980 resultados para seedless table grapes
Resumo:
The objective of this work was to determine the most appropriated chemical treatment to be used to dry grapes cv. Rubi for raisin production. Drying curves for convective drying with air at 50ºC, in a tray drier, were obtained for grapes submitted to chemical pretreatments with different concentrations of potassium carbonate and olive oil, and different dipping times, according to factorial designs. Convective drying curves were also obtained for grapes pretreated in aqueous suspensions of soybean lecithin, at varied lecithin concentrations and dipping times. Page model was adjusted to the experimental drying curves, and the calculated drying times showed that the best pretreatment consisted in dipping grapes for 2 minutes in a 5% olive oil and 6% K2CO3 emulsion, at 50ºC, which resulted in a drying time close to that of the pretreatment with 2.5% of olive oil, but with a lower consumption of this substance. In addition, the immersion of grapes in an aqueous suspension of 2% soy lecithin, at 50ºC, for 5 minutes, resulted in a total drying time slightly higher than the most effective pretreatment.
Resumo:
Este estudio fue dirigido para evaluar la relación agua-rendimiento en vid de mesa cv. Crimson y establecer valores críticos para las mediciones del estado hídrico de las plantas. Los estudios de campo se desarrollaron durante tres años, en el Valle de Aconcagua, Chile, a 32º47'S y 70º42'O, en un suelo de textura franco arcillosa. Se proporcionaron a las plantas diferentes cantidades de agua de riego entre 40 y 100% de la evapotranspiración del cultivo (Etc). El potencial hídrico xilemático medido a mediodía (psixmin) y la conductancia estomática estuvieron estrechamente relacionados con el déficit de agua impuesto y el rendimiento obtenido. Los rendimientos de la vid disminuyeron respecto al agua aplicada en el rango de los tratamientos estudiados. Sesenta por ciento de restricción de la Etc redujo 22% del rendimiento. Cuando la planta mantuvo psixmin mayor que -0,75 MPa entre cuaja y pinta, la producción y los calibres fueron mayores.
Resumo:
Acquis le 28 novembre 1821 de M. Renard de la Savonnerie, avec 6 autres mss., pour le prix global de 600 francs; cf. B.n.F., département des Manuscrits, Archives Modernes 492ter, registre des acquisitions du département des Manuscrits 1821-1830, f. 41 "Relief de chartes de l'abbaye de Longpont, un vol. 8°"; nouv. acq. fr. 5530.
Resumo:
[Acte. 1759-01-19. Paris]
Desempenho agronômico das videiras 'Crimson Seedless' e 'Superior Seedless' no norte de Minas Gerais
Resumo:
O objetivo deste trabalho foi avaliar a influência do vigor dos porta-enxertos '1103 Paulsen' e 'IAC-572 Jales', no desempenho agronômico das cultivares Crimson Seedless e Superior Seedless. O experimento foi realizado na Fazenda Experimental da Epamig, em Mocambinho, distrito de Jaíba, MG, em delineamento inteiramente casualizado com sete repetições em esquema fatorial 2x2. Foram analisadas a fertilidade de gemas, o número e a massa de cachos e a massa de ramos. O porta-enxerto '1103 Paulsen' proporcionou os melhores resultados nas cultivares Crimson Seedless e Superior Seedless quanto à massa e número de cachos por planta e fertilidade de gemas, com produtividade média de 31,9 e 22,4 t ha-1 ano-1 , respectivamente. O porta-enxerto 'IAC-572 Jales' proporcionou maior vigor, com maior massa de ramos por planta nas duas cultivares. O porta-enxerto '1103 Paulsen' induziu a maiores fertilidade de gemas e produtividades em 'Crimson Seedless' e 'Superior Seedless' e pode ser indicado para o cultivo na região de Jaíba, MG.
Resumo:
Following the success of the first round table in 2001, the Swiss Proteomic Society has organized two additional specific events during its last two meetings: a proteomic application exercise in 2002 and a round table in 2003. Such events have as their main objective to bring together, around a challenging topic in mass spectrometry, two groups of specialists, those who develop and commercialize mass spectrometry equipment and software, and expert MS users for peptidomics and proteomics studies. The first round table (Geneva, 2001) entitled "Challenges in Mass Spectrometry" was supported by brief oral presentations that stressed critical questions in the field of MS development or applications (Stöcklin and Binz, Proteomics 2002, 2, 825-827). Topics such as (i) direct analysis of complex biological samples, (ii) status and perspectives for MS investigations of noncovalent peptide-ligant interactions; (iii) is it more appropriate to have complementary instruments rather than a universal equipment, (iv) standardization and improvement of the MS signals for protein identification, (v) what would be the new generation of equipment and finally (vi) how to keep hardware and software adapted to MS up-to-date and accessible to all. For the SPS'02 meeting (Lausanne, 2002), a full session alternative event "Proteomic Application Exercise" was proposed. Two different samples were prepared and sent to the different participants: 100 micro g of snake venom (a complex mixture of peptides and proteins) and 10-20 micro g of almost pure recombinant polypeptide derived from the shrimp Penaeus vannamei carrying an heterogeneous post-translational modification (PTM). Among the 15 participants that received the samples blind, eight returned results and most of them were asked to present their results emphasizing the strategy, the manpower and the instrumentation used during the congress (Binz et. al., Proteomics 2003, 3, 1562-1566). It appeared that for the snake venom extract, the quality of the results was not particularly dependant on the strategy used, as all approaches allowed Lication of identification of a certain number of protein families. The genus of the snake was identified in most cases, but the species was ambiguous. Surprisingly, the precise identification of the recombinant almost pure polypeptides appeared to be much more complicated than expected as only one group reported the full sequence. Finally the SPS'03 meeting reported here included a round table on the difficult and challenging task of "Quantification by Mass Spectrometry", a discussion sustained by four selected oral presentations on the use of stable isotopes, electrospray ionization versus matrix-assisted laser desorption/ionization approaches to quantify peptides and proteins in biological fluids, the handling of differential two-dimensional liquid chromatography tandem mass spectrometry data resulting from high throughput experiments, and the quantitative analysis of PTMs. During these three events at the SPS meetings, the impressive quality and quantity of exchanges between the developers and providers of mass spectrometry equipment and software, expert users and the audience, were a key element for the success of these fruitful events and will have definitively paved the way for future round tables and challenging exercises at SPS meetings.