984 resultados para ULTRASOUND-ASSISTED SYNTHESIS


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background:There is no actual evidence that the ART are directly related to the occurrence of weight discordance. In some studies, ART-­‐conceived twin pregnancies are at greater risk than non-­‐ART-­‐conceived ones for pregnancy complications and adverse perinatal outcome: the incidences of pregnancy-­‐induced hypertension, uterine bleeding, premature contractions, IUGR, fetal death, discordance, and cesarean section were significantly higher. Discordance rate was elevated (25.3% vs.17.0%) among ART twins, which can increase perinatal risk (increased incidence of SGA and NICU admission). Other studies say that perinatal and neonatal morbidity, gestational age at delivery, and birth weight are not affected by ART. Regarding the first trimester ultrasound, some studies didn’t notice significant differences in CRL disparity or birth weight discordance between spontaneous and ART-­‐ conceived dichorionic twin pregnancies. In ART-­‐conceived dichorionic twin pregnancies, CRL disparity may be associated with birth weight discordance. In some studies, CRL discordance in twin pregnancies in the first trimester was a frequent finding. Objectives: To analyze the association of the ART in the occurrence of weight discordance in the pregnancies between 2010 and 2013 in the Hospital Universitari de Girona Doctor Josep Trueta, and to describe the proportion of diagnosis of growth discordance in the first trimester by the ultrasonography technology. Methods: A retrospective cohort study will be performed in those patients with twin pregnancies between 2010 and 2013, within the Hospital Universitari de Girona Doctor Josep Trueta (HUJT). A retrospective and descriptive study will be done in those cases with discordance weight in the moment of the birth, in which the CRL will be studied in the first trimester ultrasound, describing the percentage of discordance detected in that moment. The general characteristics of the sample are going to be analyzed by Logistic RegressionInfluenceof

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background:There is no actual evidence that the ART are directly related to the occurrence of weight discordance. In some studies, ART-­‐conceived twin pregnancies are at greater risk than non-­‐ART-­‐conceived ones for pregnancy complications and adverse perinatal outcome: the incidences of pregnancy-­‐induced hypertension, uterine bleeding, premature contractions, IUGR, fetal death, discordance, and cesarean section were significantly higher. Discordance rate was elevated (25.3% vs.17.0%) among ART twins, which can increase perinatal risk (increased incidence of SGA and NICU admission). Other studies say that perinatal and neonatal morbidity, gestational age at delivery, and birth weight are not affected by ART. Regarding the first trimester ultrasound, some studies didn’t notice significant differences in CRL disparity or birth weight discordance between spontaneous and ART-­‐ conceived dichorionic twin pregnancies. In ART-­‐conceived dichorionic twin pregnancies, CRL disparity may be associated with birth weight discordance. In some studies, CRL discordance in twin pregnancies in the first trimester was a frequent finding. Objectives: To analyze the association of the ART in the occurrence of weight discordance in the pregnancies between 2010 and 2013 in the Hospital Universitari de Girona Doctor Josep Trueta, and to describe the proportion of diagnosis of growth discordance in the first trimester by the ultrasonography technology. Methods: A retrospective cohort study will be performed in those patients with twin pregnancies between 2010 and 2013, within the Hospital Universitari de Girona Doctor Josep Trueta (HUJT). A retrospective and descriptive study will be done in those cases with discordance weight in the moment of the birth, in which the CRL will be studied in the first trimester ultrasound, describing the percentage of discordance detected in that moment. The general characteristics of the sample are going to be analyzed by Logistic RegressionInfluenceof

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For the detection and management of osteoporosis and osteoporosis-related fractures, quantitative ultrasound (QUS) is emerging as a relatively low-cost and readily accessible alternative to dual-energy X-ray absorptiometry (DXA) measurement of bone mineral density (BMD) in certain circumstances. The following is a brief, but thorough review of the existing literature with respect to the use of QUS in 6 settings: 1) assessing fragility fracture risk; 2) diagnosing osteoporosis; 3) initiating osteoporosis treatment; 4) monitoring osteoporosis treatment; 5) osteoporosis case finding; and 6) quality assurance and control. Many QUS devices exist that are quite different with respect to the parameters they measure and the strength of empirical evidence supporting their use. In general, heel QUS appears to be most tested and most effective. Overall, some, but not all, heel QUS devices are effective assessing fracture risk in some, but not all, populations, the evidence being strongest for Caucasian females over 55 years old. Otherwise, the evidence is fair with respect to certain devices allowing for the accurate diagnosis of likelihood of osteoporosis, and generally fair to poor in terms of QUS use when initiating or monitoring osteoporosis treatment. A reasonable protocol is proposed herein for case-finding purposes, which relies on a combined assessment of clinical risk factors (CR.F) and heel QUS. Finally, several recommendations are made for quality assurance and control.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background:There is no actual evidence that the ART are directly related to the occurrence of weight discordance. In some studies, ART-­‐conceived twin pregnancies are at greater risk than non-­‐ART-­‐conceived ones for pregnancy complications and adverse perinatal outcome: the incidences of pregnancy-­‐induced hypertension, uterine bleeding, premature contractions, IUGR, fetal death, discordance, and cesarean section were significantly higher. Discordance rate was elevated (25.3% vs.17.0%) among ART twins, which can increase perinatal risk (increased incidence of SGA and NICU admission). Other studies say that perinatal and neonatal morbidity, gestational age at delivery, and birth weight are not affected by ART. Regarding the first trimester ultrasound, some studies didn’t notice significant differences in CRL disparity or birth weight discordance between spontaneous and ART-­‐ conceived dichorionic twin pregnancies. In ART-­‐conceived dichorionic twin pregnancies, CRL disparity may be associated with birth weight discordance. In some studies, CRL discordance in twin pregnancies in the first trimester was a frequent finding. Objectives: To analyze the association of the ART in the occurrence of weight discordance in the pregnancies between 2010 and 2013 in the Hospital Universitari de Girona Doctor Josep Trueta, and to describe the proportion of diagnosis of growth discordance in the first trimester by the ultrasonography technology. Methods: A retrospective cohort study will be performed in those patients with twin pregnancies between 2010 and 2013, within the Hospital Universitari de Girona Doctor Josep Trueta (HUJT). A retrospective and descriptive study will be done in those cases with discordance weight in the moment of the birth, in which the CRL will be studied in the first trimester ultrasound, describing the percentage of discordance detected in that moment. The general characteristics of the sample are going to be analyzed by Logistic RegressionInfluenceof

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONTEXT: The current standard for diagnosing prostate cancer in men at risk relies on a transrectal ultrasound-guided biopsy test that is blind to the location of the cancer. To increase the accuracy of this diagnostic pathway, a software-based magnetic resonance imaging-ultrasound (MRI-US) fusion targeted biopsy approach has been proposed. OBJECTIVE: Our main objective was to compare the detection rate of clinically significant prostate cancer with software-based MRI-US fusion targeted biopsy against standard biopsy. The two strategies were also compared in terms of detection of all cancers, sampling utility and efficiency, and rate of serious adverse events. The outcomes of different targeted approaches were also compared. EVIDENCE ACQUISITION: We performed a systematic review of PubMed/Medline, Embase (via Ovid), and Cochrane Review databases in December 2013 following the Preferred Reported Items for Systematic reviews and Meta-analysis statement. The risk of bias was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. EVIDENCE SYNTHESIS: Fourteen papers reporting the outcomes of 15 studies (n=2293; range: 13-582) were included. We found that MRI-US fusion targeted biopsies detect more clinically significant cancers (median: 33.3% vs 23.6%; range: 13.2-50% vs 4.8-52%) using fewer cores (median: 9.2 vs 37.1) compared with standard biopsy techniques, respectively. Some studies showed a lower detection rate of all cancer (median: 50.5% vs 43.4%; range: 23.7-82.1% vs 14.3-59%). MRI-US fusion targeted biopsy was able to detect some clinically significant cancers that would have been missed by using only standard biopsy (median: 9.1%; range: 5-16.2%). It was not possible to determine which of the two biopsy approaches led most to serious adverse events because standard and targeted biopsies were performed in the same session. Software-based MRI-US fusion targeted biopsy detected more clinically significant disease than visual targeted biopsy in the only study reporting on this outcome (20.3% vs 15.1%). CONCLUSIONS: Software-based MRI-US fusion targeted biopsy seems to detect more clinically significant cancers deploying fewer cores than standard biopsy. Because there was significant study heterogeneity in patient inclusion, definition of significant cancer, and the protocol used to conduct the standard biopsy, these findings need to be confirmed by further large multicentre validating studies. PATIENT SUMMARY: We compared the ability of standard biopsy to diagnose prostate cancer against a novel approach using software to overlay the images from magnetic resonance imaging and ultrasound to guide biopsies towards the suspicious areas of the prostate. We found consistent findings showing the superiority of this novel targeted approach, although further high-quality evidence is needed to change current practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Assisted reproductive technologies (ART) induce vascular dysfunction in humans and mice. In mice, ART-induced vascular dysfunction is related to epigenetic alteration of the endothelial nitric oxide synthase (eNOS) gene, resulting in decreased vascular eNOS expression and nitrite/nitrate synthesis. Melatonin is involved in epigenetic regulation, and its administration to sterile women improves the success rate of ART. We hypothesized that addition of melatonin to culture media may prevent ART-induced epigenetic and cardiovascular alterations in mice. We, therefore, assessed mesenteric-artery responses to acetylcholine and arterial blood pressure, together with DNA methylation of the eNOS gene promoter in vascular tissue and nitric oxide plasma concentration in 12-wk-old ART mice generated with and without addition of melatonin to culture media and in control mice. As expected, acetylcholine-induced mesenteric-artery dilation was impaired (P = 0.008 vs. control) and mean arterial blood pressure increased (109.5 ± 3.8 vs. 104.0 ± 4.7 mmHg, P = 0.002, ART vs. control) in ART compared with control mice. These alterations were associated with altered DNA methylation of the eNOS gene promoter (P < 0.001 vs. control) and decreased plasma nitric oxide concentration (10.1 ± 11.1 vs. 29.5 ± 8.0 μM) (P < 0.001 ART vs. control). Addition of melatonin (10(-6) M) to culture media prevented eNOS dysmethylation (P = 0.005, vs. ART + vehicle), normalized nitric oxide plasma concentration (23.1 ± 14.6 μM, P = 0.002 vs. ART + vehicle) and mesentery-artery responsiveness to acetylcholine (P < 0.008 vs. ART + vehicle), and prevented arterial hypertension (104.6 ± 3.4 mmHg, P < 0.003 vs. ART + vehicle). These findings provide proof of principle that modification of culture media prevents ART-induced vascular dysfunction. We speculate that this approach will also allow preventing ART-induced premature atherosclerosis in humans.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim of the Thesis is to study and understand the theoretical concept of Metanational corporation and understand how the Web 2.0 technologies can be used to support the theory. Empiric part of the study compares the theory to the case company’s current situation Goal of theoretical framework is to show how the Web 2.0 technologies can be used in the three levels of the Metanational corporation. In order to do this, knowledge management and more accurately knowledge transferring is studied to understand what is needed from the Web 2.0 technologies in the different functions and operations of the Metanational corporation. Final synthesis of the theoretical framework is to present a model where the Web 2.0 technologies are placed on the levels of the Metanational corporation. Empirical part of the study is based on interviews made in the case company. Aim of the interviews is to understand the current state of the company related to the theoretical framework. Based on the interviews, the differences between the theoretical concept and the case company are presented and studied. Finally the study presents the found problem areas, and where the adoption of the Web 2.0 tools is seen as beneficiary, based on the interviews and theoretical framework.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two new families of building blocks have been prepared and fully characterized and their coordination chemistry exploited for the preparation of molecule-based magnetic materials. The first class of compounds were prepared by exploiting the chemistry of 3,3'-diamino-2,2'-bipyridine together with 2-pyridine carbonyl chloride or 2-pyridine aldehyde. Two new ligands, 2,2'-bipyridine-3,3'-[2-pyridinecarboxamide] (Li, 2.3) and N'-6/s(2-pyridylmethyl) [2,2'bipyridine]-3,3'-diimine (L2, 2.7), were prepared and characterized. For ligand L4, two copper(II) coordination compounds were isolated with stoichiometrics [Cu2(Li)(hfac)2] (2.4) and [Cu(Li)Cl2] (2.5). The molecular structures of both complexes were determined by X-ray crystallography. In both complexes the ligand is in the dianionic form and coordinates the divalent Cu(II) ions via one amido and two pyridine nitrogen donor atoms. In (2.4), the coordination geometry around both Cu11 ions is best described as distorted trigonal bipyramidal where the remaining two coordination sites are satisfied by hfac counterions. In (2.5), both Cu(II) ions adopt a (4+1) distorted square pyramidal geometry. One copper forms a longer apical bond to an adjacent carbonyl oxygen atom, whereas the second copper is chelated to a neighboring Cu-Cl chloride ion to afford chloride bridged linear [Cu2(Li)Cl2]2 tetramers that run along the c-axis of the unit cell. The magnetic susceptibility data for (2.4) reveal the occurrence of weak antiferromagnetic interactions between the copper(II) ions. In contrast, variable temperature magnetic susceptibility measurements for (2.5) reveal more complex magnetic properties with the presence of ferromagnetic exchange between the central dimeric pair of copper atoms and weak antiferromagnetic exchange between the outer pairs of copper atoms. The Schiff-base bis-imine ligand (L2, 2.7) was found to be highly reactive; single crystals grown from dry methanol afforded compound (2.14) for which two methanol molecules had added across the imine double bond. The susceptibility of this ligand to nucleophilic attack at its imine functionality assisted via chelation to Lewis acidic metal ions adds an interesting dimension to its coordination chemistry. In this respect, a Co(II) quaterpyridine-type complex was prepared via a one-pot transformation of ligand L2 in the presence of a Lewis acidic metal salt. The rearranged complex was characterized by X-ray crystallography and a reaction mechanism for its formation has been proposed. Three additional rearranged complexes (2.13), (2.17) and (2.19) were also isolated when ligand (L2, 2.7) was reacted with transition metal ions. The molecular structures of all three complexes have been determined by X-ray crystallography. The second class of compounds that are reported in this thesis, are the two diacetyl pyridine derivatives, 4-pyridyl-2,6-diacetylpyridine (5.5) and 2,2'-6,6'-tetraacetyl-4,4'-bipyridine (5.15). Both of these compounds have been designed as intermediates for the metal templated assembly of a Schiff-base N3O2 macrocycle. From compound (5.15), a covalently tethered dimeric Mn(II) macrocyclic compound of general formula {[Mn^C^XJCl-FkO^Cl-lO.SFbO (5.16) was prepared and characterized. The X-ray analysis of (5.16) reveals that the two manganese ions assume a pentagonal-bipyramidal geometry with the macrocycle occupying the pentagonal plane and the axial positions being filled by a halide ion and a H2O molecule. Magnetic susceptibility data reveal the occurrence of antiferromagnetic interactions between covalently tethered Mn(II)-Mn(II) dimeric units. Following this methodology a Co(II) analogue (5.17) has also been prepared which is isostructural with (5.16).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Immobilized lipase B from Candida antarctica (Novozym® 435, N435) was utilized as part of a chemoenzymatic strategy for the synthesis of branched polyesters based on a cyclotetrasiloxane core in the absence of solvent. Nuclear magnetic resonance spectroscopy and matrix-assisted laser desorption ionization time-of-flight mass spectrometry were utilized to monitor the reactions between tetraester cyclotetrasiloxanes and aliphatic diols. The enzyme-mediated esterification reactions can achieve 65– 80% consumption of starting materials in 24–48 h. Longer reaction times, 72–96 h, resulted in the formation of cross-linked gel-like networks. Gel permeation chromatography of the polymers indicated that the masses were Mw ¼ 11 400, 13 100, and 19 400 g mol 1 for the substrate pairs of C7D4 ester/ octane-1,8-diol, C10D4 ester/pentane-1,5-diol and C10D4 ester/octane-1,8-diol respectively, after 48 h. Extending the polymerization for an additional 24 h with the C10D4 ester/octane-1,8-diol pair gave Mw ¼ 86 800 g mol 1. To the best of our knowledge this represents the first report using lipase catalysis to produce branched polymers that are built from a cyclotetrasiloxane core.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dans cette thèse, nous démontrons des travaux sur la synthèse à faible coût des matériaux de cathode et l'anode pour les piles lithium-ion. Pour les cathodes, nous avons utilisé des précurseurs à faible coût pour préparer LiFePO4 et LiFe0.3Mn0.7PO4 en utilisant une méthode hydrothermale. Tout d'abord, des matériaux composites (LiFePO4/C) ont été synthétisés à partir d'un précurseur de Fe2O3 par une procédé hydrothermique pour faire LiFePO4(OH) dans une première étape suivie d'une calcination rapide pour le revêtement de carbone. Deuxièmement, LiFePO4 avec une bonne cristallinité et une grande pureté a été synthétisé en une seule étape, avec Fe2O3 par voie hydrothermale. Troisièmement, LiFe0.3Mn0.7PO4 a été préparé en utilisant Fe2O3 et MnO comme des précurseurs de bas coûts au sein d'une méthode hydrothermale synthétique. Pour les matériaux d'anode, nous avons nos efforts concentré sur un matériau d'anode à faible coût α-Fe2O3 avec deux types de synthèse hydrothermales, une a base de micro-ondes (MAH) l’autre plus conventionnelles (CH). La nouveauté de cette thèse est que pour la première fois le LiFePO4 a été préparé par une méthode hydrothermale en utilisant un précurseur Fe3+ (Fe2O3). Le Fe2O3 est un précurseur à faible coût et en combinant ses coûts avec les conditions de synthèse à basse température nous avons réalisé une réduction considérable des coûts de production pour le LiFePO4, menant ainsi à une meilleure commercialisation du LiFePO4 comme matériaux de cathode dans les piles lithium-ion. Par cette méthode de préparation, le LiFePO4/C procure une capacité de décharge et une stabilité de cycle accrue par rapport une synthétisation par la méthode à l'état solide pour les mêmes précurseurs Les résultats sont résumés dans deux articles qui ont été récemment soumis dans des revues scientifiques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Les ligands de carbènes N-hétérocycliques (NHC) qui possèdent une symétrie C1 attirent beaucoup l’attention dans la littérature. Le présent projet de recherche propose de synthétiser une nouvelle série de ligands NHC C1-symétriques avec deux groupements N-alkyles qui exploitent un relais chiral. Un protocole modulaire et efficace pour la synthèse des sels d’imidazolium chiraux qui servent comme préligands pour les NHC a été développé. Quelques-uns de ces nouveaux ligands ont été installés sur le cuivre et de l’or, créant de nouveaux complexes chiraux. Les nouveaux complexes à base de cuivre ont été évalués comme catalyseurs pour le couplage oxydatif de 2-naphthols. Les ligands C1-symmétriques ont fourni des meilleurs rendements que les ligands C2-symmétriques. Au cours de l’optimisation, des additifs ont été évalués; les additifs à base de pyridine ont fourni des énantiosélectivités modérées tandis que les additifs à base de malonate ont donné des meilleurs rendements de la réaction de couplage oxydatif. Ultérieurement, les additifs à base de malonate ont été appliqués envers l’hétérocouplage de 2-naphthols. Le partenaire de couplage qui est riche en électrons est normalement en grand excès à cause de sa tendance à dégrader. Avec le bénéfice de l’additif, les deux partenaires de couplage peuvent être utilisés dans des quantités équivalentes. La découverte de l’effet des additifs a permis le développement d’un protocole général pour l’hétérocouplage de 2-naphthols.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cobalt nanotubes (CoNTs) with very high longitudinal coercivity were prepared by electrodeposition of cobalt acetate for the first time by using anodized alumina (AAO) template. They were then characterized with X-ray diffraction (XRD), a field emission scanning electron microscope (FESEM), and a transmission electron microscope (TEM). Formation of a highly ordered hexagonal cobalt phase is observed. Room temperature SQUID (superconducting quantum interference device) magnetometer measurements indicate that the easy axis of magnetization is parallel to the nanotube axis. These CoNTs exhibit very high longitudinal coercivity of ∼820 Oe. A very high intertubular interaction resulting from magnetostatic dipolar interaction between nanotubes is observed. Thick-walled nanotubes were also fabricated by using cobalt acetate tetrahydrate precursors. A plausible mechanism for the formation of CoNTs based on mobility assisted growth is proposed. The role of the hydration layer and the mobility of metal ions are elucidated in the case of the growth mechanism of one-dimensional geometry

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Magnetic heterostructures with carbon nanotubes having multiple functionalities are fascinating materials which can be manipulated by means of an external magnetic field. In this paper we report our investigations on the synthesis and optical limiting properties of pristine cobalt nanotubes and high coercivity cobalt-in-carbon nanotubes (a new nanosystem where carbon nanotubes are filled with cobalt nanotubes). A general mobility assisted growth mechanism for the formation of one-dimensional nanostructures inside nanopores is verified in the case of carbon nanotubes. The open-aperture z-scan technique is employed for the optical limiting measurements in which nanosecond laser pulses at 532 nm have been used for optical excitation. Compared to the benchmark pristine carbon nanotubes these materials show an enhanced nonlinear optical absorption, and the nonlinear optical parameters calculated from the data show that these materials are efficient optical limiters. To the best of our knowledge this is the first report where the optical limiting properties of metal nanotubes are compared to those of carbon nanotubes

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hybrid magnetic nanostructures with high coercivity have immense application potential in various fields. Nickel (Ni) electrodeposited inside Cobalt (Co) nanotubes (a new system named Ni @ Co nanorods) were fabricated using a two-step potentiostatic electrodeposition method. Ni @ Co nanorods were crystalline, and they have an average diameter of 150 nm and length of *15 lm. The X-ray diffraction studies revealed the existence of two separate phases corresponding to Ni and Co. Ni @ Co nanorods exhibited a very high longitudinal coercivity. The general mobility-assisted growth mechanism proposed for the growth of one-dimensional nanostructures inside nano porous alumina during potentiostatic electrodeposition is found to be valid in this case too

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Multiwall carbon nanotubes (MWCNTs) possessing an average inner diameter of 150 nm were synthesized by template assisted chemical vapor deposition over an alumina template. Aqueous ferrofluid based on superparamagnetic iron oxide nanoparticles (SPIONs) was prepared by a controlled co-precipitation technique, and this ferrofluid was used to fill the MWCNTs by nanocapillarity. The filling of nanotubes with iron oxide nanoparticles was confirmed by electron microscopy. Selected area electron diffraction indicated the presence of iron oxide and graphitic carbon from MWCNTs. The magnetic phase transition during cooling of the MWCNT–SPION composite was investigated by low temperature magnetization studies and zero field cooled (ZFC) and field cooled experiments. The ZFC curve exhibited a blocking at ∼110 K. A peculiar ferromagnetic ordering exhibited by the MWCNT–SPION composite above room temperature is because of the ferromagnetic interaction emanating from the clustering of superparamagnetic particles in the constrained volume of an MWCNT. This kind of MWCNT–SPION composite can be envisaged as a good agent for various biomedical applications