948 resultados para fluorescent PCR


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report within this paper the development of a fiber-optic based sensor for Hg(II) ions. Fluorescent carbon nanoparticles were synthesized by laser ablation and functionalized with PEG200 and N-acetyl-l-cysteine so they can be anionic in nature. This characteristic facilitated their deposition by the layer-by-layer assembly method into thin alternating films along with a cationic polyelectrolyte, poly(ethyleneimine). Such films could be immobilized onto the tip of a glass optical fiber, allowing the construction of an optical fluorescence sensor. When immobilized on the fiber-optic tip, the resultant sensor was capable of selectively detecting sub-micromolar concentrations of Hg(II) with an increased sensitivity compared to carbon dot solutions. The fluorescence of the carbon dots was quenched by up to 44% by Hg(II) ions and interference from other metal ions was minimal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado, Tecnologia e Segurança Alimentar, 21 de Novembro de 2014, Universidade dos Açores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado, Ciências Biomédicas, 3 de Fevereiro de 2016, Universidade dos Açores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new fluorescent sensor for nitric oxide (NO) is presented that is based on its reaction with a non fluorescent substance, reduced fluoresceinamine, producing the highly fluorescent fluoresceinamine. Using a portable homemade stabilized light source consisting of 450 nm LED and fiber optics to guide the light, the sensor responds linearly within seconds in the NO concentration range between about 10–750 µM with a limit of detection (LOD) of about 1 µM. The system generated precise intensity readings, with a relative standard deviation of less than 1%. The suitability of the sensor was assessed by monitoring the NO generated by either the nitrous acid decomposition reaction or from a NO-releasing compound. Using relatively high incubation times, the sensor also responds quantitatively to hydrogen peroxide and potassium superoxide, however, using transient signal measurements results in no interfering species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Agência Financiadora: Fundação para a Ciência e a Tecnologia/MCTES (Portugal) - PEst-OE/EQB/UI0702/2012

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New sensory materials based on p-phenylene ethynylene trimers integrating calix[4]arene receptors (CALIX-PET) and tert-butylphenol (TBP-PET) moieties have been synthesized and their sensitivity and selectivity for the detection of nitroaromatic compounds (NACs) such as nitrobenzene (NB), 2,4-dinitrotoluene (2,4-DNT), 2,4,6-trinitrotoluene (TNT) and picric acid (PA) investigated in fluid phase and solid-state. It was found that both fluorophores displayed high sensitivities toward NACs detection in solution as evaluated by the Stern-Volmer formalism. For all the tested explosives, the ratio of fluorescence intensities (F-0/F) is a linear function of the quencher concentration only after appropriate correction of fluorescence quenching data for inner-filter effects. The quenching efficiencies for CALIX-PET and TBP-PET follow the order PA >> TNT > DNT > NB, which correlate well with the quenchers electron affinities as evaluated from their LUMOs energies thereby suggesting a photoinduced electron transfer as the dominant mechanism of fluorescence quenching. The selectivity of these sensors was checked against exemplar interferents possessing differentiated electronic properties (benzoic acid, 2,4-dichlorophenol and benzoquinone) and reduced quenching activity was detected. The quenching efficiencies and response times of the two fluorophores in the solid-state toward NB, 2,4-DNT and TNT vapors were evaluated through steady-state fluorescence quenching experiments with the materials dispersed in polymeric matrices or as neat films. The most significant fluorescence quenching responses were achieved for drop-casted films of TBP-PET upon exposure to nitroaromatics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Performance indexes of the peroxidase antibody test were compared to that of the fluorescent antibody test. The peroxidase antibody test had a statistically higher sensitivity and negative predictive value and a higher efficiency than the fluorescent antibody test but its specificity and positive predictive value were within the 95% confidence limits for the values found for the fluorescent antibody test. Such differences did not change when Chagas' disease and visceral leishmaniasis sera were included in index calculations. Statistical analysis showed that the two tests have a substantial degree of agreement but the immunofluorescent test had a specificity index and a positive predictive value equal to 100.0% when Chagas' disease and visceral leishmaniasis sera were not included in the calculations of the performance index; in this instance, a positive test result equals a disclosure of the disease attribute due to the inexistence of false positive results. The enzyme/ protein ratio of the peroxidase conjugate, resulting in heavy or light-labeled conjugates may pose technical problems to its use in serology tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glucose monitoring in vivo is a crucial issue for gaining new understanding of diabetes. Glucose binding protein (GBP) fused to two fluorescent indicator proteins (FLIP) was used in the present study such as FLIP-glu- 3.2 mM. Recombinant Escherichia coli whole-cells containing genetically encoded nanosensors as well as cell-free extracts were immobilized either on inner epidermis of onion bulb scale or on 96-well microtiter plates in the presence of glutaraldehyde. Glucose monitoring was carried out by Förster Resonance Energy Transfer (FRET) analysis due the cyano and yellow fluorescent proteins (ECFP and EYFP) immobilized in both these supports. The recovery of these immobilized FLIP nanosensors compared with the free whole-cells and cell-free extract was in the range of 50–90%. Moreover, the data revealed that these FLIP nanosensors can be immobilized in such solid supports with retention of their biological activity. Glucose assay was devised by FRET analysis by using these nanosensors in real samples which detected glucose in the linear range of 0–24 mM with a limit of detection of 0.11 mM glucose. On the other hand, storage and operational stability studies revealed that they are very stable and can be re-used several times (i.e. at least 20 times) without any significant loss of FRET signal. To author's knowledge, this is the first report on the use of such immobilization supports for whole-cells and cell-free extract containing FLIP nanosensor for glucose assay. On the other hand, this is a novel and cheap high throughput method for glucose assay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simplified fluorescence inhibition microtest (SFIMT) was standardized for the evaluation of antirabies serum neutralizing antibodies based on the rapid fluorescent focus inhibition test (RFFIT) and the fluorescence inhibition microtest (FIMT). The simplified test showed reproductibility similar to that of the FIMT with advantages as easier executation and quicker reading. A simple pre-treatment of Brazilian microplates produced for immune enzymatic assays (PROSIL) gave equivalent results and substantial coast reduction, in relation to imported plates (DIFCO). The simplified test can be easily implemented in less sophisticated laboratories, as alternative to the mouse serum neutralization test, still the most largely employed in Brazil, or even to others as RFFIT and FIMT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data concerning HCV infection in Central Brazil are rare. Upon testing 2,350 voluntary blood donors from this region, we found anti-HCV prevalence rates of 2.2% by a second generation ELISA and 1.4% after confirmation by a line immunoassay. Antibodies against core, NS4, and NS5 antigens of HCV were detected in 81.8%, 72.7%, and 57.5%, respectively, of the positive samples in the line immunoassay. HCV viremia was present in 76.6% of the anti-HCV-positive blood donors. A relation was observed between PCR positivity and serum reactivity in recognizing different HCV antigens in the line immunoassay. The majority of the positive donors had history of previous parenteral exposure. While the combination of ALT>50 IU/l and anti-HBc positivity do not appear to be good surrogate markers for HCV infection, the use of both ALT anti-HCV tests is indicated in the screening of Brazilian blood donors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do grau de Doutor em Biotecnologia pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia. A presente dissertação foi preparada no âmbito do protocolo de acordo bilateral de educação avançada (ERASMUS) entre a Universidade de Vigo e a Universidade Nova de Lisboa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Supernatant of boiled spleen saline-suspensions of Yersinia pestis experimentally infected animals were used as template for PCR amplification without DNA extraction. PCR sensitivity was enhanced by a second round of amplification (Nested). No amplification was observed from non-infected animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show here a simplified RT-PCR for identification of dengue virus types 1 and 2. Five dengue virus strains, isolated from Brazilian patients, and yellow fever vaccine 17DD as a negative control, were used in this study. C6/36 cells were infected and supernatants were collected after 7 days. The RT-PCR, done in a single reaction vessel, was carried out following a 1/10 dilution of virus in distilled water or in a detergent mixture containing Nonidet P40. The 50 µl assay reaction mixture included 50 pmol of specific primers amplifying a 482 base pair sequence for dengue type 1 and 210 base pair sequence for dengue type 2. In other assays, we used dengue virus consensus primers having maximum sequence similarity to the four serotypes, amplifying a 511 base pair sequence. The reaction mixture also contained 0.1 mM of the four deoxynucleoside triphosphates, 7.5 U of reverse transcriptase, 1U of thermostable Taq DNA polymerase. The mixture was incubated for 5 minutes at 37ºC for reverse transcription followed by 30 cycles of two-step PCR amplification (92ºC for 60 seconds, 53ºC for 60 seconds) with slow temperature increment. The PCR products were subjected to 1.7% agarose gel electrophoresis and visualized by UV light after staining with ethidium bromide solution. Low virus titer around 10 3, 6 TCID50/ml was detected by RT-PCR for dengue type 1. Specific DNA amplification was observed with all the Brazilian dengue strains by using dengue virus consensus primers. As compared to other RT-PCRs, this assay is less laborious, done in a shorter time, and has reduced risk of contamination

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a case of prenatal diagnosis of congenital rubella. After birth, in addition to traditional serologic and clinical examinations to confirm the infection, we could identify the virus in the "first fluid aspirated from the oropharynx of the newborn", using polimerase chain reaction (PCR). We propose that this first oropharynx fluid (collected routinely immediately after birth) could be used as a source for identification of various congenital infection agents, which may not always be easily identified by current methods

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Herpetic infections are common complications in AIDS patients. The clinical features could be uncommon and antiviral chemotherapy is imperative. A rapid diagnosis could prevent incorrect approaches and treatment. The polymerase chain reaction is a rapid, specific and sensible method for DNA amplification and diagnosis of infectious diseases, especially viral diseases. This approach has some advantages compared with conventional diagnostic procedures. Recently we have reported a new PCR protocol to rapid diagnosis of herpetic infections with suppression of the DNA extraction step. In this paper we present a case of herpetic whitlow with rapid diagnosis by HSV-1 specific polymerase chain reaction using the referred protocol.