995 resultados para immediate dental implant loading
Resumo:
The aim of this study was to evaluate the biomechanical behavior of different implant connection types, by means of three-dimensional finite element analysis. 3 Three-dimensional models were created with a graphic modeling software: SolidWorks 2006 and Rhinoceros 4.0, and InVesalius (CTI, São Paulo, Brasil), the bone was obtained by computerized tomography of a sagittal section of the molar region. The model was composed by bone block with an implant (4 x 10 mm) (Conexão Sistemas de Prótese, São Paulo), with different implant connections: external hex, internal hex and Morse-taper with the corresponding prosthetic component Ucla or Morse-taper abutment. The Three-dimensional models were transferred to finite element software Femap 10.0 (Siemens PLM Software Inc., CA, USA), to generate a mesh, boundary conditions and loading. An axial (200N) and oblique load (100N) was applied on the occlusal surface of the crowns. Analyses were performed using the finite element software NEiNastran 9.0 (Noran Engineering, Inc., USA) and transferred to the Femap 10.0 to obtain the results; after the results were visualized using von Mises stress maps and Maximum stress principal. The results showed the stress distribution was similar between models, with a little superiority of Morse-taper connection. It was concluded that: the three connection types were biomechanical viable; The Morse-taper connection presented the better internal stress distribution; there was not significant biomechanical differences on the bone.
Resumo:
Objective: The use of methods for tissue regeneration has been widely applied in Implantology, in clinical situations with disabilities or anatomical limitations that prevent the placement of osseointegrated dental implants. The evolution of the development of biomaterials revolutionized this therapeutic modality, facilitating the resolution of clinical cases with tissue deficiencies. Thus, this study aimed to describe a clinical case approaching the methods, techniques, and materials used in guided bone regeneration applied to Implantology. Case report: A clinical case of a patient who received a Morse taper dental implant (region 15) is described. The use of biomaterial and membrane on the buccal wall of the socket was required. After the osseointegration period, a reopening surgery was performed, and an immediate provisional implant was produced. After 2 months of follow-up, the final prosthesis was made involving other adjacent elements. Final considerations: The guided bone regeneration technique employed showed satisfactory performance. The patient was positive regarding esthetics and function. However, more controlled studies with longer follow-up period are needed for analyses of predictability
Resumo:
Esthetics is important for success of implant-supported prostheses. This study aimed to review esthetics concepts for implant treatment. Research in the PubMed database included studies published from 1995 to 2010 with the keywords implant esthetics, implant-supported prostheses, and esthetics. Forty-five studies were evaluated regarding the presurgical planning, surgical phase, and temporary and final restoration phases. It was concluded that esthetics in implant-supported prostheses results from a multidisciplinary approach from planning until insertion of the final restoration.
Resumo:
Objectives: to evaluate implant survival immediately placed after tooth extraction considering different sites, prosthodontic modalities, and the need for biomaterials. Material and methods: dental records of 500 patients treated with dental implants between 2004 and 2011 were screened. Results: only 200 records (20%) corresponded to immediate implants. Reasons for tooth extraction included extensive caries, bone loss, and root fractures. From the 197 immediate dental implants, 86 were placed in the maxilla with a survival rate of 93.9% and 111 in the mandible (survival rate of 99.1%). The overall survival rate was 97.46%. Prosthodontic modalities identified were: Brånemark classic complete denture screwed prostheses (36%), overdentures (5.6%), fixed partial denture (31%), and single-tooth prostheses (27.4%). Also, it was observed that in 33% of cases there was a need for the use of grafts and/or biomaterials. Conclusion: it can be concluded that, when correctly indicated, immediate implants are an excellent choice. The anterior mandibular region, screwed and overdenture-type prostheses presented higher success rates when associated to immediate implant placement. The need for bone graft/biomaterial does not affect the clinical results.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
PURPOSE. The aim of the present study was to evaluate if a smaller morse taper abutment has a negative effect on the fracture resistance of implant-abutment connections under oblique compressive loads compared to a conventional abutment MATERIALS AND METHODS. Twenty morse taper conventional abutments (4.8 mm diameter) and smaller abutments (3.8 mm diameter) were tightened (20 Ncm) to their respective implants (3.5 x 11 mm) and after a 10 minute interval, implant/abutment assemblies were subjected to static compressive test, performed in a universal test machine with 1 mm/min displacement, at 45 degrees inclination. The maximum deformation force was determined. Data were statistically analyzed by student t test. RESULTS. Maximum deformation force of 4.8 mm and 3.8 mm abutments was approximately 95.33 kgf and 95.25 kgf, respectively, but no fractures were noted after mechanical test. Statistical analysis demonstrated that the evaluated abutments were statistically similar (P=.230). CONCLUSION. Abutment measuring 3.8 mm in diameter (reduced) presented mechanical properties similar to 4.8 mm (conventional) abutments, enabling its clinical use as indicated. [J Adv Prosthodont 2012;4:158-61]
Resumo:
Background: In sites with diminished bone volume, the osseointegration of dental implants can be compromised. Innovative biomaterials have been developed to aid successful osseointegration outcomes. Purpose: The aim of this study was to evaluate the osteogenic potential of angiogenic latex proteins for improved bone formation and osseointegration of dental implants. Materials and Methods: Ten dogs were submitted to bilateral circumferential defects (5.0 x 6.3 mm) in the mandible. Dental implant (3.3 x 10.0 mm, TiUnite MK3 (TM), Nobel Biocare AB, Goteborg, Sweden) was installed in the center of the defects. The gap was filled either with coagulum (Cg), autogenous bone graft (BG), or latex angiogenic proteins pool (LPP). Five animals were sacrificed after 4 weeks and 12 weeks, respectively. Implant stability was evaluated using resonance frequency analysis (Osstell Mentor T, Osstell AB, Goteborg, Sweden), and bone formation was analyzed by histological and histometric analysis. Results: LPP showed bone regeneration similar to BG and Cg at 4 weeks and 12 weeks, respectively (p >= 3.05). Bone formation, osseointegration, and implant stability improved significantly from 4 to 12 weeks (p <= 2.05). Conclusion: Based on methodological limitations of this study, Cg alone delivers higher bone formation in the defect as compared with BG at 12 weeks; compared with Cg and BG, the treatment with LPP exhibits no advantage in terms of osteogenic potential in this experimental model, although overall osseointegration was not affected by the treatments employed in this study.
Resumo:
Objectives: Because the mechanical behavior of the implant-abutment system is critical for the longevity of implant-supported reconstructions, this study evaluated the fatigue reliability of different implant-abutment systems used as single-unit crowns and their failure modes. Methods and Materials: Sixty-three Ti-6Al-4V implants were divided in 3 groups: Replace Select (RS); IC-IMP Osseotite; and Unitite were restored with their respective abutments. Anatomically correct central incisor metal crowns were cemented and subjected to separate single load to failure tests and step-stress accelerated life testing (n = 18). A master Weibull curve and reliability for a mission of 50,000 cycles at 200 N were calculated. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The load at failure mean values during step-stress accelerated life testing were 348.14 N for RS, 324.07 N for Osseotite, and 321.29 N for the Unitite systems. No differences in reliability levels were detected between systems, and only the RS system mechanical failures were shown to be accelerated by damage accumulation. Failure modes differed between systems. Conclusions: The 3 evaluated systems did not present significantly different reliability; however, failure modes were different. (Implant Dent 2012;21:67-71)
Resumo:
PURPOSE: The purpose of this prospective study on humans were to evaluate (a) the clinical outcome of alveolar distraction osteogenesis for the correction of vertically deficient edentulous mandibular ridges, (b) the clinical outcome of dental implants placed in the distracted areas, and (c) the quality and quantity of the bone that had formed in the distraction gap. MATERIAL AND METHODS: Seven patients presenting vertically deficient edentulous ridges were treated by means of distraction osteogenesis with an intraoral alveolar distractor. Approximately 3 months after consolidation of the distracted segments, 20 ITI solid screw SLA implants were placed in the distracted areas. Three to 4 months later, abutments were connected and prosthetic loading of the implants started. During implant site preparation, bone biopsies were taken at the implant sites with trephine burrs for histologic and histometric analyses. RESULTS: The mean follow-up after the initial prosthetic loading was 18 months (range 12-24 months). The mean bone gain obtained at the end of distraction was 7 mm (range 5-9 mm). The cumulative success rate of implants 2 years after the onset of prosthetic loading was 95%, whereas the survival rate of implants was 100%. The newly formed bone consisted of woven bone reinforced by parallel-fibered bone with bone marrow spaces between the bone trabeculae. The bone area fraction in the distraction region ranged from 21.6% to 57.8% (38.5+/-11.7%). DISCUSSION AND CONCLUSIONS: Results from this study showed that (a) distraction osteogenesis is a reliable technique for the correction of vertically deficient edentulous ridges, (b) the regenerated bone withstood the functional demands of implant loading, (c) survival and success rates of implants placed in the distracted areas were consistent with those of implants placed in native bone, and (d) there is sufficient bone volume and maturity in the distracted region for primary stability of the implant.
Resumo:
PURPOSE: The objective of the present experiment was to study the morphogenesis of the mucosal attachment to implants made of c.p. titanium. MATERIAL AND METHODS: All mandibular premolars were extracted in 20 Labrador dogs. After a healing period of 3 months, four implants (ITI Dental Implant System) were placed in the right and left sides of the mandible. A non-submerged implant installation technique was used and the mucosal tissues were secured to the conical marginal portion of the implants with interrupted sutures. The sutures were removed after 2 weeks and a plaque control program including daily cleaning of the remaining teeth and the implants was initiated. The animals were sacrificed and biopsies were obtained at various intervals to provide healing periods extending from Day 0 (2 h) to 12 weeks. The mandibles were removed and placed in the fixative. The implant sites were dissected using a diamond saw and processed for histological analysis. RESULTS: Large numbers of neutrophils infiltrated and degraded the coagulum that occupied the compartment between the mucosa and the implant during the initial phase of healing. At 2 weeks after surgery, fibroblasts were the dominating cell population in the connective tissue interface but at 4 weeks the density of fibroblasts had decreased. Furthermore, the first signs of epithelial proliferation were observed in specimens representing 1-2 weeks of healing and a mature barrier epithelium occurred after 6-8 weeks of healing. The collagen fibers of the mucosa were organized after 4-6 weeks of healing. CONCLUSION: It is suggested that the soft-tissue attachment to implants placed using a non-submerged installation procedure is properly established after several weeks following surgery.
Resumo:
Background: The goal of this study was to retrospectively analyze a cohort of 136 patients who underwent dental implant placement in the posterior maxilla at the University of Connecticut Health Center to assess and identify predictors for implant failure in the posterior maxilla. Methods: Data were retrieved from patient charts to identify subjects older than 21 years of age who received dental implant(s) in the posterior maxilla. Patients without a postoperative baseline radiograph were excluded. A recall radiograph was taken 3 to 6 months after implant placement. If there was no recall radiograph, the subject was contacted for a recall visit that included a clinical evaluation and radiographs to determine the implant status. Based on a univariate screening, variables considered potential implant failure predictors included gender, diabetes, smoking, implant length, implant diameter, membrane use, sinus-elevation technique, and surgical complications. These parameters were further assessed, and a multivariable logistic regression was performed with implant failure as a dependant variable. All tests of significance were evaluated at the 0.05 error level. Results: Two hundred seventy-three implants were placed in the posterior maxilla. Fourteen implants failed (early and late failures combined), resulting in a 94.9% overall survival rate. The survival rates for the sinus-elevation group and native bone group were 92.2% and 96.7%, respectively (P = 0.090). Based on the multivariable analysis, sinus floor-elevation procedures were not associated with increased risk for implant failure (P = 0.702). In contrast, smoking and surgical complications had a statistically significant effect on implant failure; the odds ratios for implant failure were 6.4 (P = 0.025) and 8.2 (P = 0.004), respectively. Conclusion: Sinus-elevation procedures with simultaneous or staged implant placement do not increase the risk for implant failure, whereas smoking and surgical complications markedly increase the risk for implant failure.
Resumo:
PURPOSE: To systematically appraise the impact of mechanical/technical risk factors on implant-supported reconstructions. MATERIAL AND METHODS: A MEDLINE (PubMed) database search from 1966 to April 2008 was conducted. The search strategy was a combination of MeSH terms and the key words: design, dental implant(s), risk, prosthodontics, fixed prosthodontics, fixed partial denture(s), fixed dental prosthesis (FDP), fixed reconstruction(s), oral rehabilitation, bridge(s), removable partial denture(s), overdenture(s). Randomized controlled trials, controlled trials, and prospective and retrospective cohort studies with a mean follow-up of at least 4 years were included. The material evaluated in each study had to include cases with/without exposure to the risk factor. RESULTS: From 3,568 articles, 111 were selected for full text analysis. Of the 111 articles, 33 were included for data extraction after grouping the outcomes into 10 risk factors: type of retentive elements supporting overdentures, presence of cantilever extension(s), cemented versus screw-retained FDPs, angled/angulated abutments, bruxism, crown/implant ratio, length of the suprastructure, prosthetic materials, number of implants supporting an FDP, and history of mechanical/technical complications. CONCLUSIONS: The absence of a metal framework in overdentures, the presence of cantilever extension(s) > 15 mm and of bruxism, the length of the reconstruction, and a history of repeated complications were associated with increased mechanical/technical complications. The type of retention, the presence of angled abutments, the crown-implant ratio, and the number of implants supporting an FDP were not associated with increased mechanical/technical complications. None of the mechanical/technical risk factors had an impact on implant survival and success rates.
Resumo:
AIM: To assess soft tissues healing at immediate transmucosal implants placed into molar extraction sites with buccal self-contained dehiscences. MATERIAL AND METHODS: For this 12-month controlled clinical trial, 15 subjects received immediate transmucosal tapered-effect (TE) implants placed in molar extraction sockets displaying a buccal bone dehiscence (test sites) with a height and a width of > or =3 mm, respectively. Peri-implant marginal defects were treated according to the principles of Guided Bone Regeneration (GBR) by means of deproteinized bovine bone mineral particles in conjunction with a bioresorbable collagen membrane. Fifteen subjects received implants in healed molar sites (control sites) with intact buccal alveolar walls following tooth extraction. In total, 30 TE implants with an endosseous diameter of 4.8 mm and a shoulder diameter of 6.5 mm were used. Flaps were repositioned and sutured, allowing non-submerged, transmucosal soft tissues healing. At the 12-month follow-up, pocket probing depths (PPD) and clinical attachment levels (CAL) were compared between implants placed in the test and the control sites, respectively. RESULTS: All subjects completed the 12-month follow-up period. All implants healed uneventfully, yielding a survival rate of 100%. After 12 months, statistically significantly higher (P<0.05) PPD and CAL values were recorded around implants placed in the test sites compared with those placed in the control sites. CONCLUSIONS: The findings of this controlled clinical trial showed that healing following immediate transmucosal implant installation in molar extraction sites with wide and shallow buccal dehiscences yielded less favorable outcomes compared with those of implants placed in healed sites, and resulted in lack of 'complete' osseointegration.
Resumo:
PURPOSE The purpose of the present study was to evaluate the thickness and anatomic characteristics of the sinus membrane using cone beam computed tomography (CBCT) in patients evaluated for implant surgery in the posterior maxilla. MATERIALS AND METHODS The study included 131 consecutive patients referred for dental implant placement in the posterior maxilla. A total of 138 CBCT images was obtained using fields of view of 4 × 4 cm, 6 × 6 cm, or 8 × 8 cm. Reformatted sagittal CBCT slices were analyzed with regard to the thickness and characteristics of the sinus membrane at single-tooth gaps in the posterior maxilla. Factors that might influence the dimensions of the sinus membrane, such as age, sex, endodontic status, and the season, were analyzed. RESULTS The mean thickness of the maxillary sinus mucosa varied between 2.1 and 2.69 mm in the three locations analyzed. Fewer than half of the evaluated sinuses exhibited a healthy mucosa (49 of 138, or 35.51%). Most of the pathologic findings were flat, shallow thickenings (63 of 138, or 45.65%). Sex did not influence the thickness of the sinus membrane at the root tips of the premolars or at single-tooth gaps, but there was a statistically significant correlation in the region of the maxillary molars. No other evaluated factors had a statistically significant effect on the dimensions of the antral mucosa. CONCLUSIONS In the present study, sex was the only factor influencing the dimension of the sinus membrane, whereas patient age, season, and the endodontic status of neighboring teeth had no significant effect on the thickness of the antral mucosa. Future studies should address which types of mucosal thickening require interdisciplinary therapy.
Resumo:
OBJECTIVES The aim was to study the impact of the defect size of endodontically treated incisors compared to dental implants as abutments on the survival of zirconia two-unit anterior cantilever-fixed partial dentures (2U-FPDs) during 10-year simulation. MATERIALS AND METHODS Human maxillary central incisors were endodontically treated and divided into three groups (n = 24): I, access cavities rebuilt with composite core; II, teeth decoronated and restored with composite; and III as II supported by fiber posts. In group IV, implants with individual zirconia abutments were used. Specimens were restored with zirconia 2U-FPDs and exposed to two sequences of thermal cycling and mechanical loading. Statistics: Kaplan-Meier; log-rank tests. RESULTS During TCML in group I two tooth fractures and two debondings with chipping were found. Solely chippings occurred in groups II (2×), IV (2×), and III (1×). No significant different survival was found for the different abutments (p = 0.085) or FPDs (p = 0.526). Load capability differed significantly between groups I (176 N) and III (670 N), and III and IV (324 N) (p < 0.024). CONCLUSION Within the limitations of an in vitro study, it can be concluded that zirconia-framework 2U-FPDs on decoronated teeth with/without post showed comparable in vitro reliability as restorations on implants. The results indicated that restorations on teeth with only access cavity perform worse in survival and linear loading. CLINICAL RELEVANCE Even severe defects do not justify per se a replacement of this particular tooth by a dental implant from load capability point of view.