910 resultados para intra-modal and inter-modal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Signal processing techniques for mitigating intra-channel and inter-channel fiber nonlinearities are reviewed. More detailed descriptions of three specific examples highlight the diversity of the electronic and optical approaches that have been investigated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La circulation extracorporelle (CEC) est une technique utilisée en chirurgie cardiaque effectuée des milliers de fois chaque jour à travers le monde. L’instabilité hémodynamique associée au sevrage de la CEC difficile constitue la principale cause de mortalité en chirurgie cardiaque et l’hypertension pulmonaire (HP) a été identifiée comme un des facteurs de risque les plus importants. Récemment, une hypothèse a été émise suggérant que l'administration prophylactique (avant la CEC) de la milrinone par inhalation puisse avoir un effet préventif et faciliter le sevrage de la CEC chez les patients atteints d’HP. Toutefois, cette indication et voie d'administration pour la milrinone n'ont pas encore été approuvées par les organismes réglementaires. Jusqu'à présent, la recherche clinique sur la milrinone inhalée s’est principalement concentrée sur l’efficacité hémodynamique et l'innocuité chez les patients cardiaques, bien qu’aucun biomarqueur n’ait encore été établi. La dose la plus appropriée pour l’administration par nébulisation n'a pas été déterminée, de même que la caractérisation des profils pharmacocinétiques (PK) et pharmacodynamiques (PD) suite à l'inhalation. L'objectif de notre recherche consistait à caractériser la relation exposition-réponse de la milrinone inhalée administrée chez les patients subissant une chirurgie cardiaque sous CEC. Une méthode analytique par chromatographie liquide à haute performance couplée à un détecteur ultraviolet (HPLC-UV) a été optimisée et validée pour le dosage de la milrinone plasmatique suite à l’inhalation et s’est avérée sensible et précise. La limite de quantification (LLOQ) était de 1.25 ng/ml avec des valeurs de précision intra- et inter-dosage moyennes (CV%) <8%. Des patients souffrant d’HP pour lesquels une chirurgie cardiaque sous CEC était prévue ont d’abord été recrutés pour une étude pilote (n=12) et, par la suite, pour une étude à plus grande échelle (n=28) où la milrinone (5 mg) était administrée par inhalation pré-CEC. Dans l'étude pilote, nous avons comparé l'exposition systémique de la milrinone peu après son administration avec un nébuliseur pneumatique ou un nébuliseur à tamis vibrant. L’efficacité des nébuliseurs en termes de dose émise et dose inhalée a également été déterminée in vitro. Dans l'étude à plus grande échelle conduite en utilisant exclusivement le nébuliseur à tamis vibrant, la dose inhalée in vivo a été estimée et le profil pharmacocinétique de la milrinone inhalée a été pleinement caractérisé aux niveaux plasmatique et urinaire. Le ratio de la pression artérielle moyenne sur la pression artérielle pulmonaire moyenne (PAm/PAPm) a été choisi comme biomarqueur PD. La relation exposition-réponse de la milrinone a été caractérisée pendant la période d'inhalation en étudiant la relation entre l'aire sous la courbe de l’effet (ASCE) et l’aire sous la courbe des concentrations plasmatiques (ASC) de chacun des patients. Enfin, le ratio PAm/PAPm a été exploré comme un prédicteur potentiel de sortie de CEC difficile dans un modèle de régression logistique. Les expériences in vitro ont démontré que les doses émises étaient similaires pour les nébuliseurs pneumatique (64%) et à tamis vibrant (68%). Cependant, la dose inhalée était 2-3 fois supérieure (46% vs 17%) avec le nébuliseur à tamis vibrant, et ce, en accord avec les concentrations plasmatiques. Chez les patients, en raison des variations au niveau des facteurs liés au circuit et au ventilateur causant une plus grande dose expirée, la dose inhalée a été estimée inférieure (30%) et cela a été confirmé après récupération de la dose de milrinone dans l'urine 24 h (26%). Les concentrations plasmatiques maximales (Cmax: 41-189 ng/ml) et l'ampleur de la réponse maximale ΔRmax-R0 (0-65%) ont été observées à la fin de l'inhalation (10-30 min). Les données obtenues suite aux analyses PK sont en accord avec les données publiées pour la milrinone intraveineuse. Après la période d'inhalation, les ASCE individuelles étaient directement reliées aux ASC (P=0.045). Enfin, notre biomarqueur PD ainsi que la durée de CEC ont été identifiés comme des prédicteurs significatifs de la sortie de CEC difficile. La comparaison des ASC et ASCE correspondantes a fourni des données préliminaires supportant une preuve de concept pour l'utilisation du ratio PAm/PAPm comme biomarqueur PD prometteur et justifie de futures études PK/PD. Nous avons pu démontrer que la variation du ratio PAm/PAPm en réponse à la milrinone inhalée contribue à la prévention de la sortie de CEC difficile.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La circulation extracorporelle (CEC) est une technique utilisée en chirurgie cardiaque effectuée des milliers de fois chaque jour à travers le monde. L’instabilité hémodynamique associée au sevrage de la CEC difficile constitue la principale cause de mortalité en chirurgie cardiaque et l’hypertension pulmonaire (HP) a été identifiée comme un des facteurs de risque les plus importants. Récemment, une hypothèse a été émise suggérant que l'administration prophylactique (avant la CEC) de la milrinone par inhalation puisse avoir un effet préventif et faciliter le sevrage de la CEC chez les patients atteints d’HP. Toutefois, cette indication et voie d'administration pour la milrinone n'ont pas encore été approuvées par les organismes réglementaires. Jusqu'à présent, la recherche clinique sur la milrinone inhalée s’est principalement concentrée sur l’efficacité hémodynamique et l'innocuité chez les patients cardiaques, bien qu’aucun biomarqueur n’ait encore été établi. La dose la plus appropriée pour l’administration par nébulisation n'a pas été déterminée, de même que la caractérisation des profils pharmacocinétiques (PK) et pharmacodynamiques (PD) suite à l'inhalation. L'objectif de notre recherche consistait à caractériser la relation exposition-réponse de la milrinone inhalée administrée chez les patients subissant une chirurgie cardiaque sous CEC. Une méthode analytique par chromatographie liquide à haute performance couplée à un détecteur ultraviolet (HPLC-UV) a été optimisée et validée pour le dosage de la milrinone plasmatique suite à l’inhalation et s’est avérée sensible et précise. La limite de quantification (LLOQ) était de 1.25 ng/ml avec des valeurs de précision intra- et inter-dosage moyennes (CV%) <8%. Des patients souffrant d’HP pour lesquels une chirurgie cardiaque sous CEC était prévue ont d’abord été recrutés pour une étude pilote (n=12) et, par la suite, pour une étude à plus grande échelle (n=28) où la milrinone (5 mg) était administrée par inhalation pré-CEC. Dans l'étude pilote, nous avons comparé l'exposition systémique de la milrinone peu après son administration avec un nébuliseur pneumatique ou un nébuliseur à tamis vibrant. L’efficacité des nébuliseurs en termes de dose émise et dose inhalée a également été déterminée in vitro. Dans l'étude à plus grande échelle conduite en utilisant exclusivement le nébuliseur à tamis vibrant, la dose inhalée in vivo a été estimée et le profil pharmacocinétique de la milrinone inhalée a été pleinement caractérisé aux niveaux plasmatique et urinaire. Le ratio de la pression artérielle moyenne sur la pression artérielle pulmonaire moyenne (PAm/PAPm) a été choisi comme biomarqueur PD. La relation exposition-réponse de la milrinone a été caractérisée pendant la période d'inhalation en étudiant la relation entre l'aire sous la courbe de l’effet (ASCE) et l’aire sous la courbe des concentrations plasmatiques (ASC) de chacun des patients. Enfin, le ratio PAm/PAPm a été exploré comme un prédicteur potentiel de sortie de CEC difficile dans un modèle de régression logistique. Les expériences in vitro ont démontré que les doses émises étaient similaires pour les nébuliseurs pneumatique (64%) et à tamis vibrant (68%). Cependant, la dose inhalée était 2-3 fois supérieure (46% vs 17%) avec le nébuliseur à tamis vibrant, et ce, en accord avec les concentrations plasmatiques. Chez les patients, en raison des variations au niveau des facteurs liés au circuit et au ventilateur causant une plus grande dose expirée, la dose inhalée a été estimée inférieure (30%) et cela a été confirmé après récupération de la dose de milrinone dans l'urine 24 h (26%). Les concentrations plasmatiques maximales (Cmax: 41-189 ng/ml) et l'ampleur de la réponse maximale ΔRmax-R0 (0-65%) ont été observées à la fin de l'inhalation (10-30 min). Les données obtenues suite aux analyses PK sont en accord avec les données publiées pour la milrinone intraveineuse. Après la période d'inhalation, les ASCE individuelles étaient directement reliées aux ASC (P=0.045). Enfin, notre biomarqueur PD ainsi que la durée de CEC ont été identifiés comme des prédicteurs significatifs de la sortie de CEC difficile. La comparaison des ASC et ASCE correspondantes a fourni des données préliminaires supportant une preuve de concept pour l'utilisation du ratio PAm/PAPm comme biomarqueur PD prometteur et justifie de futures études PK/PD. Nous avons pu démontrer que la variation du ratio PAm/PAPm en réponse à la milrinone inhalée contribue à la prévention de la sortie de CEC difficile.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Overrecentdecades,remotesensinghasemergedasaneffectivetoolforimprov- ing agriculture productivity. In particular, many works have dealt with the problem of identifying characteristics or phenomena of crops and orchards on different scales using remote sensed images. Since the natural processes are scale dependent and most of them are hierarchically structured, the determination of optimal study scales is mandatory in understanding these processes and their interactions. The concept of multi-scale/multi- resolution inherent to OBIA methodologies allows the scale problem to be dealt with. But for that multi-scale and hierarchical segmentation algorithms are required. The question that remains unsolved is to determine the suitable scale segmentation that allows different objects and phenomena to be characterized in a single image. In this work, an adaptation of the Simple Linear Iterative Clustering (SLIC) algorithm to perform a multi-scale hierarchi- cal segmentation of satellite images is proposed. The selection of the optimal multi-scale segmentation for different regions of the image is carried out by evaluating the intra- variability and inter-heterogeneity of the regions obtained on each scale with respect to the parent-regions defined by the coarsest scale. To achieve this goal, an objective function, that combines weighted variance and the global Moran index, has been used. Two different kinds of experiment have been carried out, generating the number of regions on each scale through linear and dyadic approaches. This methodology has allowed, on the one hand, the detection of objects on different scales and, on the other hand, to represent them all in a sin- gle image. Altogether, the procedure provides the user with a better comprehension of the land cover, the objects on it and the phenomena occurring.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de Mestrado apresentada ao Instituto Superior de Psicologia Aplicada para obtenção de grau de Mestre na especialidade de Psicologia Clínica.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we investigate the impact of inter-modal four-wave mixing on mode- and wavelength-division-multiplexing systems. A set of coupled nonlinear Schrödinger equations, including linear mode coupling, is derived allowing to isolate the inter-modal four-wave mixing terms. The efficiency of inter-modal four-wave mixing between degenerate LP modes is found to be significantly higher than the intra-modal four-wave mixing efficiency. However, it is shown that the inter-modal four-wave mixing efficiency between degenerate modes is significantly reduced by the linear mode coupling.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A field experiment was conducted for two consecutive years to study the effect of fertilizer application methods and inter and intra-row weed-crop competition durations on density and biomass of different weeds and growth, grain yield and yield components of maize. The experimental treatments comprised of two fertilizer application methods (side placement and below seed placement) and inter and intra-row weed-crop competition durations each for 15, 30, 45, and 60 days after emergence, as well as through the crop growing period. Fertilizer application method didn't affect weed density, biomass, and grain yield of maize. Below seed fertilizer placement generally resulted in less mean weed dry weight and more crop leaf area index, growth rate, grain weight per cob and 1000 grain weight. Minimum number of weeds and dry weight were recorded in inter-row or intra-row weed-crop competition for 15 DAE. Number of cobs per plant, grain weight per cob, 1000 grain weight and grain yield decreased with an increase in both inter-row and intra-row weed-crop competition durations. Maximum mean grain yield of 6.35 and 6.33 tha-1 were recorded in inter-row and intra-row weed competition for 15 DAE, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In mixed stands, inter-specific competition can be lower than intra-specific competition when niche complementarity and/or facilitation between species prevail. These positive interactions can take place at belowground and/or aboveground levels. Belowground competition tends to be size symmetric while the aboveground competition is usually for light and almost always size-asymmetric. Interactions between forest tree species can be explored analyzing growth at tree level by comparing intra and inter-specific competition. At the same time, possible causes of niche complementarity can be inferred relating intra and inter-specific competition with the mode of competition, i.e. size-symmetric or sizeasymmetric. The aim of this paper is to further our understanding of the interactions between species and to detect possible causes of competition reduction in mixed stands of beech (Fagus sylvatica L.) with other species: pine?beech, oak?beech and fir?beech. To test whether species growth is better explained by size-symmetric and/or size-asymmetric competition, five different competition structures where included in basal area growth models fitted using data from the Spanish National Forest Inventory for the Pyrenees. These models considered either size-symmetry only (Reineke?s stand density index, SDI), size-asymmetry only (SDI of large trees or SDI of small trees), or both combined. In order to assess the influence of the admixture, these indices were introduced in two different ways, one of which was to consider that trees of all species compete in a similar way, and the other was to split the stand density indices into intra- and inter-specific competition components. The results showed that in pine?beech mixtures, there is a slightly negative effect of beech on pine basal area growth while beech benefitted from the admixture of Scots pine; this positive effect being greater as the proportion of pine trees in larger size classes increases. In oak?beech mixtures, beech growth was also positively influenced by the presence of oaks that were larger than the beech trees. The growth of oak, however, decreased when the proportion of beech in SDI increased, although the presence of beech in larger size classes promoted oak growth. Finally, in fir?beech mixtures, neither fir nor beech basal area growth were influenced by the presence of the other species. The results indicate that size-asymmetric is stronger than size-symmetric competition in these mixtures, highlighting the importance of light in competition. Positive species interactions in size-asymmetric competition involved a reduction of asymmetry in tree size-growth relationships.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les champignons mycorhiziens à arbuscules (CMA), classés dans le phylum Glomeromycota, ne peuvent pas être facilement identifiés par la morphologie de leurs spores et leurs mycélia à l'intérieur ou à l'extérieur des racines de leurs hôtes. Ce problème fondamental d'identification rend l'étude de leur diversité, en particulier dans leur habitat naturel (sol et racine) extrêmement difficile. Les gènes ribosomaux ont été largement utilisés pour développer des amorces spécifiques et en inférer des arbres phylogénétiques. Cependant, ces gènes sont très polymorphes et existent en plusieurs copies dans le génome des CMA, ce qui complique l’interprétation des résultats. Dans notre étude, nous avons étudié le polymorphisme intra- et inter-spécifique du gène β-tubuline, présent en faible nombre de copies dans le génome des CMA, afin d’obtenir de nouvelles séquences nucléotidiques pour développer des marqueurs moléculaires. Les gènes β-tubuline amplifiés à partir de l'ADN génomique de cinq espèces du genre Glomus ont été clonés et séquencés. L’analyse des séquences indique un polymorphisme intraspécifique chez trois espèces de CMA. Deux séquences paralogues très variables ont été nouvellement identifiées chez les G. aggregatum, G. fasciculatum et G. cerebriforme. Aucun polymorphisme n’a été détecté chez les G. clarum et G. etunicatum. Toutes les séquences montrent la présence de deux introns hautement variables. La majorité des substitutions ont été localisées dans les exons et sont synonymes à 90%. La conservation des acides aminés suggère un niveau élevé de sélection négative sur le gène β-tubuline et nous permet de confirmer que les CMA représentent un ancien groupe fongique (400 million d’années). L’analyse phylogénétique, réalisée avec vingt et une séquences nucléotidiques du gène β-tubuline, a révélé que les séquences des Glomaceae forment un groupe monophylétique bien supporté, avec les Acaulosporaceae et Gigasporaceae comme groupe frère. Les séquences paralogues nouvellement identifiées chez les G. aggregatum et G. fasciculatum n'ont pas été monophylétiques au sein de chaque espèce. Les oligonucléotides ont été choisis sur la base des régions variables et conservées du gène β-tubuline. Le test PCR des amorces β-Tub.cerb.F/ β-Tub.cerb.R a révélé des bandes spécifiques de 401 pb pour les séquences paralogues du G. cerebriforme. Deux paires d’amorces ont été développées afin d’identifier les séquences du groupe nommé Tub.1. Les tests PCR nous ont permis d’identifier certaines séquences du groupe Tub.1. Une paire d’amorce β-Tub.2.F/ β-Tub.2.R nous a permis d’identifier certaines séquences paralogues du groupe nommé Tub.2. L’analyse d’autres gènes combinée à celle du gène β-tubuline permettra le développement de marqueurs moléculaires plus spécifiques pour l’identification de CMA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Brain activity can be measured non-invasively with functional imaging techniques. Each pixel in such an image represents a neural mass of about 105 to 107 neurons. Mean field models (MFMs) approximate their activity by averaging out neural variability while retaining salient underlying features, like neurotransmitter kinetics. However, MFMs incorporating the regional variability, realistic geometry and connectivity of cortex have so far appeared intractable. This lack of biological realism has led to a focus on gross temporal features of the EEG. We address these impediments and showcase a "proof of principle" forward prediction of co-registered EEG/fMRI for a full-size human cortex in a realistic head model with anatomical connectivity, see figure 1. MFMs usually assume homogeneous neural masses, isotropic long-range connectivity and simplistic signal expression to allow rapid computation with partial differential equations. But these approximations are insufficient in particular for the high spatial resolution obtained with fMRI, since different cortical areas vary in their architectonic and dynamical properties, have complex connectivity, and can contribute non-trivially to the measured signal. Our code instead supports the local variation of model parameters and freely chosen connectivity for many thousand triangulation nodes spanning a cortical surface extracted from structural MRI. This allows the introduction of realistic anatomical and physiological parameters for cortical areas and their connectivity, including both intra- and inter-area connections. Proper cortical folding and conduction through a realistic head model is then added to obtain accurate signal expression for a comparison to experimental data. To showcase the synergy of these computational developments, we predict simultaneously EEG and fMRI BOLD responses by adding an established model for neurovascular coupling and convolving "Balloon-Windkessel" hemodynamics. We also incorporate regional connectivity extracted from the CoCoMac database [1]. Importantly, these extensions can be easily adapted according to future insights and data. Furthermore, while our own simulation is based on one specific MFM [2], the computational framework is general and can be applied to models favored by the user. Finally, we provide a brief outlook on improving the integration of multi-modal imaging data through iterative fits of a single underlying MFM in this realistic simulation framework.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gonocerus acuteangulatus (Hemiptera: Coreidae) è considerato uno dei principali fitofagi del nocciolo, in grado di causare con l’attività trofica pesanti perdite quali-quantitative di produzione. Nel triennio sono state quindi condotte indagini sulla bioetologia di G. acuteangulatus volte a: I) studiare comportamento alimentare ed effetti sulla produzione corilicola, II) identificare i feromoni e valutarne l’attività mediante biosaggi fisiologici e comportamentali in laboratorio, semi-campo e campo, III) rilevare le piante ospiti alternative al nocciolo. Mediante isolamento di adulti del coreide su rami di nocciolo con frutti è stata confermata l’assenza di correlazione fra entità del danno e numerosità degli individui presenti in corileto. Dalle analisi sensoriali su nocciole sane e danneggiate è emerso che le alterazioni causate delle punture di nutrizione sono rese più evidenti da conservazione e tostatura. Variazioni di tempi e temperature di tostatura potrebbero mitigare gli effetti del cimiciato. Nello studio dei feromoni, G. acuteangulatus, molto mobile nell’ambiente, è risultato poco adatto ai biosaggi in condizioni artificiali, come quelle in olfattometro e semi-campo. Le femmine sono tuttavia apparse attrattive per adulti di entrambi i sessi, mentre la miscela feromonale sintetizzata ha mostrato un’azione attrattiva, seppure non costante. Pertanto, ulteriori ripetizioni sono necessarie per convalidare questi risultati preliminari, modificando le condizioni di saggio in relazione alle caratteristiche della specie. Infine è stata accertata la preferenza del fitofago per alcune specie vegetali rispetto al nocciolo. Nel corso del triennio, popolazioni molto consistenti di G. acuteangulatus sono state rilevate su bosso, ciliegio di Santa Lucia, rosa selvatica, sanguinello, spino cervino, in corrispondenza del periodo di comparsa e maturazione dei frutti. Nell’impostazione di una strategia di difesa a basso impatto ambientale, l’attrattività di queste piante, in sinergia con eventuali feromoni di aggregazione, potrebbe essere utilmente sfruttata, per mantenere il coreide lontano dalla coltura.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have limited knowledge on the potential pattern similarities/differences of trust’s role that may exist in information use obtained through intra- and extra-organizational relationships. This study addresses this question by investigating how trust leads to information use. Data from 338 intra-organizational and a sub-ample of 158 interorganizational dyadic information exchange-relationships showed that trust is an important driver of the utilization of market information in both cases. Trust has no direct relationship to information use, instead has a strong indirect effect through a mediator, perceived quality of information. The effects of trust on the use of information obtained through inter- and extra-organizational dyadic relationships proved to be similar.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and low cost method to determine volatile contaminants in post-consumer recycled PET flakes was developed and validated by Headspace Dynamic Concentration and Gas Chromatography-Flame Ionization Detection (HDC-GC-FID). The analytical parameters evaluated by using surrogates include: correlation coefficient, detection limit, quantification limit, accuracy, intra-assay precision, and inter-assay precision. In order to compare the efficiency of the proposed method to recognized automated techniques, post-consumer PET packaging samples collected in Brazil were used. GC-MS was used to confirm the identity of the substances identified in the PET packaging. Some of the identified contaminants were estimated in the post-consumer material at concentrations higher than 220 ng.g-1. The findings in this work corroborate data available in the scientific literature pointing out the suitability of the proposed analytical method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and fast capillary zone electrophoresis (CZE) method has been developed and validated for quantification of a non-nucleoside reverse transcriptase inhibitor (NNRTI) nevirapine, in pharmaceuticals. The analysis was optimized using 10 mmol L-1 sodium phosphate buffer pH 2.5, +25 kV applied voltage, hydrodynamic injection 0.5 psi for 5 s and direct UV detection at 200 µm. Diazepam (50.0 µg mL-1) was used as internal standard. Under these conditions, nevirapine was analyzed in approximately less than 2.5 min. The analytical curve presented a coefficient of correlation of 0.9994. Limits of detection and quantification were 1.4 µg mL-1 and 4.3 µg mL-1, respectively. Intra- and inter-day precision expressed as relative standard deviations were 1.4% and 1.3%, respectively and the mean recovery was 100.81%. The active pharmaceutical ingredient was subjected to hydrolysis (acid, basic and neutral) and oxidative stress conditions. No interference of degradation products and tablet excipients were observed. This method showed to be rapid, simple, precise, accurate and economical for determination of nevirapine in pharmaceuticals and it is suitable for routine quality control analysis since CE offers benefits in terms of quicker method development and significantly reduced operating costs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to determine the reproducibility, reliability and validity of measurements in digital models compared to plaster models. Fifteen pairs of plaster models were obtained from orthodontic patients with permanent dentition before treatment. These were digitized to be evaluated with the program Cécile3 v2.554.2 beta. Two examiners measured three times the mesiodistal width of all the teeth present, intercanine, interpremolar and intermolar distances, overjet and overbite. The plaster models were measured using a digital vernier. The t-Student test for paired samples and interclass correlation coefficient (ICC) were used for statistical analysis. The ICC of the digital models were 0.84 ± 0.15 (intra-examiner) and 0.80 ± 0.19 (inter-examiner). The average mean difference of the digital models was 0.23 ± 0.14 and 0.24 ± 0.11 for each examiner, respectively. When the two types of measurements were compared, the values obtained from the digital models were lower than those obtained from the plaster models (p < 0.05), although the differences were considered clinically insignificant (differences < 0.1 mm). The Cécile digital models are a clinically acceptable alternative for use in Orthodontics.