996 resultados para implant dentistry


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The bone resorption in the anterior maxilla, due to its aesthetic importance, can be considered one of the challenges in implant dentistry. Autogenous bone graft is the most indicated bone augmentation procedure, aiming an implant supported rehabilitation.. Alternatively, some other graft procedures can be done with homogenous and xenogenous bone graft, biomaterials and different associations. Additionally to the mentioned biomaterials, the bone morphogenetic protein (BMP), specially the rhBMP-2, which was characterized as a bone osteoinductor, and consecutively, a potential autogenous graft substitute, with previsibility and no necessity of association to other biomaterial. The objective of this study is to present a single case using the rhBMP-2 for bone augmentation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: The aim of this systematic review was to evaluate clinical and safety data for recombinant human bone morpho-genetic protein-2 (rhBMP-2) in an absorbable collagen sponge (ACS) carrier when used for alveolar ridge/maxillary sinusaugmentation in humans.Materials and Methods: Clinical studies/case ser ies published 1980 through June 2012 using rhBMP-2/ACS were searched.Studies meeting the following criteria were considered eligible for inclusion: >10 subjects at baseline and maxillary sinus oralveolar ridge augmentation not concomitant with implant placement.Results: Seven of 69 publications were eligible for review. rhBMP-2/ACS yielded clinically meaningful bone formationfor maxillary sinus augmentation that would allow placement of regular dental implants without consistent differencesbetween rhBMP-2 concentrations. Never theless, the statistical analysis showed that sinus augmentation following autog-enous bone graft was significantly greater (mean bone height: 1.6 mm, 95% CI: 0.5–2.7 mm) than for rhBMP-2/ACS(rhBMP-2 at 1.5 mg/mL). In extraction sockets, rhBMP-2/ACS maintained alveolar ridge height while enhancing alve olarridge width. Safety reports did not represent concerns for the proposed indications.Conclusions: rhBMP-2/ACS appears a promising alternative to autogenous bone grafts for alveolar ridge/maxillary sinusaugmentation; dose and carrier optimization may expand its efficacy, use, and clinical application.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ameloblastoma is a true neoplasm of odontogenic epithelial origin. This pathology can be classified into 4 groups: unicystic, solid or multicystic, peripheral, and malignant. Solid ameloblastomas of the mandible are the most common of them, and represent a challenging group of tumours to treat; in addition the follicular histopathological subtype has a high likelihood of recurrence. Thus, the challenges in the management of this tumour are to provide complete excision in addition to reconstruct the bony defect, in order to provide the patient with reasonable cosmetic and functional outcome. With this in mind, this paper aimed to describe the management of a solid multilocular ameloblastoma of follicular subtype in a 39-year-old female. Case report The authors report a case of a solid multilocular ameloblastoma of follicular subtype in a 39-year-old female who was successfully treated by partial resection of the mandible with immediate reconstruction using an iliac crest, as a donor site. After 15 months, the patient was rehabilitated using titanium implant dentistry, and has been followed up for 5 years without signs or symptoms of recurrence. Conclusion Correct surgical planning is the key for successful management of solid ameloblastoma with multilocular features, which is best treated using radical resection with immediate reconstruction, which ensures complete tumour excision, prevents recurrence, and enables fast and safe dental rehabilitation. Biomedical prototypes should be used since they provide acceptable precision and are useful for surgical planning.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The contemporary implant dentistry is in constant technological development, improving the oral rehabilitation process of partial or totally edentulous patients. On the other hand, anatomical limitations, such as the maxillary sinus and the mandibular canal in the posterior region of the jaws can limit the implant placement. Furthermore, due to the absence of dental elements, alveolar ridge atrophy is frequently observed. This aspect represents a loss either in quantity or quality of the bone tissue available for the dental implant rehabilitation. To make possible the dental implant rehabilitation even in adverse conditions, some solutions have been considered, such as the use of short implants (≤ 10 mm length) and/or small diameter implants (2,8; 3,3 and 3,5 mm width). The aim of this study is to present a literature review considering the use of short implants in oral rehabilitation, presenting the currently view of the matter. Based on the literature review, the use of short implants produced similar clinical success to conventional implants (greater than 10 mm in length). Therefore, its use can be considered a viable alternative, where anatomical limitations are present.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

ObjectiveTo study the buccal dimensional tissue changes at oral implants following free gingival grafting, with or without including the keratin layer, performed at the time of implant installation into alveolar mucosa.Material and methodsThe mandibular premolars and first molars were extracted bilaterally in six Beagle dogs. In the right side of the mandible (Test), flaps were first elevated, and the buccal as well as part of the lingual masticatory mucosa was removed. An incision of the periosteum at the buccal aspect was performed to allow the flap to be coronally repositioned. Primary wound closure was obtained. In the left side, the masticatory (keratinized) mucosa was left in situ, and no sutures were applied (Control). After 3months of healing, absence of keratinized mucosa was confirmed at the test sites. Two recipient sites were prepared at each side of the mandible in the region of the third and fourth premolars. All implants were installed with the shoulder placed flush with the buccal alveolar bony crest, and abutments were connected to allow a non-submerged healing. Two free gingival mucosal grafts were harvested from the buccal region of the maxillary canines. One graft was left intact (gingival mucosal graft), while for the second, the epithelial layer was removed (gingival connective tissue graft). Subsequently, the grafts were fixed around the test implants in position of the third and fourth premolars, respectively. After 3months, the animals were euthanized and ground sections obtained.ResultsSimilar bony crest resorption and coronal extension of osseointegration were found at test and control sites. Moreover, similar dimensions of the peri-implant soft tissues were obtained at test and control sites.ConclusionsThe increase in the alveolar mucosal thickness by means of a gingival graft affected the peri-implant marginal bone resorption and soft tissue recession around implants. This resulted in outcomes that were similar to those at implants surrounded by masticatory mucosa, indicating that gingival grafting in the absence of keratinized mucosa around implants may reduce the resorption of the marginal crest and soft tissue recession.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim To evaluate the influence of yellow bone marrow on osseointegration of titanium oral implants using a long bone model.Material and methodsThe two tibiae of eight sheep were used as experimental sites. Two osteotomies for implant installation were prepared in each tibia. At the control sites, no further treatments were performed while, at the test sites, bone marrow was removed from the osteotomy site with a curette to an extent that exceeded the implant dimensions. As a result, the apical portion of the implants at the control sites was in contact with bone marrow while, at the test sites, it was in contact with the blood clot. After 2months, the same procedures were performed in the contralateral side. After another month, the animal was sacrificed. Ground sections were obtained for histological analysis.ResultsAfter 1month of healing, no differences between test and control sites were found in the apical extension of osseointegration and the percentage of new bone-to-implant contact. However, after 3months of healing, a higher percentage of new bone-to-implant contact was found at the test compared to the control sites in the marrow compartment. The apical extension of osseointegration, however, was similar to that found at the 1-month healing period both for test and control sites.ConclusionsOsseointegration appeared to be favored by the presence of a blood clot when compared to the presence of yellow fatty bone marrow. Moreover, the contact with cortical bone appeared to be a prerequisite for the osseointegration process in the long bone model.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

ObjectiveTo study bone healing at implants installed with different insertion torques.Material and methodsIn six Labrador dogs, all mandibular premolars and first molars were extracted. After 4months of healing, flaps were elevated, and two implant sites were prepared at each side of the mandible. In the right side of the mandible, the distal sites were prepared conventionally, while the mesial sites were over-prepared by 0.2mm. As a consequence, a final insertion torque of similar to 30Ncm at the distal and a minimal insertion torque close to 0Ncm at the mesial sites were obtained. In the left sides of the mandible, however, the recipient sites were underprepared by 0.3mm resulting in an insertion torque of 70Ncm at both implants. Cover screws were applied, and flaps sutured to fully submerge the experimental sites. After 4months, the animals were sacrificed and ground sections obtained for histological evaluation.ResultsThe mineralized bone-to-implant contact was in the range of 55.2-62.1%, displaying the highest value at implants with similar to 30Ncm insertion torque and the lowest value at the implant sites with close to 0Ncm insertion torque. No statistically significant differences were revealed. Bone density was in the range of 43.4-54.9%, yielding the highest value at implants with 70Ncm insertion torque and the lowest at the implant sites with close to 0Ncm insertion torque. The difference between the sites of similar to 30Ncm and the corresponding 70Ncm insertion torque reached statistical significance.ConclusionsSimilar amounts of osseointegration were obtained irrespective of the insertion torque applied. Moreover, implants installed in sites with close to 0Ncm insertion torque may properly osseointegrate as well.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AimTo describe the sequential healing after elevation of the maxillary sinus mucosa applying the lateral access technique with the use of autogenous bone grafting without membrane to occlude the osteotomy access.Material and methodsImmediately after the elevation of the maxillary sinus Schneiderian membrane, applying the lateral access technique in 10 minipigs, autologous bone was harvested from the lateral aspect of the mandibular molar region and ground into particles with a bone mill. The space under the Schneiderian membrane was filled with this graft. No membranes were placed onto the access osteotomy. The healing was evaluated after 15, 30, 90 and 180days. Paraffin sections were prepared and analyzed histologically.ResultsAfter 15days of healing, the elevated area was mainly filled with provisional matrix, newly formed bone and some remnants of bone chips, and appeared reduced in volume compared with that at the time of surgery. After 30days of healing, further shrinkage of the height of the elevated space was found, with similar percentages of the different tissue components. After 90 and 180days, the area underneath the Schneiderian membrane appeared reduced in volume and condensed toward the base of the sinus. The bone tissues appeared to be more mature, both for the mineralized and the non-mineralized portions, while connective tissue occupied 20% of the space, most likely related to the lack of the use of a membrane occluding the access at the time of surgery.ConclusionsSuboptimal healing outcomes with respect to augmentation of the space under the sinus floor membrane were documented when autologous bone chips were used as a filler and no membrane was applied to cover the access.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To compare peri-implant soft- and hard-tissue integration at implants installed juxta- or sub-crestally. Furthermore, differences in the hard and soft peri-implant tissue dimensions at sites prepared with drills or sonic instruments were to be evaluated. Three months after tooth extraction in six dogs, recipient sites were prepared in both sides of the mandible using conventional drills or a sonic device (Sonosurgery(®) ). Two implants with a 1.7-mm high-polished neck were installed, one with the rough/smooth surface interface placed at the level of the buccal bony crest (control) and the second placed 1.3 mm deeper (test). After 8 weeks of non-submerged healing, biopsies were harvested and ground sections prepared for histological evaluation. The buccal distances between the abutment/fixture junction (AF) and the most coronal level of osseointegration (B) were 1.6 ± 0.6 and 2.4 ± 0.4 mm; between AF and the top of the bony crest (C), they were 1.4 ± 0.4 and 2.2 ± 0.2 mm at the test and control sites, respectively. The top of the peri-implant mucosa (PM) was located more coronally at the test (1.2 ± 0.6 mm) compared to the control sites (0.6 ± 0.5 mm). However, when the original position of the bony crest was taken into account, a higher bone loss and a more apical position of the peri-implant mucosa resulted at the test sites. The placement of implants into a sub-crestal location resulted in a higher vertical buccal bone resorption and a more apical position of the peri-implant mucosa in relation to the level of the bony crest at implant installation. Moreover, peri-implant hard-tissue dimensions were similar at sites prepared with either drills or Sonosurgery(®) .

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To evaluate the peri-implant soft and hard tissue adaptation at implants with different modified surfaces and configurations. Six Beagle dogs were used. Mandibular premolars and first molars were extracted bilaterally. After 3 months, full-thickness flaps were elevated, and two different types of trans-mucosal implants (ICX-Gold®, Medentis Medical GmbH, Dernau, Germany and SLActive®, Institute Straumann, Bern, Switzerland) and two different surfaces were randomly installed in the distal regions of one side of the mandible. Abutments were applied, and a nonsubmerged healing was allowed. After 1 month, the procedures were performed in the other side of the mandible, and after a further month, the animals were sacrificed, biopsies were collected, and ground sections prepared for histological examination. Similar results in marginal bone and soft tissues dimensions were observed after 1 month of healing at the two implant systems used, and no major changes could be observed after 2 months of healing. After 1 month, the percentage of new bone was 69.0% and 68.8% at ICX-Gold and SLActive surfaces, respectively. After 2 months, the percentage of new bone was 67.8% and 71.9% at ICX-Gold Medentis and SLActive surfaces, respectively. No statistically significant differences in osseointegration were found. The two implant systems used resulted in similar osseointegration after 1 and 2 months of healing.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The oral anticoagulants (AOC) and platelet antiagregants are drugs used for the prevention of thromboembolic phenomena, such as pulmonary embolism in patients with atrial fribrilation heart valves, thrombosis and pulmonary embolism. For patients who are undergoing surgical procedures-dentistry were asked to discontinue the use of anticoagulants until the value of the INR remained = 2.0, that in order to avoid trans and hemorrhages in the postoperative period. However, the AOC can cause the formation of a clot, leading to obstruction of blood pathways. Thus, it became doubtful the medicine for surgery, in which local hemostatic measures would be sufficient to promote hemostasis. Thus, the objective of the review was to evaluate the risk of bleeding in patients AOC users that are subjected to surgical procedures, through a bibliographical survey carried out in relevant clinical studies published between 1990 and 2012, by the MedlinePubMed data. In this review of literature was concluded that the benefit of thromboembolism prevention overcomes the risk hemorrhage, therefore, it is recommended to keep the dose of anticoagulant therapy unchanged for patients undergoing oral surgery and implant dentistry, using appropriate INR levels with the assistance of local hemostatic. In addition, a refined surgical technique should be performed in these patients. With respect to the most invasive oral surgery, with a risk of bleeding, treatment may be necessary in conjunction with the medical staff.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this literature review was to evaluate the use of fibrin tissue adhesive in implant dentistry. Materials and Methods: A literature search of Medline-PubMed for articles published, describing the use of fibrin tissue adhesive in implant dentistry was performed and articles were critically reviewed. Results: The literature review reveals clinical trials and experimental studies with regard to the use of fibrin tissue adhesive in implant dentistry. This material consists of 2 components: highly purified, freeze-dried human fibrinogen with factor XIII and a starter solution containing human thrombin. Clotting factor XIII is admitted for reinforcement of the fibrin network. The components are reconstituted before use and when mixed form a clot by mimicking the terminal phase of the physiological clotting cascade. Several studies showed that fibrin tissue adhesive is fully absorbed by macrophages within 2 weeks of application. Adhesive fibrin tissue may be used for to prevent bone loss, to create contour in the periimplant soft tissue and osseous tissue, to sculpt emergence profile for prosthetic components and to mimic tissue architecture. In the last years fibrin tissue adhesive also find use as material for the controlled delivery of drugs and biologics. Conclusions: The fibrin tissue adhesive presents good properties such as biocompatibility, hemostatic properties and ability to break down like the physiologic clot. This material, alone or associated with other materials, can be used with the implants immediately after extraction. In this condition it brings the necessary anchoring and efficient maintenance of osseous/mucosal contour, which it is important for the clinical success.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There are few studies that evaluate the legal aspects, consent forms and ethical considerations facing implantology. This paper reviews and discusses the most important criteria in relation to the care of patients needing dental implants. Used the following databases: Medline (Pubmed), Dentistry Oral Science , Scielo, Athenas (Dissertation / Thesis), Digital Library of UNICAMP (Dissertation / Thesis), Digital Library of USP (Dissertation / Thesis) over the past 15 years . The inclusion and exclusion criteria were clinical articles, resulting from expert opinion on the subject of review and longitudinal follow-up who have studied or reported on the ethical aspects in implant dentistry; were excluded studies whose language was not English or Portuguese. Of a total of 52 articles and theses, after an analysis according to inclusion and exclusion criteria, 26 were selected. The literature shows that the safe practice of implantology is indispensable for the success of therapy. Respect the ethical, legal and make it explicit relationship with the patient (informed consent, information) are an important factor in the success of rehabilitative treatment. Since this treatment is long term, professional dental implant requires all documentation and clarity in time to offer treatment to the patient and professional expectations are met.