980 resultados para screening method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes an analytical method for the rapid screening and identification of the phenolic constituents present in the polar extracts of different Lychnophora spp. using LC-UV/DAD-ESI-MS and LC-UV/DAD-ESI-MS/MS. Compounds were identified based on UV, retention time, MS experiments and MS/MS of precursor ion or standard. On-line phytochemical investigation of Lychnophora spp. allowed for the identification of flavonoids, chlorogenic acid derivatives and lactones. Some of the observed compounds were for the first time identified in Lychnophora species in a fast analytical procedure. The data obtained here may be helpful to the investigation of polar constituents from other Lychnophora species.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel screening strategy has been developed for the identification of alpha-chymotrypsin inhibitors from a phage peptide library. In this strategy, the standard affinity selection protocol was modified by adding a proteolytic cleavage period to avoid recovery of alpha-chymotrypsin substrates. After four cycles of selection and further activity assay, a group of related peptides were identified by DNA sequencing. These peptides share a consensus sequence motif as (S/T)RVPR(R/H). Then, a corresponding short peptide (Ac-ASRVPRRG-NH2) was synthesized chemically and proved to be an inhibitor of alpha-chymotrypsin. The present work provides a useful way for searching proteinase inhibitors without detailed knowledge of the molecular structure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. The purpose of this study was to determine whether the Hopkins Verbal Learning Test (HVLT) could be used as a valid and reliable screening test for mild dementia in older people, and to compare its performance to that of the Mini-Mental State Examination (MMSE). Method. Using a cross-sectional design, we studied three groups of older subjects recruited from a district geriatric psychiatry service: (1) 26 patients with DSM-IV dementia and MMSE scores of 18 or better; (2) 15 patients with psychiatric diagnoses other than dementia; and (3) 15 normal controls. The relationship of each potential cutting point on the HVLT and the MMSE was examined against the independently ascertained DSM-IV diagnoses of dementia using a Receiver Operating Characteristic (ROC) analysis. Results. The subjects consisted of 21 (37.5%) males and 35 (62.5%) females with a mean age of 74.7 (SD 6.1) years and a mean of 8.5 (SD 1.8) years of formal education. ROC analysis indicated that the optimal cutting point for detecting mild dementia in this group of subjects using the HVLT was 18/19 (sensitivity = 0.96, specificity = 0.80) and using the MMSE was 25/26 (sensitivity = 0.88, specificity = 0.93). Conclusions. The HVLT can be recommended as a valid and reliable screening test for mild dementia and as an adjunct in the clinical assessment of older people. The HVLT had better sensitivity than the MMSE in detecting patients with mild dementia, whereas the MMSE had better specificity. Copyright (C) 2000 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To examine differentials and time trends in self-reported Pap test rates by migrant status from the 1989/90 and 1995 Australian National Health Surveys (NHS). Method: Unit record data for females with the variables of interest were extracted from the 1989/90 and 1995 NHS and combined. The dichotomous outcome variables were 'ever had a Pap test and 'had a Pap test within three years'. The principal study factor was country-of-birth, but language spoken at home (English or not) was also examined. The indirect age-standardised screening ratio was used to calculate proportions of 'ever had a Pap test' and 'had a Pap test within three years' and differences were tested statistically using logistic regression analysis for each year of survey by migrant status. Results: Odds ratios for rates of reporting 'ever had a Pap test' were significantly lower in women born in southern Europe, Italy, other countries, southern Asia, Middle East, Greece and South-East Asia compared with Australian-born. Reported rates of 'ever had a Pap test' were significantly higher in the 1995 NHS (p

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Anemia screening before blood donation requires an accurate, quick, practical, and easy method with minimal discomfort for the donors. The aim of this study was to compare the accuracy of two quantitative methods of anemia screening: the HemoCue 201(+) (Aktiebolaget Leo Diagnostics) hemoglobin (Hb) and microhematocrit (micro-Hct) tests. Two blood samples of a single fingerstick were obtained from 969 unselected potential female donors to determine the Hb by HemoCue 201(+) and micro-Hct using HemataSTAT II (Separation Technology, Inc.), in alternating order. From each participant, a venous blood sample was drawn and run in an automatic hematology analyzer (ABX Pentra 60, ABX Diagnostics). Considering results of ABX Pentra 60 as true values, the sensitivity and specificity of HemoCue 201(+) and micro-Hct as screening methods were compared, using a venous Hb level of 12.0 g per dL as cutoff for anemia. The sensitivities of the HemoCue 201(+) and HemataSTAT II in detecting anemia were 56 percent (95% confidence interval [CI], 46.1%-65.5%) and 39.5 percent (95% CI, 30.2%-49.3%), respectively (p < 0.001). Analyzing only candidates with a venous Hb level lower than 11.0 g per dL, the deferral rate was 100 percent by HemoCue 201(+) and 77 percent by HemataSTAT II. The specificities of the methods were 93.5 and 93.2 percent, respectively. The HemoCue 201(+) showed greater discriminating power for detecting anemia in prospective blood donors than the micro-Hct method. Both presented equivalent deferral error rates of nonanemic potential donors. Compared to the micro-Hct, HemoCue 201(+) reduces the risk of anemic female donors giving blood, specially for those with lower Hb levels, without increasing the deferral of nonanemic potential donors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Antibody phage display libraries are a useful tool in proteomic analyses. This study evaluated an antibody recombinant library for identification of sex-specific proteins on the sperm cell surface. The Griffin.1 library was used to produce phage antibodies capable of recognizing membrane proteins from Nelore sperm cells. After producing soluble monoclonal scFv, clones were screened on Simental sperm cells by flow cytometry and those that bound to 40-60% of cells were selected. These clones were re-analyzed using Nelore sperm cells and all clones bound to 40-60% of cells. Positive clones were submitted to a binding assay against male and female bovine leukocytes by flow cytometry and one clone preferentially bound to male cells. The results indicate that phage display antibodies are an alternative method for identification of molecules markers on sperm cells. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High-throughput screening (HTS) using high-density microplates is the primary method for the discovery of novel lead candidate molecules. However, new strategies that eschew 2D microplate technology, including technologies that enable mass screening of targets against large combinatorial libraries, have the potential to greatly increase throughput and decrease unit cost. This review presents an overview of state-of-the-art microplate-based HTS technology and includes a discussion of emerging miniaturized systems for HTS. We focus on new methods of encoding combinatorial libraries that promise throughputs of as many as 100 000 compounds per second.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To examine associations between nutrition screening checklists and the health of older women. Design: Cross-sectional postal survey including measures of health and health service utilisation, as well as the Australian Nutrition Screening Initiative (ANSI), adapted from the Nutrition Screening Initiative (NSI). Setting: Australia, 1996. Subjects: In total, 12 939 women aged 70-75 years randomly selected as part of the Australian Longitudinal Study on Women's Health. Results: Responses to individual items in the ANSI checklist, and ANSI and NSI scores, were associated with measures of health and health service utilisation. Women with high ANSI and NSI scores had poorer physical and mental health, higher health care utilisation and were less likely to be in the acceptable weight range. The performance of an unweighted score (TSI) was also examined and showed similar results. Whereas ANSI classified 30% of the women as 'high-risk', only 13% and 12% were classified as 'high-risk' by the NSI and TSI, respectively. However, for identifying women with body mass index outside the acceptable range, sensitivity, specificity and positive predictive values for all of these checklists were less than 60%. Conclusions: Higher scores on both the ANSI and NSI are associated with poorer health. The simpler unweighted method of scoring the ANSI (TSI) showed better discrimination for the identification of 'at risk' women than the weighted ANSI method. The predictive value of individual items and the checklist scores need to be examined longitudinally.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to determine and evaluate the diagnostic accuracy of visual screening tests for detecting vision loss in elderly. This study is defined as study of diagnostic performance. The diagnostic accuracy of 5 visual tests -near convergence point, near accommodation point, stereopsis, contrast sensibility and amsler grid—was evaluated by means of the ROC method (receiver operating characteristics curves), sensitivity, specificity, positive and negative likelihood ratios (LR+/LR−). Visual acuity was used as the reference standard. A sample of 44 elderly aged 76.7 years (±9.32), who were institutionalized, was collected. The curves of contrast sensitivity and stereopsis are the most accurate (area under the curves were 0.814−p = 0.001, C.I.95%[0.653;0.975]— and 0.713−p = 0.027, C.I.95%[0,540;0,887], respectively). The scores with the best diagnostic validity for the stereopsis test were 0.605 (sensitivity 0.87, specificity 0.54; LR+ 1.89, LR−0.24) and 0.610 (sensitivity 0.81, specificity 0.54; LR+1.75, LR−0.36). The scores with higher diagnostic validity for the contrast sensibility test were 0.530 (sensitivity 0.94, specificity 0.69; LR+ 3.04, LR−0.09). The contrast sensitivity and stereopsis test's proved to be clinically useful in detecting vision loss in the elderly.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Cyclopid copepods are known to be good mosquito controllers, specially as regards the larvae of the dengue vectors Aedes aegypti and Ae. albopictus. MATERIAL AND METHOD: The objective of the study was to survey the local copepod fauna and search for new strains of M. longisetus var. longisetus, comparing the potential of the samples found with the current strain ML-01 against Ae. albopictus larvae, under laboratory conditions. Eleven bodies of water in Campinas, SP, Brazil, were screened for copepods by collecting 1.5 l of water from each of then. The predatory potential of adults copepods was evaluated over 24 h, in the laboratory, for groups of 5 individuals preying upon 30 first instar Ae. albopictus larvae. RESULTS AND CONCLUSION: The following cyclopid species were found: Metacyclops mendocinus, Tropocyclops prasinus, Eucyclops sp, Eucyclops serrulatus, Eucyclops solitarius, Eucyclops ensifer, Macrocyclops albidus var. albidus and Mesocyclops longisetus var. longisetus. The predatory potential of these copepods ranged from nil to 97.3%. A sample collected in the field containing only M. longisetus var. longisetus showed the best control efficiency with no significant difference from a three-year old laboratory culture (ML-01) of the same species evaluated for comparison. The sample with few M. albidus var. albidus was ranked in second place showing an average 25.9% efficiency. The use of copepods in trap tires as dengue vector controllers is discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Environmental pollution continues to be an emerging study field, as there are thousands of anthropogenic compounds mixed in the environment whose possible mechanisms of toxicity and physiological outcomes are of great concern. Developing methods to access and prioritize the screening of these compounds at trace levels in order to support regulatory efforts is, therefore, very important. A methodology based on solid phase extraction followed by derivatization and gas chromatography-mass spectrometry analysis was developed for the assessment of four endocrine disrupting compounds (EDCs) in water matrices: bisphenol A, estrone, 17b-estradiol and 17a-ethinylestradiol. The study was performed, simultaneously, by two different laboratories in order to evaluate the robustness of the method and to increase the quality control over its application in routine analysis. Validation was done according to the International Conference on Harmonisation recommendations and other international guidelines with specifications for the GC-MS methodology. Matrix-induced chromatographic response enhancement was avoided by using matrix-standard calibration solutions and heteroscedasticity has been overtaken by a weighted least squares linear regression model application. Consistent evaluation of key analytical parameters such as extraction efficiency, sensitivity, specificity, linearity, limits of detection and quantification, precision, accuracy and robustness was done in accordance with standards established for acceptance. Finally, the application of the optimized method in the assessment of the selected analytes in environmental samples suggested that it is an expedite methodology for routine analysis of EDC residues in water matrices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação de Mestrado, Mestrado em Ciências Biomédicas, 8 de Maio de 2015, Universidade dos Açores.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Growing concern about the contamination of wastewaters by antibiotics demands fast but sensitive analytical methodologies, for the screening of a large number of samples. The purpose of this work was to develop a simple methodology, using direct injection of the samples, by HPLC with diode array detection (DAD), for a multiresidue analysis of five antibiotics of different classes. Wastewater from an urban water treatment plant was selected as a model to study possible coelution of interfering compounds. The linearity interval ranged from 40 to 400 µg/L for amoxicillin (Amox), metronidazole (Metro), cefazolin (Cefa), and chloramphenicol (Chloram) and from 20 to 200 µg/L for sulfamethoxazole (Sulfa), with LODs lower than 14 µg/L. Repeatability, expressed by the CV of six repeated injections, ranged from 1 to 8%, while the intermediate precision varied between 2 and 11%. The recovery ranged from 90 to 109%. This method enables the fast screening of a large number of samples, with an expanded uncertainty in the 1–22% range. The advantage of the proposed method is to significantly reduce the number of samples to be analyzed by more complex methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An analytical method, based on microwave-assisted extraction and liquid chromatography with diode array detection, for the determination of six carbamate and three urea pesticides in fresh and processed tomato samples is described. Significant parameters affecting extraction efficiency were optimized. Under optimum microwave-assisted extraction conditions (20mL acetonitrile, for 10 minutes, at 60º C), pesticides were extracted with recoveries ranging from 57.6 to 102% (RSDs<7%). Quantification limits between 6.5 and 39.6 µg=kg were obtained. A total number of 28 different fresh tomato samples and 6 processed tomato products were analysed. Confirmation of suspicious samples was performed by LC-MS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new procedure for determining eleven organochlorine pesticides in soils using microwave-assisted extraction (MAE) and headspace solid phase microextraction (HS-SPME) is described. The studied pesticides consisted of mirex, α- and γ-chlordane, p,p’-DDT, heptachlor, heptachlor epoxide isomer A, γ-hexachlorocyclohexane, dieldrin, endrin, aldrine and hexachlorobenzene. The HS-SPME was optimized for the most important parameters such as extraction time, sample volume and temperature. The present analytical procedure requires a reduced volume of organic solvents and avoids the need for extract clean-up steps. For optimized conditions the limits of detection for the method ranged from 0.02 to 3.6 ng/g, intermediate precision ranged from 14 to 36% (as CV%), and the recovery from 8 up to 51%. The proposed methodology can be used in the rapid screening of soil for the presence of the selected pesticides, and was applied to landfill soil samples.