947 resultados para hyperspectral imaging
Resumo:
Purpose: To assess the association of prevalent bone marrow edema-like lesions (BMLs) and full-thickness cartilage loss with incident subchondral cyst-like lesions (SCs) in the knee to evaluate the bone contusion versus synovial fluid intrusion theories of SC formation. Materials and Methods: The Multicenter Osteoarthritis study is a longitudinal study of individuals who have or are at risk for knee osteoarthritis. The HIPAA-compliant protocol was approved by the institutional review boards of all participating centers, and written informed consent was obtained from all participants. Magnetic resonance images were acquired at baseline and 30-month follow-up and read semiquantitatively by using the Whole-Organ Magnetic Resonance Imaging Score system. The tibiofemoral and patellofemoral joints were subdivided into 14 subregions. BMLs and SCs were scored from 0 to 3. Cartilage morphology was scored from 0 to 6. The association of prevalent BMLs and full-thickness cartilage loss with incident SCs in the same subregion was assessed by using logistic regression with mutual adjustment for both predictors. Results: A total of 1283 knees were included. After adjustment for full-thickness cartilage loss, prevalent BMLs showed a strong and significant association with incident SCs in the same subregion, with an odds ratio of 12.9 (95% confidence interval [CI]: 8.9, 18.6). After adjustment for BMLs, prevalent full-thickness cartilage loss showed a significant but much less important association with incident SCs in the same subregion (odds ratio, 1.4; 95% CI: 1.0, 2.0). There was no apparent relationship between severity of full-thickness cartilage loss at baseline and incident SCs. Conclusion: Prevalent BMLs strongly predict incident SCs in the same subregion, even after adjustment for full-thickness cartilage loss, which supports the bone contusion theory of SC formation. (C) RSNA, 2010
Resumo:
An analyzer-based X-ray phase-contrast imaging (ABI) setup has been mounted at the Brazilian Synchrotron Light Laboratory (LNLS) for multiple imaging radiography (MIR) purposes. The algorithm employed for treating the MIR data collected at LNLS is described, and its reliability in extracting the distinct types of contrast that can be obtained with MIR is demonstrated by analyzing a test sample (thin polyamide wire). As a practical application, the possibility of studying ophthalmic tissues, corneal sequestra in this case, via MIR is investigated. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Objectives: The aims of this study were to evaluate the visibility of the lateral pterygoid muscle (LPM) in temporomandibular joint (TMJ) images obtained by MRI, using different projections and to compare image findings with clinical symptoms of patients with and without temporomandibular disorders (TMD). Methods: In this study, LPM images of 50 participants with and without TMDs were investigated by MRI. The images of the LPM in different projections of 100 TMJs from 35 participants (70 TMJs) with and 15 participants (30 TMJs) without clinical signs and symptoms of TMD were visible and analysed. Results: The oblique sagittal and axial images of the TMJ clearly showed the LPM. Hypertrophy (1.45%), atrophy (2.85%) and contracture (2.85%) were the abnormalities found in the LPM. TMD signs, such as hypermobility (11.4%), hypomobility (12.9%) and disc displacement (20.0%), could be seen in TMJ images. Related clinical symptoms, such as pain (71.4%), articular sounds (30.4%), bruxism (25.7%) and headache (22.9%), were observed. Conclusions: Patients with TMD can present with alterations in the LPM thickness. Patients without TMD also showed alterations, such as atrophy and contracture, in TMJ images. Recognition of alterations in the LPM will improve our understanding of clinical symptoms and pathophysiology of TMD, and may lead to a more specific diagnosis of these disorders. Dentomaxillofacial Radiology (2010) 39, 494-500. doi: 10.1259/dmfr/80928433
Resumo:
An assessment of the bi-directional reflectance distribution function (BRDF) of corals with different morphologies was undertaken using hyperspectral reflectance measurements. The highest variance in reflectance obtained at different viewing angles was found for the open branching Acropora colony, possibly attributed to branch orientation and internal shadow distribution. Spectral separation within and between features at the nominated sensor-viewing angles was greatest in the near infrared portion of the spectrum. The analysis of coral reef bi-directional reflectance properties and degree of internal shadowing holds potential for future assessment and information extraction relating to coral structural characteristics.
Resumo:
The diffusion of water into a series of hydroxyethyl methacrylate, HEMA, copolymers with tetrahydrofurfuryl methacrylate, THFMA, has been studied over a range of copolymer compositions using NMR imaging analyses. For polyHEMA the diffusion was found to be consistent with a Fickian model. The mass diffusion coefficient of water in polyHEMA at 37 degreesC was determined from the profiles of the diffusion front to be 1.5 x 10(-11) m(2) s(-1), which is less than the value based upon mass uptake, 2.0 x 10(-11) m(2) s(-1). The profiles of the water diffusion front obtained from the NMR images showed that stress was induced at the interface between the rubbery and glassy regions which led to formation of small cracks in this region of the glassy matrix of polyHEMA and its copolymers with mole fractions of HEMA greater than 0.6. Water was shown to be able to enter these cracks forming water pools. For copolymers of HEMA and THFMA with mole fractions of HEMA less than 0.6 the absence of cracks was attributed to the ability of the THFMA sequences to undergo stress relaxation by creep.
Resumo:
Synthetic aperture radar (SAR) images of resonant buried objects are modelled in the presence of ground surface clutter. The method of moments (MoM) is used to model scattered fields from a resonant buried conductor and clutter is modelled as a bivariant Gaussian distribution. A diffraction stack SAR imaging technique is applied to the ultra-wideband waveforms to give a bipolar signal image. A number of examples have been computed to illustrate the combined effects of SAR processing with resonant targets and clutter. SAR images of different targets show differences which may facilitate target identification. To maximise the peak signal-to-clutter ratio, an image correlation technique is applied and the results are shown.
Resumo:
A prospective clinical study was carried out to evaluate the influence of posture on perineal ultrasound imaging parameters. One hundred and thirty-two consecutive women presenting with symptoms of lower urinary tract dysfunction were examined by multichannel videourodynamics and perineal ultrasound, both supine and standing. Ultrasound included color Doppler imaging when available, i.e. in a subgroup of 99 patients. The position of the bladder neck at rest was higher in the supine position (P
Resumo:
In a prospective study 105 patients with symptoms of stress incontinence underwent video-urodynamic testing, including resting urethral pressure profilometry and translabial ultrasound. The urethral pressure profile (UPP) included maximum urethral closure pressure (MUCP), functional length (FL) and area under the curve (AUC). Ultrasound parameters included urethral thickness, urethral rotation and bladder neck descent, as well as funneling/opening of the internal urethral meatus on Valsalva maneuver. Levator contraction strength was assessed measuring the cranioventral displacement of the internal meatus. Negative correlations between UPP data and age, parity and previous surgery were observed which were consistent with literature data. There was a positive correlation :between the urethral AP diameter on ultrasound and the MUCP, which agrees with reports showing reduced sphincter thickness or volume in stress-incontinent women. Hypermobility on ultrasound did not correlate with UPP data. However, a lower MUCP correlated with extensive opening of the bladder neck. Finally, there was a trend towards poorer pelvic floor function with lower MUCP measurements.
Resumo:
When patients undergo a magnetic resonance imaging scan, they are subject to both strong static and temporal magnetic fields. The temporal fields are designed to vary at each point in the region being imaged. This is achieved by the use of gradient coils. However, when the gradient coils are switched very rapidly, the strongly time-varying magnetic fields produced can be responsible for stimulating nerves in the peripheral regions of the body. This paper gives a somewhat novel explanation for this phenomenon. The physical mechanism suggested is supported by an illustrative theoretical calculation.
Resumo:
New designs for force-minimized compact high-field clinical MRI magnets are described. The design method is a modified simulated annealing (SA) procedure which includes Maxwell forces in the error function to be minimized. This permits an automated force reduction in the magnet designs while controlling the overall dimensions of the system. As SA optimization requires many iterations to achieve a final design, it is important that each iteration in the procedure is rapid. We have therefore developed a rapid force calculation algorithm. Novel designs for short 3- and 4-T clinical MRI systems are presented in which force reduction has been invoked. The final designs provide large homogeneous regions and reduced stray fields in remarkable short magnets. A shielded 4-T design that is approximately 30% shorter than current designs is presented. This novel magnet generates a full 50-cm diameter homogeneous region.