930 resultados para transient thermal distortion analysis


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The combined-cycle gas and steam turbine power plant presents three main pieces of equipment: gas turbines, steam turbines and heat recovery steam generator (HRSG). In case of HRSG failure the steam cycle is shut down, reducing the power plant output. Considering that the technology for design, construction and operation of high capacity HRSGs is quite recent its availability should be carefully evaluated in order to foresee the performance of the power plant. This study presents a method for reliability and availability evaluation of HRSGs installed in combined-cycle power plant. The method`s first step consists in the elaboration of the steam generator functional tree and development of failure mode and effects analysis. The next step involves a reliability and availability analysis based on the time to failure and time to repair data recorded during the steam generator operation. The third step, aiming at availability improvement, recommends the fault-tree analysis development to identify components the failure (or combination of failures) of which can cause the HRSG shutdown. Those components maintenance policy can be improved through the use of reliability centered maintenance (RCM) concepts. The method is applied on the analysis of two HRSGs installed in a 500 MW combined-cycle power plant. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, we propose an approach to the transient and steady-state analysis of the affine combination of one fast and one slow adaptive filters. The theoretical models are based on expressions for the excess mean-square error (EMSE) and cross-EMSE of the component filters, which allows their application to different combinations of algorithms, such as least mean-squares (LMS), normalized LMS (NLMS), and constant modulus algorithm (CMA), considering white or colored inputs and stationary or nonstationary environments. Since the desired universal behavior of the combination depends on the correct estimation of the mixing parameter at every instant, its adaptation is also taken into account in the transient analysis. Furthermore, we propose normalized algorithms for the adaptation of the mixing parameter that exhibit good performance. Good agreement between analysis and simulation results is always observed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aiming the use of the sewage sludge produced in one of the largest Brazilian wastewater treatment stations as a raw material for the ceramic industry, the sintering process of the ashes produced from its calcination was evaluated by heating microscopy thermal analysis (HMTA). From the microprocessed images, a method was developed to obtain HMTA dimensional change curves as a function of temperature, equivalent to those usually obtained from dilatometers or by thermomechanical analysis (TMA). The final product after sintering at 1050 degrees C, characterized by X-ray fluorescence spectrometry, scanning electron microscopy and X-ray dispersive energy, indicates the presence of a vitreous phase containing phosphorus, which explains the good sintering properties of the studied calcined sludge, as shown from its HMTA dimensional change curve.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Vitamin PP includes two vitamers, niacin and niacinamide which are essential for energy production. Vitamins are sensitive and losses can occur during shelf life and heating processes. Thermal analysis can provide information about thermal behavior of each vitamer relating them with time and/or temperature exposure. The vitamers thermal behavior were studied by TG/DTG and DSC under air and nitrogen atmosphere and the results showed that niacin is more stable than the niacinamide and the decomposition happens by volatilization at 238 A degrees C while niacinamide melts at 129 A degrees C and volatilize at 254 A degrees C when there is the total mass loss in the TG/DTG curves.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to investigate the influence of different crucible materials on the thermal analysis of binary systems. The thermal properties of two distinct solutions were measured both by Differential Scanning Calorimetry (DSC) and freeze-drying microscopy and the results were compared. The glass transition of the maximally freeze-concentrate (T (g)`) and the eutectic melting temperature (T (eut)) were not influenced by the crucible material. However the heat of fusion (Delta H) involved during the T (eut) as well as the Delta C (p) involved during the T (g)` of the solutions were affected.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

N,N-dimethyl-pyrrolidinium iodide has been investigated using differential scanning calorimetry, nuclear magnetic resonance (NMR) spectroscopy, second moment calculations, and impedance spectroscopy. This pyrrolidinium salt exhibits two solid-solid phase transitions, one at 373 K having an entropy change, Delta S, of 38 J mol(-1) K-1 and one at 478 K having Delta S of 5.7 J mol(-1) K-1. The second moment calculations relate the lower temperature transition to a homogenization of the sample in terms of the mobility of the cations, while the high temperature phase transition is within the temperature region of isotropic tumbling of the cations. At higher temperatures a further decrease in the H-1 NMR linewidth is observed which is suggested to be due to diffusion of the cations. (C) 2005 American Institute of Physics.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Although the cariostatic effects of CO(2) laser on enamel have been shown, its effects on root surface demineralization remains uncertain. The objectives of this in vitro research was to establish safe parameters for a pulsed 10.6 mu m CO(2) laser and to evaluate its effect on morphological features of the root surface, as well as on the reduction of root demineralization. Ninety-five human root surfaces were randomly divided into five groups: G1-No treatment (control); G2-2.5 J/cm(2); G3-4.0 J/cm(2); G4-5.0 J/cm(2); and G5-6.0 J/cm(2). Intrapulpal temperature was evaluated during root surface irradiation by a thermocouple and morphological changes were evaluated by SEM. After the surface treatment, the specimens were submitted to a 7-day pH-cycling model. Subsequently, the cross-sectional Knoop microhardness values were measured. For all irradiated groups, intrapulpal temperature changes were less than 1.5 degrees C. Scanning electron microscopy images indicated that fluences as low as 4.0 J/cm(2) were sufficient to induce morphological changes in the root surface. Additionally, for fluences reaching or exceeding 4.0 J/cm(2), laser-induced inhibitory effects on root surface demineralization were observed. It was concluded that laser energy density in the range of 4.0 to 6.0 J/cm(2) could be applied to a dental root to reduce demineralization of this surface without compromising pulp vitality.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper we analyzed the adsorption of gases and vapors on graphitised thermal carbon black by using a modified DFT-lattice theory, in which we assume that the behavior of the first layer in the adsorption film is different from those of second and higher layers. The effects of various parameters on the topology of the adsorption isotherm were first investigated, and the model was then applied in the analysis of adsorption data of numerous substances on carbon black. We have found that the first layer in the adsorption film behaves differently from the second and higher layers in such a way that the adsorbate-adsorbate interaction energy in the first layer is less than that of second and higher layers, and the same is observed for the partition function. Furthermore, the adsorbate-adsorbate and adsorbate-adsorbent interaction energies obtained from the fitting are consistently lower than the corresponding values obtained from the viscosity data and calculated from the Lorentz-Berthelot rule, respectively.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

As wind power generation undergoes rapid growth, new technical challenges emerge: dynamic stability and power quality. The influence of wind speed disturbances and a pitch control malfunction on the quality of the energy injected into the electric grid is studied for variable-speed wind turbines with different power-electronic converter topologies. Additionally, a new control strategy is proposed for the variable-speed operation of wind turbines with permanent magnet synchronous generators. The performance of disturbance attenuation and system robustness is ascertained. Simulation results are presented and conclusions are duly drawn. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Química e Bioquímica

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND/OBJECTIVES: This study aims to assess whether patent foramen ovale (PFO) closure is superior to medical therapy in preventing recurrence of cryptogenic ischemic stroke or transient ischemic attack (TIA). METHODS: We searched PubMed for randomized trials which compared PFO closure with medical therapy in cryptogenic stroke/TIA using the items: "stroke or cerebrovascular accident or TIA" and "patent foramen ovale or paradoxical embolism" and "trial or study". RESULTS: Among 650 potentially eligible articles, 3 were included including 2303 patients. There was no statistically significant difference between PFO-closure and medical therapy in ischemic stroke recurrence (1.91% vs. 2.94% respectively, OR: 0.64, 95%CI: 0.37-1.10), TIA (2.08% vs. 2.42% respectively, OR: 0.87, 95%CI: 0.50-1.51) and death (0.60% vs. 0.86% respectively, OR: 0.71, 95%CI: 0.28-1.82). In subgroup analysis, there was significant reduction of ischemic strokes in the AMPLATZER PFO Occluder arm vs. medical therapy (1.4% vs. 3.04% respectively, OR: 0.46, 95%CI: 0.21-0.98, relative-risk-reduction: 53.2%, absolute-risk-reduction: 1.6%, number-needed-to-treat: 61.8) but not in the STARFlex device (2.7% vs. 2.8% with medical therapy, OR: 0.93, 95%CI: 0.45-2.11). Compared to medical therapy, the number of patients with new-onset atrial fibrillation (AF) was similar in the AMPLATZER PFO Occluder arm (0.72% vs. 1.28% respectively, OR: 1.81, 95%CI: 0.60-5.42) but higher in the STARFlex device (0.64% vs. 5.14% respectively, OR: 8.30, 95%CI: 2.47-27.84). CONCLUSIONS: This meta-analysis does not support PFO closure for secondary prevention with unselected devices in cryptogenic stroke/TIA. In subgroup analysis, selected closure devices may be superior to medical therapy without increasing the risk of new-onset AF, however. This observation should be confirmed in further trials using inclusion criteria for patients with high likelihood of PFO-related stroke recurrence.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: To assess whether the combined analysis of all phase III trials of nonvitamin-K-antagonist (non-VKA) oral anticoagulants in patients with atrial fibrillation and previous stroke or transient ischemic attack shows a significant difference in efficacy or safety compared with warfarin. METHODS: We searched PubMed until May 31, 2012, for randomized clinical trials using the following search items: atrial fibrillation, anticoagulation, warfarin, and previous stroke or transient ischemic attack. Studies had to be phase III trials in atrial fibrillation patients comparing warfarin with a non-VKA currently on the market or with the intention to be brought to the market in North America or Europe. Analysis was performed on intention-to-treat basis. A fixed-effects model was used as more appropriate than a random-effects model when combining a small number of studies. RESULTS: Among 47 potentially eligible articles, 3 were included in the meta-analysis. In 14 527 patients, non-VKAs were associated with a significant reduction of stroke/systemic embolism (odds ratios, 0.85 [95% CI, 074-0.99]; relative risk reduction, 14%; absolute risk reduction, 0.7%; number needed to treat, 134 over 1.8-2.0 years) compared with warfarin. Non-VKAs were also associated with a significant reduction of major bleeding compared with warfarin (odds ratios, 0.86 [95% CI, 075-0.99]; relative risk reduction, 13%; absolute risk reduction, 0.8%; number needed to treat, 125), mainly driven by the significant reduction of hemorrhagic stroke (odds ratios, 0.44 [95% CI, 032-0.62]; relative risk reduction, 57.9%; absolute risk reduction, 0.7%; number needed to treat, 139). CONCLUSIONS: In the context of the significant limitations of combining the results of disparate trials of different agents, non-VKAs seem to be associated with a significant reduction in rates of stroke or systemic embolism, hemorrhagic stroke, and major bleeding when compared with warfarin in patients with previous stroke or transient ischemic attack.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Thermal analysis, powder diffraction, and Raman scattering as a function of the temperature were carried out on K2BeF4. Moreover, the crystal structure was determined at 293 K from powder diffraction. The compound shows a transition from Pna21 to Pnam space group at 921 K with a transition enthalpy of 5 kJ/mol. The transition is assumed to be first order because the compound shows metastability. Structurally and spectroscopically the transition is similar to those observed in (NH4)2SO4, which suggests that the low-temperature phase is ferroelectric. In order to confirm it, the spontaneous polarization has been computed using an ionic model.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Multiexponential decays may contain time-constants differing in several orders of magnitudes. In such cases, uniform sampling results in very long records featuring a high degree of oversampling at the final part of the transient. Here, we analyze a nonlinear time scale transformation to reduce the total number of samples with minimum signal distortion, achieving an important reduction of the computational cost of subsequent analyses. We propose a time-varying filter whose length is optimized for minimum mean square error

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a thermal modeling for power management of a new three-dimensional (3-D) thinned dies stacking process. Besides the high concentration of power dissipating sources, which is the direct consequence of the very interesting integration efficiency increase, this new ultra-compact packaging technology can suffer of the poor thermal conductivity (about 700 times smaller than silicon one) of the benzocyclobutene (BCB) used as both adhesive and planarization layers in each level of the stack. Thermal simulation was conducted using three-dimensional (3-D) FEM tool to analyze the specific behaviors in such stacked structure and to optimize the design rules. This study first describes the heat transfer limitation through the vertical path by examining particularly the case of the high dissipating sources under small area. First results of characterization in transient regime by means of dedicated test device mounted in single level structure are presented. For the design optimization, the thermal draining capabilities of a copper grid or full copper plate embedded in the intermediate layer of stacked structure are evaluated as a function of the technological parameters and the physical properties. It is shown an interest for the transverse heat extraction under the buffer devices dissipating most the power and generally localized in the peripheral zone, and for the temperature uniformization, by heat spreading mechanism, in the localized regions where the attachment of the thin die is altered. Finally, all conclusions of this analysis are used for the quantitative projections of the thermal performance of a first demonstrator based on a three-levels stacking structure for space application.