across different manufacturing sectors. Our study of the auto clusters in Chennai and the NCR find considerable differences in the patterns of cluster formation, due partly to the historical and policy conditions under which firms, particularly, the lead firms must operate. Moreover, our econometric analyses confirmed that being part of a cluster positively influences the performance of the auto component firms and those belonging to a cluster perform better.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In India, as the production of passenger cars increased, many local small and medium enterprises (SMEs) entered the parts and components manufacturing sector. The sources of knowledge for large enterprises and SMEs are different. Naturally, spillover effects among large enterprises and between large enterprises and SMEs are different. This paper focuses on knowledge spillover among large enterprises and from large enterprises to SMEs. Subcontractor can absorb relation-specific skills through repeated interaction with parent company. The results of field survey emphasizes that relation-specific skills are a determinant factor of spillover effects from assemblers and large auto component manufacturers to SMEs. Econometric analysis shows that spillover effects among medium and large automobile units and from medium and large automobile units to small units went beyond boundary of cluster.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper examines factors that encourage firms to go into supply chain collaborations (SCC) and relationships between SCC and supply chain performances (SCP), using a questionnaire survey on Thai automotive and electronics industries in 2012. OLS regression results show firms established supplier evaluation and audit system, system of rewards for high-performance supplier and long-term transactions with their supply chain partners under a competitive pressure are more closely cooperate with these partners on information sharing and decision synchronization. Instrumental variables regression indicates SCC arisen from competitive pressure, supplier evaluation and audit, a system of rewards for high-performance supplier and long-term relationship causally influence SCP such as on-time delivery, responsiveness to fast procurement, flexibility to customer need, and profit.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper examines factors that promote firms to develop supply chain collaborations (SCC) with their partners and relationships between SCC and supply chain operational performances (SCOP), using a questionnaire survey on Thai automotive and electronics industries in 2012. This paper also carries out a comparative study on these questions between the electronics and automotive industries. Two-stage least squares (2SLS) regressions verifY that supplier evaluation and audit is a foundation for firms to share information and synchronize decision makings with their partners, and that such SCC are significantly related to SCOP indictors such as on-time delivery, fast procurement, and flexibility to customer need irrespective of industry type. On the other hand, competitive pressure motivates only electronics firms to develop sec in order to be more innovative.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A fully integrated on-board electronic system that can perform in-situ structural health monitoring (SHM) of aircraft?s structures using specifically designed equipment for SHM based on guided wave ultrasonic method or Lamb waves? method is introduced. This equipment is called Phased Array Monitoring for Enhanced Life Assessment (PAMELA III) and is an essential part of overall PAMELA SHM? system. PAMELA III can generate any kind of excitation signals, acquire the response signals that propagate throughout the structure being tested, and perform the signal processing for damage detection directly on the structure without need to send the huge amount of raw signals but only the final SHM maps. It monitors the structure by means of an array of integrated Phased Array (PhA) transducers preferably bonded onto the host structure. The PAMELA III hardware for SHM mapping has been designed, built and subjected to laboratory tests, using aluminum and CFRP structures. The 12 channel system has been designed to be low weight (265 grams only), to have a small form factor, to be directly mounted above the integrated PhA transducers without need for cables and to be EMI protected so that the equipment can be taken on board an aircraft to perform required SHM analyses by use of embedded SHM algorithms. Moreover, the autonomous, automatic and on real-time working procedure makes it suitable for the avionic field, sending the corresponding alerts, maps and reports to external equipment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Office of Research and Development, Washington, D.C.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mode of access: Internet.