958 resultados para rotational viscometer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present simultaneous and continuous observations of the Halpha, Hbeta, He I D-3, Na I D-1,D-2 doublet and the Ca II H&K lines for the RS CVn system HR 1099. The spectroscopic observations were obtained during the MUSICOS 1998 campaign involving several observatories and instruments, both echelle and long-slit spectrographs. During this campaign, HR 1099 was observed almost continuously for more than 8 orbits of 2.(d)8. Two large optical flares were observed, both showing an increase in the emission of Halpha, Ca II H K, Hbeta and He I D-3 and a strong filling-in of the Na I D-1, D-2 doublet. Contemporary photometric observations were carried out with the robotic telescopes APT-80 of Catania and Phoenix-25 of Fairborn Observatories. Maps of the distribution of the spotted regions on the photosphere of the binary components were derived using the Maximum Entropy and Tikhonov photometric regularization criteria. Rotational modulation was observed in Halpha and He I D-3 in anti-correlation with the photometric light curves. Both flares occurred at the same binary phase (0.85), suggesting that these events took place in the same active region. Simultaneous X-ray observations, performed by ASM on board RXTE, show several flare-like events, some of which correlate well with the observed optical flares. Rotational modulation in the X-ray light curve has been detected with minimum flux when the less active G5 V star was in front. A possible periodicity in the X-ray flare-like events was also found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans.

Methods: The response of the detectors to field size, dose linearity, and dose rate were assessed for 6 MV FF beams and also 6 and 10 MV FFF beams. Dosimetric and mechanical accuracy of the detector array within the Octavius 4D rotational phantom was evaluated against measurements made using semiflex and pinpoint ionization chambers, and radiochromic film. Verification FF and FFF RapidArc plans were assessed using a gamma function with 3%/3 mm tolerances and 2%/2 mm tolerances and further analysis of these plans was undertaken using film and a second detector array with higher spatial resolution.

Results: A warm-up dose of >6 Gy was required for detector stability. Dose-rate measurements were stable across a range from 0.26 to 15 Gy/min and dose response was linear, although the device overestimated small doses compared with pinpoint ionization chamber measurements. Output factors agreed with ionization chamber measurements to within 0.6% for square fields of side between 3 and 25 cm and within 1.2% for 2 x 2 cm(2) fields. The Octavius 4D phantom was found to be consistent with measurements made with radiochromic film, where the gantry angle was found to be within 0.4. of that expected during rotational deliveries. RapidArc FF and FFF beams were found to have an accuracy of >97.9% and >90% of pixels passing 3%/3 mm and 2%/2 mm, respectively. Detector spatial resolution was observed to be a factor in determining the accurate delivery of each plan, particularly at steep dose gradients. This was confirmed using data from a second detector array with higher spatial resolution and with radiochromic film.

Conclusions: The Octavius 4D phantom with associated Octavius detector 729 ionization chamber array is a dosimetrically and mechanically stable device for pretreatment verification of FF and FFF RapidArc treatments. Further improvements may be possible through use of a detector array with higher spatial resolution (detector size and/or detector spacing). (C) 2013 American Association of Physicists in Medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Various grades of Thermoplastic Polyurethane (TPU) supplied by Bayer were studied to determine their suitability for the rotational moulding process. Following grinding, parts were produced using a variety of peak internal air temperatures and cooling rates. The tensile and impact properties of these parts were then analysed and it was found that both the grade and moulding conditions had a large bearing on the quality and mechanical strength of the part produced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rotational moulding promises designers attractive economics and a low-pressure process. The benefits of rotational moulding are compared here with other manufacturing methods such as injection and blow moulding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential of multiple layer fibre-reinforced mouldings is of growing interest to the rotational moulding industry because of their cost/performance ratio. The particular problem that arises when using reinforcements in this process relate to the fact that the process is low shear and good mixing of resin and reinforcement is not optimum under those conditions. There is also a problem of the larger/heavier reinforcing agents segregating out of the powder to lay up on the inner part surface. In this study, short glass fibres were incorporated and distributed into a polymer matrix to produce fibre-reinforced polymer composites using the rotational moulding process and characterised in terms of morphology and mechanical properties. © 2011 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the findings from internal mould cooling trials using a water spray configuration applied at various internal mould air temperatures from 120°C to 180°C for an aluminium mould. To achieve maximum benefit in terms of cycle time reduction, internal mould water cooling was used in conjunction with a combination of external forced air and water cooling. Savings in cooling times of up to 30% were achieved compared to conventional external only forced air cooling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The temperature at which densification ends for a range of blends comprising a metallocene catalysed medium density polyethylene (PE) in two different physical forms (powder and micropellets) were investigated using a novel data acquisition system (TP Picture®), developed by Total Petrochemicals [1]. The various blends were subsequently rotomoulded and test specimens prepared for mechanical analysis to establish the relationship between densification rate and bubble size / distribution on the part properties. The micropellets exhibited more rapid bubble removal times than powder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work has been to adapt and apply the advantages of rapid prototyping and electroforming technologies to try to achieve an innovative mould design for rotational moulding. The new innovative design integrates an electroformed shell, manufactured starting from a rapid prototyping mandrel, with different designed standard aluminium tools. The shell holder enables mould assembly with high precision manufacture of a shell in a few minutes. The overall mould cost is significantly decreased because it is only necessary to manufacture one or two shells each time; however, the rest of the elements of the mould are standard and usable for an infinite number of shells, depending on size.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Please consult the paper edition of this thesis to read. It is available on the 5th Floor of the Library at Call Number: Z 9999 C54 L434 1989

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Micromorphology is used to analyze a wide range of sediments. Many microstructures have, as yet, not been analyzed. Rotation structures are the least understood of microstructures: their origin and development forms the basis of this thesis. Direction of rotational movement helps understand formative deformational and depositional processes. Twenty-eight rotation structures were analyzed through two methods of data extraction: (a) angle of grain rotation measured from Nikon NIS software, and (b) visual analyses of grain orientation, neighbouring grainstacks, lineations, and obstructions. Data indicates antithetic rotation is promoted by lubrication, accounting for 79% of counter-clockwise rotation structures while 21 % had clockwise rotation. Rotation structures are formed due to velocity gradients in sediment. Subglacial sediments are sheared due to overlying ice mass stresses. The grains in the sediment are differentially deformed. Research suggests rotation structures are formed under ductile conditions under low shear, low water content, and grain numbers inducing grain-to-grain interaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High resolution optogalvanic spectrum of the (11, 7) band in the first positive system of nitrogen molecule has been recorded from 17179 to 17376 cm- 1. Assignment of 432 rotational lines belonging to the 27 branches of this band has been carried out.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Indium monofluoride was excited in a high-frequency discharge and the C-X system was photographed at a reciprocal dispersion of 0.3 AA mm-1 using a plane-grating spectrograph. Rotational analyses of the 0,0 1,0 2,2 3,3 4,4 2,4 3,5 4,6 and 5,7 bands have been carried out and the following molecular constants have been evaluated. Be'=0.2670(+or-3) cm-1, Be"=0.2628(+or-4) cm-1, alpha e'=0.0050(+or-4) cm-1, alpha e"=0.0020(+or-1) cm-1, De'=3.65(+or-5)*10-7 cm-1, De"=2.5(+or-3)*10-7 cm-1, beta e'=0.5(+or-2)*10-7 cm-1, beta e"=0.2(+or-1)*10-7 cm-1, re'=1.9672(+or-3) AA, re"=1.9853(+or-2) AA. The re" value agrees with the microwave absorption value 1.9854 AA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Ramsey-type interferometer is suggested, employing a cold trapped ion and two time-delayed offresonant femtosecond laser pulses. The laser light couples to the molecular polarization anisotropy, inducing rotational wavepacket dynamics. An interferogram is obtained from the delay dependent populations of the final field-free rotational states. Current experimental capabilities for cooling and preparation of the initial state are found to yield an interferogram visibility of more than 80%. The interferograms can be used to determine the polarizability anisotropy with an accuracy of about ±2%, respectively ±5%, provided the uncertainty in the initial populations and measurement errors are confined to within the same limits.