780 resultados para Assesment of performance effectiveness


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim To evaluate ex vivo effectiveness of the three formulations of bleaching materials for intracoronal bleaching of root filled teeth using the walking bleach technique.Methodology Extracted premolar teeth were stained artificially with human blood. After biomechanical preparation, the root canals were filled and a 3-mm thick intermediate base of zinc phosphate cement was placed at the level of the cementoenamel junction. The teeth were divided into four groups (n = 12): C (control, without bleaching material), A1 (sodium perborate + distilled water), A2 (sodium perborate + 10% carbamide peroxide) and A3 (sodium perborate + 35% carbamide peroxide). The bleaching materials were changed at 7 and 14 days. Evaluation of shade was undertaken with aid of the VITA Easyshade (TM) (Delta E*ab) and was performed after tooth staining and at 7, 14 and 21 days after bleaching, based on the CIELAB system. Data were analysed by ANOVA for repeated measurements, Tukey and Dunnett tests (alpha = 0.05).Results The Tukey test revealed that group A1 (10.58 +/- 4.83 Delta E*ab) was statistically different from the others (A2, 19.57 +/- 4.72 Delta E*ab and A3, 17.58 +/- 3.33 Delta E*ab), which were not different from each other. At 7 days: A1 was significantly different from A2; at 14 and 21 days: A2 and A3 were significantly better than A1; the Dunnett test revealed that the control group was different from A1, A2 and A3 at all periods (P < 0.05).Conclusion Sodium perborate associated with both 10% and 35% carbamide peroxide was more effective than when associated with distilled water.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim To evaluate in vitro the effectiveness of sodium hypochlorite (NaOCl). chlorhexidine (CHX) and live intracanal medicaments on microorganisms within root canals.Methodology Ninety-six human single-rooted extracted teeth were used. After removing the crowns, canal preparation was completed and the external root Surfaces were coated with epoxy resin. Following sterilization. The teeth were contaminated with Candida albicans and enterococcus faecalis. and were incubated at 37 +/- 1 degreesC for 7 days. The teeth were divided according to the irrigant solution or intracanal medicament: group 1. sterile physiologic solution (SPS) and calcium hydroxide (Ca(OH)(2)) paste: group 2. SPS and camphorated paramonochlorophenol (CPMC): group 3.SPS and tricresol formalin: group 4, SPS and CaOH2 + CPMC paste: group 5, SPS and PMC furacin; group 6.2.5%, NaOCl without intracanal medication: group 7, 2.0% CHX without intracanal medication and group 8, SPS Without intracanal medication (control group). Microbiological samples were collected with sterile paper points, and bacterial growth was determined. The data were submitted to the analysis of variance (ANOVA. P = 0.05).Results For C. albicans, groups 3 and S were statistically less effective than groups 1, 2. 4 and 5 (Kruskal-Wallis (K-W) = 65.241; gl = 7; P = 0.001). For E. faecalis, groups 6 and 8 were statistically less effective than groups 1-4 and 7 (K-W = 61.048; gl = 7; P = 0.001).Conclusions Ca(OH)(2) + CPMC paste was the most effective intracanal medicament for the elimination of the two microorganisms; 2.0% CHX solution was more effective than 2.5% NaOCl against E. faecalis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. To evaluate the effectiveness of the color change of hybrid light-emitting diode (LED) and low-intensity infrared diode laser devices for activating dental bleaching and to verify the occurrence of a color regression with time. Material and methods. A total of 180 specimens obtained from human premolars were immersed in a coffee solution for 15 days for darkening and then divided into eight experimental groups (n = 20 in each) as follows: G1, bleaching without light; G2, bleaching with halogen light; G3, bleaching with a blue LED (1000 mW/470 nm) and a laser device (120 mW/795 nm) simultaneously; G4, bleaching with an LED emitting blue light (1000 mW/470 nm); G5, bleaching with a blue LED (800 mW/470 nm) and a laser device (500 mW/830 nm) simultaneously; G6, bleaching with a blue LED device (800 mW); G7, bleaching with a green LED (600 mW/530 nm) and a laser device (120 mW/795 nm) simultaneously; and G8, bleaching with a green LED (600 mW). Three measurements were performed (at baseline and 14 days and 12 months after bleaching) using a Vita Easyshade spectrophotometer. The data were submitted to two-way ANOVA and a Tukey test. Results. All groups showed significantly higher Delta E values than Group G1, with the exception of Group G8. Variations in the Delta E values at 14 days were significant when compared with those obtained at baseline and after 12 months. Conclusions. Light activation of the bleaching gel provided faster and more intense bleaching than use of the bleaching gel without light activation. Combinations of low-intensity diode lasers are ineffective as a bleaching gel activator. Color regression was observed after 12 months of storage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to estimate genetic parameters for racing performance traits in Quarter Horses in Brazil. The data (provided by the Sorocaba Jockey Club) came from 3 Brazilian hippodromes in 1994-2003, with 11875 observations of race time and 7775 of the speed index (Sl), distributed in 2403 and 2169 races, respectively. The variance components were estimated by the MTGSAM program, under animal models including the random additive genetic effect, random permanent environmental effect, and the fixed effects of sex, age and race. Heritabilities for race time and the SI, for the 3 distances studied (301, 365 and 402 in), varied from 0.26 to 0.41 and from 0. 14 to 0. 19, respectively, whereas repeatabilities varied from 0.36 to 0.68 (time) and from 0.27 to 0.42 (SI) and the genetic correlations from 0.90 to 0.97 (time) and from 0.67 to 0.73 (SI).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the effectiveness of acidic low-fluoride dentifrices compared to conventional neutral dentifrices. Enamel blocks were submitted to pH cycling and treatment with slurries of dentifrices containing 0, 275, 412, 550 and 1,100 mu g F/g (pH 4.5 or 7.0), and also a commercial dentifrice (1,100 mu g F/g) and a commercial children's dentifrice (500 mu g F/ g). Variations in surface microhardness and in the mineral content in enamel after pH cycling were calculated. Enamel blocks treated with acidic dentifrices exhibited less mineral loss compared to neutral dentifrices (ANOVA; p < 0.05). The acidic dentifrices with 412 and 550 mu g F/g had the same effectiveness as the neutral 1,100-mu g F/g dentifrice and commercial 1,100-mu g F/g dentifrice. Copyright (c) 2007 S. Karger AG, Basel

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper deals with the problem of establishing stabilizing state-dependent switching laws in DC-DC converters operating at continuous conduction mode (CCM) and comparing their performance indexes. Firstly, the nature of the problem is defined, that is, the study of switched affine systems, which may not share a common equilibrium point. The concept of stability is, therefore, broadened. Then, the central theorem is proposed, from which a family of switching laws can be derived, namely the minimum law and the hold state law. Some of these are proved to stabilize the basic DC-DC converters and then, their performances are compared to another law, from a previous work, by simulation, where a great reduction in overshoot is obtained. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The sugarcane mechanized planting is becoming increasingly widespread in Brazil due to a higher operability and better working conditions offered to workers compared to other types of planting. Studies related to this topic are insufficient or scarce in Brazil. In this context, the aim of this study was to evaluate the operation quality of sugarcane mechanized planting in two operation shifts, by means of statistical process control. The mechanized planting was held on March 2012 and statistical design was completely randomized with two treatments, totaling 40 replications for the day shift and 40 replications for the night shift. The variables evaluated were: speed, engine rotation, engine oil pressure, water temperature of the engine, effective field capacity and the time consumption hourly and effective fuel. The use of statistical control charts showed that random intrinsic do not cause this process. The tractor alignment error showed outliers in the day and night shifts operations, indicating a possible delay in receiving the signal. The water temperature of the engine and the effective fuel consumption showed lower variability in nighttime operation with average values of 81°C and 22.66 L ha-1, respectively. The hourly fuel consumption had greater variability and consequently lower quality during the night of the operation, with an average consumption of 25.46 L h-1 while the day shift showed 26.86 L h-1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Combined Refrigeration and Power (CRP) plants generate power and refrigerate a thermal load simultaneously from the same fuel. The overall efficiency is a parameter based on the first law generally used to quantify the fuel saving, in the sense that a plant that has greater overall efficiency saves more fuel than others to generate the same useful energy. However, the literature shows that the overall efficiency and other parameters of performance are defined in several different ways. This heterogeneity is not desirable when considering a coherent and universally accepted parameter of performance based on the first law. In this work, some parameters found in the literature are critically analyzed in order to indicate the most proper one. The indicated parameter is then formally analyzed in order to verify its mathematical consistency. The primary energy rate is considered the most well-suited parameter based on the first law to characterize the performance of a CRP plant. © 2013 Elsevier Ltd and IIR.