918 resultados para lagging indicator


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new photocatalyst indicator ink based on methylene blue (MB) is described that allows the presence and activity of a thin (15 nm) photocatalytic film to be assessed in seconds. The ink is very stable (shelf life > 6 months) and the color change (blue to colorless) striking. The ink utilizes a sacrificial electron donor, glycerol, to trap the photogenerated holes, leaving the photogenerated electrons to react with MB to produce its. reduced, leuco, form (LMB). The efficacy of the MB ink is due to the presence of acid in its formulation, which curtails significantly. the otherwise usual, rapid reoxidation of LMB by ambient O-2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanocrystalline SnO2, ncSnO(2), is used as a photosensitiser in a colourimetric O-2 indicator that comprises a sacrificial electron donor, glycerol, a redox dye, methylene blue (MB), and an encapsulating polymer, hydroxyethyl cellulose (HEC). Upon exposure to a burst of UVB light the indicator is activated (photo-bleached) as the MB is photoreduced by the ncSnO(2) particles. In the absence of oxygen, the film stays bleached, but recovers its original colour upon exposure to oxygen. Unlike its TiO2-based predecessor, the HEC/glycerol/MB/ncSnO(2) O-2 indicator is not activated by UVA light from white fluorescent lamps, but is by UVB light. This feature provides much greater control in the activation of the indicator. Other work shows the rate of activation depends upon I-0.75, where I is the UVB irradiance, indicating a partial dependence upon the electron-hole recombination process. The half-life of the recovery of the original colour of a UV-activated film, t(50), is directly proportional to the ambient level of oxygen. The advantages of using this indicator in modified atmosphere packaging as a possible quality assurance indicator are discussed briefly. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A hydrogen peroxide vapour indicator is described comprising a triarylmethane dye, lissamine green (LG), dissolved in a polymer, polyvinyl alcohol (PVA). The indicator is green/blue in the absence of hydrogen peroxide vapour but is rapidly bleached in the presence of hydrogen peroxide vapour. The kinetics of LG bleaching appear approximately first order with respect [LG] and the concentration of H2O2, which, in turn, is proportional to the partial pressure of H2O2. However, the kinetics also appear to depend directly upon the reciprocal of the film thickness, implying some dependence upon the diffusion of the H2O2 vapour through the indicator film. Like most other H2O2 indicator films (such as starch-iodide paper), the LG/PVA indicator is not particularly selective and responds to most other volatile strong oxidising agents, such as ozone and chlorine. However, it is rapid in response (

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An oxygen indicator is described, comprising nanoparticles of titania dispersed in hydroxyethyl cellulose (HEC) polymer film containing a sacrificial electron donor, glycerol, and the redox indicator, indigo-tetrasulfonate (ITS). The indicator is blue-coloured in the absence of UV light, however upon exposure to UV light it not only loses its colour but also luminesces, unless and until it is exposed to oxygen, whereupon its original colour is restored. The initial photobleaching spectral ( absorbance and luminescence) response characteristics in air and in vacuum are described and discussed in terms of a simple reaction scheme involving UV activation of the titania photocatalyst particles, which are used to reduce the redox dye, ITS, to its leuco form, whilst simultaneously oxidising the glycerol to glyceraldehye. The response characteristics of the activated, that is, UV photobleached, form of the indicator to oxygen are also reported and the possible uses of such an indicator to measure ambient O-2 levels are discussed. Copyright (C) 2008 Andrew Mills et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article reports the behaviour of three photocatalyst indicator inks, based on the redox dyes: methylene blue (NIB), resorufin (Rf) and 2,6-dichloroindophenol (DCIP), and assess their performance in comparison to the pioneering resazurin (Rz)-based ink for the rapid assessment of the activity of very thin, photocatalyst films, such as Activ (TM) self-cleaning glass. From a commercial 'demonstrator of photocatalysis' perspective, all three redox dyes appear more attractive compared to Rz since all generate colourless products in the ink formulation when photoreduced on Activ (TM) under anaerobic conditions, whereas, the reduced product from Rz, the redox dye resorufin, Rf. is pink in colour. However, the ink based on Rf is far too slow to effect the rapid measurement of photocatalytic activity even in the absence of oxygen, and in the presence of oxygen the latter inhibits the overall kinetics of photoreduction by re-oxidising the reduced product, dihydroresorufin, HRf, back to Rf. Similarly, despite the attractive rapid rate of photobleaching for NIB under anaerobic conditions, compared to the other redox dyes, the reduced product of the MB-based ink. leuco-MB, is so oxygen-sensitive that the ink cannot be photoreduced under aerobic conditions, thus rendering the ink unsuitable for use in the field. The DCIP-based ink is slightly less easy to photoreduce under both anaerobic and ambient atmospheric conditions compared to the Rz-based ink. However. in addition to its more attractive colour change, the DCIP-based ink is unaffected by the ambient level of oxygen present (%O-2) and the relative humidity (%RH), whereas, for the Rz-based ink, both parameters effect the photoreduction kinetics. By incorporating the DCIP ink into a felt-tipped pen, the ink is suitable for use in the laboratory and field to perform not only a qualitative test, but also to allow a semi-quantitative analysis of photocatalytic activity by eye. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A UV indicator/dosimeter based on benzyl viologen (BV2+) encapsulated in polyvinyl alcohol (PVA) is described. Upon exposure to UV light, the BV2+/PVA film turns a striking purple colour due to the formation of the cation radical, BV center dot+. The usual oxygen sensitivity of BV center dot+ is significantly reduced due to the very low oxygen permeability of the encapsulating polymer, PVA. Exposure of a typical BV2+/PVA film, for a set amount of time, to UVB light with different UV indices produces different levels of BV center dot+, as measured by the absorbance of the film at 550 nm. A plot of the change in absorbance at this wavelength, Delta Abs(550), as a function of UV index, UVI, produces a linear calibration curve which allows the film to be used as a UVB indicator, and a similar procedure could be employed to allow it to be used as a solar UVI indicator. A typical BV2+/PVA film generates a significant, semi-permanent (stable for > 24 h) saturated purple colour (absorbance similar to 0.8-0.9) upon exposure to sunlight equivalent to a minimal erythemal dose associated with Caucasian skin, i.e. skin type II. The current drawbacks of the film and the possible future use of the BV2+/PVA film as a personal solar UV dosimeter for all skin types are briefly discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel UV indicator is described, comprising nanocrystalline particles of titania dispersed in a film of a polymer, hydroxyl ethyl cellulose (HEC), containing: a mild reducing agent, triethanolamine (TEOA) and a redox indicator, methylene blue (MB). The UV indicator film is blue-coloured in the absence of UV light and loses colour upon exposure to UV light, attaining within a few min a steady-state degree of bleaching that can provide a measure of the irradiance of the incident light. The original blue colour of the film returns once the source of UV light is removed. The spectral characteristics of a typical UV indicator film, and its components, are discussed and the UV-absorbing action of the titania particles highlighted. From the measured %bleaching undergone by a typical UV indicator as a function of light irradiance the indicator appears fully bleached, within 7 min, by a UV irradiance of 3 mW cm (-) or greater. The mechanism by which the UV indicator works is described. The reversible nature of the UV indicator is removed by covering a typical UV indicator with a thin, largely oxygen impermeable, polymer film, such as the regenerated cellulose found in Sellotape(TM). The product is a UV dosimeter, the response of which is related to the intensity and duration of the incident UV light, as well as the amount of titania in the film. A typical UV dosimeter film is fully bleached by 250 mJ cm(-2) of UV light. The possible use of these novel indicators to measure UV exposure levels, irradiance and dose, is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The results of a detailed characterization study of a novel UV-activated colorimetric oxygen indicator are described. The indicator uses nanoparticles of titania to photosensitize the reduction of methylene blue by triethanolamine in a polymer encapsulation medium, using UVA light. Upon UV irradiation, the indicator bleaches and remains in this colorless state in the dark, unless and until it is exposed to oxygen, whereupon its original color is restored. The indicator is reusable and irreversible. The rate of color recovery is proportional to the level of oxygen present. A layer of PET (poly(ethylene terephthalate)), of thickness b, placed on top of the indicator film slows down its response, and the 90% recovery time is proportional to b.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We detail the calculations of North Sea Large Fish Indicator values for 2009-2011, demonstrating an apparent stall in recovery. Therefore, recovery to the Marine Strategy Framework Directive's good environmental status of 0.3 by the 2020 deadline now looks less certain and may take longer than was expected using data from 2006 to 2008.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An algorithm has been developed for a Public Access Defibrillator which utilizes distinctive features from the impedance cardiogram (ICG) recorded via defibrillator pads to advise both lay users and minimally trained bystanders to ensure CPR effectiveness. Following ethical approval, data were collected and marked. CPR was administered by trained personnel. 211 cases were gathered and the training set included 106 cases. A retrospective analysis was carried out of simultaneously recorded ECG and ICG. The speed of compressions was calculated by counting the outstanding waves in the ICG during CPR. Also if the base-to-peak amplitude of the ICG is greater than a minimum threshold, the corresponding compressions were classified as being applied with adequate force. For the validation set, adequate speed was detected with 91.45% sensitivity and 96.27% specificity (79826s) and adequate force with 99.94% sensitivity and 97.91% specificity (91973s). © 2011 CCAL.