999 resultados para implant impression accuracy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To examine the effects of gaze position and optical blur, similar to that used in multifocal corrections, on stepping accuracy for a precision stepping task among older adults. Methods: Nineteen healthy older adults (mean age, 71.6 +/- 8.8 years) with normal vision performed a series of precision stepping tasks onto a fixed target. The stepping tasks were performed using a repeated-measures design for three gaze positions (fixating on the stepping target as well as 30 and 60 cm farther forward of the stepping target) and two visual conditions (best-corrected vision and with +2.50DS blur). Participants' gaze position was tracked using a head-mounted eye tracker. Absolute, anteroposterior, and mediolateral foot placement errors and within-subject foot placement variability were calculated from the locations of foot and floor-mounted retroreflective markers captured by flash photography of the final foot position. Results: Participants made significantly larger absolute and anteroposterior foot placement errors and exhibited greater foot placement variability when their gaze was directed farther forward of the stepping target. Blur led to significantly increased absolute and anteroposterior foot placement errors and increased foot placement variability. Furthermore, blur differentially increased the absolute and anteroposterior foot placement errors and variability when gaze was directed 60 cm farther forward of the stepping target. Conclusions: Increasing gaze position farther ahead from stepping locations and the presence of blur negatively impact the stepping accuracy of older adults. These findings indicate that blur, similar to that used in multifocal corrections, has the potential to increase the risk of trips and falls among older populations when negotiating challenging environments where precision stepping is required, particularly as gaze is directed farther ahead from stepping locations when walking.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Normal physiological processes can alter the weight of an infant by ± 80 g a day. Variations in measured weight and in measured changes in weight cannot be reduced by better scales or better techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiation therapy (RT) plays currently significant role in curative treatments of several cancers. External beam RT is carried out mostly by using megavoltage beams of linear accelerators. Tumor eradication and normal tissue complications correlate to dose absorbed in tissues. Normally this dependence is steep and it is crucial that actual dose within patient accurately correspond to the planned dose. All factors in a RT procedure contain uncertainties requiring strict quality assurance. From hospital physicist´s point of a view, technical quality control (QC), dose calculations and methods for verification of correct treatment location are the most important subjects. Most important factor in technical QC is the verification that radiation production of an accelerator, called output, is within narrow acceptable limits. The output measurements are carried out according to a locally chosen dosimetric QC program defining measurement time interval and action levels. Dose calculation algorithms need to be configured for the accelerators by using measured beam data. The uncertainty of such data sets limits for best achievable calculation accuracy. All these dosimetric measurements require good experience, are workful, take up resources needed for treatments and are prone to several random and systematic sources of errors. Appropriate verification of treatment location is more important in intensity modulated radiation therapy (IMRT) than in conventional RT. This is due to steep dose gradients produced within or close to healthy tissues locating only a few millimetres from the targeted volume. The thesis was concentrated in investigation of the quality of dosimetric measurements, the efficacy of dosimetric QC programs, the verification of measured beam data and the effect of positional errors on the dose received by the major salivary glands in head and neck IMRT. A method was developed for the estimation of the effect of the use of different dosimetric QC programs on the overall uncertainty of dose. Data were provided to facilitate the choice of a sufficient QC program. The method takes into account local output stability and reproducibility of the dosimetric QC measurements. A method based on the model fitting of the results of the QC measurements was proposed for the estimation of both of these factors. The reduction of random measurement errors and optimization of QC procedure were also investigated. A method and suggestions were presented for these purposes. The accuracy of beam data was evaluated in Finnish RT centres. Sufficient accuracy level was estimated for the beam data. A method based on the use of reference beam data was developed for the QC of beam data. Dosimetric and geometric accuracy requirements were evaluated for head and neck IMRT when function of the major salivary glands is intended to be spared. These criteria are based on the dose response obtained for the glands. Random measurement errors could be reduced enabling lowering of action levels and prolongation of measurement time interval from 1 month to even 6 months simultaneously maintaining dose accuracy. The combined effect of the proposed methods, suggestions and criteria was found to facilitate the avoidance of maximal dose errors of up to even about 8 %. In addition, their use may make the strictest recommended overall dose accuracy level of 3 % (1SD) achievable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The creep behaviour of a creep-resistant AE42 magnesium alloy has been examined in the temperature range of 150 to 240 degrees C at the stress levels ranging from 40 to 120 MPa using impression creep technique. A normal creep behaviour, i.e., strain rate decreasing with strain and then reaching a steady state, is observed at all the temperatures and stresses employed The stress exponent varies from 5.1 to 5.7 and the apparent activation energy varies from 130 to 140 kJ/mol, which suggests the high temperature climb of dislocation controlled by lattice self-diffusion being the dominant creep mechanism in the stress and temperature range employed The creep behaviour of the AE42 alloy has also been compared with its composites reinforced with Saffil short fibres and SiC particles in four combinations. All the composites exhibited a lower creep rate than the monolithic AE42 alloy tested at the same temperature and stress levels and the decrease in creep rate was greater in the longitudinal direction than in the transverse direction, as expected. All the hybrid composites, i.e., the composites reinforced with a combination of Saffil short fibres and SiC particles, exhibited creep rates comparable to the composite reinforced with 20% Saffil short fibres alone at all the temperature and stress levels employed, which is beneficial from the commercial point of view.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study contributes to the neglect effect literature by looking at the relative trading volume in terms of value. The results for the Swedish market show a significant positive relationship between the accuracy of estimation and the relative trading volume. Market capitalisation and analyst coverage have in prior studies been used as proxies for neglect. These measures however, do not take into account the effort analysts put in when estimating corporate pre-tax profits. I also find evidence that the industry of the firm influence the accuracy of estimation. In addition, supporting earlier findings, loss making firms are associated with larger forecasting errors. Further, I find that the average forecast error increased in the year 2000 – in Sweden.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Five different shaped weirs were designed and pertinent data for their use are given. One of these weir shapes had the least “sharp edge” at the junction of the base weir and “complementary weir.” Two other types of weirs had equal slopes at the junction of the base weir and complementary weir. Another shape, for which neither the indication accuracy was constant nor the slope was equal at the junction of the base weir and complementary weir, was also tested. The results of the four weir shapes hydraulically tested give consistent values for the coefficient of discharge varying between 0.625 to 0.631. The indication accuracies of all the previously designed linear proportional weirs (includig Sutro weir) are neither constant nor unity, as is believed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The formation of anomalous indentations, with two opposite faces describing a pin-cushion effect and the other two faces normal, in long elongated grains of an extruded Mg-2Al-1Zn alloy is reported. Subsurface microstructural observations combined with Schmid factor calculations suggest that extension twinning accompanied by basal slip are the reasons for these. Johnson's expanding cavity model is invoked for further substantiation. (C) 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many previous studies regarding the estimation of mechanical properties of single walled carbon nanotubes (SWCNTs) report that, the modulus of SWCNTs is chirality, length and diameter dependent. Here, this dependence is quantitatively described in terms of high accuracy curve fit equations. These equations allow us to estimate the modulus of long SWCNTs (lengths of about 100-120 nm) if the value at the prescribed low lengths (lengths of about 5-10 nm) is known. This is supposed to save huge computational time and expense. Also, based on the observed length dependent behavior of SWCNT initial modulus, we predict that, SWCNT mechanical properties such as Young's modulus, secant modulus, maximum tensile strength, failure strength, maximum tensile strain and failure strain might also exhibit the length dependent behavior along with chirality and length dependence. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is concerned with the modifications of the Extended Bellmouth Weir (EBM weir) earlier designed by Keshava Murthy. It is shown that by providing inclined sides (equivalent to providing an inward-trapezoidal weir) over a sector of a circle of radius R, separated by a distance 2t, and depth d, the measurable range of EBM can be considerably enhanced (over 375%). Simultaneously, the other parameters of the weir are optimized such that the reference plane of the weir coincides with its crest making it a constant-accuracy linear weir. Discharge through the aforementioned weir is proportional to the depths of flow measured above the crest of the weir for all heads in the range of 0.5R less-than-or-equal-to h less-than-or-equal-to 7.9R, within a maximum deviation of +/-1% from the theoretical discharge. Experiments with two typical weirs show excellent agreement with the theory by giving a constant-average coefficient of discharge of 0.619