759 resultados para square well


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To carry out a survey data collection from health care workers in Brazil, Croatia, Poland, Ukraine and the USA with two primary goals: (1) to provide information about which aspects of well-being are most likely to need attention when shiftwork management solutions are being developed, and (2) to explore whether nations are likely to differ with respect to the impacts of night work on the well-being of workers involved in health care work. METHODS: The respondents from each nation were sorted into night worker and non-night worker groups. Worker perceptions of being physically tired, mentally tired, and tense at the end of the workday were examined. Subjective reports of perceived felt age were also studied. For each of these four dependent variables, an ANCOVA analysis was carried out. Hours worked per week, stability of weekly work schedule, and chronological age were the covariates for these analyses. RESULTS: The results clearly support the general proposal that nations differ significantly in worker perceptions of well-being. In addition, perceptions of physical and mental tiredness at the end of the workday were higher for night workers. For the perception of being physically tired at the end of a workday, the manner and degree to which the night shift impacts the workers varies by nation. CONCLUSIONS: Additional research is needed to determine if the nation and work schedule differences observed are related to differences in job tasks, work schedule structure, off-the-job variables, and/or other worker demographic variables.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of shift and night work on health shows a high inter- and intra-individual variability, both in terms of kind of troubles and temporal occurrence, related to various intervening factors dealing with individual characteristics, lifestyles, work demands, company organisation, family relations and social conditions. The way we define "health" and "well-being" can significantly influence appraisals, outcomes and interventions. As the goal is the optimisation of shiftworkers' health, it is necessary to go beyond the health protection and to act for health promotion. In this perspective, not only people related to medical sciences, but many other actors (ergonomists, psychologists, sociologists, educators, legislators), as well as shiftworkers themselves. Many models have been proposed aimed at describing the intervening variables mediating and/or moderating the effects; they try to define the interactions and the pathways connecting risk factors and outcomes through several human dimensions, which refer to physiology, psychology, pathology, sociology, ergonomics, economics, politics, and ethics. So, different criteria can be used to evaluate shiftworkers' health and well-being, starting from biological rhythms and ending in severe health disorders, passing through psychological strain, job dissatisfaction, family perturbation and social dis-adaptation, both in the short- and long-term. Consequently, it appears rather arbitrary to focus the problem of shiftworkers' health and tolerance only on specific aspects (e.g. individual characteristics), but a systemic approach appears more appropriate, able to match as many variables as possible, and aimed at defining which factors are the most relevant for those specific work and social conditions. This can support a more effective and profitable (for individuals, companies, and society) adoption of preventive and compensative measures, that must refer more to "countervalues" rather than to "counterweights".

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess factors associated with infant feeding practices on the first day at home after hospital discharge. METHODS: A total of 209 women, who had a child aged four months or less and were living in Itapira, Brazil, were interviewed during the National Immunization Campaign Day in 1999. Statistical analysis was performed using the Chi-square test and a logistic regression model was used for verifying an association between dependent and independent variables. RESULTS: Women aged 25.5 years on average and 18.2% were teenagers. Fifty-three percent of the women delivered vaginally and most vaginal deliveries (78.5%) took place in the public hospital. The prevalence of exclusive breastfeeding on the first day at home was 78.1% and 11.6% of the infants were receiving formula at this time. The only factor associated with EBF on the first day at home was being a teenaged-primiparous mother (OR=9.40; 95% CI: 1.24-71.27). This association remained statistically significant even after controlling for type of delivery and hospital where the birth took place. Feeding formula on the first day at home was only significantly associated with the hospital (i.e., birth at the city hospital was a protective factor (OR=0.33; 95% CI: 0.13-0.86), even after controlling for vaginal delivery. CONCLUSIONS: On the first day at home after hospital discharge, teenaged-primiparous mothers were more likely to exclusive breastfeeding as well as those infants born in the municipal public hospital. Further studies are needed from a multidisciplinary approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As coberturas planas são um dos principais elementos construtivos de uma edificação, necessitando por isso de materiais com qualidade e certificados por organismos competentes, bem como de uma conceção e execução minuciosas. Em Portugal, os estudos sobre as anomalias realmente observadas em coberturas planas são ainda bastante reduzidos. Nesse âmbito, o presente trabalho teve como objetivo, efetuar o levantamento e a análise estatística das principais anomalias e causas identificadas em coberturas planas de 75 edifícios, permitindo assim a elaboração de um estudo que possa contribuir para a prevenção dessas anomalias e que indique também as medidas necessárias à reparação e os respetivos custos associados. As anomalias foram analisadas através da observação "in situ" das coberturas o que conduziu ao preenchimento de fichas de obra com os dados recolhidos. Da análise estatística efetuada aos edifícios, verificou-se que as principais anomalias detetadas estão relacionadas com perfurações e fissurações do sistema impermeabilizante, resultantes da falta de conhecimento dos utilizadores. Foi possível verificar erros de execução de remates em pontos singulares da cobertura, por falta de pormenores construtivos desses pontos ou erros de execução por parte do aplicador. Em muitos dos casos estudados, não foi detetada nenhuma anomalia, porque se considerou razoável considerar que o sistema impermeabilizante tenha atingido o fim de vida útil. O custo médio por metro quadrado associado à reabilitação de uma cobertura plana é influenciado principalmente por dois fatores: área e acessibilidade da cobertura. O tipo de anomalia e/ou a sua causa não determinaram o custo por metro quadrado da reparação efetuada, pois esta foi sempre de caracter integral e nunca pontual.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Disposable screen-printed electrodes (SPCE) were modified using a cosmetic product to partially block the electrode surface in order to obtain a microelectrode array. The microarrays formed were electropolymerized with aniline. Scanning electron microscopy was used to evaluate the modified and polymerized electrode surface. Electrochemical characteristics of the constructed sensor for cadmium analysis were evaluated by cyclic and square-wave voltammetry. Optimized stripping procedure in which the preconcentration of cadmium was achieved by depositing at –1.20 V (vs. Ag/AgCl) resulted in a well defined anodic peak at approximately –0.7 V at pH 4.6. The achieved limit of detection was 4 × 10−9 mol dm−3. Spray modified and polymerized microarray electrodes were successfully applied to quantify cadmium in fish sample digests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A square-wave voltammetric (SWV) method using a hanging mercury drop electrode (HMDE) has been developed for determination of the herbicide molinate in a biodegradation process. The method is based on controlled adsorptive accumulation of molinate for 10 s at a potential of -0.8 V versus AgCl/Ag. An anodic peak, due to oxidation of the adsorbed pesticide, was observed in the cyclic voltammogram at ca. -0.320 V versus AgCl/Ag; a very small cathodic peak was also detected. The SWV calibration plot was established to be linear in the range 5.0x10-6 to 9.0x10-6 mol L-1; this corresponded to a detection limit of 3.5x10-8 mol L-1. This electroanalytical method was used to monitor the decrease of molinate concentration in river waters along a biodegradation process using a bacterial mixed culture. The results achieved with this voltammetric method were compared with those obtained by use of a chromatographic method (HPLC–UV) and no significant statistical differences were observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electroactivity of butylate (BTL) is studied by cyclic voltammetry (CV) and square wave voltammetry (SWV) at a glassy carbon electrode (GCE) and a hanging mercury drop electrode (HMDE). Britton–Robinson buffer solutions of pH 1.9–11.5 are used as supporting electrolyte. CV voltammograms using GCE show a single anodic peak regarding the oxidation of BTL at +1.7V versus AgCl/ Ag, an irreversible process controlled by diffusion. Using a HMDE, a single cathodic peak is observed, at 1.0V versus AgCl/Ag. The reduction of BTL is irreversible and controlled by adsorption. Mechanism proposals are presented for these redox transformations. Optimisation is carried out univaryingly. Linearity ranges were 0.10–0.50 mmol L-1 and 2.0–9.0 µmolL-1 for anodic and cathodic peaks, respectively. The proposed method is applied to the determination of BTL in waters. Analytical results compare well with those obtained by an HPLC method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electroanalytical methods based on square-wave adsorptive-stripping voltammetry (SWAdSV) and flow-injection analysis with square-wave adsorptive-stripping voltammetric detection (FIA-SWAdSV) were developed for the determination of fluoxetine (FXT). The methods were based on the reduction of FXT at a mercury drop electrode at -1.2 V versus Ag/AgCl, in a phosphate buffer of pH 12.0, and on the possibility of accumulating the compound at the electrode surface. The SWAdSV method was successfully applied in the quantification of FXT in pharmaceutical products, human serum samples, and in drug dissolution studies. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was possible to quantify FXT in several pharmaceutical products using FIA-SWAdSV. This method enables analysis of up to 120 samples per hour at reduced costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical behaviour of the pesticide metam (MT) at a glassy carbon working electrode (GCE) and at a hanging mercury drop electrode (HMDE) was investigated. Different voltammetric techniques, including cyclic voltammetry (CV) and square wave voltammetry (SWV), were used. An anodic peak (independent of pH) at +1.46 V vs AgCl/Ag was observed in MTaqueous solution using the GCE. SWV calibration curves were plotted under optimized conditions (pH 2.5 and frequency 50 Hz), which showed a linear response for 17–29 mg L−1. Electrochemical reduction was also explored, using the HMDE. A well defined cathodic peak was recorded at −0.72 V vs AgCl/ Ag, dependent on pH. After optimizing the operating conditions (pH 10.1, frequency 150 Hz, potential deposition −0.20 V for 10 s), calibration curves was measured in the concentration range 2.5×10−1 to 1.0 mg L−1 using SWV. The electrochemical behaviour of this compound facilitated the development of a flow injection analysis (FIA) system with amperometric detection for the quantification of MT in commercial formulations and spiked water samples. An assessment of the optimal FIA conditions indicated that the best analytical results were obtained at a potential of +1.30 V, an injection volume of 207 μL and an overall flow rate of 2.4 ml min−1. Real samples were analysed via calibration curves over the concentration range 1.3×10−2 to 1.3 mg L−1. Recoveries from the real samples (spiked waters and commercial formulations) were between 97.4 and 105.5%. The precision of the proposed method was evaluated by assessing the relative standard deviation (RSD %) of ten consecutive determinations of one sample (1.0 mg L−1), and the value obtained was 1.5%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A detailed study of voltammetric behavior of ethiofencarb (ETF) is reported using glassy carbon electrode (GCE) and hanging mercury drop electrode (HMDE). With GCE, it is possible to verify that the oxidative mechanism is irreversible, independent of pH, and the maximum intensity current was observed at +1.20 V vs. AgCl/Ag at pH 1.9. A linear calibration line was obtained from 1.0x10-4 to 8.0x10-4 mol L-1 with SWV method. To complete the electrochemical knowledge of ETF pesticide, the reduction was also explored with HMDE. A well-defined peak was observed at –1.00V vs. AgCl/Ag in a large range of pH with higher signal at pH 7.0. Linearity was obtained in 4.2x10-6 and 9.4x10-6 mol L-1 ETF concentration range. An immediate alkaline hydrolysis of ETF was executed, producing a phenolic compound (2-ethylthiomethylphenol) (EMP), and the electrochemical activity of the product was examined. It was deduced that it is oxidized on GCE at +0.75V vs. AgCl/Ag with a maximum peak intensity current at pH 3.2, but the compound had no reduction activity on HMDE. Using the decrease of potential peak, a flow injection analysis (FIA) system was developed connected to an amperometric detector, enabling the determination of EMP over concentration range of 1.0x10-7 and 1.0x10-5 mol L-1 at a sampling rate of 60 h-1. The results provided by FIA methodology were performed by comparison with results from high-performance liquid chromatography (HPLC) technique and demonstrated good agreement with relative deviations lower than 4%. Recovery trials were performed and the obtained values were between 98 and 104%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The characteristic topographical features (crystallite dimensions, surface morphology and roughness) of bioceramics may influence the adsorption of proteins relevant to bone regeneration. This work aims at analyzing the influence of two distinct nanophased hydroxyapatite (HA) ceramics, HA725 and HA1000 on fibronectin (FN) and osteonectin (ON) adsorption and MC3T3-E1 osteoblast adhesion and morphology. Both substrates were obtained using the same hydroxyapatite nanocrystals aggregates and applying the sintering temperatures of 725ºC and 1000ºC, respectively. The two proteins used in this work, FN as an adhesive glycoprotein and ON as a counter-adhesive protein, are known to be involved in the early stages of osteogenesis (cell adhesion, mobility and proliferation). The properties of the nanoHA substrates had an important role in the adsorption behavior of the two studied proteins and clearly affected the MC3T3- E1 morphology, distribution and metabolic activity. HA1000 surfaces presenting slightly larger grain size, higher root-mean-square roughness (Rq), lower surface area and porosity, allowed for higher amounts of both proteins adsorbed. These substrates also revealed increased number of exposed FN cell-binding domains as well as higher affinity for osteonectin. Regarding the osteoblast adhesion results, improved viability and cell number were found for HA1000 surfaces as compared to HA725 ones, independently of the presence or type of adsorbed protein. Therefore the osteoblast adhesion and metabolic activity seemed to be more sensitive to surfaces morphology and roughness than to the type of adsorbed proteins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Ramo de especialização: Intervenção Cardiovascular

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A norfloxacina e o trimetoprim são dois antibióticos antibacterianos usados para o tratamento de infeções urinárias, intestinais e respiratórias. A maioria dos fármacos exige uma dosagem que garanta os níveis de segurança e eficácia de atuação. A necessidade de dosear os medicamentos e os seus metabolitos é assim um controlo imperioso e em muitos casos regular no tratamento de um paciente. Neste trabalho desenvolveram-se dois sensores eletroquímicos para a deteção da norfloxacina (NFX) e do trimetoprim (TMP), usando como superfície de suporte o carbono vítreo. A busca de novos materiais que conferiram maior seletividade e sensibilidade aos sistemas de deteção e por outro lado apresentem menores riscos para o paciente quando usados em dispositivos que permitam uma análise point-of-care, é especialmente importante e pode ser uma parte crucial do processo de decisão clínica. Assim, os polímeros molecularmente impresos enquadram-se nesse perfil e o seu uso tem vindo a ser cada vez mais avaliado. A impressão molecular é uma tecnologia capaz de produzir polímeros que incorporam as moléculas do analito e que após remoção por solventes específicos, permitem dotá-los de locais específicos de reconhecimento estereoquímico. A seleção do pirrol como polímero molecularmente impresso (MIP) permitiu construir com sucesso os sensores para doseamento dos antibióticos. A fim de aumentar a sensibilidade do método incorporou-se grafeno na superfície do elétrodo. Este material tem vindo a ser largamente utilizado devido às suas propriedades: estrutura molecular, condutividade elétrica e aumento da superfície são algumas das características que mais despertam o interesse para a sua aplicação neste projeto. Os sensores desenvolvidos foram incorporados em sistemas eletroquímicos. Os métodos voltamétricos aplicados foram a voltametria cíclica, a voltametria de onda quadrada e ainda a impedância. As condições de análise foram otimizadas no que respeita à polimerização do pirrol (concentração do polímero, número de ciclos de eletropolimerização e respetivos potenciais aplicados, tempo de incubação, solvente de remoção do analito), ao pH da solução do fármaco, à gama de concentrações dos antibióticos e aos parâmetros voltamétricos dos métodos de análise. Para cada um dos antibióticos um elétrodo não-impresso foi também preparado, usando o procedimento de polimerização mas sem a presença da molécula do analito, e foi usado como controlo. O sensor desenvolvido para o trimetoprim foi usado no doseamento do fármaco em amostras de urina. As amostras foram analisadas sem qualquer diluição, apenas foram centrifugadas para remoção de proteínas e algum interferente. Os sensores construídos apresentaram comportamento linear na gama de concentrações entre 102 e 107 mol/L. Os resultados mostram boa precisão (desvios padrão inferiores a 11%) e os limites de deteção foram de 8,317 e 1,307 mol/L para a norfloxacina e o trimetoprim, respetivamente. Para validação do método foram ainda efetuados ensaios de recuperação tendo obtido valores superiores a 94%.