999 resultados para controle por realimentação dinâmica de saída
Resumo:
The industrial automation is directly linked to the development of information tecnology. Better hardware solutions, as well as improvements in software development methodologies make possible the rapid growth of the productive process control. In this thesis, we propose an architecture that will allow the joining of two technologies in hardware (industrial network) and software field (multiagent systems). The objective of this proposal is to join those technologies in a multiagent architecture to allow control strategies implementations in to field devices. With this, we intend develop an agents architecture to detect and solve problems which may occur in the industrial network environment. Our work ally machine learning with industrial context, become proposed multiagent architecture adaptable to unfamiliar or unexpected production environment. We used neural networks and presented an allocation strategies of these networks in industrial network field devices. With this we intend to improve decision support at plant level and allow operations human intervention independent
Resumo:
In this Thesis, the development of the dynamic model of multirotor unmanned aerial vehicle with vertical takeoff and landing characteristics, considering input nonlinearities and a full state robust backstepping controller are presented. The dynamic model is expressed using the Newton-Euler laws, aiming to obtain a better mathematical representation of the mechanical system for system analysis and control design, not only when it is hovering, but also when it is taking-off, or landing, or flying to perform a task. The input nonlinearities are the deadzone and saturation, where the gravitational effect and the inherent physical constrains of the rotors are related and addressed. The experimental multirotor aerial vehicle is equipped with an inertial measurement unit and a sonar sensor, which appropriately provides measurements of attitude and altitude. A real-time attitude estimation scheme based on the extended Kalman filter using quaternions was developed. Then, for robustness analysis, sensors were modeled as the ideal value with addition of an unknown bias and unknown white noise. The bounded robust attitude/altitude controller were derived based on globally uniformly practically asymptotically stable for real systems, that remains globally uniformly asymptotically stable if and only if their solutions are globally uniformly bounded, dealing with convergence and stability into a ball of the state space with non-null radius, under some assumptions. The Lyapunov analysis technique was used to prove the stability of the closed-loop system, compute bounds on control gains and guaranteeing desired bounds on attitude dynamics tracking errors in the presence of measurement disturbances. The controller laws were tested in numerical simulations and in an experimental hexarotor, developed at the UFRN Robotics Laboratory
Resumo:
This work deals with the development of an experimental study on a power supply of high frequency that provides the toch plasmica to be implemented in PLASPETRO project, which consists of two static converters developed by using Insulated Gate Bipolar Transistor (IGBT). The drivers used to control these keys are triggered by Digital Signal Processor (DSP) through optical fibers to reduce problems with electromagnetic interference (EMI). The first stage consists of a pre-regulator in the form of an AC to DC converter with three-phase boost power factor correction which is the main theme of this work, while the second is the source of high frequency itself. A series-resonant inverter consists of four (4) cell inverters operating in a frequency around 115 kHz each one in soft switching mode, alternating itself to supply the load (plasma torch) an alternating current with a frequency of 450 kHz. The first stage has the function of providing the series-resonant inverter a DC voltage, with the value controlled from the power supply provided by the electrical system of the utility, and correct the power factor of the system as a whole. This level of DC bus voltage at the output of the first stage will be used to control the power transferred by the inverter to the load, and it may vary from 550 VDC to a maximum of 800 VDC. To control the voltage level of DC bus driver used a proportional integral (PI) controller and to achieve the unity power factor it was used two other proportional integral currents controllers. Computational simulations were performed to assist in sizing and forecasting performance. All the control and communications needed to stage supervisory were implemented on a DSP
Resumo:
This work deals with an on-line control strategy based on Robust Model Predictive Control (RMPC) technique applied in a real coupled tanks system. This process consists of two coupled tanks and a pump to feed the liquid to the system. The control objective (regulator problem) is to keep the tanks levels in the considered operation point even in the presence of disturbance. The RMPC is a technique that allows explicit incorporation of the plant uncertainty in the problem formulation. The goal is to design, at each time step, a state-feedback control law that minimizes a 'worst-case' infinite horizon objective function, subject to constraint in the control. The existence of a feedback control law satisfying the input constraints is reduced to a convex optimization over linear matrix inequalities (LMIs) problem. It is shown in this work that for the plant uncertainty described by the polytope, the feasible receding horizon state feedback control design is robustly stabilizing. The software implementation of the RMPC is made using Scilab, and its communication with Coupled Tanks Systems is done through the OLE for Process Control (OPC) industrial protocol
Resumo:
This work proposes the design, the performance evaluation and a methodology for tuning the initial MFs parameters of output of a function based Takagi-Sugeno-Kang Fuzzy-PI controller to neutralize the pH in a stirred-tank reactor. The controller is designed to perform pH neutralization of industrial plants, mainly in units found in oil refineries where it is strongly required to mitigate uncertainties and nonlinearities. In addition, it adjusts the changes in pH regulating process, avoiding or reducing the need for retuning to maintain the desired performance. Based on the Hammerstein model, the system emulates a real plant that fits the changes in pH neutralization process of avoiding or reducing the need to retune. The controller performance is evaluated by overshoots, stabilization times, indices Integral of the Absolute Error (IAE) and Integral of the Absolute Value of the Error-weighted Time (ITAE), and using a metric developed by that takes into account both the error information and the control signal. The Fuzzy-PI controller is compared with PI and gain schedule PI controllers previously used in the testing plant, whose results can be found in the literature.
Resumo:
The main purpose of this work is to develop an environment that allows HYSYS R chemical process simulator communication with sensors and actuators from a Foundation Fieldbus industrial network. The environment is considered a hybrid resource since it has a real portion (industrial network) and a simulated one (process) with all measurement and control signals also real. It is possible to reproduce different industrial process dynamics without being required any physical network modification, enabling simulation of some situations that exist in a real industrial environment. This feature testifies the environment flexibility. In this work, a distillation column is simulated through HYSYS R with all its variables measured and controlled by Foundation Fieldbus devices
Resumo:
There are two main approaches for using in adaptive controllers. One is the so-called model reference adaptive control (MRAC), and the other is the so-called adaptive pole placement control (APPC). In MRAC, a reference model is chosen to generate the desired trajectory that the plant output has to follow, and it can require cancellation of the plant zeros. Due to its flexibility in choosing the controller design methodology (state feedback, compensator design, linear quadratic, etc.) and the adaptive law (least squares, gradient, etc.), the APPC is the most general type of adaptive control. Traditionally, it has been developed in an indirect approach and, as an advantage, it may be applied to non-minimum phase plants, because do not involve plant zero-pole cancellations. The integration to variable structure systems allows to aggregate fast transient and robustness to parametric uncertainties and disturbances, as well. In this work, a variable structure adaptive pole placement control (VS-APPC) is proposed. Therefore, new switching laws are proposed, instead of using the traditional integral adaptive laws. Additionally, simulation results for an unstable first order system and simulation and practical results for a three-phase induction motor are shown
Resumo:
The control, automation and optimization areas help to improve the processes used by industry. They contribute to a fast production line, improving the products quality and reducing the manufacturing costs. Didatic plants are good tools for research in these areas, providing a direct contact with some industrial equipaments. Given these capabilities, the main goal of this work is to model and control a didactic plant, which is a level and flow process control system with an industrial instrumentation. With a model it is possible to build a simulator for the plant that allows studies about its behaviour, without any of the real processes operational costs, like experiments with controllers. They can be tested several times before its application in a real process. Among the several types of controllers, it was used adaptive controllers, mainly the Direct Self-Tuning Regulators (DSTR) with Integral Action and the Gain Scheduling (GS). The DSTR was based on Pole-Placement design and use the Recursive Least Square to calculate the controller parameters. The characteristics of an adaptive system was very worth to guarantee a good performance when the controller was applied to the plant
Resumo:
The stability of synchronous generators connected to power grid has been the object of study and research for years. The interest in this matter is justified by the fact that much of the electricity produced worldwide is obtained with the use of synchronous generators. In this respect, studies have been proposed using conventional and unconventional control techniques such as fuzzy logic, neural networks, and adaptive controllers to increase the stabilitymargin of the systemduring sudden failures and transient disturbances. Thismaster thesis presents a robust unconventional control strategy for maintaining the stability of power systems and regulation of output voltage of synchronous generators connected to the grid. The proposed control strategy comprises the integration of a sliding surface with a linear controller. This control structure is designed to prevent the power system losing synchronism after a sudden failure and regulation of the terminal voltage of the generator after the fault. The feasibility of the proposed control strategy was experimentally tested in a salient pole synchronous generator of 5 kVA in a laboratory structure
Resumo:
Apesar da importância na dinâmica dos ecossistemas aquáticos, as macrófitas podem formar densas e extensas colonizações em corpos hídricos cujos equilíbrios ecológicos foram rompidos. Nessas condições, essas plantas promovem uma série de problemas que as tornam alvos de controle. Para elaboração de planos adequados de manejo dessa vegetação, é fundamental o conhecimento das dinâmicas relativas das populações que a compõem. O objetivo deste trabalho foi realizar levantamentos mensais da composição específica da comunidade de macrófitas que coloniza o reservatório de Santana, localizado no município de Piraí/RJ, monitorando 97 pontos georreferenciados, abrangendo toda a lâmina d'água. Foram identificadas 41 espécies, inseridas em 21 famílias botânicas. As famílias Poaceae, Pontederiaceae e Cyperacae foram as que apresentaram os maiores números de espécies ao longo do ano. Salvinia herzogii e Egeria densa apresentaram as maiores notas anuais de colonização do reservatório. As populações de Eichhornia azurea, Brachiaria arrecta e Paspalum repens completaram o grupo das espécies numericamente mais relevantes. As plantas de hábito flutuante tenderam a apresentar populações com padrão de distribuição geográfica casualizado, enquanto as espécies fixadas no sedimento e as submersas apresentaram populações com padrão agregado. Não houve expressivas variações mensais dos valores dos índices de diversidade (H') e de equitabilidade (E') das comunidades de macrófitas aquáticas ao longo do ano. O dendrograma construído com o coeficiente de Odum mostrou uma seqüência lógica dos meses, evidenciando uma definida sucessão de populações divididas em dois grupos de similaridade separados pelo mês de junho. Nessa época, o nível de água do reservatório foi reduzido e o sedimento ficou exposto, favorecendo as espécies de hábito emergente.
Resumo:
The continuous gas lift method is the main artificial lifting method used in the oil industry for submarine wells, due to its robustness and the large range of flow rate that the well might operate. Nowadays, there is a huge amount of wells producing under this mechanism. This method of elevation has a slow dynamics due to the transients and a correlation between the injected gas rate and the of produced oil rate. Electronics controllers have been used to adjust many parameters of the oil wells and also to improve the efficiency of the gas lift injection system. This paper presents a intelligent control system applied to continuous gas injection in wells, based in production s rules, that has the target of keeping the wells producing during the maximum period of time, in its best operational condition, and doing automatically all necessary adjustments when occurs some disturbance in the system. The author also describes the application of the intelligent control system as a tool to control the flow pressure in the botton of the well (Pwf). In this case, the control system actuates in the surface control valve
Resumo:
A palha pode alterar a dinâmica do herbicida oxyfluorfen no sistema de cana-crua; assim, este trabalho teve por objetivo avaliar a eficácia do oxyfluorfen em condições de casa de vegetação, com a cobertura de palha, no controle das plantas daninhas que ocorrem em cana-crua. Foram avaliadas as espécies de Brachiaria decumbens, Ipomoea grandifolia, Ipomoea quamoclit e Merremia cissoides. A dose utilizada do oxyfluorfen foi de 3 L ha-1 (720 g i.a. ha-1). Os tratamentos constaram de diferentes posicionamentos do herbicida e condições antes e após a aplicação. A porcentagem de controle das plantas daninhas foi avaliada aos 12, 20, 26, 33 e 38 DAA. Os maiores índices de controle aos 38 DAA, independentemente da planta daninha estudada, foram alcançados quando se aplicou oxyfluorfen em tratamentos com a presença de palha em cobertura, com ou sem umidade. No entanto, os resultados obtidos nos demais tratamentos mostraram-se eficientes no controle das diferentes espécies de plantas daninhas estudadas.
Resumo:
O psilídeo-de-concha, Glycaspis brimblecombei, é uma praga exótica específica de Eucalyptus, que causa desfolha, secamento de ponteiros e ramos, podendo levar as árvores à morte. O parasitóide Psyllaephagus bliteus é indicado como principal agente no controle biológico desta praga. Portanto, o monitoramento adequado de as ambas espécies por um método eficiente de amostragem facilitaria o manejo para uma futura tomada de decisão. Devido à falta de informações referentes ao seu comportamento em plantações extensivas de eucalipto no Brasil, este trabalho teve como objetivo estudar as populações de G. brimblecombei e de P. bliteus em florestas de Eucalyptus camaldulensis, utilizando armadilhas amarelas para determinação de sua flutuação populacional e correlacionado-as com variáveis meteorológicas (temperatura e precipitação). A determinação da flutuação populacional (53 pontos amostrais) foi realizada em talhão de 19ha com E. camaldulensis em Luíz Antônio, SP, em 10avaliações quinzenais, entre janeiro e junho de 2005. As populações de ambas as espécies apresentaram correlação inversamente proporcional em função da temperatura e não há correlação com a precipitação no período avaliado.
Resumo:
The treatment of wastewaters contaminated with oil is of great practical interest and it is fundamental in environmental issues. A relevant process, which has been studied on continuous treatment of contaminated water with oil, is the equipment denominated MDIF® (a mixer-settler based on phase inversion). An important variable during the operation of MDIF® is the water-solvent interface level in the separation section. The control of this level is essential both to avoid the dragging of the solvent during the water removal and improve the extraction efficiency of the oil by the solvent. The measurement of oil-water interface level (in line) is still a hard task. There are few sensors able to measure oil-water interface level in a reliable way. In the case of lab scale systems, there are no interface sensors with compatible dimensions. The objective of this work was to implement a level control system to the organic solvent/water interface level on the equipment MDIF®. The detection of the interface level is based on the acquisition and treatment of images obtained dynamically through a standard camera (webcam). The control strategy was developed to operate in feedback mode, where the level measure obtained by image detection is compared to the desired level and an action is taken on a control valve according to an implemented PID law. A control and data acquisition program was developed in Fortran to accomplish the following tasks: image acquisition; water-solvent interface identification; to perform decisions and send control signals; and to record data in files. Some experimental runs in open-loop were carried out using the MDIF® and random pulse disturbances were applied on the input variable (water outlet flow). The responses of interface level permitted the process identification by transfer models. From these models, the parameters for a PID controller were tuned by direct synthesis and tests in closed-loop were performed. Preliminary results for the feedback loop demonstrated that the sensor and the control strategy developed in this work were suitable for the control of organic solvent-water interface level
Resumo:
The study that resulted in this dissertation was developed at OU RNCE PETROBRAS, in Natal, which implemented a project of rational use and reuse of water, including use of wastewater from a Sewage Treatment Plant (STP) already in place, diluted with water from own wells for irrigation of green area of the building complex corporate enterprise. Establish a methodology that can serve as guidelines for future projects controlled reuse of water like this was the objective of this research. Been proposed, implemented and evaluated three instruments of sanitary and environmental control: 1) adaptation of sewage treatment plant and quality control of the treated effluent 2) analysis of soil-nutrient interaction in the irrigated area, 3) knowledge of the local hydrogeology, especially with regard to the direction of flow of the aquifer and location of collection wells of Companhia de Águas e Esgotos do Rio Grande do Norte (CAERN) situated in the surroundings. These instruments have proven sufficient and appropriate to ensure the levels of sanitary and environmental control proposed and studied, which were: a) control of water quality off the STP and the output of the irrigation reservoir, b) control of water quality sub surface soil and assessment of progress on soil composition, c) assessment of water quality in the aquifer. For this, we must: 1) establishing the monitoring plan of the STP and its effluent quality sampling points and defining the parameters of analysis, improve the functioning of that identifying the adequacy of flow and screening as the main factors of operational control, and increase the efficiency of the station to a relatively low cost, using additional filters, 2) propose, implement and adapt simple collectors to assess the quality of water percolating into the soil of the irrigated area, 3) determine the direction of groundwater flow in the area study and select the wells for monitoring of the aquifer.