207 resultados para tee
Resumo:
The case of a 55-year-old woman is presented, whose clinical signs were initially suggestive of infective endocarditis. Transthoracic echocardiography (TTE) provided the diagnosis of a large left atrial myxoma attached to the anterior mitral leaflet. Perioperative transesophageal echocardiography (TEE) confirmed preoperative findings and assisted the surgical team in the assessment of tumour size, area of attachment, and mobility. Following tumour resection, TEE demonstrated residual moderate mitral valve regurgitation, which resulted in a change of surgical strategy. This report reinforces the importance of intraoperative TEE to facilitate and optimize surgical and anaesthesiological management of patients presenting with non-specific cardiorespiratory symptoms.
Resumo:
American College of Cardiology/American Heart Association guidelines for the diagnosis and management of heart failure recommend investigating exacerbating conditions such as thyroid dysfunction, but without specifying the impact of different thyroid-stimulation hormone (TSH) levels. Limited prospective data exist on the association between subclinical thyroid dysfunction and heart failure events.
Resumo:
The aim of this study was to test the hypothesis that ear oximetry immediately after the release of a sustained Valsalva maneuver accurately detects patent foramen ovale (PFO). One hundred sixty-five scuba divers underwent transesophageal echocardiography (TEE; reference method) for PFO assessment. Ear oximetry of the right earlobe was performed in a different room within a time frame of 2 hours before or after TEE. The subject and the oximetry operator were unaware of the results of TEE. Oxygen saturation (SO(2)) measurements were obtained at baseline and during the release phase of 4 Valsalva maneuvers within 10 minutes, and the average SO(2) change (SO(2) at baseline minus SO(2) at Valsalva release) was determined as the primary study end point. One hundred seventeen divers had no PFO, and 48 (29%) had PFO by TEE (mean age 39 ± 8 years). The average SO(2) change was 0.79 ± 1.13% (i.e., a slight absolute SO(2) decrease in response to the Valsalva maneuver) in the group without PFO and 1.67 ± 1.19% in the PFO group (p <0.0001). Using receiver-operating characteristic curve analysis, a PFO as defined by TEE could be detected at a threshold of a Valsalva-induced decrease in SO(2) of ≥0.825 percentage points in comparison to baseline (sensitivity 0.756, specificity 0.706, area under the receiver-operating characteristic curve 0.763, p <0.0001, negative predictive value 0.882). In conclusion, the entirely noninvasive method of ear oximetry in response to repetitive Valsalva maneuvers is accurate and useful as a screening method for the detection of a PFO, as shown in this study of divers.
Resumo:
Data from prospective cohort studies regarding the association between subclinical hyperthyroidism and cardiovascular outcomes are conflicting.We aimed to assess the risks of total and coronary heart disease (CHD) mortality, CHD events, and atrial fibrillation (AF) associated with endogenous subclinical hyperthyroidism among all available large prospective cohorts.
Resumo:
The suspected cause of clinical manifestations of patent foramen ovale (PFO) is a transient or a permanent right-to-left shunt (RLS). Contrast-enhanced transcranial Doppler ultrasound (c-TCD) is a reliable alternative to transesophageal echocardiography (TEE) for diagnosis of PFO, and enables also the detection of extracardiac RLS. The air-containing echo contrast agents are injected intravenously and do not pass the pulmonary circulation. In the presence of RLS, the contrast agents bypass the pulmonary circulation and cause microembolic signals (MES) in the basal cerebral arteries, which are detected by TCD. The two main echo contrast agents in use are agitated saline and D-galactose microparticle solutions. At least one middle cerebral artery (MCA) is insonated, and the ultrasound probe is fixed with a headframe. The monitored Doppler spectra are stored for offline analysis (e.g., videotape) of the time of occurrence and number of MES, which are used to assess the size and functional relevance of the RLS. The examination is more sensitive, if both MCAs are investigated. In the case of negative testing, the examination is repeated using the Valsalva maneuver. Compared to TEE, c-TCD is more comfortable for the patient, enables an easier assessment of the size and functional relevance of the RLS, and allows also the detection of extracardiac RLS. However, c-TCD cannot localize the site of the RLS. Therefore, TEE and TCD are complementary methods and should be applied jointly in order to increase the diagnostic accuracy for detecting PFO and other types of RLS.
Resumo:
BACKGROUND: Percutaneous closure of patent foramen ovale (PFO) is generally performed using intra-procedural guidance by transoesophageal (TEE) or intracardiac (ICE) echocardiography. While TEE requires sedation or general anaesthesia, ICE is costly and adds incremental risk, and both imaging modalities lengthen the procedure. METHODS: A total of 825 consecutive patients (age 51 +/- 13 years; 58% male) underwent percutaneous PFO closure solely under fluoroscopic guidance, without intra-procedural echocardiography. The indications for PFO closure were presumed paradoxical embolism in 698 patients (95% cerebral, 5% other locations), an embolic event with concurrent aetiologies in 47, diving in 51, migraine headaches in 13, and other reasons in 16. An atrial septal aneurysm was associated with the PFO in 242 patients (29%). RESULTS: Permanent device implantation failed in two patients (0.2%). There were 18 procedural complications (2.2%), including embolization of the device or parts of it in five patients with successful percutaneous removal in all cases, air embolism with transient symptoms in four patients, pericardial tamponade requiring pericardiocentesis in one patient, a transient ischaemic attack with visual symptoms in one patient, and vascular access site problems in seven patients. There were no long-term sequelae. Contrast TEE at six months showed complete abolition of right-to-left shunt via PFO in 88% of patients, whereas a minimal, moderate or large residual shunt persisted in 7%, 3%, and 2%, respectively. CONCLUSIONS: This study confirms the safety and feasibility of percutaneous PFO closure without intra-procedural echocardiographic guidance in a large cohort of consecutive patients.
Resumo:
The goal of this study was to assess the feasibility, safety and success of a system which uses radiofrequency energy (RFE) rather than a device for percutaneous closure of patent foramen ovale (PFO). METHODS: Sixteen patients (10 men, 6 women, mean age 50 years) were included in the study. All of them had a proven PFO with documented right-to-left shunt (RLS) after Valsalva manoeuvre (VM) during transoesophageal echocardiography (TEE). The patients had an average PFO diameter of 6 +/- 2 mm at TEE and an average of 23 +/- 4 microembolic signals (MES) in power M-mode transcranial Doppler sonography (pm-TCD), measured over the middle cerebral artery. An atrial septal aneurysm (ASA) was present in 7 patients (44%). Balloon measurement, performed in all patients, revealed a stretched PFO diameter of 8 +/- 3 mm. In 2 patients (stretched diameter 11 and 14 mm respectively, both with ASA >10 mm), radiofrequency was not applied (PFO too large) and the PFO was closed with an Amplatzer PFO occluder instead. A 6-month follow-up TEE was performed in all patients. RESULTS: There were no serious adverse events during the procedure or at follow-up (12 months average). TEE 6 months after the first RFE procedure showed complete closure of the PFO in 50% of the patients (7/14). Closure appeared to be influenced by PFO diameter, complete closure being achieved in 89% (7/8) with a balloon-stretched diameter < or =7 mm but in none of the patients >7 mm. Only one of the complete closure patients had an ASA. Of the remainder, 4 (29%) had an ASA. Although the PFO was not completely closed in this group, some reduction in the diameter of the PFO and in MES was documented by TEE and pm-TCD with VM. Five of the 7 residual shunt patients received an Amplatzer PFO occluder. Except for one patient with a minimal residual shunt, all showed complete closure of PFO at 6-month follow-up TEE and pm-TCD with VM. The other two refused a closure device. CONCLUSIONS: The results confirm that radiofrequency closure of the PFO is safe albeit less efficacious and more complex than device closure. The technique in its current state should not be attempted in patients with a balloon-stretched PFO diameter >7 mm and an ASA.
Resumo:
We present a case of an intraoperative acute aortic type A dissection (AADA) extending from the distal ascending aorta to the distal aortic arch, initially not visible on the transesophageal echocardiography (TEE). The rapid confirmation of the diagnosis by means of direct epiaortic ultrasound scanning facilitated decision-making and the subsequent successful surgical treatment.
Resumo:
OBJECTIVE: Compare changes in P-wave amplitude of the intra-atrial electrocardiogram (ECG) and its corresponding transesophageal echocardiography (TEE)-controlled position to verify the exact localization of a central venous catheter (CVC) tip. DESIGN: A prospective study. SETTING: University, single-institutional setting. PARTICIPANTS: Two hundred patients undergoing elective cardiac surgery. INTERVENTIONS: CVC placement via the right internal jugular vein with ECG control using the guidewire technique and TEE control in 4 different phases: phase 1: CVC placement with normalized P wave and measurement of distance from the crista terminalis to the CVC tip; phase 2: TEE-controlled placement of the CVC tip; parallel to the superior vena cava (SVC) and measurements of P-wave amplitude; phase 3: influence of head positioning on CVC migration; and phase 4: evaluation of positioning of the CVC postoperatively using a chest x-ray. MEASUREMENTS AND MAIN RESULTS: The CVC tip could only be visualized in 67 patients on TEE with a normalized P wave. In 198 patients with the CVC parallel to the SVC wall controlled by TEE (phase 2), an elevated P wave was observed. Different head movements led to no significant migration of the CVC (phase 3). On a postoperative chest-x-ray, the CVC position was correct in 87.6% (phase 4). CONCLUSION: The study suggests that the position of the CVC tip is located parallel to the SVC and 1.5 cm above the crista terminalis if the P wave starts to decrease during withdrawal of the catheter. The authors recommend that ECG control as per their study should be routinely used for placement of central venous catheters via the right internal jugular vein.
Resumo:
OBJECTIVE: We report the results and complications associated with standardized intraoperative management designed for the prevention of hemodynamically relevant venous air embolism during surgery performed in the semisitting position. METHODS: A protocol for preoperative evaluation and intraoperative monitoring was developed and applied in 187 consecutive patients who underwent surgery in the semisitting position between 1999 and 2004. The protocol included preoperative transesophageal echocardiography examination (TEE), intraoperative TEE monitoring, catheterization of the right atrium and a combination of fluid input, positive end expiratory pressure, and standardized positioning aiming at a positive pressure in the transverse and sigmoid sinuses. Data were collected retrospectively from the charts and intraoperative anesthesiological protocols of the patients for the incidence of clinically relevant air embolism (i.e., TEE-diagnosed air embolism plus a decrease in end tidal CO2 or hemodynamic changes) and other complications related to the semisitting position. RESULTS: Three cases (1.6%) of relevant venous air embolism occurred in 187 patients. Only 1 case (0.5%) was hemodynamically relevant, with temporary arterial blood pressure decrease and heart rate increase. Pneumatocephalus leading to lethargy was a frequent postoperative finding, which resolved spontaneously in all except 1 patient with epileptic seizure and oculomotor nerve palsy attributable to space-occupying subdurally trapped air, which had to be treated surgically. There was no permanent morbidity or mortality related to the semisitting position. CONCLUSION: Fear of massive venous air embolism is one reason for dramatic decline in the use of the semisitting position in neurosurgical practice. We found that strict adherence to a standardized protocol using TEE monitoring before and during surgery; exclusion of patients with patent foramen ovale; and a combination of positive end expiratory pressure, fluid input, and a standardized position aiming a positive pressure in the transverse and sigmoid sinuses helped to greatly minimize this complication to a rate of 0.5% for hemodynamically relevant events.
Resumo:
OBJECTIVES: To assess feasibility and outcomes of left atrial appendage (LAA) closure when using a patent foramen ovale (PFO) for left atrial access. Background: Because of the fear of entering the left atrium too high, using a PFO for left atrial access during LAA occlusion (LAAO) is generally discouraged. We report our single-center experience using a concomitant PFO for LAAO, thereby avoiding transseptal puncture. METHODS: LAAO was performed with local anesthesia and fluoroscopic guidance only (no echocardiography). The Amplatzer Cardiac Plug (ACP) was used in all patients. After LAAO, the PFO was closed at the same sitting, using an Amplatzer occluder through the ACP delivery sheath. Patients were discharged the same or the following day on dual antiplatelet therapy for 1-6 months, at which time a follow-up transesophageal echocardiogram (TEE) was performed. RESULTS: In 49 (96%) of 51 patients (35 males, age 70.9 ± 11.9 years), LAAO was successful using the PFO for left atrial access. In one patient, a long tunnel PFO precluded LAAO, which was performed via a more caudal transseptal puncture. In a second patient, a previously inserted ASD occluder precluded LAAO, which was abandoned because of pericardial bleeding. PFO closure was successful in all patients. Follow-up TEE was performed in 43 patients 138 ± 34 days after the procedure. It showed proper sitting of both devices in all patients. CONCLUSIONS: Using a PFO for LAAO had a high success rate and could be the default access in all patients with a PFO, potentially reducing procedural complications arising from transseptal puncture.
Resumo:
Aims: To evaluate the accuracy and reproducibility of aortic annulus sizing using a multislice computed tomography (MSCT) based aortic root reconstruction tool compared with conventional imaging among patients evaluated for transcatheter aortic valve replacement (TAVR). Methods and results: Patients referred for TAVR underwent standard preprocedural assessment of aortic annulus parameters using MSCT, angiography and transoesophageal echocardiography (TEE). Three-dimensional (3-D) reconstruction of MSCT images of the aortic root was performed using 3mensio (3mensio Medical Imaging BV, Bilthoven, The Netherlands), allowing for semi-automated delineation of the annular plane and assessment of annulus perimeter, area, maximum, minimum and virtual diameters derived from area and perimeter (aVD and pVD). A total of 177 patients were enrolled. We observed a good inter-observer variability of 3-D reconstruction assessments with concordance coefficients for agreement of 0.91 (95% CI: 0.87-0.93) and 0.91 (0.88-0.94) for annulus perimeter and area assessments, respectively. 3-D derived pVD and aVD correlated very closely with a concordance coefficient of 0.97 (0.96-0.98) with a mean difference of 0.5±0.3 mm (pVD-aVD). 3-D derived pVD showed the best, but moderate concordance with diameters obtained from coronal MSCT (0.67, 0.56-0.75; 0.3±1.8 mm), and the lowest concordance with diameters obtained from TEE (0.42, 0.31-0.52; 1.9±1.9 mm). Conclusions: MSCT-based 3-D reconstruction of the aortic annulus using the 3mensio software enables accurate and reproducible assessment of aortic annulus dimensions.
Resumo:
BACKGROUND Multidetector computed tomography (MDCT) may be useful to identify patients with patent foramen ovale (PFO). The aim of this study was to analyze whether a MDCT performed before pulmonary vein isolation reliably detects a PFO that may be used for access to the left atrium. METHODS AND RESULTS In 79 consecutive patients, who were referred for catheter ablation of symptomatic paroxysmal or persistent atrial fibrillation (AF), the presence of a PFO was explored by MDCT and transesophageal echocardiography (TEE). TEE was considered as the gold standard, and quality of TEE was good in all patients. In 16 patients (20.3%), MDCT could not be used for analysis because of artifacts, mainly because of AF. On TEE, a PFO was found in 15 (23.8%) of the 63 patients with usable MDCT. MDCT detected six PFO of which four were present on TEE. This corresponded to a sensitivity of 26.7%, a specificity of 95.8%, a negative predictive value of 80.7%, and a positive predictive value of 66.7%. The receiver operating characteristics curve of MDCT for the detection of PFO was 0.613 (95% confidence interval 0.493-0.732). CONCLUSIONS MDCT may detect a PFO before pulmonary isolation. However, presence of AF may lead to artifacts on MDCT impeding a meaningful analysis. Furthermore, in this study sensitivity and positive predictive value of MDCT were low and therefore MDCT was not a reliable screening tool for detection of PFO.
Resumo:
The association of measures of physical activity with coronary heart disease (CHD) risk factors in children, especially those for atherosclerosis, is unknown. The purpose of this study was to determine the association of physical activity and cardiovascular fitness with blood lipids and lipoproteins in pre-adolescent and adolescent girls.^ The study population was comprised of 131 girls aged 9 to 16 years who participated in the Children's Nutrition Research Center's Adolescent Study. The dependent variables, blood lipids and lipoproteins, were measured by standard techniques. The independent variables were physical activity measured as the difference between total energy expenditure (TEE) and basal metabolic rate (BMR), and cardiovascular fitness, VO$\rm\sb{2max}$(ml/min/kg). TEE was measured by the doubly-labeled water (DLW) method, and BMR by whole-room calorimetry. Cardiovascular fitness, VO$\rm\sb{2max}$(ml/min/kg), was measured on a motorized treadmill. The potential confounding variables were sexual maturation (Tanner breast stage), ethnic group, body fat percent, and dietary variables. A systematic strategy for data analysis was used to isolate the effects of physical activity and cardiovascular fitness on blood lipids, beginning with assessment of confounding and interaction. Next, from regression models predicting each blood lipid and controlling for covariables, hypotheses were evaluated by the direction and value of the coefficients for physical activity and cardiovascular fitness.^ The main result was that cardiovascular fitness appeared to be more strongly associated with blood lipids than physical activity. An interaction between cardiovascular fitness and sexual maturation indicated that the effect of cardiovascular fitness on most blood lipids was dependent on the stage of sexual maturation.^ A difference of 760 kcal/d physical activity (which represents the difference between the 25th and 75th percentile of physical activity) was associated with negligible differences in blood lipids. In contrast, a difference in 10 ml/min/kg of VO$\rm\sb{2max}$ or cardiovascular fitness (which represents the difference between the 25th and 75th percentile in cardiovascular fitness) in the early stages of sexual maturation was associated with an average positive difference of 15 mg/100 ml ApoA-1 and 10 mg/100 ml HDL-C. ^
Resumo:
INTRODUCTION Hemodynamic management in intensive care patients guided by blood pressure and flow measurements often do not sufficiently reveal common hemodynamic problems. Trans-esophageal echocardiography (TEE) allows for direct measurement of cardiac volumes and function. A new miniaturized probe for TEE (mTEE) potentially provides a rapid and simplified approach to monitor cardiac function. The aim of the study was to assess the feasibility of hemodynamic monitoring using mTEE in critically ill patients after a brief operator training period. METHODS In the context of the introduction of mTEE in a large ICU, 14 ICU staff specialists with no previous TEE experience received six hours of training as mTEE operators. The feasibility of mTEE and the quality of the obtained hemodynamic information were assessed. Three standard views were acquired in hemodynamically unstable patients: 1) for assessment of left ventricular function (LV) fractional area change (FAC) was obtained from a trans-gastric mid-esophageal short axis view, 2) right ventricular (RV) size was obtained from mid-esophageal four chamber view, and 3) superior vena cava collapsibility for detection of hypovolemia was assessed from mid-esophageal ascending aortic short axis view. Off-line blinded assessment by an expert cardiologist was considered as a reference. Inter-rater agreement was assessed using Chi-square tests or correlation analysis as appropriate. RESULTS In 55 patients, 148 mTEE examinations were performed. Acquisition of loops in sufficient quality was possible in 110 examinations for trans-gastric mid-esophageal short axis, 118 examinations for mid-esophageal four chamber and 125 examinations for mid-esophageal ascending aortic short axis view. Inter-rater agreement (Kappa) between ICU mTEE operators and the reference was 0.62 for estimates of LV function, 0.65 for RV dilatation, 0.76 for hypovolemia and 0.77 for occurrence of pericardial effusion (all P < 0.0001). There was a significant correlation between the FAC measured by ICU operators and the reference (r = 0.794, P (one-tailed) < 0.0001). CONCLUSIONS Echocardiographic examinations using mTEE after brief bed-side training were feasible and of sufficient quality in a majority of examined ICU patients with good inter-rater reliability between mTEE operators and an expert cardiologist. Further studies are required to assess the impact of hemodynamic monitoring by mTEE on relevant patient outcomes.