926 resultados para restraint and seclusion
Numerical and experimental studies of cold-formed steel floor systems under standard fire conditions
Resumo:
Light gauge cold-formed steel frame (LSF) structures are increasingly used in industrial, commercial and residential buildings because of their non-combustibility, dimensional stability, and ease of installation. A floor-ceiling system is an example of its applications. LSF floor-ceiling systems must be designed to serve as fire compartment boundaries and provide adequate fire resistance. Fire rated floor-ceiling assemblies formed with new materials and construction methodologies have been increasingly used in buildings. However, limited research has been undertaken in the past and hence a thorough understanding of their fire resistance behaviour is not available. Recently a new composite panel in which an external insulation layer is used between two plasterboards has been developed at QUT to provide a higher fire rating to LSF floors under standard fire conditions. But its increased fire rating could not be determined using the currently available design methods. Research on LSF floor systems under fire conditions is relatively recent and the behaviour of floor joists and other components in the systems is not fully understood. The present design methods thus require the use of expensive fire protection materials to protect them from excessive heat increase during a fire. This leads to uneconomical and conservative designs. Fire rating of these floor systems is provided simply by adding more plasterboard sheets to the steel joists and such an approach is totally inefficient. Hence a detailed fire research study was undertaken into the structural and thermal performance of LSF floor systems including those protected by the new composite panel system using full scale fire tests and extensive numerical studies. Experimental study included both the conventional and the new steel floor-ceiling systems under structural and fire loads using a gas furnace designed to deliver heat in accordance with the standard time- temperature curve in AS 1530.4 (SA, 2005). Fire tests included the behavioural and deflection characteristics of LSF floor joists until failure as well as related time-temperature measurements across the section and along the length of all the specimens. Full scale fire tests have shown that the structural and thermal performance of externally insulated LSF floor system was superior than traditional LSF floors with or without cavity insulation. Therefore this research recommends the use of the new composite panel system for cold-formed LSF floor-ceiling systems. The numerical analyses of LSF floor joists were undertaken using the finite element program ABAQUS based on the measured time-temperature profiles obtained from fire tests under both steady state and transient state conditions. Mechanical properties at elevated temperatures were considered based on the equations proposed by Dolamune Kankanamge and Mahendran (2011). Finite element models were calibrated using the full scale test results and used to further provide a detailed understanding of the structural fire behaviour of the LSF floor-ceiling systems. The models also confirmed the superior performance of the new composite panel system. The validated model was then used in a detailed parametric study. Fire tests and the numerical studies showed that plasterboards provided sufficient lateral restraint to LSF floor joists until their failure. Hence only the section moment capacity of LSF floor joists subjected to local buckling effects was considered in this research. To predict the section moment capacity at elevated temperatures, the effective section modulus of joists at ambient temperature is generally considered adequate. However, this research has shown that it leads to considerable over- estimation of the local buckling capacity of joist subject to non-uniform temperature distributions under fire conditions. Therefore new simplified fire design rules were proposed for LSF floor joist to determine the section moment capacity at elevated temperature based on AS/NZS 4600 (SA, 2005), NAS (AISI, 2007) and Eurocode 3 Part 1.3 (ECS, 2006). The accuracy of the proposed fire design rules was verified with finite element analysis results. A spread sheet based design tool was also developed based on these design rules to predict the failure load ratio versus time, moment capacity versus time and temperature for various LSF floor configurations. Idealised time-temperature profiles of LSF floor joists were developed based on fire test measurements. They were used in the detailed parametric study to fully understand the structural and fire behaviour of LSF floor panels. Simple design rules were also proposed to predict both critical average joist temperatures and failure times (fire rating) of LSF floor systems with various floor configurations and structural parameters under any given load ratio. Findings from this research have led to a comprehensive understanding of the structural and fire behaviour of LSF floor systems including those protected by the new composite panel, and simple design methods. These design rules were proposed within the guidelines of the Australian/New Zealand, American and European cold- formed steel structures standard codes of practice. These may also lead to further improvements to fire resistance through suitable modifications to the current composite panel system.
Resumo:
As part of an evaluation of the 2010 legislation for child vehicle occupants in Queensland, road-side observations of private passenger vehicles were used to estimate the proportions of children 0-under 7 years travelling in each of the 5 different restraint types (eg. forward facing child restraint). Data was collected in 4 major population centres: Brisbane, Sunshine Coast, Mackay and Townsville. Almost all children were restrained (95.1%, 95% CI 94.3-95.9%), with only 3.3% (95% CI 2.6-4.0%) clearly unrestrained and 44 (1.6%, 95% CI 1.1-2.1%) for whom restraint status could not be determined (‘unknown’). However, around 24.0% (95 CI 21.8-26.2%) of the target-aged children were deemed inappropriately restrained, primarily comprised of 3-6 year olds in seatbelts (18.7% of the 0-6 year olds, 95% CI 16.3-21.1%) or unrestrained (3.7% of the 0-6 year olds, 95% CI 2.5-4.9%) instead of booster seats. In addition, compliance appeared significantly lower for some regional locations where the proportion of children observed as completely unrestrained was relatively high and of concern
Resumo:
We establish an argument for fiscal restraints which is based on the idea that politicians are experts in the meaning of the credence good literature. A budget maximizing politician is better informed than the electorate about the necessary spending to ensure the states ability to provide services for the economy. Voters, being able to observe the budget but not the necessary level of spending, attenuate the government’s spending level via electoral control. A fiscal restraint limits the maximum spending a government will choose if the level of spending ensuring the politicians reelection is not sufficient to ensure the state’s ability to provide services to the economy. We determine when such a fiscal restraint improves voter welfare and discuss the role of the opposition in situations where very high levels of spending are required.
Resumo:
The Coping Orientation to Problems Experienced is a multidimensional scale designed to assess how people respond to stress. The COPE has been validated in a variety of populations displaying variations in factor structure. However, in terms of mental health populations, it has only been validated in alcohol-dependent samples. This paper investigated the factor structure of the COPE in a sample of adults diagnosed with depression and anxiety. Two hundred and seventy-one patients attending cognitive behaviour therapy for anxiety and depression completed the COPE. Confirmatory factor analysis found a poor fit for both lower order and higher order factors based upon the Lyne and Roger (2000) study. Exploratory factor analyses identified six primary subscales (Active Planning, Social Support, Denial, Acceptance, Disengagement, Restraint) which explained approximately 60% of the variance in coping. These 6 subscales may assist researchers and clinicians to validly measure coping in anxious and depressed adults.
Resumo:
Research shows that Indigenous Australians suspicion and fear of being ‘locked up’ may influence mental health service avoidance. Given this, the aim of this study was to explore, by qualitative analysis of in depth interviews (N = 3), how three Indigenous people experienced the controversial practice of seclusion Hans-Georg Gadamer’s phenomenology guided analysis of the material, and allowed narrated experiences to be understood within their cultural and historical context. Participants viewed seclusion negatively: police involvement in psychiatric care; perceptions of being punished and powerless; occasions of extreme use of force; and lack of care were prominent themes throughout the interviews. While power imbalances inherent in seclusion are problematic for all mental health clients, the distinguishing factor in the Indigenous clients’ experience is that seclusion is continuous with the discriminatory and degrading treatment by governments, police and health services that many Indigenous people have experienced since colonisation. The participants’ experiences echoed Goffman’s (1961) findings that institutional practices act to degrade and dehumanise clients whose resulting conformity eases the work of nursing staff. While some nurses perceive that seclusion reduces clients’ agitation (Meehan, Bergen & Fjeldsoe, 2004; Wynaden et al., 2001), one must ask at what cost to clients’ dignity, humanity and basic human rights.
Resumo:
Twelve patients receiving acute in-patient psychiatric care in Queensland, Australia, participated in semi-structured interviews to elicit their perceptions of seclusion. All respondents had experienced time in seclusion within the 7 days prior to interview. Interviews were audiotaped, transcribed and analysed using content analysis. Five major themes emerged: use of seclusion, emotional impact, sensory deprivation, maintaining control and staff-patient interaction. The prevailing negativity towards seclusion underscores the need for ongoing critical review of its use. In particular, the relationship between patient responses to seclusion and the circumstances in which seclusion takes place requires greater consideration. Interventions such as providing information to patients about seclusion, increased interaction with patients during seclusion, attention to privacy and effective debriefing following seclusion may help to reduce the emotional impact of the practice.
Resumo:
Design Semi-structured interviews. Setting 2 open, acute care units of a large tertiary mental health facility in Queensland, Australia. Patients 12 patients (58% men) who were 18–52 years of age and were secluded in the previous 7 days (mean duration 3.4 h). Methods Semi-structured, thematically organised interviews were audiotaped and transcribed. Transcripts were checked for errors against the audiotaped versions and were analysed using the process of meaning categorisation. Themes were identified and coded to produce categories. All members of the research team agreed on the final categorisations. These broad categories were further analysed, and themes were used to reflect patients' experiences of seclusion. Main findings 5 recurrent themes emerged. (1) Patients described the use of seclusion. Some patients thought that seclusion was used inappropriately and that the seclusion period was of more benefit to …
Resumo:
Material yielding is typically modeled either by plastic zone or plastic hinge methods under the context of geometric and material nonlinear finite element methods. In fire analysis of steel structures, the plastic zone method is widely used, but it requires extensively more computational efforts. The objective of this paper is to develop the nonlinear material model allowing for interaction of both axial force and bending moment, which relies on the plastic hinge method to achieve numerical efficiency and reduce computational effort. The biggest advantage of the plastic-hinge approach is its computational efficiency and easy verification by the design code formulae of the axial force–moment interaction yield criterion for beam–column members. Further, the method is reliable and robust when used in analysis of practical and large structures. In order to allow for the effect of catenary action, axial thermal expansion is considered in the axial restraint equations. The yield function for material yielding incorporated in the stiffness formulation, which allows for both axial force and bending moment effects, is more accurate and rational to predict the behaviour of the frames under fire. In the present fire analysis, the mechanical properties at elevated temperatures follow mainly the Eurocode 3 [Design of steel structures, Part 1.2: Structural fire design. European Committee for Standisation; 2003]. Example of a tension member at a steady state heating condition is modeled to verify the proposed spring formulation and to compare with results by others. The behaviour of a heated member in a highly redundant structure is also studied by the present approach.
Resumo:
This paper presents the response of pile foundations to ground shocks induced by surface explosion using fully coupled and non-linear dynamic computer simulation techniques together with different material models for the explosive, air, soil and pile. It uses the Arbitrary Lagrange Euler coupling formulation with proper state material parameters and equations. Blast wave propagation in soil, horizontal pile deformation and pile damage are presented to facilitate failure evaluation of piles. Effects of end restraint of pile head and the number and spacing of piles within a group on their blast response and potential failure are investigated. The techniques developed and applied in this paper and its findings provide valuable information on the blast response and failure evaluation of piles and will provide guidance in their future analysis and design.
Resumo:
Recent research at the Queensland University of Technology has investigated the structural and thermal behaviour of load bearing Light gauge Steel Frame (LSF) wall systems made of 1.15 mm G500 steel studs and varying plasterboard and insulation configurations (cavity and external insulation) using full scale fire tests. Suitable finite element models of LSF walls were then developed and validated by comparing with test results. In this study, the validated finite element models of LSF wall panels subject to standard fire conditions were used in a detailed parametric study to investigate the effects of important parameters such as steel grade and thickness, plasterboard screw spacing, plasterboard lateral restraint, insulation materials and load ratio on their performance under standard fire conditions. Suitable equations were proposed to predict the time–temperature profiles of LSF wall studs with eight different plasterboard-insulation configurations, and used in the finite element analyses. Finite element parametric studies produced extensive fire performance data for the LSF wall panels in the form of load ratio versus time and critical hot flange (failure) temperature curves for eight wall configurations. This data demonstrated the superior fire performance of externally insulated LSF wall panels made of different steel grades and thicknesses. It also led to the development of a set of equations to predict the important relationship between the load ratio and the critical hot flange temperature of LSF wall studs. Finally this paper proposes a simplified method to predict the fire resistance rating of LSF walls based on the two proposed set of equations for the load ratio–hot flange temperature and the time–temperature relationships.
Resumo:
Traffic crashes are the leading cause of death and injury among children aged between 4-14 years1,2 and premature graduation to adult seat belts2,3 and restraint misuse4 are common and known risk factors. Children are believed to prematurely graduate to adult belts and misuse the seat belt in booster seats if uncomfortable2,5,6. Although research has concentrated on educating parents and designing better restraints to reduce errors in use, comfort of the child in the restraint has not been studied. Currently there is no existing method for studying comfort in children in restraint systems, although self-report survey tools and pressure distribution mapping is commonly used to measure comfort among adult in vehicle seats. This poster presents preliminary results from work aimed at developing an appropriate method to measure comfort of children in vehicle restraint systems. The specific aims are to: 1. Examine the potential of using modified adult self-report/survey and pressure distribution mapping in children 2. Develop a video based, objective measure of comfort in children.
Resumo:
As news communication speeds up, investigative journalists have an increasing responsibility to minimise the risk of harm to vulnerable news sources. In addition, the increased longevity and instant global search-ability of news coverage and investigative journalism outputs such as documentaries, places upon journalists an increased responsibility for accuracy since online coverage cannot be easily corrected or retracted. This paper will examine how the risks to a news source and her family were considered and mitigated during the production of a radio documentary and newspaper story about an intended victim of child sacrifice. Pre-publication considerations included the possible risks to the mental health of the news source, the potential physical risk to her children and the risk to future family relationships. To hear the ABC Radio National documentary, A living sacrifice, on 360 Documentaries prior to the conference, see http://www.abc.net.au/radionational/programs/360/a-living-sacrifice/5359744. To read the Sunday Mail newspaper coverage of the story see http://www.couriermail.com.au/news/queensland/susannah-birch-talks-about-her-throat-being-slit-by-her-mother-when-she-was-a-baby/story-fnihsrf2-1226881911465.
Resumo:
The neural basis of Pavlovian fear conditioning is well understood and depends upon neural processes within the amygdala. Stress is known to play a role in the modulation of fear-related behavior, including Pavlovian fear conditioning. Chronic restraint stress has been shown to enhance fear conditioning to discrete and contextual stimuli; however, the time course and extent of restraint that is essential for this modulation of fear learning remains unclear. Thus, we tested the extent to which a single exposure to 1 hr of restraint would alter subsequent auditory fear conditioning in rats.
Resumo:
TThis article considers the radical, sweeping changes to Australian copyright law wrought by the Australia–United States Free Trade Agreement 2004 (AUSFTA). It contends that the agreement will result in a “piracy of the public domain”. Under this new regime, copyright owners will be able to obtain greater monopoly profits at the expense of Australian consumers, libraries and research institutions, as well as intermediaries, such as Internet service providers. Part One observes that the copyright term extension in Australia to life of the author plus 70 years for works will have a negative economic and cultural impact — with Australia’s net royalty payments estimated to be up to $88 million higher per year. Part Two argues that the adoption of stronger protection of technological protection measures modelled upon the Digital Millennium Copyright Act 1998 (U.S.) will override domestic policy–making processes, such as the Phillips Fox Digital Agenda Review, and judicial pronouncements such as the Stevens v Sony litigation. Part Three questions whether the new safe harbours protection for Internet service providers will adversely affect the sale of Telstra. This article concludes that there is a need for judicial restraint in interpreting the AUSFTA. There is an urgent call for the Federal Government to pass ameliorating reforms — such as an open–ended defence of fair use and a mechanism for orphan works. There is a need for caution in negotiating future bilateral trade agreements — lest the multinational system for the protection of copyright law be undermined.
Resumo:
In this paper we report the findings from an evaluation of the introduction of sensory modulation (SM) in an acute mental health inpatient unit. It was expected that SM could be used to help settle patients experiencing high levels of disturbance and that as a result, there would be less need for use of more restrictive seclusion practices. The evaluation took place in a hospital in south-east Queensland, Australia. SM was introduced in one acute unit while the other served as a control. The evaluation comprised two studies. In the first study we aimed to determine whether SM reduced the level of disturbance among patients given the opportunity to use it. In the second study we aimed to find out whether the introduction of SM reduced the frequency and duration of seclusion. In study 1, we found that most patients reported marked reduction in disturbance after using SM and there was a very large effect size for the group as a whole. In study 2, we found that frequency of seclusion dropped dramatically in the unit that introduced SM but rose slightly in the unit that did not have access to SM. The change in seclusion rate was highly significant (χ2 = 49.1, df = 1, p < 0.001). Results are discussed, having reference to the limitations inherent in a naturalistic study.