974 resultados para fingerprinting, genetic algorithm-partial least squares, high performance liquid chromatography, pattern recognition, processing method, Rhizoma Curcumae


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A specific and sensitive high-performance liquid chromatographic method was developed for the assay of praziquantel in raw materials and tablets. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay in the wavelenght selected. The method validation yielded good results and included the range, linearity, precision, accuracy, specificity and recovery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Enantiomeric aglycone lignans contained in a mixture were separated from a fraction of the extract of the stems of Alibertia sessilis (Vell.) K. Schum. (Rubiaceae) by preparative high-performance liquid chromatography. An efficient and fast separation can be achieved with methanol-water (30:70, v/v). Their structures were identified as (+)-lyoniresinol 3α-O-β-glucopyranoside and (-)-lyoniresinol 3α-O-β-glucopyranoside, being reported for the first time in Rubiaceae.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes an analytical method using high-performance liquid chromatographic (HPLC) separationcoupled with electrochemical detection to detect three dyes, Solvent Blue 14 (SB-14), Solvent Blue 35 (SB-35) andSolvent Red 24 (SR-24). The dyes were eluted and separated using a reversed-phase column (C-8) under isocraticelution with the mobile phase containing a mixture of acetonitrile/ammonium acetate (5.0 mmol L1) at the ratio of75: 25 (v/v). Two sample pretreatment methods were tested and successfully applied to quantify SB14, SB-35 and SR-24 dyes in gasoline samples. The proposed method was simple, fast and suitable to detect and quantify marker dyes ingasoline sample at low concentration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A glassy carbon electrode chemically modified with nickel nanoparticles coupled with reversed-phase chromatography with pulsed amperometric detection was used for the quantitative analysis of furanic aldehydes in a real sample of sugarcane bagasse hydrolysate. Chromatographic separation was carried out in isocratic conditions (acetonitrile/water, 1:9) with a flow rate of 1.0 mL/min, a detection potential of -50 mV vs. Pd, and the process was completed within 4 min. The analytical curves presented limits of detection of 4.0 × 10(-7) mol/L and 4.3 × 10(-7) mol/L, limits of quantification of 1.3 × 10(-6) and 1.4 × 10(-6) mol/L, amperometric sensitivities of 2.2 × 10(6) nA mol/L and 2.7 × 10(6) nA mol/L for furfural and 5-hydroxymethylfurfural, respectively. The values obtained in this sample by the standard addition method were 1.54 ± 0.02 g/kg for 5-hydroxymethylfurfural and 11.5 ± 0.2 g/kg for furfural. The results demonstrate that this new proposed method can be used for the quick detection of furanic aldehydes without the interference of other electroactive species, besides having other remarkable merits that include excellent peak resolution, analytical repeatability, sensitivity, and accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A stability-indication high performance liquid chromatographic method has been developed for the determination of norfloxacin in tablet dosage forms. Optimum separation was achieved in less than 7 minutes using Eclipse Plus Zorbax C18 Agilent, 150 mm×4.6 mm i.d., 5 μm particle size column. The analyte was resolved by using a mobile phase 5% acetic acid aqueous solution and methanol (80:20, v/v) at a flow rate 1.0 ml/min on an isocratic high performance liquid chromatographic system at a wavelength of 277 nm. Linearity, system suitability, precision, sensitivity, selectivity, specific, and robustness were established by International Conference Harmonization guidelines. For stress studies the drug was subjected to photolysis, oxidation, acid, alkaline and neutral conditions. The analytical conditions and the solvent developed provided good resolution within a short analysis time and economic advantages. The proposed method not required sophisticated and expensive instrumentation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lipid peroxidation (LPO) has been associated with periodontal disease, and the evaluation of malondialdehyde (MDA) in the gingival crevicular fluid (GCF), an inflammatory exudate from the surrounding tissue of the periodontium, may be useful to clarify the role of LPO in the pathogenesis of periodontal disease. We describe the validation of a method to measure MDA in the GCF using high-performance liquid chromatography. MDA calibration curves were prepared with phosphate-buffered solution spiked with increasing known concentrations of MDA. Healthy and diseased GCF samples were collected from the same patient to avoid interindividual variability. MDA response was linear in the range measured, and excellent agreement was observed between added and detected concentrations of MDA. Samples' intra- and interday coefficients of variation were below 6.3% and 12.4%, respectively. The limit of quantitation (signal/noise = 5) was 0.03 mu M. When the validated method was applied to the GCF, excellent agreement was observed in the MDA quantitation from healthy and diseased sites, and diseased sites presented more MDA than healthy sites (P < 0.05). In this study, a validated method for MDA quantitation in GCF was established with satisfactory sensitivity, precision, and accuracy. (C) 2012 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

DEVELOPMENT AND VALIDATION OF AN ANALYTICAL METHOD FOR QUANTITATION OF THE DRUG BEVACIZUMAB BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY. In this study, an analytical method was developed and validated for quantitation of the drug bevacizumab (Avastin (R)) by high performance liquid chromatography (HPLC). The HPLC column was a BioSuite 250 (R) HR SEC, 300 x 7.8 mm x 5 mu m (Waters, USA). The mobile phase consisted of phosphate buffered saline (PBS). The results revealed that the method was specific, precise. accurate, robust and linear (r(2) = 0.998) from 5 to 75 mu g mL(-1). Therefore, this method can be used in drug release studies or in quality control ampoules of the drug.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, rapid and selective method using high-performance liquid chromatography with ultraviolet detection (267 nm) was applied for the determination of tryptophan in plasma. Separation was carried out on a C18 column (150 x 4.6 mm internal diameter) in 6 min. The mobile phase consisted of 5 mM the sodium acetate and acetonitrile (92:8, v/v). The method was shown to be precise and accurate, and good recovery of analyte was achieved, characterizing the method as efficient and reliable for use in laboratory analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Styrax camporum Pohl, known in Brazil as estoraque do campo or cuia de brejo, has been used in the treatment of gastrointestinal diseases. The therapeutic action of S. camporum has been attributed to the ethyl acetate fraction, although the chemical composition of this fraction has not yet been analyzed. In this study, a high-performance liquid chromatography photodiode array detection (HPLC-PAD) method for analysis of Brazilian Styrax species has been developed. The compounds egonol (1) and homoegonol (2) were found to be present in all the samples investigated by HPLC. These compounds were isolated by open column chromatography followed by preparative TLC, and were identified by 1H NMR. Compounds 1 and 2 were thus proposed as phytochemical markers for Styrax, owing to their biological properties and presence in other Styrax species. The developed method has been validated and successfully applied for quantification of 1 and 2 in S. camporum dried leaves and crude ethanolic extracts from S. ferrugineus and S. pohlii aerial parts. Copyright (c) 2011 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents simple, rapid, precise and accurate stability-indicating HPLC and CE methods, which were developed and validated for the determination of nitrendipine, nimodipine and nisoldipine. These drugs are calcium channel antagonists of the 1,4-dihydropyridine type which are used in the treatment of cardiovascular diseases. Experimental results showed a good linear correlation between the area and the concentration of drugs covering a relatively large domain of concentration in all cases. The linearity of the analytical procedures was in the range of 2.0-120.0 mu g mL-1 for nitrendipine, 1.0-100.0 mu g mL(-1) for nimodipine and 100.0-600.0 mu g mL(-1) for nisoldipine, the regression determination coefficient being higher than 0.99 in all cases. The proposed methods were found to have good precision and accuracy. The chemical stability of these drugs was determined under various conditions and the methods have shown adequate separation for their enantiomers and degradation products. In addition, degradation products produced as a result of stress studies did not interfere with the detection of the drugs' enantiomers and the assays can thus be considered stability-indicating.