953 resultados para non-invasive monitoring


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Irrigation management in large crop fields is a very important practice. Since the farm management costs and the crop results are directly connected with the environmental moisture, water control optimization is a critical factor for agricultural practices, as well as for the planet sustainability. Usually, the crop humidity is measured through the water stress index (WSI), using imagery acquired from satellites or airplanes. Nevertheless, these tools have a significant cost, lack from availability, and dependability from the weather. Other alternative is to recover to ground tools, such as ground vehicles and even static base stations. However, they have an outstanding impact in the farming process, since they can damage the cultivation and require more human effort. As a possible solution to these issues, a rolling ground robot have been designed and developed, enabling non-invasive measurements within crop fields. This paper addresses the spherical robot system applied to intra-crop moisture measurements. Furthermore, some experiments were carried out in an early stage corn field in order to build a geo-referenced WSI map.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High temperatures and relative humidity can compromise animal welfare on the farm level, but less is known about those changes during long distance transport of domestic animals to slaughter. Although upper temperature limits have been established to transport pigs in Europe, few indices include relative or absolute humidity maxima or mention appropriate enthalpy ranges.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this thesis was to validate the use of infrared thermography (IRT) to non-invasively measure emotional reactions to different situations in pet dogs (Canis familiaris). A preliminary test, aimed to evaluate the correlation between eye-temperature and rectal temperature in dog, was performed. Then, in three different situations, negative (veterinary visit), positive (palatable food rewards), and mildly stressing followed by mildly positive (separation from and reunion with the owner), variations in heat emitted from lacrimal caruncle (referred to as eye temperature) were measured with an infrared thermographic camera. In addition, heart rate and heart rate variability parameters were collected using a non-invasive heart rate monitor designed for human use and validated on dogs. All experiments were video recorded to allow behavioral coding. During the negative situation dogs’ level of activity and stress related behaviors varied across compared to the baseline and dogs showed an increase in eye temperature despite having a significant decrease in the level of activity. The positive situation was characterized by a peak in eye temperature and mean HR and dogs engaged in behaviors indicating a positive arousal, focusing on food treats and tail wagging but there were not variations in HRV during stimulation but only an increment in SDNN immediately after the stimulus. In the separation from and reunion with the owner dogs’ eye temperature and mean HR did not vary neither in the stressful nor in the positive situations, RMSSD increased after the positive episode, SDNN dropped during the two stimulations and it increased after the stimulations. During the separation from the owner dogs were mainly directed to the door or to the experimenter while during the reunion with the owner dogs were focused mainly on the owner and on the environment, exhibiting safe base effect. A different approach was used to assess the welfare of shelter dogs. Dogs were implanted with a telemeter and after implantation dogs were housed in sequence in four different situations lasting 1 week: alone, alone with toys and a stretch cot for sleeping, with an unknown, spayed, female, and alone with a daily 2-hours interaction with an experimenter. Two different approaches were tried: partially random extracted fragments from every week, behaviors from 8 a.m. to 4 p.m. were continuous during baseline and the female situation. Results showed different reactions by dogs to the different situations and interestingly not all enrichments were enjoyed by the dogs improving their welfare. Overall results suggest that IRT may represent a useful tool to investigate emotional reactions in dogs. Nevertheless, further research is needed to establish the specificity and sensivity of IRT in this context and to assess how different dogs’ characteristics, breed, previous experience and the valence and arousal elicited by the stimulus could influence the magnitude and type of the response. The role of HRV in understanding emotional valence and the one of telemeters in understanding long-term effects on sheltered dogs’ welfare is also discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Concurrent analysis of antibiotic resistance of colonising and invasive Streptococcus pneumoniae gives a more accurate picture than looking at either of them separately. Therefore, we analysed 2,129 non-invasive and 10,996 invasive pneumococcal isolates from Switzerland from 2004 to 2014, which spans the time before and after the introduction of the heptavalent (PCV7) and 13-valent (PCV13) conjugated pneumococcal polysaccharide vaccines. Serotype/serogroup information was linked with all antibiotic resistance profiles. During the study period, the proportion of non-susceptible non-invasive and invasive isolates significantly decreased for penicillin, ceftriaxone, erythromycin and trimethoprim/sulfamethoxazole (TMP-SMX). This was most apparent in non-invasive isolates from study subjects younger than five years (penicillin (p = 0.006), erythromycin (p = 0.01) and TMP-SMX (p = 0.002)). Resistant serotypes/serogroups included in PCV7 and/or PCV13 decreased and were replaced by non-PCV13 serotypes (6C and 15B/C). Serotype/serogroup-specific antibiotic resistance rates were comparable between invasive and non-invasive isolates. Adjusted odds ratios of serotype/serogroup-specific penicillin resistance were significantly higher in the west of Switzerland for serotype 6B (1.8; 95% confidence interval (CI): 1.4-4.8), 9V (3.4; 95% CI: 2.0-5.7), 14 (5.3; 95% CI: 3.8-7.5), 19A (2.2; 95% CI: 1.6-3.1) and 19F (3.1; 95% CI: 2.1-4.6), probably due to variations in the antibiotic consumption.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-05

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose a model for non-ideal monitoring of the state of a coupled quantum dot qubit by a quantum tunnelling device. The non-ideality is modelled using an equivalent measurement circuit. This allows realistically available measurement results to be related to the state of the quantum system (qubit). We present a quantum trajectory that describes the stochastic evolution of the qubit state conditioned by tunnelling events (i.e. current) through the device. We calculate and compare the noise power spectra of the current in an ideal and a non-ideal measurement. The results show that when the two qubit dots are strongly coupled the non-ideal measurement cannot detect the qubit state precisely. The limitation of the ideal model for describing a realistic system maybe estimated from the noise spectra.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of solutions that prevent dehydration or promote adequate re-hydration play a vital role in preventing fatigue during exercise, however, the methods commonly used to assess the hydration ability of such solutions are invasive and often assess the components of absorption separately. This paper describes using a non-invasive deuterium tracer technique that assesses gastric emptying and intestinal absorption simultaneously to evaluate the uptake of water during rest and exercise. The kinetics of absorption are further examined by mathematical modelling of the data generated. For the rest group, 0.05 g/kg of body weight of deuterium, contained in gelatine capsules, was ingested with ordinary tap water and saliva samples were collected every 5 min for one hour while the subject remained seated. The deuterium was administered as above for the exercise group but sample collection was during one hour of exercise on a treadmill at 55% of the subject's maximum heart rate. The enrichment data for each subject were mathematically modelled and the parameters obtained were compared across groups using an independent samples t-test. Compared with the rest condition, the exercise group showed delayed absorption of water as indicated by significant differences for the modelling parameters t(2), t(1/2), maximum absorption rate and solution absorption amount at t(1). Labelling with a deuterium tracer is a good measure of the relative rate ingested fluids are absorbed by the body. Mathematical modelling of the data generates rates of maximum absorption and allows calculation of the percentage of the solution that is absorbed at any given time during the testing period. Copyright (C) 2004 John Wiley Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pulse Transit Time (PTT) measurement has showed potential in non-invasive monitoring of changes in blood pressure. In children, the common peripheral sites used for these studies are a finger or toe. Presently, there are no known studies conducted to investigate any possible physiologic parameters affecting PTT measurement at these sites for children. In this study, PTT values of both peripheral sites were recorded from 64 children in their sitting posture. Their mean age with standard deviation (SD) was 8.2 2.6years (ranged 3 to 12years). Subjects' peripheries path length, heart rate (HR), systolic (SBP) and diastolic blood pressure (DBP) were measured to investigate any contributions to PTT measurement. The peripheral pulse timing characteristic measured by photoplethysmography (PPG) shows a 59.5 8.5ms (or 24.8 0.4%) difference between the two peripheries (p