990 resultados para simultaneous multicomponent analysis
Resumo:
The influence of Anatasa/Rutile ratio on TiO2 films, grown by electrophoretic deposition was studied in the photoassisted electrolytic copper ions removal from cyanide solutions. The proper dispersant dosage allowing the simultaneous electrophoretic deposition of Anatase and Rutile was chosen based on electrokinetic measurements; evidenced by the XRD spectra of the formed films. The evaluation of films photoassisted electrolytic copper ion removal showeds that it is possible to enhance the activity of Anatase films by adding some Rutile exploiting the synergetic interaction between these two materials, achieve by its proper deposition.
Resumo:
A simple and sensitive spectrophotometric method is proposed for the simultaneous determination of protocatechuic acid and protocatechuic aldehyde. The method is based on the difference in the kinetic rates of the reactions of analytes with [Ag(NH3)2]+ in the presence of polyvinylpyrrolidone to produce silver nanoparticles. The data obtained were processed by chemometric methods using principal component analysis artificial neural network and partial least squares. Excellent linearity was obtained in the concentration ranges of 1.23-58.56 µg mL-1 and 0.08-30.39 µg mL-1 for PAC and PAH, respectively. The limits of detection for PAC and PAH were 0.039 and 0.025 µg mL-1, respectively.
Resumo:
A direct spectrophotometric method for simultaneous determination of Co(II) and Ni(II), with diethanoldithiocarbamate (DEDC) as complexing agent, is proposed using the maximum absorption at 360 and 638 nm (Co(II)/DEDC) and 390 nm (Ni/DEDC). Adjusting the best metal/ligand ratio, supporting eletrolite, pH, and time of analysis, linear analytical curves from 1.0 10-6-4.0 10-4 for Co(II) in the presence of Ni 1.0 10-6-1.0 10-4 mol L-1 were observed. No further treatment or calculation processes have been necessary. Recoveries in different mixing ratios were of 99%. Interference of Fe(III), Cu(II), Zn(II) and Cd(II), and anions as NO3-, Cl-, ClO4-, citrate and phosphate has been evaluated. The method was applied to natural waters spiked with the cations.
Resumo:
The aim of this work was to develop and validate simple, accurate and precise spectroscopic methods (multicomponent, dual wavelength and simultaneous equations) for the simultaneous estimation and dissolution testing of ofloxacin and ornidazole tablet dosage forms. The medium of dissolution used was 900 ml of 0.01N HCl, using a paddle apparatus at a stirring rate of 50 rpm. The drug release was evaluated by developed and validated spectroscopic methods. Ofloxacin and ornidazole showed 293.4 and 319.6nm as λmax in 0.01N HCl. The methods were validated to meet requirements for a global regulatory filing. The validation included linearity, precision and accuracy. In addition, recovery studies and dissolution studies of three different tablets were compared and the results obtained show no significant difference among products.
Resumo:
This paper deals with the use of the conjugate gradient method of function estimation for the simultaneous identification of two unknown boundary heat fluxes in parallel plate channels. The fluid flow is assumed to be laminar and hydrodynamically developed. Temperature measurements taken inside the channel are used in the inverse analysis. The accuracy of the present solution approach is examined by using simulated measurements containing random errors, for strict cases involving functional forms with discontinuities and sharp-corners for the unknown functions. Three different types of inverse problems are addressed in the paper, involving the estimation of: (i) Spatially dependent heat fluxes; (ii) Time-dependent heat fluxes; and (iii) Time and spatially dependent heat fluxes.
Resumo:
This study has aimed to develop a method for simultaneous extraction and determination by liquid chromatography and mass spectrometry (LC-MS/MS) of glyphosate, aminomethylphosphonic acid (AMPA), shikimic acid, quinic acid, phenylalanine, tyrosine and tryptophan. For the joint analysis of these compounds the best conditions of ionization in mass spectrometry and for chromatographic separation of the compounds were selected. Calibration curves and linearity ranges were also determined for each compound. Different extraction systems of the compounds were tested from plant tissues collected from sugarcane (Saccharum officinarum) and eucalyptus (Eucalyptus urophylla platiphylla) plants two days after the glyphosate application at the dose of 720 g a.e. ha-1. The plant material was dried in a forced air circulation drying oven and in a lyophilizer, and subsequently the extractions with acidified water (pH 2.5), acetonitrile-water (50:50) [v/v] and methanol-water (50:50) [v/v] were tested. To verify the recovery of the compounds in the plant matrix with acidified water as an extracting solution, the samples were fortified with a solution containing the mixture of the different analytical standards present so that this one presented the same levels of 50 and 100 μg L-1 of each compound. All experiments were conducted with three replicates. The analytical method developed was efficient for compounds quantifications. The extraction from the samples dried in an oven and using acidified water allowed better extraction levels for all compounds. The recovery levels of the compounds in the fortified samples with known amounts of each compound for both plants samples were rather satisfactory.
Resumo:
Two different pathogenetic mechanisms are proposed for colorectal cancers. One, the so-called "classic pathway", is the most common and depends on multiple additive mutational events (germline and/or somatic) in tumor suppressor genes and oncogenes, frequently involving chromosomal deletions in key genomic regions. Methodologically this pathway is recognizable by the phenomenon of loss of heterozygosity. On the other hand, the "mutator pathway" depends on early mutational loss of the mismatch repair system (germline and/or somatic) leading to accelerated accumulation of gene mutations in critical target genes and progression to malignancy. Methodologically this second pathway is recognizable by the phenomenon of microsatellite instability. The distinction between these pathways seems to be more than academic since there is evidence that the tumors emerging from the mutator pathway have a better prognosis. We report here a very simple methodology based on a set of tri-, tetra- and pentanucleotide repeat microsatellites allowing the simultaneous study of microsatellite instability and loss of heterozygosity which could allocate 70% of the colorectal tumors to the classic or the mutator pathway. The ease of execution of the methodology makes it suitable for routine clinical typing
Resumo:
With the aim of investigating the presence of latent inflammatory process in the lungs of patients with Crohn's disease, 15 patients with Crohn's disease were evaluated by spirometry, the methacholine challenge test, induced sputum, and skin tests for inhaled antigens. Serum IgE, erythrocyte sedimentation rate and hematocrit were also determined. The patients were compared with 20 healthy controls by the Mann-Whitney and Fisher exact tests. Their respiratory physical examination was normal. None had a personal or family history of clinical atopy. None had a previous history of pulmonary disease, smoking or toxic bronchopulmonary exposure. None had sinusitis, migraine, diabetes mellitus, or cardiac failure. Four (26.6%) of the patients with Crohn's disease had a positive methacholine challenge test whereas none of the 20 controls had a positive methacholine test (P = 0.026, Fisher exact test). Patients with Crohn's disease had a higher level of lymphocytes in induced sputum than controls (mean 14.59%, range 3.2-50 vs 5.46%, 0-26.92%, respectively; P = 0.011, Mann-Whitney test). Patients with Crohn's disease and a positive methacholine challenge test had an even higher percentage of lymphocytes in induced sputum compared with patients with Crohn's disease and a negative methacholine test (mean 24.88%, range 12.87-50 vs 10.48%, 3.2-21.69%; P = 0.047, Mann-Whitney test). The simultaneous findings of bronchopulmonary lymphocytosis and bronchial hyperresponsiveness in patients with Crohn's disease were not reported up to now. These results suggest that patients with Crohn's disease present a subclinical inflammatory process despite the absence of pulmonary symptoms.
Resumo:
Hereditary hemochromatosis (HH) is a common autosomal disorder of iron metabolism mainly affecting Caucasian populations. Three recurrent disease-associated mutations have been detected in the hemochromatosis gene (HFE): C282Y, H63D, and S65C. Although HH phenotype has been associated with all three mutations, C282Y is considered the most relevant mutation responsible for hemochromatosis. Clinical complications of HH include cirrhosis of the liver, congestive cardiac failure and cardiac arrhythmias, endocrine pancreatic disease, which can be prevented by early diagnosis and treatment. Therefore, a reliable genotyping method is required for presymptomatic diagnosis. We describe the simultaneous detection of the C282Y, H63D and S65C mutations in the hemochromatosis gene by real-time PCR followed by melting curve analysis using fluorescence resonance energy transfer (FRET) probes. The acceptor fluorophore may be replaced by a quencher, increasing multiplex possibilities. Real-time PCR results were compared to the results of sequencing and conventional PCR followed by restriction digestion and detection by agarose gel electrophoresis (PCR-RFLP). Genotypes from 80 individuals obtained both by the conventional PCR-RFLP method and quenched-FRET real-time PCR were in full agreement. Sequencing also confirmed the results obtained by the new method, which proved to be an accurate, rapid and cost-effective diagnostic assay. Our findings demonstrate the usefulness of real-time PCR for the simultaneous detection of mutations in the HFE gene, which allows a reduction of a significant amount of time in sample processing compared to the PCR-RFLP method, eliminates the use of toxic reagents, reduces the risk of contamination in the laboratory, and enables full process automation.
Resumo:
Simultaneous measurements of EEG-functional magnetic resonance imaging (fMRI) combine the high temporal resolution of EEG with the distinctive spatial resolution of fMRI. The purpose of this EEG-fMRI study was to search for hemodynamic responses (blood oxygen level-dependent - BOLD responses) associated with interictal activity in a case of right mesial temporal lobe epilepsy before and after a successful selective amygdalohippocampectomy. Therefore, the study found the epileptogenic source by this noninvasive imaging technique and compared the results after removing the atrophied hippocampus. Additionally, the present study investigated the effectiveness of two different ways of localizing epileptiform spike sources, i.e., BOLD contrast and independent component analysis dipole model, by comparing their respective outcomes to the resected epileptogenic region. Our findings suggested a right hippocampus induction of the large interictal activity in the left hemisphere. Although almost a quarter of the dipoles were found near the right hippocampus region, dipole modeling resulted in a widespread distribution, making EEG analysis too weak to precisely determine by itself the source localization even by a sophisticated method of analysis such as independent component analysis. On the other hand, the combined EEG-fMRI technique made it possible to highlight the epileptogenic foci quite efficiently.
Resumo:
The aim of this study was to contribute to the current knowledge-based theory by focusing on a research gap that exists in the empirically proven determination of the simultaneous but differentiable effects of intellectual capital (IC) assets and knowledge management (KM) practices on organisational performance (OP). The analysis was built on the past research and theoreticised interactions between the latent constructs specified using the survey-based items that were measured from a sample of Finnish companies for IC and KM and the dependent construct for OP determined using information available from financial databases. Two widely used and commonly recommended measures in the literature on management science, i.e. the return on total assets (ROA) and the return on equity (ROE), were calculated for OP. Thus the investigation of the relationship between IC and KM impacting OP in relation to the hypotheses founded was possible to conduct using objectively derived performance indicators. Using financial OP measures also strengthened the dynamic features of data needed in analysing simultaneous and causal dependences between the modelled constructs specified using structural path models. The estimates were obtained for the parameters of structural path models using a partial least squares-based regression estimator. Results showed that the path dependencies between IC and OP or KM and OP were always insignificant when analysed separate to any other interactions or indirect effects caused by simultaneous modelling and regardless of the OP measure used that was either ROA or ROE. The dependency between the constructs for KM and IC appeared to be very strong and was always significant when modelled simultaneously with other possible interactions between the constructs and using either ROA or ROE to define OP. This study, however, did not find statistically unambiguous evidence for proving the hypothesised causal mediation effects suggesting, for instance, that the effects of KM practices on OP are mediated by the IC assets. Due to the fact that some indication about the fluctuations of causal effects was assessed, it was concluded that further studies are needed for verifying the fundamental and likely hidden causal effects between the constructs of interest. Therefore, it was also recommended that complementary modelling and data processing measures be conducted for elucidating whether the mediation effects occur between IC, KM and OP, the verification of which requires further investigations of measured items and can be build on the findings of this study.
Resumo:
Order parameter profiles extracted from the NMR spectra of model membranes are a valuable source of information about their structure and molecular motions. To al1alyze powder spectra the de-Pake-ing (numerical deconvolution) ~echnique can be used, but it assumes a random (spherical) dist.ribution of orientations in the sample. Multilamellar vesicles are known to deform and orient in the strong magnetic fields of NMR magnets, producing non-spherical orientation distributions. A recently developed technique for simultaneously extracting the anisotropies of the system as well as the orientation distributions is applied to the analysis of partially magnetically oriented 31p NMR spectra of phospholipids. A mixture of synthetic lipids, POPE and POPG, is analyzed to measure distortion of multilamellar vesicles in a magnetic field. In the analysis three models describing the shape of the distorted vesicles are examined. Ellipsoids of rotation with a semiaxis ratio of about 1.14 are found to provide a good approximation of the shape of the distorted vesicles. This is in reasonable agreement with published experimental work. All three models yield clearly non-spherical orientational distributions, as well as a precise measure of the anisotropy of the chemical shift. Noise in the experimental data prevented the analysis from concluding which of the three models is the best approximation. A discretization scheme for finding stability in the algorithm is outlined
Resumo:
In this paper, we use identification-robust methods to assess the empirical adequacy of a New Keynesian Phillips Curve (NKPC) equation. We focus on the Gali and Gertler’s (1999) specification, on both U.S. and Canadian data. Two variants of the model are studied: one based on a rationalexpectations assumption, and a modification to the latter which consists in using survey data on inflation expectations. The results based on these two specifications exhibit sharp differences concerning: (i) identification difficulties, (ii) backward-looking behavior, and (ii) the frequency of price adjustments. Overall, we find that there is some support for the hybrid NKPC for the U.S., whereas the model is not suited to Canada. Our findings underscore the need for employing identificationrobust inference methods in the estimation of expectations-based dynamic macroeconomic relations.
Resumo:
Contexte & Objectifs : La manométrie perfusée conventionnelle et la manométrie haute résolution (HRM) ont permis le développement d’une variété de paramètres pour mieux comprendre la motilité de l'œsophage et quantifier les caractéristiques de la jonction œsophago-gastrique (JOG). Cependant, l'anatomie de la JOG est complexe et les enregistrements de manométrie détectent à la fois la pression des structures intrinsèques et des structures extrinsèques à l'œsophage. Ces différents composants ont des rôles distincts au niveau de la JOG. Les pressions dominantes ainsi détectées au niveau de la JOG sont attribuables au sphincter œsophagien inférieur (SOI) et aux piliers du diaphragme (CD), mais aucune des technologies manométriques actuelles n’est capable de distinguer ces différents composants de la JOG. Lorsqu’on analyse les caractéristiques de la JOG au repos, celle ci se comporte avant tout comme une barrière antireflux. Les paramètres manométriques les plus couramment utilisés dans ce but sont la longueur de la JOG et le point d’inversion respiratoire (RIP), défini comme le lieu où le pic de la courbe de pression inspiratoire change de positif (dans l’abdomen) à négatif (dans le thorax), lors de la classique manœuvre de « pull-through ». Cependant, l'importance de ces mesures reste marginale comme en témoigne une récente prise de position de l’American Gastroenterology Association Institute (AGAI) (1) qui concluait que « le rôle actuel de la manométrie dans le reflux gastro-œsophagien (RGO) est d'exclure les troubles moteurs comme cause des symptômes présentés par la patient ». Lors de la déglutition, la mesure objective de la relaxation de la JOG est la pression de relaxation intégrée (IRP), qui permet de faire la distinction entre une relaxation normale et une relaxation anormale de la JOG. Toutefois, puisque la HRM utilise des pressions moyennes à chaque niveau de capteurs, certaines études de manométrie laissent suggérer qu’il existe une zone de haute pression persistante au niveau de la JOG même si un transit est mis en évidence en vidéofluoroscopie. Récemment, la manométrie haute résolution « 3D » (3D-HRM) a été développée (Given Imaging, Duluth, GA) avec le potentiel de simplifier l'évaluation de la morphologie et de la physiologie de la JOG. Le segment « 3D » de ce cathéter de HRM permet l'enregistrement de la pression à la fois de façon axiale et radiale tout en maintenant une position fixe de la sonde, et évitant ainsi la manœuvre de « pull-through ». Par conséquent, la 3D-HRM devrait permettre la mesure de paramètres importants de la JOG tels que sa longueur et le RIP. Les données extraites de l'enregistrement fait par 3D-HRM permettraient également de différencier les signaux de pression attribuables au SOI des éléments qui l’entourent. De plus, l’enregistrement des pressions de façon radiaire permettrait d’enregistrer la pression minimale de chaque niveau de capteurs et devrait corriger cette zone de haute pression parfois persistante lors la déglutition. Ainsi, les objectifs de ce travail étaient: 1) de décrire la morphologie de la JOG au repos en tant que barrière antireflux, en comparant les mesures effectuées avec la 3D-HRM en temps réel, par rapport à celle simulées lors d’une manœuvre de « pull-through » et de déterminer quelles sont les signatures des pressions attribuables au SOI et au diaphragme; 2) d’évaluer la relaxation de la JOG pendant la déglutition en testant l'hypothèse selon laquelle la 3D-HRM permet le développement d’un nouveau paradigme (appelé « 3D eSleeve ») pour le calcul de l’IRP, fondé sur l’utilisation de la pression radiale minimale à chaque niveau de capteur de pression le long de la JOG. Ce nouveau paradigme sera comparé à une étude de transit en vidéofluoroscopie pour évaluer le gradient de pression à travers la JOG. Méthodes : Nous avons utilisé un cathéter 3D-HRM, qui incorpore un segment dit « 3D » de 9 cm au sein d’un cathéter HRM par ailleurs standard. Le segment 3D est composé de 12 niveaux (espacés de 7.5mm) de 8 capteurs de pression disposés radialement, soit un total de 96 capteurs. Neuf volontaires ont été étudiés au repos, où des enregistrements ont été effectués en temps réel et pendant une manœuvre de « pull-through » du segment 3D (mobilisation successive du cathéter de 5 mm, pour que le segment 3D se déplace le long de la JOG). Les mesures de la longueur du SOI et la détermination du RIP ont été réalisées. La longueur de la JOG a été mesurée lors du « pull-through » en utilisant 4 capteurs du segment 3D dispersés radialement et les marges de la JOG ont été définies par une augmentation de la pression de 2 mmHg par rapport à la pression gastrique ou de l’œsophage. Pour le calcul en temps réel, les limites distale et proximale de la JOG ont été définies par une augmentation de pression circonférentielle de 2 mmHg par rapport à la pression de l'estomac. Le RIP a été déterminée, A) dans le mode de tracé conventionnel avec la méthode du « pull-through » [le RIP est la valeur moyenne de 4 mesures] et B) en position fixe, dans le mode de représentation topographique de la pression de l’œsophage, en utilisant l’outil logiciel pour déterminer le point d'inversion de la pression (PIP). Pour l'étude de la relaxation de la JOG lors de la déglutition, 25 volontaires ont été étudiés et ont subi 3 études de manométrie (10 déglutitions de 5ml d’eau) en position couchée avec un cathéter HRM standard et un cathéter 3D-HRM. Avec la 3D-HRM, l’analyse a été effectuée une fois avec le segment 3D et une fois avec une partie non 3D du cathéter (capteurs standard de HRM). Ainsi, pour chaque individu, l'IRP a été calculée de quatre façons: 1) avec la méthode conventionnelle en utilisant le cathéter HRM standard, 2) avec la méthode conventionnelle en utilisant le segment standard du cathéter 3D-HRM, 3) avec la méthode conventionnelle en utilisant le segment « 3D » du cathéter 3D-HRM, et 4) avec le nouveau paradigme (3D eSleeve) qui recueille la pression minimale de chaque niveau de capteurs (segment 3D). Quatorze autres sujets ont subi une vidéofluoroscopie simultanée à l’étude de manométrie avec le cathéter 3D-HRM. Les données de pression ont été exportés vers MATLAB ™ et quatre pressions ont été mesurées simultanément : 1) la pression du corps de l’œsophage, 2cm au-dessus de la JOG, 2) la pression intragastrique, 3) la pression radiale moyenne de la JOG (pression du eSleeve) et 4) la pression de la JOG en utilisant la pression minimale de chaque niveau de capteurs (pression du 3D eSleeve). Ces données ont permis de déterminer le temps permissif d'écoulement du bolus (FPT), caractérisé par la période au cours de laquelle un gradient de pression existe à travers la JOG (pression œsophagienne > pression de relaxation de la JOG > pression gastrique). La présence ou l'absence du bolus en vidéofluoroscopie et le FPT ont été codés avec des valeurs dichotomiques pour chaque période de 0,1 s. Nous avons alors calculé la sensibilité et la spécificité correspondant à la valeur du FPT pour la pression du eSleeve et pour la pression du 3D eSleeve, avec la vidéofluoroscopie pour référence. Résultats : Les enregistrements avec la 3D-HRM laissent suggérer que la longueur du sphincter évaluée avec la méthode du « pull-through » était grandement exagéré en incorporant dans la mesure du SOI les signaux de pression extrinsèques à l’œsophage, asymétriques et attribuables aux piliers du diaphragme et aux structures vasculaires. L’enregistrement en temps réel a permis de constater que les principaux constituants de la pression de la JOG au repos étaient attribuables au diaphragme. L’IRP calculé avec le nouveau paradigme 3D eSleeve était significativement inférieur à tous les autres calculs d'IRP avec une limite supérieure de la normale de 12 mmHg contre 17 mmHg pour l’IRP calculé avec la HRM standard. La sensibilité (0,78) et la spécificité (0,88) du 3D eSleeve étaient meilleurs que le eSleeve standard (0,55 et 0,85 respectivement) pour prédire le FPT par rapport à la vidéofluoroscopie. Discussion et conclusion : Nos observations suggèrent que la 3D-HRM permet l'enregistrement en temps réel des attributs de la JOG, facilitant l'analyse des constituants responsables de sa fonction au repos en tant que barrière antireflux. La résolution spatiale axiale et radiale du segment « 3D » pourrait permettre de poursuivre cette étude pour quantifier les signaux de pression de la JOG attribuable au SOI et aux structures extrinsèques (diaphragme et artéfacts vasculaires). Ces attributs du cathéter 3D-HRM suggèrent qu'il s'agit d'un nouvel outil prometteur pour l'étude de la physiopathologie du RGO. Au cours de la déglutition, nous avons évalué la faisabilité d’améliorer la mesure de l’IRP en utilisant ce nouveau cathéter de manométrie 3D avec un nouveau paradigme (3D eSleeve) basé sur l’utilisation de la pression radiale minimale à chaque niveau de capteurs de pression. Nos résultats suggèrent que cette approche est plus précise que celle de la manométrie haute résolution standard. La 3D-HRM devrait certainement améliorer la précision des mesures de relaxation de la JOG et cela devrait avoir un impact sur la recherche pour modéliser la JOG au cours de la déglutition et dans le RGO.
Resumo:
The transient interaction between a refraction index grating and light beams during simultaneous writing and thermal fixing of a photorefractive hologram is investigated. With a diffusion- and photovoltaic-dominated carrier transport mechanism and carrier thermal activation (temperature dependent) considered in Fe:LiNbO3 crystal, from the standpoint of field-material coupling, the theoretical thermal fixing time and the space-charge field buildup, spatial distribution, and temperature dependence are given numerically by combining the band transport model with mobile ions with the coupled-wave equation