1000 resultados para manual medicine
Resumo:
The purpose of the present article was to present the series operated by a Liver Transplant Group of the interior of the State of Sao Paulo, Brazil. Sixty patients were transplanted from May 2001 to May 2007. Thirty percent of the patients had alcoholic cirrhosis. 18.3% had C virus-induced cirrhosis, 10% had C virus- and alcohol-induced cirrhosis, 6% had B virus-induced cirrhosis, 13.3% had cryptogenic cirrhosis, 8.3% autoimmune cirrhosis, 13.3% had familial amyloidotic polyneuropathy (FAP), and 13.3% had hepatocellular carcinomas. The series was divided by a chronological criterion into two periods: A (n = 42) and B (n = 18) with the latter group operated based upon the Model for End-stage Liver Disease (MELD) criterion. Sixty-nine percent were men. Age ranged from 14 to 66 years. Period A included 12% Child A: 59.2%, Child B; 24%, Child C; and 4.8%, FAR Period B comprises 22.2% Child A: 11.1%, Child B: 33.3%, Child C: and 33.3%, FAP. MELD scores ranged from 8 to 35 for period A and from 14 to 31 for period B. Intraoperative mortality was 2/42 patients for period A and 0/18 for period B, overall postoperative mortality was 40% including for period A, 35% among Child B and C patients, and 5 % among FAP and Child A patients (P <.05) and 16.6% for period B among 11. 1 % Child B patients and 5.5 % FAP patients; 3.3 % of patients required retransplantation due to hepatic artery thrombosis. Real postoperative survival was 60% during period A and 83.3% during period B, with an overall survival rate of 67% for the two periods. The present results show levels of postoperative mortality, (especially during period B), and survival rates similar to those reported by several other centers in Brazil.
Resumo:
Background: We report the validation of a method for the determination of acetaldehyde, acetone, methanol, and ethanol in biological fluids using manual headspace sample introduction and an acetonitrile internal standard. Method: This method uses a capillary column (I = 30 m, I.D. = 0.25 mm, dF = 0.25 mu m) installed in a gas chromatography-flame ionization detector (GC-FID) apparatus with a run time of 7.5 minutes. Results: Analysis of the retention times and the resolution of the analyte peaks demonstrated excellent separation without widening of the peaks. Precision and accuracy were good (interassay precision < 15% and recovery between 85% and 115%) in both blood and urine. Conclusion: The method was linear (r > 0.09) over the analytical measurement range (AMR) of each analyte.
Resumo:
Ictal behavior coupled with SPECT findings during 28 seizures in patients with temporal lobe epilepsy (TLE) with unilateral hippocampal sclerosis (13 left; 15 right) was displayed as flowcharts from right-sided (RTLE) plus left-sided (LTLE) seizures. Ictal SPECT was classified blind to neuroethology. Behaviors were categorized as ipsilateral to the epileptogenic zone (IL), contralateral to the epileptogenic zone (CL), or bilateral. SPECT intensity and region were categorized as IL or CL to the epileptogenic zone. All patients developed automatisms and had hyperperfusion in their temporal lobes. Patients` verbal responses to questions had statistical interactions in RTLE but not in LTLE sum. Most CL dystonic posturing was correlated to IL basal ganglia hyperperfusion. Basal ganglia activation occurred in seizures without dystonic posturing and CL manual automatisms, and lack of IL dystonic posturing and the presence of CL cerebellar hemispheric hyperperfusion were also observed. Coupling of neuroethology and SPECT findings reliably evaluates ictal behavior and functionality of associated brain areas. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
The aim of this study was to compare the crown-rump length (CRL) and the fetal head and trunk (HT) volume between singletons and twins conceived after in vitro fertilization. Thirty pregnant patients submitted to embryo transfer were enrolled in this research. Ten conceived twins (20 dichorionic fetuses) while other 20 conceived singletons. The gestational age was calculated by adding 14 d to the number of days between the oocyte retrieval and the scheduled ultrasound. Three-dimensional ultrasound scans were performed weekly from 73 d (10 wk and 3 d) to 101 d (14 wk and 3 d) of gestational age. HT volume was assessed by VOCAL using 15 degrees step rotation on the manual mode. The measurement of CRL was performed by using the longitudinal plane of the fetus in the multiplanar view. The CRL and HT volume weekly relative increase were evaluated to compare the growth between singletons and twins. No significant difference was identified, in any analyzed week, when comparing the mean of CRL and HT volume between singletons and twins. Additionally, no significant difference between singletons and twins was noticed when comparing the weekly relative increase, both for CRL and HT volume. However, the weekly relative increase was significantly higher for HT volume than for CRL in every week studied for both singletons and twins. The total relative increase observed between 73 and 101 d was much higher for HT volume than for CRL: 679 +/- 39% versus 138 +/- 18% in singletons and 689 +/- 58% versus 139 +/- 21% in twins (HT volume and CRL, respectively), suggesting that HT volume could more accurately determine the gestational age.
Resumo:
The aim of this study was to compare the intra-and inter-rater reliability of pressure pain threshold (PPT) and manual palpation (MP) of orofacial structures in symptomatic and symptom-free children for temporomandibular disorders (TMD). Fourteen children reporting pain in masticatory muscles or the temporomandibular joint and 16 symptom-free children were randomly assessed on three different occasions: by rater-1 in the first and third session and by rater-2 in the second session. The trained raters applied algometry and MP as recommended by the Research Diagnostic Criteria for TMD. Intraclass correlation coefficients and the Kappa statistic were used to assess the levels of reliability of PPT and MP, respectively. Excellent intra-and inter-rater reliability levels were observed for PPT values at most of the examined sites for symptom-free children and excellent and moderate reliability levels for children reporting pain. For MP, moderate and poor intra-rater and inter-rater reliability levels were observed for most sites in both groups. Algometry showed higher reliability levels for both groups of children and is recommended for pain assessment in children in association with MP. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Objective: To evaluate the validity and applicability of the Mini International Neuropsychiatric Interview (MINI) used by family medicine residents in primary health care (PHC) in Brazil. Methods: Training for administrating the MINI was given as part of a broad psychiatry education program. Interviews were held with 120 PHC patients who were at least 15 years old. MINI was administered by 25 resident physicians, while the Structured Clinical Interview for Diagnosis (SCID) was administered by a psychiatrist blind to patients` results on the MINI, and the diagnoses on both interviews were compared. The resident physicians answered questions on the applicability of the MINI. Results: Concordance levels for any mental disorder, the broader current diagnostic categories and the most common specific diagnoses were analyzed. Kappa coefficients ranged between 0.65 and 0.85; sensitivity, between 0.75 and 0.92; specificity, between 0.90 and 0.99; positive predictive values (PPV), between 0.60 and 0.86; negative predictive values (NPV), between 0.92 and 0.99; and accuracy, between 0.88 and 0.98. The resident physicians considered MINI comprehensibility and clinical relevance satisfactory. Conclusions: These good psychometric results in a real-world setting may be related to a special training program, which is more frequent, intensive and diversified. In these conditions, the MINI is a useful tool for general practitioners. (c) 2008 Elsevier Inc. All rights reserved.
Resumo:
The platelet blood count in laboratorial routine provides to the clinician important information about the hemostasis of the patient. There are many techniques described, however the gold standard techniques realized in hemocytometer spent a lot of time, making this technique impracticable in great routines. This research had the intent to evaluate if the automatic veterinary blood counter QBC Vet Autoread (R), whose results get five minutes to be ready, is capable to offer a trustworthy platelet count number. To this end, were evaluated the correlations among three different forms of platelets count in dogs: count in automatic blood counter QBC Vet Autoread (R), estimative in blood smear and the gold standard method by manual count in hemocytometer. The viability and confidence use of automatic blood counters of the medicine veterinary routine. Seventeen dogs were chosen randomly way, in the medical and surgical routine of HOVET-USP. The analysis revel high correlation between the hemocytometer and the estimative in blood smear (r=0,875) and between the hemocytometer and automatic blood count by QBC Vet Autoread (R) (r=0,939). Conclude that the platelet blood cont by QBC Vet Autoread (R), in addition to be fast, it`s more truthful when compared with estimative in blood smear, although the latter one also had elevated correlation. However, morphological analysis through the smears cannot be dismissed because none of the other two techniques evaluated have the ability to assess platelet morphological changes.