999 resultados para flap design
Resumo:
Objectives: To assess the vestibular fold muscle after cordectomy and laryngeal reconstruction, the pattern of motor unit recruitment during sound emission, and the morphologic characteristics of motor unit action potentials. Design: Prospective analysis. Setting: Tertiary academic hospital. Patients: We evaluated 11 men (mean age, 65.7 years; age range, 53-82 years) who underwent laryngofissure, cordectomy, and laryngeal reconstruction with a vestibular fold flap. Interventions: Laryngeal electromyography with the insertion of a needle electrode for the assessment of the electrophysiologic activity of thyroartenoid muscle fibers and of the cricothyroid muscle on the operated on and nonoperated on sides. The thyroarytenoid muscle was evaluated by introducing a needle electrode through the thyroid cartilage and the cricothyroid membrane. Main Outcome Measures: Activities of needle insertion, spontaneous muscle activity during rest, and pattern of motor unit recruitment. Results: Seven patients (64%) had vestibular fold muscle fiber, all of whom showed motor unit recruitment in response to sound emission. No neurogenic muscle injuries were observed except in 1 patient with evidence of chronic injury. Conclusion: After cordectomy and laryngeal reconstruction, thyroarytenoid muscle fibers are present in the vestibular fold, with motor unit recruitment during sound emission.
Resumo:
The present report describes an original surgical procedure for the mandibular reconstruction of 2 different defects using a single fibular flap. In addition to the habitual osteotomies, we resected a bone fragment from the middle portion of the flap, with care taken to maintain the integrity of the pedicle throughout its extension to guarantee an adequate blood supply also for the distal portion of the bone flap used for the treatment of the smaller mandibular defect. This simple maneuver permitted the reconstruction of 2 mandibular regions with well-vascularized bone tissue using a single microsurgical flap. (C) 2008 Published by Elsevier Inc.
Resumo:
Purpose: The aim of this research was to assess the dimensional accuracy of orbital prostheses based on reversed images generated by computer-aided design/computer-assisted manufacturing (CAD/CAM) using computed tomography (CT) scans. Materials and Methods: CT scans of the faces of 15 adults, men and women older than 25 years of age not bearing any congenital or acquired craniofacial defects, were processed using CAD software to produce 30 reversed three-dimensional models of the orbital region. These models were then processed using the CAM system by means of selective laser sintering to generate surface prototypes of the volunteers` orbital regions. Two moulage impressions of the faces of each volunteer were taken to manufacture 15 pairs of casts. Orbital defects were created on the right or left side of each cast. The surface prototypes were adapted to the casts and then flasked to fabricate silicone prostheses. The establishment of anthropometric landmarks on the orbital region and facial midline allowed for the data collection of 31 linear measurements, used to assess the dimensional accuracy of the orbital prostheses and their location on the face. Results: The comparative analyses of the linear measurements taken from the orbital prostheses and the opposite sides that originated the surface prototypes demonstrated that the orbital prostheses presented similar vertical, transversal, and oblique dimensions, as well as similar depth. There was no transverse or oblique displacement of the prostheses. Conclusion: From a clinical perspective, the small differences observed after analyzing all 31 linear measurements did not indicate facial asymmetry. The dimensional accuracy of the orbital prostheses suggested that the CAD/CAM system assessed herein may be applicable for clinical purposes. Int J Prosthodont 2010;23:271-276.
Resumo:
Purpose: The purpose of this study was to assess the influence of adhesive area delimitation on the microshear bond strength of different adhesives to dentin. Materials and Methods: Eighteen bovine incisors were sectioned and the exposed dentin surfaces were prepared with 600-grit SIC paper. These teeth were randomly divided into three groups, according to the adhesive to be applied: two-step etch-and-rinse Adper Single Bond 2 (3M ESPE), two-step self-etching Clearfil SE Bond (Kuraray), and one-step Clearfil S(3) Bond (Kuraray). On each dentin surface, 4 samples were built up with the composite resin Z100 (3M ESPE); on 2 of these, a suggested area delimitation technique was employed. After 24 h of storage in water at 37 degrees C, samples were subjected to the microshear bond strength test, and the failure modes were evaluated under optical and scanning electron microscopes. The obtained results were statistical analyzed using two-way ANOVA and Tukey`s test. Results: Groups without area delimitation presented significantly higher bond strength results (p < 0.05) and a higher incidence of cohesive failures. In these groups, fractures tended to occur beyond the limits of the actual adhesive area, while the area restriction technique succeeded in avoiding this phenomenon. The three adhesives performed similarly when area delimitation was employed (p > 0.05), but Clearfil S(3) Bond showed significantly higher bond strength results when no area delimitation was taken into account (p < 0.05). Conclusion: The extension of the adhesive area beyond the limits of the composite cylinder may play an important role in the results of microshear bond strength tests, while the suggested area delimitation technique may lead to less questionable outcomes.
Resumo:
This study assessed the influence of anesthetics on early complications after pharyngeal flap surgery. A 23-year retrospective chart review was carried out of all patients at the authors` institution who underwent superiorly based pharyngeal flap surgery. Variables analyzed were gender, age at the time of surgery, cleft type, anesthesia procedure used and complications in the early postoperative period. 2299 patients (50% male; 50% female) who underwent pharyngeal flap surgery between 1980 and 2003 were reviewed. The highest number of surgeries was performed in patients aged 11-20 years. There were 1042 patients with at least one type of complication. Of these, 39 required reoperation to control complications such as bleeding and airway obstruction. There were no records of death. Vomiting and pain were the most frequent postoperative complications (16% and 14% of patients, respectively). Lower complication rates were observed when anesthesia protocols included sevoflurane, propofol and opioids.
Resumo:
Objectives: To investigate the long-term effects of pharyngeal flap surgery (PFS) on nasal and nasopharyngeal dimensions of patients with velopharyngeal insufficiency (VPI) and to correlate the findings with the onset of respiratory complaints after surgery. Design/Participants: Prospective study in 58 nonsyndromic patients with repaired cleft palate and VPI, evaluated 2 days before and 5 months (POST1) and 1 year (POST2) after PFS, on average. Patients were divided into two groups: one consisting of patients with postoperative respiratory complaints (RC group) and the other without complaints (NRC group). Interventions: Superiorly based PFS. Main Outcome Measures: Respiratory complaints (self reports of mouth breathing, snoring, and other sleep obstructive events) assessed at POST1 and POST2, and minimum nasal (NCSA) and nasopharyngeal (NPA) cross-sectional areas assessed by rhinomanometry at POST2. Results: Respiratory complaints were reported by 55% and 36% of the patients evaluated at POST1 and POST2, respectively. Posterior rhinomanometry showed a significant postoperative reduction of mean NCSA in the RC and NRC groups (p < .05), to subnormal levels in some of them. The decrease was more pronounced in the RC group. No significant changes in NCSA were observed by anterior rhinomanometry. Similar results were obtained when NPA was assessed by modified anterior rhinomanometry. Conclusion: In the long-term, PFS yielded a significant reduction in upper airways dimensions beyond what should be expected and associated with persistent respiratory complaints in some cases.